HomeMy WebLinkAboutRB25-0041VILLAGE OF RYE BROOK - BUILDING DEPARTMENT 938 KING STREET - RYE BROOK, NY (914)939-0668 1 www.ryebrook.org Residential / (Deck) Permit PERMIT #: RB 25-0041 ISSUED: 10/01/2025 ADDRESS: 11 LONGLEDGE DR PARCEL ID #: 135.67-1-25 PARTIES: Applicant, Property owner Applicant, Project manager Mark Diamond Chris Verini 11 Longledge Dr 2309 Vista Ct Rye Brook, NY 10573Yorktown Heights, New York 10598 License number WC-38108-H24 EXPIRES: 10/02/2026 NOTICE 1. THIS MUST BE CONSPICUOUSLY POSTED2.ACOPY FIT THE PROVEEDPLANSMU TBEKEPTOTNTHE SITE. BSITE. Hours of Operation of Construction Equipment/ Village Code §158-4: WEEKDAYS - 8:00am to 6:00pm or dusk, whichever is earlier; SATURDAYS - 9:00am to 4:00pm; - SUNDAYS & HOLIDAYS -No Construction Activity Allowed This permit is valid for a period not to exceed twelve (12) months from the date of issuance, and covers only that work listed above. Separate permits are required for any electrical, plumbing, fire suppression, fire/smoke/carbon monoxide detectors/alarms, or any other work not covered under this permit. The approved plans must be kept on the job site & be made available for review by the Building Department upon demand. Any amendments or changes to the approved plans must be designed by your architect/engineer and submitted to the Building Department for review and approval prior to performing the work. 11AFA1 , k Steven E. Fews - Building & Fire Inspector p+E oar f Exterior Building Permit Application Village of Rye Brook 938 King St Rye Brook, NY 10573 Phone: (914)939-0668 1 www.ryebrook.gov Building Department Exterior Building Permit Application, page 1 / 3 Project Information Zone N.Y. State Construction Classification N.Y. State Use Classification Occupancy Pre -Construction 11 Longledge Dr PUD VB R-3 R-3 Occupancy Post -Construction Same Proposed Improvement Resurfacing an existing deck. We are removing the old pressure treated decking and railing. It will be replaced by trex composite decking materials. We will be replacing the small steps off of the deck and pouring a small concrete pad at the landing. The exact deck footprint and layout are remaining the same, we are making no major changes other than the cosmetic appearance of the deck with new material. Area of lot Dimensions from proposed building or structure to lot lines Lot Square Feet 0.0 sq.ft. Front Yard Acres 0 Rear Yard Right Side Yard Left Side Yard Other Is building located on corner lot? ❑ YES 0 NO Area of Total Square Footage of the For additions, Total Square Footage of the proposed proposed new construction: total square proposed renovation to the building in 0.0 sq.ft. footage added existing structure: square feet (0 if (0 if N/A) 0.0 sq.ft. N/A) Basement 0.0 Basement . 00 q' sq.ft. 1st Floor Oft. 1st Floor 0.0 q sq.ft. 2nd Floor aft. 2nd Floor 0.0 q sq.ft. 3rd Floor 3rd Floor 0.0 q sq.ft. Construction Type Located Pre-engineered wood Floor Framing Number of stories Overall Height Median Height 0 Basement Basement ❑ Full ❑ Partial 0 N/A ❑ Finished ❑ Unfinished 0 N/A Exterior Building Permit Application, page 2 / 3 What material is the exterior finish? Roof style Roofing material What system of heating Will the proposed project require the installation of a new, or an extension/modification to an existing automatic fire suppression system? (Fire Sprinkler, ANSL System, FM-200 System, Type I Hood, etc...) ❑ Yes 0 No Will the proposed project disturb 400 sq. ft. or more of land, or create 400 sq. ft. or more of impervious coverage requiring a Stormwater Management Control Permit as per §217 of Village Code? ❑ Yes 0 No Will the proposed project require a Site Plan Review by the Village Planning Board as per §209 of Village Code? ❑ Yes 0 No Will the proposed project require a Steep Slopes Permit as per §213 of Village Code? ❑ Yes 0 No Is the lot located within 100 ft. of a Wetland as per §245 of Village Code? ❑ Yes 0 No Is the lot or any portion thereof located in a Flood Plane as per the FIRM Map dated 9/28/07? ❑ Yes 0 No . Will the proposed project require a Tree Removal Permit as per §235 of Village Code? ❑ Yes 0 No Does the proposed project involve a Home -Occupation as per §250-38 of Village Code? ❑ Yes 0 No What is the total estimated cost of construction: Note: estimated cost shall include all site improvements, labor, 40000 USD material, scaffolding, fixed equipment, professional fees, including any material and labor which may be donated gratis. If the final cost exceeds the estimated cost, an additional fee will be required prior to issuance of the C/O. Estimated date of completion 10/01/2025 Exterior Building Permit Applicator, page 3 / 3 VILLAGE OF RYE BROOK 938 King St Rye Brook, NY 10573 Phone: (914)939-0668 1 w ..ryebrook.gov Building Department INSTRUCTIONS THE PERMIT HOLDER AND/OR PROPERTY OWNER IS RESPONSIBLE FOR ENSURING THAT ALL REQUIRED/APPLICABLE INSPECTIONS ARE SCHEDULED AND THAT THE PERMIT IS COMPLETE REQUIRED INSPECTIONS Name Description Framing Construction of all structural framing and stairs. (Rough Plumbingand Heating passed and doors, windows & roofing installed.) Engineered drawings must be provided for roof trusses. Certificate of Occupancy Completion of ALL Work, All fees Paid and Final Survey in if required) �yE 6Rnv� VILLAGE OF RYE BROOK F 2m 938 King St Rye Brook, NY 10573 W Phone: (914)939-0668 1 vmmw.ryebrook.gov >�• �O� Building Department 1962 ' Residential / (Deck) Permit Permit Set 11 LONGLEDGE DR Pit RB 25-0041 Rit 135.67-1-25 PERMIT INFORMATION Address Permit number Date issued 11 LONGLEDGE DR RB 25-0041 10/01/2025 REVIEWED BY If you have any questions regarding the review of these drawings please contact: Application in general Steven Fews stevefews@ryebrook.org INSTRUCTION ANDATTENTION It is the responsibility of the Applicant to print full size the entire approved permit package and provide at the time of inspection. TABLE OF CONTENTS Cover page 1 Building Permit 2 Required Inspections 3 Architectural drawing 4 Application Materials 5 Survey (Required Recent Survey) 6 Details drawing 7 Application Materials 8 Application Materials 9 Exterior Building Permit Application 10-12 Building Department. 938 King St Rye Brook, NY 10573 / Phone: (914)939-0668 DIAMOND RESIDENCE 11 LONGLEDGE DRIVE RYE BROOK NY 10573 PROJECT INFORMATION ARCHITECTURAL REVIEW BOARD NOTES 1) SCOPE OF WORK: A RENOVATION TO AN EXISTING DECK. WORK WILL INCLUDE NEW FINISHES, REBUILDING OF AN EXISTING STAIR, AND A NEW RAILING ASSEMBLY. a A-1.0 2) THE EXISTING FOOTPRINT, STRUCTURE, AND HEIGHTS OF THE EXISTING DECK WILL REMAIN EXACTLY AS IS. 3) ALL WORK TO COMPLY WITH GOVERNING BUILDING CODE, FIRE DEPARTMENT REGULATIONS, UTILITY COMPANY REQUIREMENTS AND THE BEST TRADE PRACTICES. APPLICABLE CODES: 2020 NEW YORK STATE RESIDENTIAL CODE DRAWING INDEX A-1.0 - TITLE PAGE, NOTES, PROPOSED PLAN, PROPOSED PARTIAL ELEVATIONS GENERAL PROJECT NOTES EXISTING FOOTINGS AND STRUCTURAL POSTS TO REMAIN AS IS EXISTING GRADE TO REMAIN EXISTING DECK TO BE REFINISHED WITH NEW DECKING, TRIMS, AND NEW RAILING ASSEMBLY NEW DECKING TO BE COMPOSITE'TREX- TRANSCEND LINEAGE'. SEE OWNER PROVIDED SAMPLES RAILING ASSEMBLY TO BE COMPOSITE TREX - TRANSCEND'. SEE OWNER PROVIDED SAMPLES / SED PLAN )�Scale: - DECK 1/4" = 1'-0" 2 r' r �v ri Scale: 1/2" = 1'-0" 1 KAIVJUCIVU Orr UVVIVCK F'KUVIUCU SAMPLES 3 rr� r �v ri Scale: 1/2" -1'-0" 1 EXISTING PICTURE - BACK Scale: 1/4" = V-0" MAILING ASSEMBLY TO BE COMPOSITE -REX - TRANSCEND'. SEE OWNER ROVIDED SAMPLES ;TAIR RAILING TO MATCH HEIGHT OF DECK ;AILING, TO BE MINIMUM 34" TO MAXIMUM 8" HEIGHT NEW STEPS WITH (4) EQUAL 7" RISERS. FINISHED TO MATCH NEW DECKING NEW CONCRETE SUPPORT PAD SAS Shand architecture studio a. 104 watch hill rd cortlandt manor ny 10567 e. jshand.sas@gmail.com p. 845-239-9923 DIAMOND RESIDENCE 11 LONGLEDGE DRIVE RYE BROOK, NY 10573 PARCEL ID: 135.67-1-25 //)NOT FOR CONSTRUCTION JOSEPH L. SHAND RA NY STATE LICENSE 4046277 NOTE: NOT VALID FOR CONSTRUCTION UNLESS SIGNED AND SEALED BY THE ARCHITECT. IT IS A VIOLATION OF NEW YORK STATE LAW TO ALTER ANY DOCUMENTS BEARING THE SEAL OF AN ARCHITECT WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. ONLY AN ARCHITECT OR ENGINEER MAY ALTER THESE SEALED DOCUMENTS AND MUST AFFIX THEIR OWN SEAL WITH NOTATION "ALTERED BY" FOLLOWED BY THEIR NAME AND DATE OF ALTERATION, WITH A CLEAR OUTLINE OF THE ALTERATION CONSULTANTS: NORTH ISSUE DATE TITLE 01 09.02.25 ARCHITECTURAL REVIEW BOARD PROJECT NUMBER: 25.021 SCALE: AS NOTED DRAWING BY: JS CHECKED BY: JS PROJECT NOTES, PROPOSED PLAN, PROPOSED ELEVATIONS ■ FIND A BUILDER RESOURCES � I SIGN IN 00 LIMITED RESIDENTIAL 35 WARRANTY YEAR omposite Railing WHERETO BUY I I FIND A BUILDER - ��iir-;I "� yy`T� \ iF Y� T � ��. •-• 'J•! i�y• . � i I ' �.'fC � ��' � , ti �� i' �n1. .i Y��.N �: -, •]+ �' � � ..2'l� J/' * � Y` '! �`•* s � T�'^!7.?77� + � M1 � A`- {r� 1 7 �+*1f'i � ,� d 'iy�, ri 4! ' # � .it• ' _ 5 a Ir � �'� I k �•�'� 'if r`� 7 •�.�t• � - �� .•j'.Tr. M �.. ry��� :�i � .w �`: ..-i'.�� a>%. wit ie. _ -� . 4 r 4 •1 r R +yy3r ..' �. - �,r.•k '� rw(- •'r. ��- �iii t'a Y '.f� ` 7r '•r 4��' L+�-T �.'1 i - �. s' + r �iR it" 7 w< Y. ,4i- _ t ' •:4 �* s y+r•r _fir- * i� r?• _ +� a }. •i, ' _•y. 1._ .'.IY. 1� f_. ;s ,R s .i'.. ryy7 Yti f ` t 1 v. � } �� ` ' {' � � .aa. '� • `� '� •2i'i • ti ��JJ fir- .{d•�• R. l i '�'. t? r3 ,r �' F� t _ �� y,• •�.F -.4 k.�''�� •r .. ,.�t'�Y i� •�i. r,' �. �~Z M1. _ -±. .' t �� �. f'^ `r• •.'i '�'�-. r� ,; ..• ^, .. :�':.. �:I �, yip "� .-. ~, � :� w#� � � 1� i. 7.t�i ',r •y.'- t `.rt �k.G-F r,Fj.� a ,. r� t _ ^ li JP P m` O s LOT 43 r �. U O my \ v qe, ra'\v O g •rxwr LOT 44 \r Drw 2 STORY AND p — 29'37rxr FRAMEDNELLING RICK R — 175.00 a �i• L — 61.32' rye 4r w N •u<K � 3 °j��•w � aa'tie s. � a �' t �•p+�' HOA 8 � ss• y er W 7°3p is. 43, w swort I rua LOT 45 This survey was prepared in accordance with the current "CODE OF PRACTICE' of the NEW YORK STATE ASSOCIATION OF PROFESSIONAL LAND SURVEYORS (NYSAPLS). All certifications Mall run to persons. named herein, for wham this survey was prepared and on their behalf to any title Company, governmental agency. or lending Institution named hereon. Said certifications are not transferable to additional institutions or subsequent owners. Any alteration or addition to this survey is a violation of SECTION 7209 of the NEW YORK STATE EDUCATION LAW, except as per SUBDIVISION 2. All certifications hereon are valid for this mop and copies thereof only if said map or copies bear the impressed seal of the surveyor whose signature appears harem. The location of underground Improvements or encroachments hereon, if any exist, are not certifle l or shown. CHAS. H. SELLS, INC. xb[/ mxsxrwa ausus .vro xs s morawuwn. ssD M. xoroxo xaD. xrcwD �xas x. ,oaa We, Chas H. Sells. Inc.. hereby certify that the survey an which this mop is Dosed was completed Or NOV. 10. 1994 and this map was completed an NOV. 11, 1994 and that said survey is in accordance with NYSAPLS current standards. CERTIFIED TO: SUSAN 1WSAN TICOR TITLE GUARANTEE CHEMICAL BANK By. CHAS. H. SELLS, INC. N.YN.Y, St I and Surveyor ----- SURVEY OF PROPERTY DESIGNATED AS LOT 44 AS SHOWN ON FILED MAP No. 23809 SITUATE IN TOWN OF RYE BROOK WESTCHESTER CO. N.Y. SCALE: 1" = 20' NOV. 11, 1994 NO LINES OF POSSESSION OTHER THAN INDICATED Job No.BB-079 // tiara-�,fpi if47-1 - 10:11 AM TueSep 2 0 0 * buy. adva rota g e l u m ber.00m oil IFI, 100% �' IP 144 1111111 J 11 I 11 1I IT'us�77'\ A � TREX" SKU: CTHatt540EPG-Sample Trex Transcend Li"neageg Decking $0.00 USD - Shipping calculated at checkout. Board Color: Hatteras 310 Profile: 1x6 Grooved Y�f Length: Sample 12 Feet uartity Get a Quote 16 Square 16 Feet 20 Feet Add to cart Trex Transcendt LineageTM Composite Decking ,fr • r Mph, I.,Zo �' t Fr dFm 4 oor 0