John Corwin
MITSUBISHI W.SLIM,
® ELECTRIC Split-ductless A/C and Heat Pumps
.I will Jill, -
Job Name: Location: Date:
Purchaser: Engineer:
Submitted to: For ❑Reference ❑Approval ❑Construction
Unit Designation: Schedule No.:
GENERAL FEATURES Electrical Requirements
•Compact side discharge Power Supply................. ...208/230V, 1-Phase,60 Hz
outdoor unit ; - r Breaker Size.... ... ..... ...... ............ ..........20 A
w.-
a, MCA.. .... ........... ........ .... .. ..... ...... . . 15 A
•Wireless or wired remote C
controller,depending on the :§
indoor units used Voltage
•Quiet operation—both indoor Indoor-Outdoor S1-S2 .... . .. . .. AC 208/230V
and outdoor units r HIMi � ) Indoor-Outdoor S2-S3 ..... .. .. ..... . DC 12-24V
•Automatic fan speed control t ji3N 1
•Auto restart following a power ; 11 OPERATING RANGE
Indoor IntakeAir Temp. Outdoor Intake Air Temp.
Outage
•Self-check function—integrated Maximum 95•F(35•C)DB,71-F(7C)AS 115•F(46•C)D8
Cooling diagnostics Outdoor Unit MXZ-2A20NA Minimum 67•F(19°C)D8,57•F(14°C)We 14•F(-10•C)DB
•Advanced microprocessor control Maximum 80-F(27•C)OB.67•F(19-c)wB 75•F(24•C)D8,65-F(18•C)WB
•Limited warranty:one year on parts and Heating
Minimum 7l1°F(21•C)D8,60°F(169C)Vti8 14°F(-10°C)DB.12°F(-11-C)Vvt3
defects and six years on compressor
OPTIONAL OUTDOOR UNIT ACCESSORY Compressor . ... . . . ... .. .. . . .. DC Inverter-driven Twin Rotary
•Air Outlet Guide(MAC-889SG) Fan Motor... .... .. .... . .. . . .. . .. . .. .. .... .. . . 0.96 F.L.A.
Cooling* Sound Pressure Level
Rated Capacity(Nan-ducted/Ducted)...20,000 Btu/h/20,000 Btu/h Cooling. .............. .. ...... .. .. ........... . .49 dB(A)
Minimum Capacity(Non-ducted/Ducted) ..7,800 Btu/h/7,800 Btu/h Heating.................... ... ... ........... .. . 51 dB(A)
Total Input(Non-ducted/Ducted).... ..........2,150 W/2,150 W
Heating at 47*F* DIMENSIONS INCHES/MM
Rated Capacity(Non-ducted/Ducted)...22,000 Btu/h/22,000 Btu/h Minimum Capacity(Non-ducted/Ducted) ..8,500 Btu/h/8,500 Btu/h D 13/W 33-1 /840
/16
/16
Total Input(Non-ducted/Ducted)..............1,780 W/1,780 W
330
Heating at 17°F* H 27-1 5/16 1 710
Rated Capacity(Non-ducted/Ducted)..14,500 Btu/h/12,500 Btu/h Weight .... ...... ..... .. .... .. .. . ... ... . . .130 lbs./59 kg
Total Input(Non-ducted/Ducted).......... ...1,500 W/1,430 W Refrigerant Type. ...... .... .... . ........ ..�-�R410A
*Rating Conditions(Cooling)-Indoor:80°F(27*C)DB/67°F(19°C)WB. Refrigerant Pipe Size O.D.—Two Ports
Outdoor:95T(35°C)DB/75°F(24°C)w6. Gas Side.. .......................... . A,B:3/8"/9.52 mm
(Heating)-Indoor:70°F(21*C)DB/601F(16*C)WB.Outdoor:47°F(8°C)DB! Liquid Side ................................1/4"/6.35 mm
43"F(6°C)WB. Max.Refrigerant Pipe Length............... ......164'/50 m
(Heating at 17°F)-Indoor:70°F(21°C)DB/60*F(16°C)WB.Outdoor:17°F Max.Refrigerant Pipe Height Difference
(-8"c)DB/15°F(-9°C)WB. If Indoor Unit is Above Outdoor Unit ......... ...... 49'/15 m
(For data on specific indoor units[all ducted,all non-ducted,and both ducted If Indoor Unit is Below Outdoor Unit.... ... ... ...... 33'/10 m
and non-ducted]combinations,seethe MXZ Technical and Service Manual.) Connection Method . ... ... .. ... ..... ...... ... ......Flared
COMPATIBLE INDOOR UNITS AND ASSOCIATED REMOTE CONTROLLERS MXZ-2A20NA ENERGY EFFICIENCIES
Indoor Unit Type SEER HSPF
Horizontal-ducted Indoor Units:SEZ-KD09,12,15,18NA Non-ducted 16 8.5
Ducted and Nin-ducted 15.5 8.5
Ducted 15.5 8.5
MXZ-2A20 Combinations*(with wall-mounted and/or horizontal-ducted indoor units)
Remote Controller PAR-2IMAA- Cooling -
Packaged with SEZ lindloorunit UWJW ` -/.[
Power usage(w)
Wall-mounted Indoor Units:MSZ-A ,12, 5,17NA
9,000 1 9.000 1 18,000 1.740-1.780
9+9
8,500 11,500
9+12
9+15 7,500 12,500 20,000 2,150-2,190
Wall-mounted Indoor Units:MSZ-FD09,12NA 10,000 10,000
Wireless Renate Controller-
12112 GC;G
Packagedvith MSZ-A and MSZ- Information provided at 208/230V.
FD(Optional Wired PAR-21MAA
Remote Controller) SYSTEM COMPONENTS
Outdoor Unit.... .........MXZ-2A20NA /�M JUL
uE
Indoor Unit............Two Indoor Units I RR
Refer to the separate submittal forms for the SEZ and MSZ Indoor Units. Necessary(Select Style as Installation Requires)
6-9/16' 19-11/16' 6-21132"
2-1/2" 9-3116' 11-11/32' Unit: Inch
n Rear Air
44
v Inuke
` U
a :
sme Aa lMexe
0
m -
3-0(1-5116')Drain Hole
mmaw
n Air
v Discharge
�413132'•13116'Oval Hde
(Foundation Bolt M10)
33-1/16' 1-3116"
7-718' 1-3116' 13' 1/2'
3.0715'P—hM hulaa
C"eun nee hole
IT r
e } Utir a 1
S GAS JI LIO Q�IIPFLARE
1_I0 GAS 08'FLARE
UroIA
GAS
11.314' 29132'
m
1.Instailation space
m
Note:Leave front and both sides A
clearance fully. ; More than 3-15/16'
a
® — Grounding terminal
Conduit
/cover
Note:Leave front and overhead I
clearance fully. Lock nut connector
L �
O I _�-
O
More than 3-15/16" More thanl3-25132"
2.Service space to
to
Note:Leave rear,overhead and
d
both sides clearance fully. t o 16
�ttltt�
iJJ b
o �
0 More than 3-15/16'
SERVICE SPACE
�7 More than 13-25/32' More than 13-25/32'
4 MITSUBISHI
i'
'` ELECTRIC
HVAC Advanced Products Division
nit
/ 3400 Lawrenceville Suwanee Rd
T Suwanee,GA 30024
Tele:678-376-2900•Fax:800-889-9904
Toll Free:800-433-4822(#3)
www.mehvac.com
C SD-MXZ-2A20NA for Multiple Indoor Unit Styles -200903 0 MITSUBISHI ELECTRIC!HVAC 2009 Specifications are subject to change without notice.
MITSUBISHI
ELECTRIC W.SLIM,
HVAC Advanced Products Division Split Zoning A/C and Heat Pumps
Job Name: Location: Date:
Purchaser: Engineer:
Submitted to: For ❑Reference ❑Approval ❑Construction
Unit Designation: Schedule No.:
GENERAL FEATURES
Wall-mounted indoor unit for residential applications
•Compact side discharge outdoor unit
•Zone control /////� w�
•Quiet operation for both indoor and outdoor units rHy� ��
•"Powerful Mode"function permits system to temporarily run at a Indoor Unit:MSY-A24NA � rJ�//J�y
lower/higher temperature with an increased fan speed,which \\�B
quickly brings the room to the optimum comfort level
•Wireless remote controller is included
•Indoor unit powered from outdoor unit using A-Control
•Automatic restart following a power outage k��
•Self-check functon—onboard diagnostics outdoor unit MUY-A24NA
•Dry Mode function is standard
•Limited warranty:one year on parts and defects and six years on the
compressor
Wireless Remote Controller
Indoor Unit
MCA. .. .... ... ....... .. .. .. . . .. . . .. . ... ........ .. 1.0A
Fan Motor.. .............. .... . ..... .......... .0.76 F.L.A.
OPTIONAL ACCESSORIES Airflow(Lo-Med-Hi-Powerful)
Indoor Unit Cooling .. . .. ...... .. ..... . ..296-431 -568-624 Dry CFM
•M-NET Control Adapter(MAC-3991F) 265-385-508-558 Wet CFM
•MA Contact Terminal Interface(MAC-3971F)
•Wired Remote Controller(PAR-21 MAA;requires MAC-3971F) Sound Pressure Level(Lo-Med-Hi-Powerful)
•Condensate Pump(230V;S13100-230) Cooling .. ...... .. . .. . ... ... . ... .. . 34-40-49-51 dB(A)
•Anti-allergy Enzyme Filter(MAC-2300FT)
•Three-pole Disconnect Switch(TAZ-MS303) DIMENSIONS UNIT INCHES/MM
W 43-5/16/1,100
D 10-1/4/260
H 12-13/16/325
Weight.. .. .................... .. .. ..... . 371yL�L/17 kg
External Finish................ . . .. .. MUnsell'NY7.8/1.1
Field Drainpipe Size O.D......................5/8"/15.88 mm
Remote Controller ........................... .... Wireless
Outdoor Unit
Compressor ................ ...DC-driven Inverter Twin Rotary
Cooling' MCA..............................................17 A
Rated Capacity...............................22,000 Btu/h Fan Motor.....................................0.93 F.L.A.
Minimum Capacity .............................4,400 Btu/h Sound Pressure Level
SEER ........ ................................. ... 16.0 Cooling . ... .. ... ..... ........................55 dB(A)
Total Input................ ....... 2,880 W
Rating Conditions(Cooling)-Indoor:80°F(27°C)DB,67°F(19°C)WB;
Outdoor:95°F(35°C)DB,750F(24°C)WB. DIMENSIONS INCHES/MM
�/ 33-1/16!840
Power Supply... . . . ..... .. ... . . ..208/230V,1-Phase,60 Hz D 13 I/16
330
Breaker Size. ... .. . . ... .... . .. . . . .. .. .. .. . ... . ... . . 20 A
H 33-7l16 18,
Voltage
Indoor-Outdoor S1-S2 ..... .... . .... .... ....AC 208/230V
Indoor-Outdoor S2-S3 ... . .. .. .. ... .... . ... .. . .DC 12-24V Weight ....... . .. ......... ... . ... .... . . ... 128 lbs./58 kg
Indoor-Remote Controller. ..... . . .... ... .. ... .....Wireless External Finish ...... .. . .... . . .... . .... . MunseR'M.8/1.1
OPERATING RANGE Refrigerant Type.. .. ..... ... ... .... . ... .. . .. .......R410A
Refrigerant Pipe Size O.D.
Indoor Intake Air Temp. Outdoor Intake Air Temp. Gas Side .. ... ...........................5/8"/15.88 mm
90-F(321C)DB, 1151F(46°C)DB Liquid Side................................1/4"/6.35 mm
Maximum 731E 23°C)WB Max.Refrigerant Pipe Length....................100 ft.130 m
Cooling Max.Refrigerant Pipe Height Difference ............50 It./15 m
Minimum 671E(19`C)DB. 14`F(-10°C)DB Flared
571E(14'C)WB Connection Method .. .. . .. .. .......................
I - R
i • ;
MSY-A24NA Unit: inch
42-1/16 Installation plate Indoor unit
3-7/8 6-13/16 co
1n
00
T---------------t------------ — — o
43-5/16 n 3-7/8 16-5/16 16-5/16 6-13116
Wall hole a3
tO 10-1/4 3/16
Air in Installation plate
(V
Liquid line o1/4 19-11/16
E:=
23116 31-1/8 9-15/16 Gas line o5/816-15/16
Insulation a1-15/16 O.D
of-1/4 LID
2-511 1 1 3/4 -_ --
Drain hose o5/8
Air out (Connected part O.D)
`O I� IM Insulation of-1/8
Wireless remote controller
MUY-A24NA REQUIREDJP2Open as a rule Unit:inch
more if
20-9/32 in hole 1-/8nd both
11-25132 pen
2.19/32 1-9/16
4 inch or more/
8 inch or more if
there are obstades
to both sides
4 rn Oi
Air In Q mOre
t19-11/16 Oval holelq/n'Or or
me
33-1/16 3-3/16 Open as a rule
3 20 inch or more if the back,
both sides and top are open
Service panel
0 Liquid refrigerant
pipe joint
m Refrigerant pipe
(Flared)e1/4
'6 �, Gas refrigerant
pipe joint
Refrigerant pipe
7-25r32 (Flared)e5/8
4 MITSUBISHI
AffW ELECTRIC
HVAC Advanced Products Division
3400 Lawrenceville Suwanee Rd
Suwanee,GA 30024
nt/ Tele:678-376-2900•Fax:800-889-9904
Toll Free:800-4334822(0)
www.mehvac.com
C SD-MSY-A24NA&MUY-A24NA-200905 0 MITSUBISHI ELECTRIC/HVAC 2009 Specifications are subject to change without notice.
q � x
QJ 3 fi
10
6�
h
8
0
� 0
a
c r
4 J
0
� H
3 LU LL-
LL-
I 0
m R u L
u m
- / H L
LL
b - W O 2E
� LL. 2
CD
C�
�z
g � o
< m
S OO T
00
_ N
/ � m
W
O
7
♦I
"4 C
1
a
F of
� N
� y n
a�
0
� U
E
r
O
� N
a
0
Q
Qf—
s � N
N �
0
0
I