Loading...
HomeMy WebLinkAboutBP25-228 n 00 a N N N w H = N N N w NT--4 �4 a C 01 y tn (A bc F+1 a Lgi a TJ cn W !z O > C O ✓ v a J Q �Tz O O C) G ° b W , w M p $ 0 n F� A O w y v v p W d C o o rr� a' QI 00 00 F�j W :Ll xi O U c 1-1 c y 0, s O _ w N 00 �v w o �C' O ►-� v p G U _ A r 4z v QI z U 0�0 W s 0 u 'o Q a y L O I.-,C', N W ( h cn ai O O O w c ate ' to N V v QI/ Q W Q W a3 a �..r r o .�.� � O L d� � c 6 -d C, N cn w O w A 8 , r 14 (O� O z o a o,.b � w �p � H o 3 z w o ono as a x fn O U c ..i�wa. A U U V �- w_ z J J A W z �+ P4 O b a = mad a BUIL R MENT D VIL E OF RYE BROOK 938 KING ET RYE BRO ,NY 10573 AUG 2 12025 N/A N/A (914)939-0661P tr. � ov VILLAGE OF RYE BROOK WW* BUILDING DFPARTfi1ENT FOR OFFICE USE ONLY: 2 Approval Date: NaV 7 Q Application#� �- J Approval Signature: : ARCHITECTURAL REVIEW BOARD: Disapproved: Date: 0 BOT Approval Date: Case# n : Chairman: PB Approval Date: Jd _ QR 5 Case# Secretary: ZBA Approval Date: Case# Other: Application Fee: Permit Fees: �L EXTERIOR BUILDING PERMIT APPLICATION Application dated: I is hereby made to the Building Inspector of the Village of Rye Brook,NY,for the issuance of a Permit for the construction of buildings,stru tures,additions,alterations or for a change in use,as per detailed statement described below. 1. JobAddress: 6 Edgewood Dr. 2. Parcel ID#: 135.28-1-29 Zone: R-25 3. Proposed Improvement(Describe in detail): 1 `_ Addingapool l Re-WIOye. a H1 CL k3t.— 0 T�- 4. Property Owner: Blake Shalem Address: 6 Edgewood Dr. ,Rye Brook,NY 10573 Phone# Cell# e-mail blakepshalem@gmail.com List All Other Properties Owned in Rye Brook: Applicant: Gregory Caccioppoli,P.E. -Caccioppoli Engineering,PLLC Address: 441 Central Park Ave.,Suite 1238,Scarsdale,NY 10583 Phone# 917-309-5410 Cell# e-mail greg@caccioeng.com/ Architect: Address: Phone# Cell# e-mail Engineer: Gregory Caccioppoli,P.E. Address: 441 Central Park Ave.,Suite 1238,Scarsdale,NY 10583 Phone# 917-309-5410/914-433-5145 Cell# e-mail greg@caccioeng.com/ General Contractor: 'T-N P S)-re Ck ye I o Pryx9-yi A U C mia@caccioeng.com Address: 11 C01I01 bal-CX R.uo_ct .&„2etoetl Juhcfi0Yl Phone# Cell# e-mail TBD 6/l/2024 5. , Occupancy;(I-Fam.,2-Fam.,Commercial.,etc...)Pre-construction: Post-construction: 1-Fam 6. Area of lot: Square feet: 29,492.31 Acres: 0.68 7. Dimensions from proposed building or structure to lot lines: front yard: 182.9 rear yard: 87.04 right side yard: 28.7 left side yard: 31.3 other: 8. If building is located on a corner lot,which street does it front on: 9. Area of proposed building in square feet: Basement: N/A 11,fl: 2nd fl: 3`d fl: 10. Total Square Footage of the proposed new construction: 640 11. For additions,total square footage added:Basement: NIA I fl: N/A 2nd fl: N/A 3rd fl: N/A 12. Total Square Footage of the proposed renovation to the existing structure: N/A 13. N.Y.State Construction Classification: N/A N.Y.State Use Classification: N/A 14. Number of stories: Overall Height: Median Height: 15. Basement to be full,or partial: N/A finished or unfinished: X 16. What material is the exterior finish: N/A 17. Roof style;peaked,hip,mansard,shed,etc. N/A Roofing material: N/A 18. What system of heating: N/A 19. If private sewage disposal is necessary,approval by the Westchester County Health Department must be submitted with this application. 20. Will the proposed project require the installation of a new,or an extension/modification to an existing automatic fire suppression system?(Fire Sprinkler,ANSL System,FM-200 System,Type I Hood,etc...) Yes: No: X (f yes,applicant must submit a separate Automatic Fire Suppression Svstem Permit application&2 sets of detailed engineered plans) 21. Will the proposed project disturb 400 sq.ft.or more of land,or create 400 sq.ft.or more of impervious coverage requiring a Stormwater Management Control Permit as per§217 of Village Code? Yes: X No: Area: 2,897 22. Will the pro osed project require a Site Plan Review by the Village Planning Board as per§209 of Village Code? Yes: No: (if yes,applicant must submit a Site Plan Application,&provide detailed drawings) 23. Will the proposed project require a Steep Slopes Permit as per§213 of Village Code Yes: No: X (if yes,you must submit a Site Plan Application,&provide a detailed topographical survey) 24. Is the lot located within 100 ft.of a Wetland as per§245 of Village Code? Yes: X No: (f yes,the area of wetland and the wetland buffer zone must be properly depicted on the survey&site plan) 25. Is the lot or any portion thereof located in a Flood Plane as per the FIRM Map dated 9/28/07? Yes: X No: (if yes,the area and elevations of the flood plane must be properly depicted on the survey&site plan) 26. Will the proposed project require a Tree Removal Permit as per§235 of Village Code? Yes: No: X (if yes,applicant must submit a Tree Removal Permit Application) 27. Does the proposed project involve a Home-Occupation as per§250-38 of Village Code? Yes: No: X Indicate: TIER I: TIER II: TIER III: (if yes,a Home Occupation Permit Application is required) 28. List all zoning variances granted or denied for the subject property: N/A 29. What is the total estimated cost of construction: S I I D,O3C30_c X-> Note:The estimated cost shall include all site improvements,labor,material,scaffolding,fixed equipment,professional fees,including any material and labor which may be donated gratis.Ifthe_rnal cost exceeds the estimated cost,an additional fee will be required prior to issuance of the C/O. 30. Estimated date of completion: (2) 6/1/2024 BUILDING DEPARTMENT VILLAGE OF RYE BROOK 938 KrNG STREET RYE BROOK,NY 10573 (914)939-0668 RESIDENTIAL LOT AREA COVERAGE Address: Section: Block: Lot: PERMITTED COVERAGE RATIOS IN RESIDENTIAL DISTRICTS YOUR ZONE AREA IN MAIN ACCESS. DECK ZONE DISTRICT SQ. FEET BLDG. BLDG. MAX. CHECK MAX. R-35 35,000 14% 4% 5% X R-25 25,000 14% 3.5% 4% R-20 20,000 14% 3.5% 4% R-15 15,000 16% 3.5% 4% R-15A 15,000 12% 3.5% 4% R-12 12,500 17% 4% 4% R-10 10,000 20% 4.5% 3.5% R-7 7,500 23% 4.5% 3.5% R-5 5,000 30% 5% 3.5% R-2F 5,000 30% 5% 3.5% Existing: Proposed: 1. AREA OF LOT 29,492.31 Sq. Ft. 29,492.31 Sq. Ft. 2. AREA OF HOUSE a. Coverage of Main Building (Including Attached Garage or Accessory Building) 2,405 Sq. Ft. 2,405 Sq. Ft. b. Area of 1s'Floor Divided By Area of Lot x 100 8.2 % 8.2 % 3. AREA OF ACCESSORY BUILDING N/A N/A (Includes Detached Garages,Tool Shed, Playhouses) Sq. Ft. Sq. Ft. a. Coverage of Accessory Building Area of Accessory Building Divided By Area of Lot x 100 % % 4. AREA OF DECK 63 i Sq. Ft. 342 Sq. Ft. a. Coverage of Deck Area of Deck Divided By Area of Lot x 100 2 4 % 1.16 I attest to the best of my knowledge and belief,the above information is correct. Architect's Signature (3) 6/1/2024 BUILDING DEPARTMENT VILLAGE OF RYE BROOK 938 KING STREET RYE BROOK,NY 10573 (914)939-0668 IMPERVIOUS COVERAGE RATIOS RESIDENTIAL DISTRICTS Address: 6 Edgewood Dr. Section: 135.28 Block: I Lot: 29 Zone: R-25 IMPERVIOUS SURFACES (Definition): All buildings, as defined herein, and all areas on the ground or elevated above the ground which are comprised of materials through which water cannot readily flow, including, but not limited to asphalt, concrete, masonry, wood, gravel and clay, and which consist of elements including, but not limited to, court yards,sports courts,swimming pools,patios,sidewalks,ramps,terraces and driveways. TOTAL MAXIMUM PERMITTED MAX. PERMITTED COVERAGE Zoning IMPERVIOUS LOT AREA BY IMPERVIOUS SURFACES District COVERAGE IN FRONT (sq.ft.) For Base Lot For Lot Area YARD(%) Area(sq.ft.)* Over Base R-35 15 Lot Area % R-25 20 0 to 4,000 0 55 R-20 30 4,001 to 6,000 2,200 35 6,001 to 12,000 2,900 27 R-15 35 12,001 to 16,000 4,520 26 R-15A 35 16,001 to 20,000 5,560 25 R-12 40 20,001 to 30,000 6,560 24 30,001 to 40,000 8,960 23 R-10 45 40,001 &larger 11,260 22 R-7 40 R-5 30 *"Base Lot Area" is the minimum end of the lot size R2-F 30 range in the"Lot Area"column Area of lot: 29,492.31 sq.ft. _RgENng Allowed PrgpcWd Total impervious coverage = C402 S .ft. 6 S . ft. 5,�52 S .ft. Front impervious coverage = 18.3 % 24 % 19.5 % I attest to the best of my knowledge and belief,the above information is correct. Archi ect's Signature (4) 6/1/2024 BUILDING DEPARTMENT VILLAGE OF RYE BROOK 938 KING STREET RYE BROOK,NY 10573 (914)939-0668 BULK REGULATIONS IN RESIDENTIAL DISTRICTS Address: 6 Edgewood Dr. Section: 135.28 Block: 1 Lot: 29 MAXIMUM GROSS FLOOR AREA USE FORMULA: Maximum Gross Floor Area = 4,000 + [ (Lot Area —21,780) x 0.11478421 ]: a. Allowed = 4,885.3 Sq. Feet b. Existing = 2,405 Sq. Feet c. Proposed = 2,405 Sq. Feet HEIGHT/SETBACK RATIOS FOR RESIDENTIAL DISTRICTS DEFINITION: A standard designed to regulate the height of a building in relation to the average grade of the corresponding portion of the lot line from which it is set back. The ratio modifies the maximum permitted Height of Building by forming an inclined plane beginning at the average grade along the portion of the lot line from which the setback is measured and rising toward the building at the specified ratio above which no part of any building, other than minor architectural features such as chimneys, skylights and dormer windows not covering more than 10%of the entire roof area,shall be permitted to extend. Height and Setback shall be calculated using the formula; Height/Setback=X,where X is the required side or front yard ratio for the zoning district in which a property is located as specified in Article VI II of Chapter 250. A complete elevation view for the proposed improvement must be included on the drawings. FILL IN YOUR RATIOS: ZONE EXISTING PROPOSED REQU/IPED FRONT: FRONT: FRONT: .44 R-35 SIDE: SIDE: SIDE: 1.20 FRONT: N/A FRONT: N/A FRONT: .48 R-25 SIDE: N/A SIDE: N/A SIDE: 1.30 FRONT: FRONT: FRONT: .60 /P20 SIDE: SIDE: SIDE: 1.60 FRONT: FRONT: FRONT: .60 R-1S SIDE: SIDE: SIDE: 1.60 FRONT: FRONT: FRONT: .80 R 15A SIDE: SIDE: SIDE: 2.40 FRONT: FRONT: FRONT: .69 R 12 SIDE: SIDE: SIDE: 1.60 FRONT: FRONT: FRONT: .80 R f0 SIDE: SIDE: SIDE: 2.40 FRONT: FRONT: FRONT: .96 R-7 SIDE: SIDE: SIDE: 3.00 FRONT: FRONT: FRONT: 1.20 R5 SIDE: SIDE: SIDE: 4.00 FRONT: FRONT: FRONT: 1.20 R2F SIDE: SIDE: SIDE: 4.00 I attes to the be ,of my knowledge and belief, the above information is correct. Arc i ct's Sig at re (5) 6/1/2024 ILLUSTRATION OF HEIGHT / SETBACK RATIO Setback Line for-- I I Maximum Height I / g I Minimum REAR I / -� Setback Line I I 4 ati C for / I o LU o x .Y rn HOUSE POTENTIAL = u — — BUILDING 16 I ENVELOPE 1 FRONT Area in which Average Grade is Measured STREET Average Grade Along Property Line at Property Line ELEVATION PLAN ****************************************************************************************** Table R301.2.0) 2020 IRC CLIMATIC & GEOGRAPHIC DESIGN CRITERIA FOR RESIDENTIAL DISTRICTS IN RYE BROOK GROUND- WIND SPEED TOPOGRAPHIC SPECIAL WIND- SEISMIC DESIGN SNOW LOAD (mph) WIND EFFECTS WIND BOURNE CATAGDRY WEATHERING REGION DEBRIS ZONE 20 psf 115/120 NO NO NO 0 SEVERE FROST LINE TERMITE WINTER DESIGN ICE BARRIER FLOOD AIR FREEZING MEAN ANNUAL DEPTH PROTECTION TEMP. UNDERLAYMENT HAZARDS INDEX TEMP. REQUIRED REDUIRED 42" YES 15 YES FIRM MAP 1000 52.2 36119CO279F 8/28/07 (5a) 6/1/2024 CC BUILDDETRYEBR ENT iL V OKG2 1 2025938 KING NY 10573 - - OF RYEBROOK DEPARTfVENT AFFIDAVIT OF COMPLIANCE VILLAGE CODE §216 • STORM SEWERS AND SANITARY SEWERS THIS AFFIDAVIT MUST BEAR THE NOTARIZED SIGNATURE OF THE LEGAL PROPERTY OWNER AND BE SUBMITTED ALONG WITH ANY BUILDING OR PLUMBING PERMIT APPLICATION. ANY BUILDING OR PLUMBING PERMIT APPLICATION SUBMITTED WITHOUT THIS COMPLETED AND NOTARIZED FORM WILL BE RETURNED TO THE APPLICANT. STATE OF NEW YORK, COUNTY OF WESTCHESTER ) as: ,IJ, Blake Shalem ,residing at, 6 Edgewood Dr. (Print name) (Address where you live) being duly sworn, deposes and states that(s)he is the applicant above named,and further states that(s)he is the legal owner of the property to which this Affidavit of Compliance pertains at; 6 Edgewood Dr.,Rye Brook,NY Rye Brook,NY. (Job Address) Further that all statements contained herein are true, and that to the best of his/her knowledge and belief,that there are no known illegal cross-connections concerning either the storm sewer or sanitary sewer, and further that there are no roof drains, sump pumps, or other prohibited stormwater or groundwater connections or sources of inflow or infiltration of any kind into the sanitary sewer from the subject property in accordance with all State, County and Village Codes. / (Signature of Property Owner(s)) (Print Name of Property Owner(s)) Sworn to before me this day of 6s�f�-f , 20 '0 P lK�°fie\ r . ,.•fit:♦ (Notary Public) i /'/����lllllllll��``♦♦ (6) 6/l/2024 This application must be properly completed in its entirety by a N.Y. State Registered Architect or N.Y. State Licensed Professional Engineer & signed by those professionals where indicated. It must also include the notarized signature(s) of the legal owner(s) of the subject property, and the applicant of record in the spaces provided. Any application not properly completed in its entirety and/or not properly signed shall be deemed null and void, and will be returned to the applicant. Please note that application fees are non-refundable. ********************************************************************************************************** STATE OF NEW YORK,COUNTY OF WESTCHESTER ) as: Blake Shalem ,being duly sworn, deposes and states that he/she is the applicant above named, (print name of individual signing as the applicant) and further states that (s)he is the legal owner of the property to which this application pertains, or that (s)he is the Gregory Caccioppoli/Manal Marji for the legal owner and is duly authorized to make and file this application. (indicate architect,contractor,agent,attorney,etc.) That all statements contained herein are true to the best of his/her knowledge and belief, and that any work performed, or use conducted at the above captioned property will be in conformance with the details as set forth and contained in this application and in any accompanying approved plans and specifications,as well as in accordance with the New York State Uniform Fire Prevention&Building Code,the Code of the Village of Rye Brook and all other applicable laws,ordinances and regulations. By signing this application, the property owner further declares that he/she has inspected the subject property,and that to the best of his/her knowledge there are no roof drains, sump pumps or other prohibited stormwater or groundwater connections or sources of infiltration into the sanitary sewer system on or from the subject property. Sworn to before me this bet Sworn to before me this day of �, 20 2t' day of 520 ___ P, I - CA Sig r of roperty Owner Signature of Applicant �tX41 q Print Name of Property Owner Print Name of Applicant Notary Public Notary Public I] Al, STATF OFN,FWYORK _y ;Qualified in o, �. ge fnunh ()IMF6222473 J • n \ (g) 6/l/2024