HomeMy WebLinkAboutRB25-0028PERMIT #:
/_l91917��'A
PARCEL ID #:
PARTIES:
VILLAGE OF RYE BROOK - BUILDING DEPARTMENT
938 KING STREET - RYE BROOK, NY
(914)939-0668 1 www.ryebrook.org
HVAC Permit
RB 25-0028 ISSUED: 08/26/2025 EXPIRES: 08/26/2026
KL! 3!!!!y_111.41a]
WZAW19151 S3
Applicant Property owner
Arctic Mechanical Lisa Levine
Mark Pauletti 34 Bellefair Rd
460 N. Main St. Rye Brook, NY 10573
Port Chester, NY 10573
License number WC-18510-1-106
NOTICE 2.ACIOPYOFIT MUST BEEA PROVEDPLANSOUSLY MU TBEEKEPTOPOSTEDTNTHE SITE. BSITE.
Hours of Operation of Construction Equipment/ Village Code §158-4: WEEKDAYS - 8:00am to 6:00pm or dusk, whichever is earlier;
SATURDAYS - 9:00am to 4:00pm; - SUNDAYS & HOLIDAYS -No Construction Activity Allowed
This permit is valid for a period not to exceed twelve (12) months from the date of issuance, and covers only that work listed above. Separate permits are required for any
electrical, plumbing, fire suppression, fire/smoke%arbon monoxide detectors/alarms, or any other work not covered under this permit. The approved plans must be kept on
the job site & be made available for review by the Building Department upon demand. Any amendments or changes to the approved plans must be designed by your
architect/engineer and submitted to the Building Department for review and approval prior to performing the work.
Steven E. Fews - Building & Fire Inspector
6Rnv�
VILLAGE OF RYE BROOK
�yE
F
2m
938 King St Rye Brook, NY 10573
W
Phone: (914)939-0668 1 vmw.ryebrook.gov
>�• �o�
1962 '
Building Department
HVAC Permit
Permit Set 34 BELLEFAIR RD P# RB 25-0028 R# 124.73-1-63
PERMIT INFORMATION
Address Permit number Date issued
34BELLEFAIR RD RB25-0028 08/26/2025
REVIEWED BY
If you have any questions regarding the review of these drawings please contact:
Application in general
Steven Fews
stevefews@ryebrook.org
INSTRUCTION ANDATTENTION
It is the responsibility of the Applicant to print full size the entire approved permit package and provide at the time of inspection.
TABLE OF CONTENTS
Cover page 1
Building Permit 2
Required Inspections
3
Site plan
4-5
Application Materials
6-13
Application Materials
14-35
Application Materials
36
HVAC Permit Application
37
Building Department. 938 King St Rye Brook, NY 10573 / Phone: (914)939-0668
VILLAGE OF RYE BROOK
938 King St Rye Brook, NY 10573
Phone: (914)939-0668 1 w ..ryebrook.gov
Building Department
INSTRUCTIONS
THE PERMIT HOLDER AND/OR PROPERTY OWNER IS RESPONSIBLE FOR ENSURING THAT ALL REQUIRED/APPLICABLE INSPECTIONS ARE SCHEDULED AND THAT
THE PERMIT IS COMPLETE
REQUIRED INSPECTIONS
Name
Final Inspection
Final Electric
Description
Completion of all required items under the permit including the site grading and the surveyor's final grading
certificate.
Final Electric
VILLAGE OF RYE BROOK - BUILDING DEPARTMENT
938 KING STREET - RYE BROOK, NY
(914)939-0668 1 www.ryebrook.org
Electrical / New Fixtures And Wiring (Remodel) Permit
PERMIT #: RB 25-0043
ADDRESS: 34 BELLEFAI R RD
PARCEL ID #: 124.73-1-63
PARTIES:
Applicant, Electrical contractor
JBG Electric Corp
ISSUED:
Francisco Barajas
24 WALNUT STREET
NEW ROCHELLE, NEW YORK 10801
08/28/2025 EXPIRES: 08/27/2026
Property owner
Lisa Levine
34 Bellefair Rd
Rye Brook, NY 10573
NOTICE 1. THIS MUST BE CONSPICUOUSLY POSTED2.ACOPY OFIT EAPPROVEEDPLANSMU TBEEKEPTOTNTHE SITE. BSITE.
Hours of Operation of Construction Equipment/ Village Code §158-4: WEEKDAYS - 8:00am to 6:00pm or dusk, whichever is earlier;
SATURDAYS - 9:00am to 4:00pm; - SUNDAYS & HOLIDAYS -No Construction Activity Allowed
This permit is valid for a period not to exceed twelve (12) months from the date of issuance, and covers only that work listed above. Separate permits are required for any
electrical, plumbing, fire suppression, fire/smoke/carbon monoxide detectors/alarms, or any other work not covered under this permit. The approved plans must be kept on
the job site & be made available for review by the Building Department upon demand. Any amendments or changes to the approved plans must be designed by your
architect/engineer and submitted to the Building Department for review and approval prior to performing the work.
Steven E. Fews - Building & Fire Inspector
STATE WIDE INSPECTION SERVICES, IINN
r•r
r t
Office Use
Elect. Permit #
Date
Bldg Permit #
Sq Ft
Plumbing Permit #
Final Certificate #
City / Village i%, r� �
Zip
Building Dept.
County
Address
Cross Street
Section
Block Lot
Owner Name / Address (If different than above)
Contact Number
❑ Basement ❑ 1st Ft. ❑ 2nd FL ❑ 3rd FI. ❑ More Than 3 FI. ❑ Garage ❑ Attic ❑ Outside ❑ Residential ❑ Commercial
Receptacles
Special Recept
GFCI
AFCI
Switches
Dimmers
Smoke Alarms
C / 0 Detector
Hood
Trash compact
Amt Amps
Range (s)
Cooktop (s)
Oven (s)
Dishwashers
Refrigerator
Disposal
Microwave
Luminaires
Generator
Transfer Switc
SERVICE
Amperage
#Panels
1P
3P
# Meters
# Disconnect
❑ Underground I
❑ Overhead
❑ New ❑ Reconnect ❑ Repair
❑ Upgrade ❑ Disconnect
Utility ID# ❑ Con Ed ❑ NYSEG ❑ Central Hudson ❑ Orange / Rocklanc
PHOTOVOLTAIC SYSTEM
PV Modules
Inverters
AC Disconnect
Junction Box
I Combiner Box
Load Center
PV Monitor
Energy Storage System
DC Disconnect
❑ Legalization ❑ Safety Inspection ❑ Consultation
This application Is valid fort ne (n yearmom the date received by SWIS. This application is Intended to cover the above listed Items to he Inspected Nat any time pi Inspection additional items have been installed, you are
authorlred to make the inspection and adjust thefee for the additional Items Inspected.The applicant declares that there Is no open applications for due above address with any other Inspection company.the applicant,
caner orauahorired agent agrees to all the above terms and conditions as satforth for the application.
Email Address �40 ' e l{(�,ci V( L p
,L
Name PC- (c11%
License # % (is f(
Date �' L Y
Signature ,
Address "� rvq (11U4r
City / State 1 K' Lo "(I Zip Code
Company -� E t4 Cv-J).
I Phone# (?ILI r7k. igr
�f Electrical Permit Application Village of Rye Brook
938 King St Rye Brook, NY 10573
Phone: (914)939-0668 1 www.ryebrook.gov
Building Department
Project Information rM
SBL
Zone
PUD
Proposed Electrical Work/Fixture Count
3rd Party Electrical Inspection Agency
Wiring mechanical unit
Master Electrician/Licensed Installer Information
Name Lic # Address email
FRANCISCO BARAJAS 1868 24 WALNUT STREET NEW ROCHELLE NY INFO@JBGELECTRICCORP.COM
Phone # Cell # Company Name Company Address
9144380282 JBG ELECTRIC CORP 24 WALNUT STREET, NEW ROCHELLE NY
Address of Work?
Homeowner Information
34 Bellefair Rd, Rye Brook
Electrical Permit Application, page 1 / 1
VILLAGE OF RYE BROOK
938 King St Rye Brook, NY 10573
Phone: (914)939-0668 1 w ..ryebrook.gov
Building Department
INSTRUCTIONS
THE PERMIT HOLDER AND/OR PROPERTY OWNER IS RESPONSIBLE FOR ENSURING THAT ALL REQUIRED/APPLICABLE INSPECTIONS ARE SCHEDULED AND THAT
THE PERMIT IS COMPLETE
INSPECTIONS
Name
Description
Final Inspection Completion of all required items underthe permit includingthe sitegradingand the surveyor'sfinal grading
certificate.
�yE 6Rnv� VILLAGE OF RYE BROOK
F
2m 938 King St Rye Brook, NY 10573
W
Phone: (914)939-0668 1 vmw.ryebrook.gov
>�• �O� Building Department
1962 '
Electrical / New Fixtures And Wiring (Remodel) Permit
Permit Set 34 BELLEFAIR RD P# RB 25-0043 R# 124.73-1-63
PERMIT INFORMATION
Address Permit number Date issued
34BELLEFAIR RD RB25-0043 08/28/2025
REVIEWED BY
If you have any questions regarding the review of these drawings please contact:
Application in general
Steven Fews
stevefews@ryebrook.org
INSTRUCTION ANDATTENTION
It is the responsibility of the Applicant to print full size the entire approved permit package and provide at the time of inspection.
TABLE OF CONTENTS
Cover page 1
Building Permit 2
Required Inspections 3
Copy of Electrical License 4
3rd Party Electrical Inspection Form 5
Electrical Permit Application 6
Building Department. 938 King St Rye Brook, NY 10573 / Phone: (914)939-0668
OnCallAir proposal builder
,n
lox ML14KC AC 3.5 Ton
EQUIPMENT Quantity: 2
Category: Condenser
Lennox, Merit, 3.5 Ton, Air Conditioner
ML34KC1-042- Catalog # 25C93
- Efficiency rating meets or exceeds energy efficiencies of.14.30. SEER2. - ENERGY STAR® Certified - meets or exceeds federal
guidelines for energy -efficient performance. - Federal Tax Credit Eligible - this product is eligible for the Energy Efficient Home...
Category: Evaporator Coil
Lennox, Cased Upflow, 4Ton, Evap Coil
CK40CT-48C - Cat # : 25 u 82
CK40CT. -01 Indoor Evaporator Coil. Up -flow, full -cased R-410A models, convertible to R-454B at time of initial installation. For every
application and configuration, our cooling coils are the perfect choice. Introducing. CK40CT -01 up -flow evaporator coils by Lennox,...
ACCESSORIES Quantity: 3
Category: HVAC Add-Ons
NLocking Refrigerant caps
CUSTOM-26YYUX / Quantity: 1
- Secure Seal: These 1/4 inch locking caps provide a secure, airtight seal for HVAC systems and refrigerant lines. - Durable
Construction: Crafted from high -quality materials, these caps are designed for long-lasting performance. - Easy Installatio...
Category: HVAC Add-Ons
Re -pipe PVC Condensate drain line
CUSTOM-3G8M19 / Quantity: I
Re -pipe Condensate drain line from unit to drain.
Category: HVAC Add-Ons
CUSSuid tM-AQht A/C Whip
CUSTOM-AQKL06 / Quantity:l
Liquid -tight flexible conduit system. A labor saving convenience kit for A/C unit hookup. Also used for heat pumps,
refrigeration, hot tubs, swimming pools and outdoor lighting. Three distinct wire colors for ease of hook-up.1 straight and...
WHAT YOU'LL GET Quantity: 6
Arctic Mechanical Guarantee on Workmanship & 24/7 Service Department: We offer a One -Year Parts and One -Year Labor Warranty
on all our HVAC services and installations. This guarantee ensures that any issues related to the quality of workmanship or materials
used are addressed at no additional cost within the first year. Additionally, you will be backed by Arctic Mechanical's 24/7 Service
Department, ensuring that assistance is available whenever you need it, giving you peace of mind and confidence in the durability and
reliability of our work.
Complete System Startup: A thorough initialization of the HVAC system, ensuring all components operate correctly according to the
manufacturer's specifications. This includes testing the heating, cooling, and ventilation functions for optimal performance and
confirming that the system meets warranty requirements. With regard to AC lines the existing lines will be flushed pressure tested for
leaks and reconnected unless otherwise specified. If during testing procedure The AC lines do not hold pressure they will be
abandoned, and a new set will be ran at an additional cost based on time and material.
Line and Low Voltage Electrical Reconnections: Re-establishing connectionsfor both line and low voltage electrical systems to ensure
proper functionality and safety.
https://app.oncallair.com/print/publ!cJl 710897/4533161?customerToken=ccc3l26e6a9787eca26d7fcaf3edc650d28626092e50f661361 f12e 1 d b70dc71... 215
7128125, 9:37 AM
OnCall Air proposal builder
r ie Arctic -Mechanical Heating & Cooling
Your Proposal
Option 2.
Customer. Lisa & Doug Levine
Address: 34 Bellefair Road Rye Brook, NY 10573
Phone: 1914) 319-8294
Email: I i sad levi neCagmai I.com
Consultation Code: ENG86AIY7
Date Presented: Jul 26, 2025
Date Accepted: Jul 26, 2025
Presented by: Jeffrey Feist
Phone:j914)934-8301
Email: jgffrey_@arctic-mecha nical.com
CALLUS TODAY
(914) 934-8301
Experience top -tier HVAC solutions with Arctic Mechanical. Established in 1997, we specialize in comprehensive HVAC services across
Westchester and Fairfield Counties. From heating and ventilation to air conditioning repair and installation, we've got you covered.
Backed by a skilled team of 27 professionals, we tackle diverse commercial and residential HVAC projects with precision and expertise.
At Arctic Mechanical, our mission is to surpass your expectations. We not only deliver exceptional heating and air conditioning services
but also foster enduring business relationships based on the integrity of our team. Count onus for top-quality workmanship and an
unparalleled customer experience.
•@` MEq�C'4
LENN[X,
rRavE PREMIER % c CONTRACTOR
DEALER' 00 NTRACTOR
V EALE 1 \ eU 1.
Its Xm'ff TO Ship fl. iiGRE: HEATING AIR CONDITIONING
r�Y tACE �
000SMith.
Discover Arctic -Mechanical Heating& Cooling! i' Watch our YouTu be video to learn more about our services and expertise. Click the
link in the image to watch now!
1N"(1111M
°�
Home Improvement Contractor Westchester License #WC-18510-H06 Connecticut License # 0638204
PROPOSAL NOTE
Note: actual town permit fees will be built in addition to this proposal at cost once we pull the permits.
I can take $500 off the cost of the job if you pay for this via check.
https:I/app.oncallair.com/printlpublic/17l O897/4533161?customerToken=crc3l26e6a9787eca26d7fc8f3edc65Od28626092e5Of661361 f l2e t db7Odc7l ... 1 /5
OnCall Air proposal builder
.1m
atox ML14KC AC 3.5 Ton
EQUIPMENT Quantity: 2
Category: Condenser
Lennox, Merit, 3.5 Ton, Air Conditioner
ML14KC1-042- Catalog # 25C93
-Efficiency rating meets or exceeds energy efficiencies of.14.30. SEER2. -ENERGY STAR& Certified -meets or exceeds federal
guidelines for energy -efficient performance. -Federal Tax Credit Eligible -this product is eligible for the Energy Efficient Home...
Category: Evaporator Coil
Lennox, Cased Upflow, 4 Ton, Evap Coil
CK40CT-48C - Cat # r25 u 82
CK40CT. -01 Indoor Evaporator Coil. Up -flow, full -cased R-410A models, convertible to R-454B at time of initial installation. For every
application and configuration, our cooling coils are the perfect choice. Introducing. CK40CT -01 up -flow evaporator coils by Lennox,...
ACCESSORIES Quantity: 3
Category: HVAC Add-Ons
Locking Refrigerant caps
toCUSTOM-26YYUX / Quantity: 1
- Secure Seal: These 1/4 inch locking caps provide a secure, airtight seal for HVAC systems and refrigerant lines. - Durable
Construction: Crafted from high -quality materials, these caps are designed for long-lasting performance. - Easy Installatio...
Category: HVAC Add-Ons
Re -pipe PVC Condensate drain line
CUSTOM-3G8M19 / Quantity: 1
Re -pipe Condensate drain line from unit to drain.
Category: HVAC Add-Ons
CUSSuid tM-AQht A/C Whip -
CUSTOM-AQKLO6 /Quantity: 1
Liquid -tight flexible conduit system. A labor saving convenience kit for A/C unit hookup. Also used for heat pumps,
refrigeration, hot tubs, swimming pools and outdoor lighting. Three distinct wire colors for ease of hook-up.1 straight and ...
WHAT YOU'LL GET Quantity: 6
Arctic Mechanical Guarantee on Workmanship & 24/7 Service Department: We offer a One -Year Parts and One -Year Labor Warranty
on all our HVAC services and installations. This guarantee ensures that any issues related to the quality of workmanship or materials
used are addressed at no additional cost within the first year. Additionally, you will be backed by Arctic Mechanical's 24/7 Service
Department, ensuring that assistance is available whenever you need it, giving you peace of mind and confidence in the durability and
reliability of our work.
Complete System Startup: A thorough initialization of the HVAC system, ensuring all components operate correctly according to the
manufacturer's specifications. This includes testing the heating, cooling, and ventilation functions for optimal performance and
confirming that the system meets warranty requirements. With regard to AC lines the existing lines will be flushed pressure tested for
leaks and reconnected unless otherwise specified. If during testing procedure The AC lines do not hold pressure they will be
abandoned, and a new set will be ran at an additional cost based on time and material.
Line and Low Voltage Electrical Reconnections: Re-establishing connections for both line and low voltage electrical systems to ensure
proper functionality and safety.
httpsliapp.oneallair.com/print/public/l710897/4533161?customerToken=ccc3126e6a9787eca26d7fc8f3edc650d28626092e50f661361 f 12e 1 db70dc71... 2/5
C
r-
R
:i
D A
O o
Z
O
S ;u
m =
m D
Z
Z
m
v m
w
D O
C
C)
� ro
m r.t
Z_ C
0 fD
D
r
Z CD
o
O
X
TO n
N
m
O fD
n
n
A� h® CERTIFICATE OF LIABILITY INSURANCE
DATE IMM/DD/YYYY)
1211412024
THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE
DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF
INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE
CERTIFICATE HOLDER.
IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed. If
SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this
Certificate does not confer rights to the certificate holder in lieu of such endorsement(s).
PRODUCER
FEDERATED MUTUAL INSURANCE COMPANY
HOME OFFICE: P.O. BOX 328
CONTACT
NAME: CLIENT CONTACT CENTER
PMORE
(A1C, 11% Exl1: 858-3334949 (ArO, R.)-. 5074415-46611
OWATONNA, MN 55M
AD AEss:CLIENTCONTACTCENTER FEDINS.COM
INSURERS AFFORDING COVERAGE
RAW#
INSURER A:FEDERATED MUTUAL INSURANCE COMPANY
13935
INSURED
INSURER B: FEDERATED RESERVE INSURANCE COMPANY
16024
ARCTIC MECHANICAL INCORPORATED
460 N MAIN ST
INSURER C:
INSURER IX.
PORT CHESTER, NY 10573-310
INSURER E:
INSURER F:
COVERAGES CERTIFICATE NUMBER: 90 REVISION NUMBER 0
THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED,
NOTWITHSTANDING ANY REQUIREMENT. TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE
ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF
SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS.
INSR
LTR
TYPE OF INSURANCE
ADDL
INSR
SUBR
V/VO
PoLK:Y NUMBER
POLICY EFT
MAYDDIYYY
POUCY EXP
MM1DD
LIMITS
A
X
COMMERgA GENERAL LIA&LITY
CWMSiAOCCUR
N
N
1887386
01/18/2025
01/18/2026
EACH OCCURRENCE
$1,000,000
ETENTED PREMISES
F. oeaE TO O
$100,000
MED EXP I"amp MIN*
EXCLUDED
PERSOXALAADVINJURY
$1000000
OENL
X
AGGREGATE UNIT APPLIES PER:
POLICY EC° ❑ LOC
OTHER: LL�JJY"
GENERA-AGOREGATE
$2000000
PRODUCTS & COMPIOP ACC
$2.000,000
AOWNED
AUTOMOBILE LIABILITY
AYAUTOEDGILY
AUTOS ONLY SSCHEEDDULED
AUT
JN
HIRED AUTOS ONLY BaI D
N
N
1887386
01/18/2025
01/18/2026
COM."dWINGLE LIMIT
$1,ODO,000
INJURY(Per Pemn)
BOOILY INJURY(Per .AcddmQ
Per RTY AMAGE
A
X
UMBRELLA UA9
EXCESS LIMB
X OCCUR
CLAIMSd ADE
N
N
9907994
01/16/2025
01/18/2026
EACH OCCURRENCE
$5,000,000
AGGREGATE
$5,000,000
DED X RETENTION E10,000
g
WORKERS COMPENSATION
AND EMPLOYERS' LIABILITY YIN
ANY PROPRIETOWPARTNERI EXECUTIVE
OFRCERIMEMBER EXCLUDED?
(Mandatory in NH)
If Yea, describe ender
DESCRIPTION OF OPERATIONS below
N/A
N
9298530
01/18/2025
01/18/2026
X PER STATUTE HER
E.L EACH ACCIDENT
$1,000,000
E.L DISEASE EA EMPLOYEE
$1,000,ODO
E.L DISEASE - POLICY LIMIT
$1,000,1300
DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES (ACORD 101, AddNNW Remaft SdwduIe, may be a1GGNd If more space is required)
938 KING ST
RYE BROOK, NY 10573-1226
90 0 I SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED
BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN
ACCORDANCE WITH THE POLICY PROVISIONS.
AUTHORIZED REPRESENTATIVE
O 1988-2015 ACORD CORPORATION. All rights reserved.
ACORD 25 (2016703) The ACORD name and logo are registered marks of ACORD
NEW Workers'
STATE Compensation
Board
CERTIFICATE OF
NYS WORKERS' COMPENSATION INSURANCE COVERAGE
1a. Legal Name & Address of Insured (use street address only)
1b. Business Telephone Number of Insured
(914)934-8301
Arctic Mechanical Incorporated 2864684
460 N Main St
Port Chester, NY 10673-3310
1c. NYS Unemployment Insurance Employer Registration Number of
Insured
Work Location of Insured (Only required ff coverage is spedficallyfimfted to
1d. Federal Employer Identification Number of Insured or Social Security
certain locations in New York State, i.e., a Wrap -Up Policy)
Number
D6-1596446
2. Name and Address of Entity Requesting Proof of Coverage
3a. Name of Insurance Carrier
(Entity Being Listed as the Certificate Holder)
Federated Reserve Insurance Company
Village Of Rye Brook
31b. Policy Number of Entity Listed in Box 1 a"
938 ring St
9298530
Rye Brook, NY 10573-1226
3c. Policy effective period
01/18/2025 to 01/182026
3d. The Proprietor, Partners or Executive Officers are
❑X included. (Only check box if all partnersromcers included)
all excluded or certain partners/officers excluded.
This certifies that the insurance carrier indicated above in box "3" insures the business referenced above in box "1 a" for workers'
compensation under the New York State Workers' Compensation Law. (To use this form, New York (NY) must be listed under Item 3A
on the INFORMATION PAGE of the workers' compensation insurance policy). The Insurance Carrier or its licensed agent will send
this Certificate of Insurance to the entity listed above as the certificate holder in box "2".
The insurance carrier must notify the above certificate holder and the Workers' Compensation Board within 10 days IF a policy is canceled
due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or
eliminate the insured from the coverage indicated on this Certificate. (These notices may be sent by regular mail.) Otherwise, this
Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent, or until the policy
expiration date listed in box "3c", whichever is earlier.
This certificate is issued as a matter of information only and confers no rights upon the certificate holder. This certificate does not amend,
extend or alter the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond those contained in the
referenced policy.
This certificate may be used as evidence of a Workers' Compensation contract of insurance only while the underlying policy is in effect.
Please Note: Upon cancellation of the workers' compensation policy indicated on this form, if the business continues to be
named on a permit, license or contract issued by a certificate holder, the business must provide that certificate holder with a
new Certificate of Workers' Compensation Coverage or other authorized proof that the business is complying with the
mandatory coverage requirements of the New York State Workers' Compensation Law.
Under penalty of perjury, I certify that I am an authorized representative or licensed agent of the insurance carrier referenced
above and that the named insured has the coverage as depicted on this form.
Approved by: Melissa
name of authorized representative or licensed agent of insurance carrier)
Approved by:
Title: Authorized Representative
121142024
(Date)
Telephone Number of authorized representative or licensed agent of insurance carrier: 888-333-4949
Please Note: Only insurance carriers and their licensed agents are authorized to issue Form C-105.2. Insurance brokers are NOT
authorized to issue it.
C-105.2 (9-17) www.wcb.ny.gov
ML14KC1
MERIT® SERIES
Single -Stage I Quantum' Coil 11-Phase 1 60Hz
RESIDENTIAL
PRODUCT SPECIFICATIONS (EHB)
MODEL NUMBER IDENTIFICATION
Product Tier L--------
M L = Merit- Series
Nominal SEER2 -
14=14.0 to 14.9 SEER
ML14KC1
r �
i
i
Refrigerant Type -------- ;
K = R-4546 1 1
r i
r
Unit Type---------
C = Air Conditioner (Condenser)
Cooling Stages --------
I =SingleStage Compressor
AIR CONDITIONERS
LENNOX
1.5 to 5 Tons
SEER2 up to 17.0
Cooling Capacity 117,000 to 60,000 Btuh
MERIT®
SERIES
Q
LENNOX
QUANTUM"
COIL
2025 COMPLIANT
REFRIGERANT
-036-230A01
--------Revision level
i r
i r
i r
•-------- Ratites Revision LeLelj
------Voltage
230 = 208/23OV-1 phase-60Hz
---• Nominal Cooling Capacity
018 = 1.5 tons
024 = 2 tons
030 = 2.5 tons
036 = 3 tons
041 = 3.5 tons
042 = 3.5 tons
047 = 4 tons
048 = 4 tons
L059 = 5 tons
060 = 5 tons
Form Number 2110581 June 2025
Supersedes all previous versions
FEATURE HIGHLIGHTS
1. Outdoor Coil Fan
2. Quantum' Coil
3. Scroll Compressor
4. Heavy Gauge Steel Cabinet
5. Refrigerant Line Connections and Access
CONTENTS
Approvals And Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . 3
Dimensions -Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . 9
Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . 7
Expanded Sound Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . 10
Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . 3
Field Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . 10
Installation Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . 10
Model Number identification . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . 1
Optional Accessories - Order Separately . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . 7
Optional Controls - Order Separately . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . 7
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TXV Substitution - R-454B . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . 11
TXVUsage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . 11
ML1 4KC1 11.5 to 5 Ton Air Conditioner I Page 2
APPROVALS AND WARRANTY
APPROVALS
• AHRI Standard 210/240-2023 certified
• AHRI Certified system match -ups and expanded ratings, visit www.LennoxPros.com
• ENERGY STAR® Certified
Sound rated to AHRI Standard 270-2008 test conditions
Tested in Lennox Research Laboratory environmental test room
Rated According to U.S. Department of Energy (DOE) test procedures
Region specific models meet the minimum efficiency requirements for U.S. DOE Federal Regional Standards in that area
Unit and components ETL, NEC and CEC bonded for grounding to meet safety standards for servicing
ETL certified (U.S. and Canada)
ISO 9001 Registered Manufacturing Quality System
WARRANTY
Compressor:
• Limited five years in residential installations
• Limited five years in non-residential installations
All other covered components:
• Limited five years in residential installations
• Limited one year in non-residential installations
NOTE - Refer to Lennox® Basic Limited Warranty at www Lennox com for additional details.
FEATURES
APPLICATIONS 0 Quantum- Coil
• 1.5 through 5 tons • Lennox designed and fabricated coil
• Sound levels as low as 73 dBA • Enhanced aluminum alloy tube/enhanced fin coil
Single-phase power supply
Vertical air discharge
Applicable to indoor air handlers or gas furnaces with
indoor add -on coils
Shipped completely factory assembled, piped and wired
REFRIGERATION SYSTEM
R-454B Refrigerant
• Low GWP (Global Warming Potential)
• Zero ODP (Ozone Depletion Potential)
• Low Toxicity/Lower Flammability -A2L
• Unit is factory pre -charged
NOTE -Total system refrigerant charge is dependent on
outdoor unit size, indoor unit size and refrigerant
line length.
NOTE - Refer to the unit -mounted charging stickerto
determine correct amount of charge required.
O Outdoor Coil Fan
• Direct drive fan
• Vertical air discharge
• Totally enclosed fan motor
• Ball bearings
• Inherently protected
• Motor rain shield
• Louvered steel fan guard
Superior corrosion resistance
Ripple -edged aluminum fins
Aluminum tube construction
• Lanced fins for maximum fin surface exposure
• Fin collars grip tubing for maximum contact area
• Flared shoulder tubing connections
• Factory tested under high pressure
• Entire coil is accessible for cleaning
High Capacity Liquid Line Drier
• Furnished with unit for field installation
• Traps any moisture or dirt that could contaminate the
refrigerant system
• 100% molecular -sieve, bead type
High Pressure Switch
• Protects the system from high pressure conditions that
can be a result of fan failure or a blocked/dirty coil
• Automatic reset
Low Pressure Switch
• Shuts off unit if suction pressure falls below setting
• Provides loss of charge and freeze-up protection
• Automatic reset
ML14KC1 11.5 to 5 Ton Air CondRbner I Page 3
FEATURES
REFRIGERATION SYSTEM (Continued)
Optional Accessories
Expansion Valve Kits
• Field installed on indoor units (if required)
See TXV Usage table
Chatleff-style fitting
Freezestat
• Senses suction line temperature
• Cycles compressor off when suction line temperature
falls below freezestat setpoint
• Opens at 29°F and closes at 58°F
• Installs on or near the discharge line of the evaporator or
on the suction line
Loss of Charge Switch Kit
• Protects compressor from damage from low refrigerant
charge conditions
• SPST, normally -closed
• Automatic reset
Refrigerant Line Kits
• Refrigerant lines are shipped refrigeration clean
• Lines are cleaned, dried, pressurized and sealed at
factory
Suction line fully insulated
Lines are stubbed at both ends
INDOOR REFRIGERANT DETECTION SYSTEM (RDS)
• Complies with UL 60335-2-40 approved standard
• Required for all systems using R-454B refrigerant
• Factory or field installed on all indoor units
• Consists of a RDS refrigerant detection sensor and a
mitigation control in the indoor unit
• Ensures safe operation for systems equipped with
R-454B refrigerant
• Indoor sensor will detect any R-454B refrigerant
• If R-454B refrigerant is detected, the refrigerant
detection system will stop compressor operation and
operate the blowerto reduce concentrations in the
conditioned space
• Once safe levels are reached the HVAC system will
resume normal operation
• Refer to indoor unit Product Specifications documents
for additional details
® Single -Stage Scroll Compressor
• High volumetric efficiency
• Uniform suction flow
• Constant discharge flow
• Quiet operation
• Low gas pulses during
compression reduces operational
sound levels
• Compressor motor is internally
protected from excessive current
and temperature
• Muffler in discharge line reduces
operating sound levels
• Compressor is installed in the unit on resilient rubber
mounts for vibration free operation
Scroll Compressor Operation
Two involute spiral scrolls matched together generate a
series of crescent -shaped gas pockets between them
During compression, one scroll remains stationary while
the other scroll orbits around it
Gas is drawn into the outer pocket, the pocket is sealed
as the scroll rotates
As the spiral movement continues, gas pockets are
pushed to the center of the scrolls. Volume between the
pockets is simultaneously reduced
When the pocket reaches the center, gas is now at high
pressure and is forced out of a port located in the center
of the fixed scrolls
During compression, several pockets are compressed
simultaneously resulting in a smooth continuous
compression cycle
Continuous flank contact, maintained by centrifugal
force, minimizes gas leakage and maximizes efficiency
Compressor is tolerant to the effects of slugging and
contaminants. If this occurs, scrolls separate, allowing
liquid or contaminants to be worked toward the center
and discharged
Compressor Crankcase Heater
(041 through 060 Models)
• Prevents migration of liquid refrigerant into compressor
and ensures proper compressor lubrication
Optional Accessories
Compressor Crankcase Heater
(018 through 036 Models)
• Prevents migration of liquid refrigerant into compressor
and ensures proper compressor lubrication
Compressor Sound Cover
• Reinforced vinyl compressor cover
• 1-1 /2 inch thick batt fiberglass insulation
All open edges are sealed with a one -inch wide hook and
loop fastening tape
ML141KC1 11.5 to 5 Ton Air Conditioner I Page 4
FEATURES
COMPRESSOR (continued)
Optional Accessories (continued)
Compressor Hard Start Kit
• Single-phase units are equipped with a PSC compressor
motor
• This type of motor normally does not need a potential
relay and start capacitor
• For conditions such as low voltage, kit may be required
to increase the compressor starting torque
Compressor Low Ambient Cut -Off Switch
• Non-adjustable switch (low ambient cut-out)
• Prevents compressor operation when outdoor
temperature is below 35°F
Compressor Time -Off Control
• Kit prevents compressor short -cycling
• Allows time for suction and discharge pressure to
equalize.
• Permits compressor start-up in an unloaded condition.
Automatic reset with 5 minute delay between
compressor shut-off and start-up
CONTROLS
Optional Accessories
M30 Smart Wi-Fi Thermostat
• Wi-Fi-enabled, electronic 7-day, universal, muhi-stage,
programmable, touchscreen thermostat
• 4 Heat/2 Cool
• Auto -changeover
• Dual -fuel control with
optional outdoor sensor
• Controls dehumidification
during cooling mode and
humidification during
heating mode
• Offers enhanced capabilities including humidification /
dehumidification / dewpoint measurement and control,
Humiditrol® control, and equipment maintenance
reminders
• Easy to read 4.3 in. color touchscreen (measured
diagonally)
• LCD display with backlight shows the current and set
temperature, time, inside relative humidity, system
status (operating mode and schedules) and outside
temperature (optional outdoor sensor required)
• Smooth Setback Recovery starts system early to
achieve setpoint at start of program period
• Compressor short -cycle protection (5 minutes)
• Up to four separate schedules are available plus
Schedule IQ'
• One -Touch Away Mode - A quick and easy way to set the
cooling and heating setpoints while away
• Smart Away'" - Uses geo-fencing technology
to determine when the homeowner is within a
predetermined distance from the home to operate the
system when leaving, away and arriving
• Wi-Fi remote monitoring and adjustment through a
home wireless network for desktop PCs, laptops and
apps for smartphones or tablets
• Smart home automation compatible with Amazon
Alexa®, Google Assistant and IFTTT
• Service Dashboard features online real-time monitoring
of installed Lennox® thermostats
NOTE - See the M30 Smart W i-Fi Thermostat Product
Specifications document in the Controls section
for more information.
Remote Outdoor Temperature Sensor
Used with the M30 Smart Wi-R
Thermostat
Outdoor sensor allows thermostat to
display outdoor temperature
Thermostat
• Thermostat is not furnished with unit
• See Lennox Price Book or Lennox Pros for selection
Indoor Blower Off Delay Relay
• Delays the indoor blower -off time during the cooling
cycle
Low Ambient Kit
• Air conditioners can operate down to 45OF outdoor air
temperature without additional controls
• Allows unit to operate properly down to 30OF
NOTE - Crankcase heater and freezestat should be
installed on compressors equipped with a low
ambient kit.
NOTE -A compressor lockout thermostat should be
added to terminate compressor operation below
recommended operation conditions.
ML14KCI 11.5 to 5 Ton Air Conditioner I Page 5
FEATURES
CABINET
iO • Heavy gauge steel construction
Louvered heavy gauge steel panels surround unit on all
four sides
• Pre -painted powder paint cabinet finish
• Control box is conveniently located with all controls
factory wired
• Corner patch plate allows access to compressor
components
• Drainage holes are provided in base section for moisture
removal
Zinc -Coated Steel Unit Base
• Resists rust and corrosion
® Refrigerant Line Connections, Electrical Inlets, Service
Valves
• Sweat connection suction and liquid lines
• Located on corner of unit cabinet
• Suction valve can be fully shut off, while liquid valve
may be front seated to manage refrigerant charge while
servicing system
• Refrigerant line connections and field wiring inlets are
located in one central area of the cabinet
• See dimension drawing
Braze-Free/Press Fitting Flexibility
• Units can accommodate braze -free or press fittings for
installation versatility
Optional Accessories
Unit Stand -Off Kit
• Black high density polyethylene feet raise unit off of
mounting surface
• Four feet are furnished per order number
ML14KCI 11.5 to 5 Ton Air Conditioner I Page 6
SPECIFICATIONS
ALL REGIONS
Size
018
024
030
036
041
Nominal Tonnage
2
2.5
3
3.5
Sound Rating Number dBA
75
76
76
75
Connections Liquid line (OD) - in.
(Sweat) Suction line (OD) - in.
3/8
3/8
3/8
3/8
p4lbs.147oz.
3/4
3/4
7/8
718
Compressor Type
Sll
1Stage Scroll
1-Stage Scroll
1-Stage Scroll
1-Stage Scroll
Refrigerant (15 ft. Line Set) t R-454B charge furnished
4lbs.14oz.
5lbs.10oz.
6lbs.13oz.
7 lbs. 7 oz.
Refrigerant 30 ft. Line Set) ' R454B charge furnished
oz.
5 lbs. 7 oz.
6 lbs. 3 oz.
7 lbs. 6 oz.
8 lbs. 0 oz.
Indoor Unit Expansion Valve IXV)
26Z70
26Z70
26Z70
26Z70
26Z71
Outdoor Net face area - ft.2 Outer coil
Coil Inner coil
16.33
21.00
16.33
21.00
22.17
---
---
15.75
20.25
21.33
Tube diameter - in.
Rows
Fins - in.
5/16
5116
5/16
5/16
5/16
1
1
2
2
2
26
26
22
22
22
Outdoor HP
Fan Diameter - in.
Blades
Cfm
Rpm
Watts
118
1/8
1/8
116
1/3
22
22
22
22
26
2
3
3
3
3
2610
2990
2820
3040
3920
825
825
825
825
825
160
160
160
190
180
Shipping Data - Ibs.
155
170
180
200
225
LLtCI RICAL DATA
Line voltage data (Volts -Phase -Hz)
2 Maximum overcurrent protection (MOCP) amps
J Minimum circuit ampacity (MCA)
208/230-1-60
2081230-1-60
208/230-1-60
208/230-1-60
208/230-1-60
15
20
25
30
30
11.2
13.6
16.6
21.8
21
Compressor Rated load amps
Locked rotor amps
8.3
10.3
12.7
16.7
14.7
45
60.2
75.6
93.5
109
Fan Motor Full load amps
Locked rotor amps
0.74
0.74
0.74
1.0
2.6
1.65
1.65
1.65
1.9
- - -
yr 11UNAL t;VN 1 KULS - UKDER SEPARATELY
M30 Smart WI-Fi Thermostat 15Z69
Remote Outdoor Temperature Sensor X2658
OPTIONAL ACCESSORIES - ORDER SEPARATELY
Compressor Copeland 27V63
Factory
Crankcase Heater LG 27U16
Factory
Compressor Hard Copeland 63W22
Start Kit 1OJ42
LG 10J42
Compressor Low Ambient Cut -Off Switch 45F08
Compressor Sound Cover 1BJ42
,
Compressor Timed -Off Control 47J27
Freezestat 3/8 in. 931335
Indoor Blower Off Delay Relay 58111181
Loss of Charge Switch Kit 84M23
4 Low Ambient Kit (Fan Cycling) 34M72
Refrigerant 3/8 x 314 1 3/8 120 ft. 8SJ56
Line Sets 3/8 x 3/4 13/8 130 ft. 89J57
Liquid x Suction OD 1 3/8 x 31413/8 40 ft. 89J58
Insulation Thickness 1
Length 3/8 x 3/413/8 1 50 ft. 89J59
3/8 x 7/81318130 ft. 89J60
3/8 x 7/8 1 3/8 140 ft. 89161
,
3/8 x 7/8 1 3/8 150 ft. 89.162
Unit Stand -Off Kit 94J45
' Refrigerant charge sufficient for the line set length listed In parenthesis. For longer line set requirements see the Installation Instructions or unit Charging Label for
information about line set length and additional refrigerant charge required.
' HACR type breaker or fuse.
Refer to National or Canadian Electrical Code manual to determine wire. fuse and disconnect sae requirements.
° Crankcase Heater and Freezestat are recommended with Low Ambient Kd.
ML14KC1 11.5 to 5 Ton Air Conditioner I Page 7
SPECIFICATIONS
ALL REGIONS
Size
042
047
048
059
060
Nominal Tonnage
3.5
4
4
5
5
Sound Rating Number dBA
76
76
78
78
80
Connections Liquid line (OD) -in.
(Sweat) Suction line (OD) -in.
3/8
318
3/8
3/8
3/8
7/8
7/8
7/8
1-1/8
1-1/8
Compressor Type
1-Stage Scroll
1-Stage Scroll
1-Stage Scroll
1Stage Scroll
1-Stage Scroll
Refrigerant (15 ft. Line Set) t R-454B charge furnished
7 lbs. 2 oz.
7 lbs. 13 oz.
8 lbs. 14 oz.
9 lbs. 8 oz.
8 lbs. 14 oz.
Refrigerant (30 ft Line Set) ' R-454B charge furnished
7 Ibs. 11 oz.
8 lbs. 6 oz.
9 lbs. 7 oz.
10 lbs. 1 oz.
9 lbs. 7 oz.
Indoor Unit Expansion Valve (TXV)
26Z71
26Z71
26Z71
26Z72
26Z72
Outdoor Net face area - ft.2 Outer coil
Coil Inner coil
22.17
22.17
24.93
29.09
29.09
21.33
21.33
24.13
28.16
28.16
Tube diameter - in.
Rows
Fins - in.
5/16
5/16
5/16
5116
5/16
2
2
2
2
2
22
22
22
22
22
Outdoor HP
Fan Diameter - in.
Blades
Cfm
Rpm
Watts
1/4
1/3
114
113
1/4
26
26
22
26
26
1
4
4
4
4060
3920
3700
4050
4180
825
825
825
825
825
260
180
290
220
290
Shipping Data -Ibs.
225
225
235
260
260
ELECTRICAL DATA
Line voltage data (Volts -Phase -Hz)
2 Maximum overcurrent protection (MOCP) amps
3 Minimum circuit ampacity (MCA)
208/230-1-60
208/230-1-60
2081230-1-60
2081230-1-60
208/230-1-60
35
40
45
55
50
23.2
25.2
29.7
31.8
31.2
Compressor Rated load amps
Locked rotor amps
17.3
18.1
22.4
23.3
23.7
123
126
126
143
157
Fan Motor Full load amps
Locked rotor amps
1.56
2.6
1.7
2.6
1.56
3.2
---
3.2
---
3.2
OPTIONAL CONTROLS - ORDER SEPARATELY
M30 Smart Wi-Fi Thermostat 15Z69
Remote Outdoor Temperature Sensor X2658
OPTIONAL ACCESSORIES - ORDER SEPARATELY
Compressor Hard Copeland 10J42
Start Kit LG 10J42
LG 88M91
Compressor Low Ambient Cut -Off Switch 45F08
Compressor Sound Cover 118.1142
Compressor Timed -Off Control 47.127
Freezestat 3/8 in. 931335
Indoor Blower Off Delay Relay 581111181
Loss of Charge Switch Kit 84M23
4 Low Ambient Kit (Fan Cycling) 34111172
Refrigerant 318 x 7/8 3/8130 ft. 8SJ60
Line Sets 3/8 x 7/8 318 40 ft. 89J61
Liquid x Suction OD 318 x 718 318 50 ft. 89J62
Insulation Thickness
Length 3/8 x 1-1/8 3/8 50 ft. 731391
Unit Stand -Off Kit 94J45
rvv ¢ - r emes or operating range are plus 1 U% and mmus 5% or line voltage.
Refrigerant charge sufficient for the line set length listed in parenthesis. For longer line set requirements see the Installation Instructions or unit Charging Label for
information about line set length and additional refrigerant charge required.
2 HACR type breaker or fuse.
2 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.
4 Crankcase Heater am! Freezestat are recommended with Low Ambient Kit.
ML14KC1 11.5 to 5 Ton Air Conditioner I Page 8
DIMENSIONS - UNIT
I'1 4-118 4311
INLET J L AIR (111) (111)
v 4�8 438
(111) rlr�V/ `�. (111)
OPTIONAL UNIT
INLET I INLET STAND-OFF KIT (4) CbMPRESS�IR
\ / (Field Installed) IJ \
AIR AIR COIL DRAIN OUTLETS/-�
(Around perimeter of base)
SUCTION LINE 6-3/8 43/8
CONNECTION (162) o (111)
INLET 4 AIR \LIQUID LINE
CONNECTION 6318 4-3/8
(162) (111)
TOP VIEW TOP VIEW BASE SECTION
A
t DISCHARGE AIR
COMPRESSOR
SUCTION AN
LIQUID LINED
ELECTRICAL CONNECTION
INLETS
2314 (70) -----
�j
OPTIONAL UNIT SIDE VIEW
STANDOFF KIT (4)
(FIELD INSTALLED)
Size
A
Width and Depth
B
Height
C
inches
mm
inches
mm
Inches
mm
018
28-1/4
718
29-1/4
743
28-1/2
724
024
28-1/4
718
37-1/4
946
36-1/2
927
030
28-1/4
718
29-1/4
743
28-1/2
724
036
28-1/4
718
37-1/4
946
36-1/2
927
041
32-1/4
819
33-1/4
845
32-1/2
826
042
32-1/4
819
33-1/4
845
32-1/2
826
047
32-1/4
819
33-1/4
845
32-1/2
826
048
28-1/4
718
43-1/4
1099
42-1/2
1080
059
32-1/4
819
43-1/4
1099
42-1/2
1080
060
32-1/4
819
43-1/4
1099
42-1/2
1080
ML14KC1 11.5 to 5 Ton Air Conditioner I Page 9
EXPANDED SOUND DATA
Size
Octave Band Sound Power Levels dBA, re 10"13 Watts
Center Frequency - HZ
1 Sound
Rating
Nuntle,
' Estimated Sound Pressure Level at
Distance From Unit (dBA at distance in ft.)
125
250
500
1000
2000
4000
8000
3
5
10
15
50
018
55.5
64.5
69
67.5
65
61
56
73
66
61
55
52
41
024
61.5
64
70
69.5
66
62.5
54.5
75
68
63
57
54
43
030
60
67
72
70.5
67.5
62.5
56
76
69
64
58
55
44
036
58
67.5
72.5
71.5
66.5
62
54.5
76
69
64
58
55
44
041
63
66.5
69
69.5
66.5
61
54
75
68
63
57
54
43
D42
59.5
67.5
71.5
70
69
63.5
57.5
76
69
64
58
55
44
047
61
66
72
71
66.5
63
63.5
76
69
64
58
55
44
048
60
70,5
73.5
72.5
70.5
67
60.5
78
71
66
60
57
46
059
63
69.5
73.5
71.5
69.5
64.5
56.5
78
71
66
60
57
46
060
63.5
69.5
75
75
73
68
62.5
80
73
68
62
59
48
NOTE -the octave sound power data does not include tonal correction.
' Tested according to AHRI Standard 270-2008 test conditions,
' Estimated sound pressure level at distance based on AHRI Standard 275-2010 method for equipment located on the ground, roof, or on side of building wall with no
adjacent reflective surface within 9.8 feet. Sound pressure levels will increase based on changes to assumptions. For other applications, refer to AHRI Standard 276.
FIELD WIRING
01 SWITCHCT I I THERMOSTAT)
I-(I!y Others( I )_(Requlred) I I_
- l
LENNOX O LENNOX
AIR CONDITIONER HEATIOR
NG UNIT
AIR HANDLER
UNIT
INSTALLATION CLEARANCES
A - Two Wire Power (not furnished). See Indoor Unit Electrical Data
B -Two Wire Power (not furnished). See Electrical Data
C - Four Wire Low Voltage (not furnished). 18 ga. minimum
D - Five Wire Low Voltage (not furnished). 18 ga. minimum
All wiring must conform to NEC orCEC and local electrical codes.
NOTES:
• Service Clearance - 30 in. (762 mm) on one of the sides
adjacent to the Control Box.
• One of other three sides must be 36 in. (914 mm).
• One of the two remaining sides may be 12 in. (305 mm).
• The remaining side may be 6 in. (152 mm).
• 48 in. (1219 mm) clearance required on top of unit
• 24 in. (610 mm) required between two units
NOTES
See NOTES
NOTES
Control
See NOTES Box
ML14KC1 11.5 to 5 Ton Air Conditioner I Page 10
TXV USAGE
TXV SUBSTITUTION - R-454B
All Lennox coils and air handlers are shipped with a
factory installed TXV. In most cases, no substitution is
needed.
If a different size TXV is required, it will be listed in the
"TXV SUBSTITUTION" table by size. The correct TXV
must be ordered separately and field installed.
Size
Order Number
018
2GZ70
024
26Z70
030
036
041
26Z70
26Z70
26Z71
042
047
26Z71
26Z71
048
26Z71
059
060
26Z72
26Z72
AHRI STANDARD 210/240-2023
Standard Ratings relating to cooling or heating capacities
shall be net values, including the effects of circulating -fan
heat, but not including supplementary electric heat. Power
input used for calculating efficiency shall be the Total
Power.
Standard Ratings of units which do not have indoor air -
circulating fans furnished as part of the model, i.e., Coil -
only System, shall be established by subtracting from the
total cooling capacity 1,505 Btu/h per 1,000 SCFM, and by
adding the same amount to the heating capacity for non -
mobile -home, non -Space Constrained units. Total Power
for both heating and cooling shall be increased by 441 W
per 1,000 SCFM of indoor air circulated.
A general guide for replacing the factory installed R-454B TXV
if the indoor unit (coil/air handler) is larger or smaller than the
outdoor unit.
Outdoor Unit
Indoor Unit
Indoor
TXV
Furnished
Indoor
TXV
Replacement
Size
Tons
Size
Tons
018
1.5
42
3.5
26Z71
26Z70
018
1.5
48
4
26Z71
26Z70
018
1.5
49
4
26Z71
26Z70
018
1.5
60/60
4/5
26Z71
26Z70
018
1.5
51/61
4/5
26Z71
26Z70
018
1.5
60
5
26Z72
26Z70
024
2
42
1 3.5
26Z71
26Z70
024
2
48
4
26Z71
26Z70
024
2
49
4
26Z71
26Z70
024
2
50/60
4/5
26Z71
26Z70
024
2
51/61
4/5
26Z71
26Z70
024
2
60
5
26Z72
26Z70
030
2.5
42
3.5
26Z71
26Z70
030
2.5
48
1 4
26Z71
26Z70
030
2.5
49
4
26Z71
26Z70
030
2.5
50/60
4/5
26Z71
26Z70
030
2.5
61161
4/5
26Z71
26Z70
030
2.5
60
5
26Z72
26Z70
036
3
42
3.5
26Z71
26Z70
036
3
48
4
26Z71
26Z70
036
3
49
4
2GZ71
26Z70
036
3
50/60
4/5
26Z71
26Z70
036
3
51/61
4/5
26Z71
26Z70
036
3
60
5
26Z72
26Z70
041/042
3.5
24
2
26Z70
26Z71
041/042
3.5
30
2.5
26Z70
26Z71
041/042
3.5
30136
2.5/3
26Z70
26Z71
0411042
3.5
36
3
26Z70
26Z71
0411042
3.5
60
5
26Z72
26Z71
047/048
4
30/36
2.5/3
26Z70
26Z71
047/048
4
36
3
26Z70
26Z71
047/048
4
60
5
26Z72
26Z71
059/060
5
50/60
4/5
26Z71
26Z72
059/060
5
51/61
4/5
26Z71
26Z72
TXV Ranges:
26Z70 -1.5 to 3 ton systems - Use on 3 ton (036) and lower
systems.
26Z71 - 3.5-4 ton systems - Use on 4 ton (047/048) and down
to 3.5 ton (041/042) systems.
26Z72 - 5 ton systems - Use on 5 ton (059/060) systems only.
ML14KC1 11.5 to 5 Ton Air Conditioner I Page 11
REVISIONS
Sections
Description of Change
Specifications I Refrigerant charge updated for 30 ft. of refrigerant lines.
LENNOX .
4V*OHRM
VxEMBEB COMPANY
CE�us
�ISTE�
Intertek
Visit us at www.Lennox.com
For the latest technical information, www.LennoxPros.com
Contact us at 1-800-4-LENNOX
NOTE -Due to Lennot( ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability.
Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury.
Installation and service must be performed by a qualified installer and servicing agency. 02025 Lennox Industries, Inc.
CK40CT
Upflow I Cased I Quantum'" Coil I TXV Furnished
RESIDENTIAL
PRODUCT SPECIFICATIONS (EHB)
Q
LENNOX
QUANTUW
COIL
MODEL NUMBER IDENTIFICATION
CK40CT
Unk Type
C=Indoor Coil � � i
r r r r
� r r
: r r r
Refrigerant Compatibility: -----•
K = R-454B Compatible ;
r r r
Series
40=Qua_ Coil
i
Position/Construction ---
C = UpOow/Cased I
Metering Device ---�
T = Factory installed Check/Expansion Valve
for R-410A refrigerant(non-bleed ort
INDOOR COILS
LENNOX
1.5 to 5 Tons
-36A-01
' •-------
Revision Leval
i
01 - R-410A TXV installed
i
----------' Cabinet width
A = 14-1 /2
B=17-1/2
i
C=21 in.
i
D=24-1/2 illj
L ---- A Nominal Coolin Ca
9 PICKY
18/24 =1.5/2 tons
24 = 2 tons
30 = 2.5 tons
30/36 = 2.5/3 tons
36 = 3 tons
48 = 3.5/4 tons
49 = 4 tons
50/60 = 4/5 tons
Furnaces with the same letter designation physically match the indoor coil.
Form Number 211071 1 May 2024
Supersedes all previous versions
CONTENTS
Air Resistance........................................................
6
Approvals And Warranty ..................................................
2
Contents...........................................................2
Dimensions.........................................................7
Features...........................................................2
Model Number Identification................................................1
Optional R-454B TXV Substitution ... ......... . . ..........
.................... 5
R-454B Refrigerant Conversion - Order Separately ... ..........
.. .... ..... ........... 5
Specifications ... .....................................
....4
APPROVALS AND WARRANTY
APPROVALS
• Tested with matching air conditioners and heat pump units in the Lennox Research Laboratory environmental test room in
accordance with AHRI Standard 210/240-2023
• AHRI Certified system match -ups and expanded ratings, visit www.LennoxPros.com
• Air resistance tests from Lennox Laboratory air test chamber
NOTE - Coils can be field configured for use with R-454B refrigerant during the initial installation only. Coils may not be
modified after initial installation.
WARRANTY
• All other covered components:
• Limited five years in residential installations
• Limited one year in non-residential installations
NOTE - Refer to Lennox® Basic Limited Warranty at www.Lennox com for additional details.
FEATURES
APPLICATIONS
• 1.5 to 5 ton nominal sizes
• Lennox designed upflow cased indoor coils can easily be
installed with most Lennox upflow furnaces
• Factory installed R-410A check/expansion valve
NOTE - Coils can be field converted for use with R-454B
refrigerant.
COIL CONSTRUCTION
Quantum- Coil
• Lennox designed and fabricated coil
• Aluminum tubing, hairpins, distributor and header tubes
• Copper refrigerant sweat connections on both liquid and
suction lines for easy brazing
• Ripple -edged aluminum fins
• Lanced fins provide maximum exposure of fin surface to
air stream
• Helical grooved tubing provides superior heat transfer
• Twin coil construction assembled in an A" configuration
for large surface area
• High pressure testing insures leak -proof construction
Refrigerant Line Connections
• Copper refrigerant sweat connections on both liquid and
suction lines for easy brazing
• Lines extend outside of the cabinet for ease of
connection
• See dimension drawings for locations
Anti -Microbial Drain Pan
Non corrosive, UV -resistant polymer drain pan with dual
FPT drain connections
Anti -Microbial additive resists growth of mold and
mildew on drain pan which improves indoor air quality
and reduces drain line blockage
R-410A Check and Expansion Valve
• For use with R-410A systems
• Wide range valve with Chatleff style fitting
• Factory installed on all models
CK40CT-01 11.5 to 5 Ton Indoor Coils I Page 2
FEATURES
R-454B REFRIGERANT CONVERSION
Additional Components are required for conversion to
R-454B Refrigerant:
• Refrigerant Detection System (RDS) Coil Sensor Kit
• Refrigerant Detection System (RDS) Blower Control
Board
R-454B Check and Expansion Valve
Optional Accessories
Refrigerant Detection System (RDS) Coil Sensor Kit
Complies with UL 60335-2 40 approved standard
Required for all systems using R-454B refrigerant
Consists of Refrigerant Detection System (RDS) sensor,
lineset sleeves, mounting brackets and A21L labeling
Sensor ensures safe operation for systems equipped
with R-454B refrigerant
Indoor sensor will detect any R-454B refrigerant
See R-454B Refrigerant Conversion Table on page 5
Refrigerant Detection System (RDS) Blower Control Board
Communicating Blower Control Board (Universal)
• Communicating Blower Control Board and Sensor can
be used universally with any Lennox® communicating
furnace or any non -communicating 24 volt furnace
Non -Communicating Blower Control Board
• Non -Communicating Blower Control Board and Sensor
can be used with any non -communicating 24 volt
furnace
Standard Features
• Complies with UL 60335-2-40 approved standard
• Required for all systems using R-454B refrigerant
• Connects to the RDS sensor furnished with the RDS
Coil Sensor Kit
• Supports up to two RDS Sensors (factory setting)
• Used as interface between indoor unit and thermostat
to control system
• Ensures safe operation for systems equipped with
R-454B refrigerant
• If R-454B refrigerant is detected the refrigerant
detection system will prevent compressor and heating
operation until R-454B refrigerant is no longer detected
• Refrigeration detection system also energizes the
blower if R-454B refrigerant is detected to mitigate
any concentrations of refrigerant from the conditioned
space
• Multi -color LED for system status and as an aid in
troubleshooting
• Flashing LED codes for system status (Green/Blue)
and diagnosing Sensor errors (Red)
• Alarm relay can trigger an external alarm if R-454B
refrigerant is detected
• Zone relay opens all zone dampers (if part of a zoning
system) if R-454B refrigerant is detected
• Power is disabled to non -communicating thermostats
to prevent demand if R-454B refrigerant is detected
• On system start-up blower will run for five minutes and
any thermostat demands are disabled
• Dimensions (H x W x D): 7-7/16 x 7-7/16 x 2-1/2 (189 x
189 x 127 mm)
• See R-4548 Refrigerant Conversion Table on page 5
NOTE - Refer to the Installation Instructions for additional
information.
R-454B Check and Expansion Valve
• For use with R-454B systems
• Wide range valve with Chatleff style fitting
• Replaces factory installed TXV, internal to cabinet
• See Optional R-454B TXV Substitution table on page 5
CABINET
• Pre -painted heavy gauge steel
• Insulated with thick fiberglass insulation
• Flanges provided in outlet for ease of duct connection
• Coil slides out of cabinet for ease of servicing
• Removable panels provide access to coil
• Refrigerant lines extend outside of cabinet for easy
installation
Furnace Match -Up
• Coils exactly match corresponding furnaces with the
same letter designation in model number
No adaptor required
• Engaging holes furnished on cabinet for alignment with
furnace
CK40CT-01 11.5 to 5 Ton Indoor Coils I Page 3
SPECIFICATIONS
1.5TO2TON
Size
18/24A
18/24B
24A
24B
Nominal Tonnage
1.512
1.5 / 2
2
2
Furnace Cabinet Matching Letter Width
A
B
A
B
Coil & Furnace Cabinet Width - in.
14-1/2
17-1/2
14-1/2
17-1/2
Connections Liquid line (OD) sweat - in.
Suction line (OD) sweat - in.
Condensate drain (FPT) - in.
3/8
3/8
3/8
3/8
3/4
3/4
3/4
3/4
(2)3/4
(2)3/4
(2)3/4
2 314
Indoor Net face area -ft'
Coil Tube diameter- in.
Rows
Fins -in.
Shipping Data -Ibs.
3.11
3.11
3.55
3.55
3/8
3/8
3/8
3/8
2
2
3
3
18
1 18
14
14
30
1 34
38
1 43
SPECIFICATIONS
2.5TO3TON
Size
30A
30B
30/36A
30136E
30136C
Nominal Tonnage
2.5
2.5
2.5/3
2.5/3
2.5/3
Furnace Cabinet Matching Letter Width
A
B
A
B
C
Coil & Furnace Cabinet Width - in.
14-1/2
17-1/2
14-1/2
17-1/2
21
Connections Liquid line (OD) sweat- in.
Suction line (OD) sweat - in.
Condensate drain (FPT) - in.
3/8
3/8
3/8
3/8
3/8
3/4
3/4
3/4
3/4
3/4
(2)3/4
(2)3/4
(2)3/4
(2)3/4
(2)3/4
Indoor Net face area - ft.2
Coil Tube diameter - in.
Rows
Fins per inch
4.44
4.44
4.89
4.89
4.89
3/8
3/8
3/8
3/8
3/8
3
3
2
2
2
1 13
13
18
18
18
Shipping Data -Ibs.
1 45
50
41
45
48
SPECIFICATIONS
3TO4TON
Size
36A
36B
48B
48C
49C
Nominal Tonnage
3
3
4
4
4
Furnace Cabinet Matching Letter Width
A
B
B
C
C
Coil & Furnace Cabinet Width - In.
14-1/2
17-1/2
17-1/2
21
21
Connections Liquid line (OD) sweat - in.
Suction line (OD) sweat - in.
Condensate drain (FPT) - in.
3/8
3/8
3/8
3/8
3/8
314
3/4
7/8
7/8
7/8
2) 3/4
(2)3/4
(2)3/4
(2)3/4
(2)3/4
Indoor Net face area - ft.'
Coil Tube diameter- in.
Rows
Fins per inch
4.89
4.89
5.77
5.77
7.0
3/8
3/8
318
3/8
3/8
3
3
3
3
3
14
14
13
13
15
Shipping Data -Ibs.
46
50
55
60
70
SPECIFICATIONS
4 TO 5 TON
Size
50/60C
60C
60D
Nominal Tonnage
415
5
5
Furnace Cabinet Matching Letter Width
C
C
D
Coil & Furnace Cabinet Width - in.
21
21
24-1/2
Connections Liquid line (OD) sweat - in.
Suction line (OD) sweat - in.
Condensate drain (FPT) - in.
3/8
3/8
3/8
7/8
7/8
7/8
(2)3/4
(2)3/4
(2)3/4
Indoor Net face area - ft.2
Coil Tube diameter - in.
Rows
Fins per inch
5.78
7.50
7.58
3/8
3/8
3/8
3
3
3
1 12
16
14
Shippin Data-Ibs.
1 60
73
72
CK40CT-01 11.5 to 5 Ton Indoor Coils I Page 4
R-454B REFRIGERANT CONVERSION - ORDER SEPARATELY
Order No.
Refrigerant Detection System (RDS) Coil Sensor Kit 26Z69
Refrigerant Detection System (RDS) Any Lenno)& Communicating Furnace 4L 27AO3
Blower Control Board any Non -Communicating 24V Furnace (Universal)
Any Non -Communicating 24V Furnace 27AO2
NOTE - Communicating Blower Control Board and Sensor can be used universally with Lennon° communicating furnace or any noncommunicating 24 volt furnace
Non -Communicating Blower Control Board and Sensor can be used with any non -communicating 24 volt furnace.
NOTE - Order R454B Expansion Valve separately.
OPTIONAL R-454B TXV SUBSTITUTION
NOTE - Additional components are required for R-454B
Conversion. See Optional Accessories table.
Size
Order Number
18/24
24
26Z70
2SZ70 - - -
30
26Z70
30/36
36
48
26Z70
26Z70
26Z71
49
2GZ71
50/60
2SZ71
60
2SZ72
CK40CT-01 11.5 to 5 Ton Indoor Coils I Page 5
AIR RESISTANCE
Size
Air
Volume
Total Resistance
DryCoil
Wet Coil
cfm
in. w.g.
in. w.g.
18124A
181246
400
0.06
0.08
600
0.11
0.17
800
0.18
0.25
1000
0.27
0.39
1200
0.37
0.52
24A
400
0.05
0.05
600
0.09
0.10
800
0.16
0.18
1000
0.23
0.26
1200
0.32
0.36
24B
400
0.03
0.04
600
0.07
0.09
800
0.11
0.15
1000
0.17
0.22
1200
0.23
0.31
30A
_
600
0.07
0.08
800
0.12
0.13
1000
0.18
0.20
1200
0.26
0.28
1400
0.34
0.37
30B
600
0.06
0.06
800
0.09
0.11
1000
0.13
0.16
1200
0.19
0.23
1400
0.25
0.31
30/36A
30136B
30/
36B
800
0.13
0.14
1000
0.19
0.21
1200
0.27
0.30
1400
0.34
0.39
1600
0.45
0.51
800
0.08
0.11
1000
0.13
0.16
1200
0.17
0.21
1400
0.22
0.28
1600
0.29
0.34
Size
Air
Volume
Total Resistance
DryCoil
Wet Coil
cfm
in. w.g.
In. w.g.
36A
800
0.13
0.14
1000
0.19
0.21
1200
0.27
0.30
1400
0.34
0.39
1600
0.45
0.51
48B
1000
0.13
0.13
1200
0.18
0.18
1400
0.23
0.24
1600
0.30
0.31
1800
0.37
0.40
48C
1000
0.07
0.09
1200
0.10
0.12
1400
0.13
0.16
1600
0.16
0.20
1800
0.20
0.24
49C
1200
0.08
0.12
1400
0.13
0.17
1600
0.17
0.22
1800
0.22
0.28
2000
0.28
0.35
50/60C
1200
0.13
0.17
1400
0.18
0.23
1600
0.23
0.29
1800
0.28
0.37
2000
0.34
0.43
60D
1400
0.11
0.15
1600
0.14
0.18
1800
0.17
0.21
2000
0.21
0.27
2200
0.25
0.32
2400
0.30
0.37
60C
1400
0.15
0.19
1600
0.19
0.23
1800
0.24
0.28
2000
0.29
0.34
2200
0.33
0.40
2400
0.39
0.46
CK40CT-01 11.5 to 5 Ton Indoor Coils I Page 6
DIMENSIONS
CK40CT CASED
CK40CT-18/24(A/B),-30/36(AIBIC) and-36(A/B) Coils
SUCTION
LINE
RIDS COIL
SENSOR
WIRING INLET
(Left Side) \ 17/1
LIQUIDLINE1/2
ET 2.8
NING (67)
9/16D
(14) FRONT VIEW
I:I
314 (19)
3/4 19.1/2 _ 314
(19) (495) (19)
C
OUTLET
OPENING
3/4 (19)
TOP VIEW
314 21 (533)
(19)
B AIR
I FLOW
F
1�1-1/4
(32)
CONDENSATE INLE7
DRAINS OPENING
20-7/16 9116
9/16
(14) (519) (94)
SIDE VIEW
Size
A
B
C
D
E
F
G
H
in.
mm
in.
mm
in.
mm
in.
mm
in.
mm
in.
mm
in.
mm
in.
mm
18/24A
14-1/2
368
16-1/2
419
13
330
13-3/8
340
7-1/4
185
3-5/8
92
2-5/8
66
2-3/8
60
18/24B
17-1/2
445
16-1/2
419
16
406
16-3/8
416
7-1/4
185
3-5/8
92
2-5/8
66
2-3/8
60
30136A
14-1/2
368
24-1/2
622
13
330
13-3/8
340
13-1/2
343
3-5/8
92
2-5/8
66
2-3/8
60
30136B
17-1/2
445
24-1/2
622
16
406
16-3/8
416
13-1/2
343
3-5/8
92
2-5/8
66
2-3/8
60
30136C
21
533
24-1/2
622
19-1/2
495
19-7/8
505
13-1/2
343
35/8
92
2-5/8
66
1 2-3/8
160
36A
14-1/2
368
24-1/2
622
13
330
13-3/8
340
13-1/2
343
3-5/8
92
2-5/8
66
2-3/8
60
366
17-1/2
445
24-1/2
622
16
406
16-3/8
416
13-1/2
343
3-5/8
92
2-5/8
66
2-3/8
1 60
CK40CT-01 11.5 to 5 Ton Indoor Coils I Page 7
DIMENSIONS
CK40CT CASED
CK40CT-24(A/B),-30(A/B),-48(B/C),-50/60C and -60D Coils
(NOTE - See next f CK40CT 49C 6F d CK40CT 60C 6F C^n�N
page or - an
314
(19)
NOTE- CK40CTS0D coil is positioned in cabinet
with coil face running left to right,
all other coil sizes are positioned like drawing.
A I 3/4
(19)
SUCTION
LINE / 1
RDS COIL
SENSOR
WIRING INLET
(Left Side)
LIQUID r /
LINE C-----
1-1/2
(38)
LD
ET 2-5/8
NING (67)
9116
(14) FRONT VIEW
H
F
3/4 (19)
19-1/2
(495)
C
OUTLET
OPENING
3/4 (19)
TOP VIEW
3/4
(19)
�1-1/4
(32)
CONDENSATE INLET
DRAINS OPENING
9/16 20-7/16 9/16
(14) L(519)L (74)
SIDE VIEW
Size
A
B
C
D
E
F
G
H
in.
mm
in.
mm
In.
mm
in.
mm
in.
mm
in.
mm
in.
mmi
in.
Imm
24A
14-1/2
368
18-1/2
470
13
1330
13-3/8
340
9-3/4
248
3-5/8
92
2-5/8
66
2-3/8
60
24B
17-1/2
445
18-1/2
470
16
406
16-3/8
416
9-3/4
248
3-5/8
92
2-5/8
66
2-3/8
60
-30A
14-1/2
368
22-1/2
572
13
330
13-3/8
340
11-1/2
292
35/8
92
2-5/8
66
2-3/8
60
30B
17-1/2
445
22-1/2
572
16
406
16-3/8
416
11-1/2
292
3-5/8
92
2-5/8
66
2-3/8
60
48B
17-112
445
27-1/2
699
16
406
16-3/8
1416
12-1/2
13181
3-5/8
92
2-5/8
66
2-3/8
60
48C
21
533
27-1/2
699
19-1/2
495
19-7/8
505
12-1/2
318
3-5/8
92
2-5/8
66
2-3/8
60
50/60C
21
533
27-1/2
699
19-1/2
495
19-7/8
505
12-1/2
318
3-518
92
2-5/8
66
2-3/8
60
60D
24-1/2
622
29-1/2
749
23
584
23-3/8
1 594
10
254
3-5/8 1
92
2-5/8
66
2-3/8
60
CK40CT-01 11.5 to 5 Ton Indoor Coils I Page 8
DIMENSIONS
CK40CT-49C-6F and CK40-CT-60C-6F
21
(533)�
SUCTION
LINE
I /
RDS COIL /
SENSOR
WIRING INLET
(Left Side) \
LIQUID C r
LINE C —
1-1/2�
(38)
IN2-5/8
OPENING (67)
9/16 19-7/8
(14) (505)
FRONT VIEW
0
L
13/4
(44)
CK40CT CASED
3/4 (19)
19-1/2 314
(495) (19)
2
OUTLET
OPENING
3/4 (19)
TOP VIEW
22
3/4 (559)
(19)
A
L1.1/4
(32)
CONDENSATEL INLET
DRAINS OPENING
9/16 21.7/16 9l16
(14) (545) L (74)
SIDE VIEW
Size
A
B
C
D
E
in.
mm
in.
mm
in.
mm
in.
I mm
I in.
mm
49C
10
254
3-5/8
92
29-1/2
749
2-3/8
60
2-5/8
66
60C
14-1/2
368
35/8
92
31-1/21
800
1 2-3/8
1 60 1
25/8 1
66
CK40CT-01 11.5 to 5 Ton Indoor Coils I Page 9
--7)
LENNOX .
Intertek
Visit us at rww Lennox com
For the latest technical information, www-LennoxPros Com
Contact us at 1-800-4-LENNOX
NOTE -Due to Lennox ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability.
Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury.
Installation and service must be performed by a qualified installer and servicing agency. 02024 Lennox Industries, Inc.
�V Vu Lnci ZIV1 a16wu 11 yVuflay HA U liana Ud MC ft.
em
inox ML14KC AC 3.5 Ton
EQUIPMENT Quantity: 2
Category: Condenser
Lennox, Merit, 3.5 Ton. Air Conditioner
ML14KC1-042- Catalog # 25C93
-Efficiency rating meets or exceeds energy efficiencies of.14.30. SEER2. -ENERGY START) Certified -meets or exceeds federal
guidelines for energy -efficient performance.- Federal Tax Credit Eligible -this product is eligible for the Energy Efficient Home...
Category: Evaporator Coil
Lennox, Cased Upflow, 4 Ton, Evap Coil
CK40CT-48C - Cat # : 25 u 82
CK40CT. -01 Indoor Evaporator Coil. Up-flow,full-cased R-410A models, convertible to R-454B at time of initial installation. For
every application and configuration, our cooling coils are the perfect choice. Introducing. CK40CT. -01 up -flow evaporator coils by...
ACCESSORIES Quantity: 3
Category: HVAC Add-Ons
Locking Refrigerant caps
CUSTOM-26YYUX / Quantity:l
- Secure Seal: These 1/4 inch locking caps provide a secure, airtight seal for HVAC systems and refrigerant lines. -
Durable Construction: Crafted from high -quality materials, these caps are designed for long-lasting perfgrmance. - Eas...
Category: HVAC Add-Ons
Re -pipe PVC Condensate drain line
CUSTOM-3G8M19 / Quantity: 1
Re -pipe Condensate drain line from unit to drain.
Category: HVAC Add-Ons
Liquid tight A/C Whip
CUSTOM-AQKL06 /Quantity: 1
Liquid -tight flexible conduit system. A labor saving convenience kit for A/C unit hookup. Also used for heat pumps,
refrigeration, hot tubs, swimming pools and outdoor lighting. Three distinctwire colors for ease of hook-up.1 straight...
WHAT YOU'LL GET Quantity: 6
Arctic Mechanical Guarantee on Workmanship & 24/7 Service Department: We offer a One -Year Parts and One -Year Labor
Warranty on all our HVAC services and installations. This guarantee ensures that any issues related to the quality of workmanship
or materials used are addressed at no additional cost within the first year. Additionally, you will be backed by Arctic Mechanical's
24/7 Service Department, ensuring that assistance is available whenever you need it, givingyou peace of mind and confidence in the
durability and reliability of our work.
Complete System Startup: A thorough initialization of the HVAC system, ensuring all components operate correctly according to
the manufacturer's soecifications. This includes testine the heating. cooline, and ventilation functions for optimal oerformance and
�f HVAC Permit Application Village of Rye Brook
938 King St Rye Brook, NY 10573
Phone: (914)939-0668 1 www.ryebrook.gov
Building Department
Project Information
Scope of Work:
Replacement
# of Units: List Equipment: Location of Equipment: Method of Installation/Removal:
1 Condenser & Coil Outside Remove & Replace
(list all eauipment needed to perform iob)
HVAC Permit Application, page 1 / 1