Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BP25-070
PERMIT # j6PcD DATE: SECTION . 73 BLOCK LOT 34P TYPE OF WORK✓li�7.S'�� : 1 S/7zi/1)1O So�Q/ c;ole%S�O �P �ocJ`Ious� JOB LOCATION 33 �t l 9 Q /0'77'�C i �c l2, OWNER !�D�1 CI /Q�Y"C�/y1 CONTRACTORSu/! IL/2 EST. COST —moo o ,/ CO # (a (1, Lf ' `t p TCO # FOOTING FOUNDATION FRAMING RGH FRAMING INSULATION ;�l_UM131NG E3 RGH PLUMBING iAAS SPRINKLER ELECTRIC LOW -VOLT O ALARM O AS BUILT C� FINAL I� Egg ► �: W♦ WA r2 I I aEE DATE INSPECTION RECORD DATE I NSP %374,67� ��!) -/ ool OTHER APPROVALS OTHER y t l� V O\ 19 VILLAGE OF RYE BROOK MAYOR 938 King Street, Rye Brook,N.Y. 10573 ADMINISTRATOR Jason A.Klein (914) 939-0668 Christopher J. Bradbury www.tyebrookny.gov TRUSTEES BUILDING& FIRE INSPECTOR Susan R. Epstein Steven E. Fews David M.Heiser Donald T.Krom,Jr. Salvatore W.Morlino CERTIFICATE OF COMPLIANCE August 11,2025 Donald Krom Jr&Marguerite Krom 33 High Point Circle Rye Brook,New York 10573 Re: Re: 33 High Point Circle, Rye Brook,New York 10573 Parcel ID#: 124.73-1-36 Building Permit#25-070 issued on 4/16/2025 to Re-Install Rooftop Solar Array This certifies that the rooftop solar array,installed under the above captioned permit has been satisfactorily completed. Sincerely, Steven E. Fews Building&Fire Inspector /to For office use only: BUILD i�; P' ENT Dil t � PERMIT# -07D JUL 2 1 2025 VIL1A OF RYE '46OK [sSUF,D:938 KING STRE E BROOK, VV PORK 10573 DATE: -7 VILLAG E OF RYE BROOKS � FEE;$r j'�=PAID 104 BUILDING DEPART NIENT w ti. ov APPLICATION FOR CERTIFICATE OF OCCUPANCY, CERTIFICATE OF COMPLIANCE, AND CERTIFICATION OF FINAL COSTS TO BE SUBMITTED ONLY UPON COMPLETION OF ALL WORK, AND PRIOR TO THE FINAL INSPECTION rtssstrttsrtsts**t*ss***ssssrtsts**st*sssss*ss*rtsss**stsssrtrts*s**rttttsssrtssrtssss*s*ssrts*sit*s**ss*sssssss*sss**s*t*ssssssssss*sss Address: 33 High Point Circle, Rye Brook, NY one family residentiaPl 124.73 - 1 - 36 Occupancy/Use: arceI ID#: Zone: _ Owner: Donald Krom Jr& Marguerite Krom Address: _ 33 High Point Circle, Rye Brook, NY P.E./R.A. or Contractor: River LLC dba SunBlue EnergyAddress: 147 Valley St, Sleepy Hollow, NY 10591 Christopher Hale, President, SunBlue Person in responsible charge: X33rrpg s. 147 Valley St, Sleepy Hollow, NY 10591 Application is hereby made and submitted to the Building Inspector of the Village of Rye Brook for the issuance of a Certificate of Occupancy/Certificate of Compliance for the structure/construction/alteration herein mentioned in accordance with law: STATE OF NEW YORK, COUNTY OF WESTCHESTER as: Christopher Hale, President, SunBlue.En CC 49 Academy St being cul?�wom,deposes and says that he/she resides at Y (Print Name of Applicant) i No.and Street) in Pleasantville in the County of Westchester in the State of NY that (City/Town/Village) he/she has supervised the work at the location indicated above,and that the actual total cost of the work,including all site improvements, labor,materials,scaffolding,fixed equipment,professional fees,and including the monetary value of any materials and labor which may have been donated gratis was:S 10,500.00 for the construction or alteration of. uninstallation and reinstallation of existing solar energy system on roof of residence. Deponent further states that he/she has examined the approved plans of the structure/work herein referred to for which a Certificate of Occupancy/Compliance is sought,and that to the best of his/her knowledge and belief,the structure/work has been erected/completed in accordance with the approved plans and any amendments thereto except in so far as variations therefore have been legally authorized,and as erected/completed complies with the laws governing building construction.Deponent further understands that it shall be unlawful for an owner to use or permit the use of any building or premises or part thereof hereafter created,erected,changed,converted or enlarged,wholly or partly,in its use or structure until a Certificate of Occupancy or Certificate of Compliance shall have been duly issued by the Building Inspector as per§250-10.A. of the Code of the Village of Rye Brook. Sworn to before me this 1 144t, Sworn to before me this / day of �(�� , 20.1(� day of JIA GA , 20 ZS J 7a Signature of Property Owner nature of A licant Donald Krom, .Tr, Christopher Hale, President, SunBlue Energy t Name of Property Owner Print Name of Applicant lj�ktkl�41_ ���� C Aban�;Zz' Notary Public Notary Public Marla L. lensky Marla L.Teplensky Notary Public,State of New York Notary public,State of New York Reg.No.01TE6364189 Reg.No.01TE6364189 Qualified in Westchester County - Qualified in Westchester County Commission Expires September 5,2025 Commission Expires September 5.2025 O y m ` O BUILDING DEPARTMENT ❑1ju[xa)xNh INxP)tcxl►R dAssxsxANT BITIU)MG INSPEGrOR ViLL,A.GE OF RYE BROOK ❑CODE 1+NVOYACT. 11,M 0P1+[Cltlt 138 King Street•Ryc Brook,NY 1.0573 (914)939-lK68 FAx.(914)939-5801 ww_w.,._a�c�l�roo.k.or�► .- - - - - ._ - - - - - - - ._ - - - INSPECTION REPORT - - - - - - - - - - - - - - - - - - - - ADDREss:-.33 __ 1 --_�� 41�•.t G►��C ' 7- O_ . �__ -._._...__ .._�_...__....._._.._. DATE• Z l� PERMI: #_ ��-Z_S____-0 7 O ISSUED: �/•1�i` __7. SECT:JZU BLOCK: / LOT: 3G LOCATION: ---- -^_ - ,Rw T ._ OCCUPANCY: �— ❑ Violation Notcd IWE WORK IS... epASSED ❑ FAILED /REINSPECTION ❑ SITE INSPECTION REQUIRED ❑ FOOTING ❑ FOOTING DRAINAGE ❑ FouNIM ION ❑ UNDERGROT.T. l►PI.UMItIN(: NOT]?S ON INSPECTION: ❑ ROUGH PLUMBING ❑ ROUGH FRAMING; ❑ I.NSULA!"ON ❑ L.P.Gas r 1 a- ❑ _ 1___._��U� .�Q�l, re ❑ Fuu,SI-RINKI.F{IR. ❑ FINAI,PLUMICINc; — - ❑ CROSS CONNEC".1.'ION ---. _ —-_-� ---j2rF1NA_L OTHER -- _ C n N w s � \N k o + a a s 10, W uitc H W o v v A. ~ ■ o C/) �p C pd r04 n Ln o �` F�1 �" \ `D a o 3 o w V] P� ■ O il C w a O w w Q C 'd ° y w C p • p or 1w `„ � o p aZ wo � W � hhh�y��lll © �, �j � � C� � � _ N c�a R, v •� o � � -- N N A w V 0o ' 00 a s W OQ h+ai �i N eq Q v ` aui (>o 1� n tr� O� zUzv .� � � C z • ►--� z �+ ,,,� w w o q � W , 00 a x ■ � � V W rW n u CA tP O O w � ■ Z V a o xz Coi � w 5 r 'W7 cz�, cCd —V I—) z �JW �1 F. O v�i a Ei O O Ey z z a CZo W u z w C7 A z © G � � acu A W z p4 4 'u o .n BUILDING DEPARTMENT L' �W F� VILLAGE OF RYE BROOK 938 KING STREET RYE BROOK,NY 10573 MFEB 2 rJ 2025 -DJ (914)939-0668 _ www.nebrooknv.gov VILLAGE OF RYE BROOK BUILDING DEPARTNI)ENT FOR OFFICE USE ONLY: Aµpruvat Date: �� App ' ation# Approval Signature: ARCHI CTURAL REVIEW BOARD: Disapproved: Date: BOT Approval Date: Case# Chairman: PB Approval Date: Case# : Secretary: ZBA Approval Date: Case# Other: Application Fee> CEO Permit Fees: APPLICATION TO INSTALL PHOTOVOLTAIC SOLAR ARRAY Application dated: is hereby made to the Building Inspectorofthe Village of Rye Brook,NY,for the issuance ofa Permit for the installation ofa Photovoltaic Solar Array as per detailed statement described helo%%. I. Job Address: 7J�J CIA 9_' e (Dook SBL: 1 (o Zone:,_ 2 Type,kW&Location of Array,(use additional sheets 3fnecessary): i'QJ�S i S 2 S 1 L� :3WW MvLeA 5 _} 31 aiao0 C kU 5 W(V 3. Property Owner: 10VIaU YCOM Address: 33 Pon,d- N'o- Phone#�q 1 -�3'I- L4 b1�o Cell# NA e-mail d k_'r0'0A jf C,(Wa1� a. Applicant: Q 1' z4yt'( U-C 81.0, n6t Address: 141 Phone# ell# NA e-mail 5. Design Engineer: 5A b Pi5 Address: `L(a 4c" 4�14 U i 1' i e-d,G? Phone# 2A� -ty 'S�p0 I Cell# MA e-mail {{ I I L �'lnoo. vvl b. Solar Contractor: _k2 Air- Xt Address: — Phone# Cell# e-mail 7. Occupancy;(1-Fam,2-Fam..Commercial,etc )Pre-conStruction: I-@AtA Post-construction: 14�wt 8. If building is located on a corner lot,which street does it front on: A 9. N.Y.State Construction Classification: J N.Y.State Use Classification: 10. Construction Type&Location:( )Typical Western Lumber Frame;( )Timber Frame[TC];( )Wood Truss[TT]; ( )Pre-engineered wood[PW];Located;( )Floor Framing[F];( )Roof Framing[R);()Floor& Roof Framing[FR];Other: NA I I. Number of stories: R Roof Style:(hip,shed,mansard,etc_ ) N 12. Will a New Roof Be Installed: No © Yes ® (a separate roofing permit is required to re-roof an existing building) 13. Roofing Material&Number of Layers: vF I 61 H2024 14. Will the proposed project disturb 400 sq.ft.or more of land,or create 400 sq.ft.or more of impervious coverage requiring a Stormwater Management Control Permit as per§217 of Village Code? No: N Yes: ❑ Area: 15. Will the proposed project require a Site Plan Review by the Village Planning Board as per§209 of Village Code? No:U Yes: ❑ (If yes,applicant must submit a Site Plan Application,&provide detailed drawings) 16. Will the proposed project require a Tree Removal Permit as per§235 of Village Code?No: 0 Yes: El (If yes,applicant must submit a Tree Removal Permit Application) 17. Does the proposed project involve a Home-Occupation as per §250-38 of Village Code? No: ® Yes: ❑ Indicate:TIER 1: TIER 11: TIER III:_ (if yes,a Home Occupation Permit Application is required) 18. What is the total estimated cost of construction: $ �0.500, (Note:The estimated cost shall include all site improvements,labor,material,scaffolding,fixed equipment,professional fees,including any material and labor which may be donated gratis.If the final cost exceeds the estimated cost,an additional fee will be required prior to issuance of the C/O). 19. Start Date: Completion Date: Ate, Za25� This application must bear the notarized signature(s) of the legal owner(s) of the subject property, and the applicant of record in the spaces provided.Any application not properly completed in its entirety and/or not properly signed shall be deemed null and void and will be returned to the applicant. Please note that application fees are non-refundable. STATE OF NEW YORK,COUNTY OF WESTCRESTER ) as: I,dlrig,t, ( �k i 'Lllbetn y sworn,deposes and states that he/she is the applicant above named, (print hame of individuai signing as the applicant) and further states that(s)he is the legal owner of the property to which this application pertains,or that(s)he is the, ce yo'CAC3y for the legal owner and is duly authorized to make and file this application. (indicate architect,contractor,agent,attorney,etc.) That all statements contained herein are true to the best of his/her knowledge and belief,and that any work performed,or use conducted at the above captioned property will be in conformance with the details as set forth and contained in this application and in any accompanying approved plans and specifications,as well as in accordance with the New York State Uniform Fire Prevention& Building Code,the Code of the Village of Rye Brook and all other applicable laws,ordinances and regulations. Sworn to before me this 1344A Sworn to before me this 19 4,� day of 20 `�' day of 20 2 5 Notary Public Notary Public Signature of Property Owner Sighmure7ofXplilicant Print Name of Property Owner Print Name o Applicant ` ,1 - 6/1/2024 = s = s 0 � Lin N �+ Ln O O en cc _ qT qT w L W 0 0.4 a W C y _ 'G ~� a. =� W oc 0-4 W W W M W Ul OF; oo V) p z x r v c W Z f M0*0rn CN a , ONO Ln • � OG OG � w O V: .. W z r o C H ►� (Al ,. w � U E-i A Q J � Q W oe � • _ DD BUILDING 0—Ei"AATMENT FEB 12 2025 VILLAGE OF RYEbROOK 938 KING Sax-r RYE B ,NY 10573 VILLAGE OF RYE BROOK BUILDING DEPARTMENT ww1v. `- tiokn . ELECTRICAL PH RNIi r APPUCATIOti Westchester Count) Master Electricians License Required FOR OFFICE l'SE ON1 1 BP F-P Approval Date: Permit Fee:S Approval Signature: Other. •••.••••sssssss••s•••s+••s•srssssssssssss•sass•s•ss••••ssssssss••sss•ss•sassss•,.••ssss•sssessasss UO NOT STATT 1''ORK or CONSTRLCTION UNTIL A PERMIT IL1S BFF.N ISSUED B1 Till, WII DING INSPECTOR. THE ADMINISI R kTIVF FFE FOR WORK PROGRESSED OR ('()NJ1'L.FTED WITHOUT A Pf It'III I is 12%OF"rHF. TOTAL COST OF CONSTRUCTION Wl I It .1 Nt FEE Of S'�;u.utl Application dated, 111J is hereby made to the Building Inspector of the Village of Rye Brook NY, for the issuance of a Permit to install andror remove electrical equipment,wirng, fixtures,or to perform other high or low voltage electrical work as per the detailed sutement described below. By signing this document, the applicant & property owner agree that all electrical work performed will be in conformance with all applicable Federal,State,County and Local Curies.. 1.Address: 2 3 �, PA- C t r Lie F3h�v�L SBL: 1,7�)T i 73 —/-3 Zone: u6 2.Property Owner AGfy�� �10.rc, U� t K Address. 3 3 -(AlG t� ?Q t r (2f �cr e �k Ad Phone K:. ���" / 3 Z Y�07� `el!q: email: 3.Master Electncian./Licenscd Installer. �I�rf tlti S. 5 ►�0/n/�lC��—� Address: Ito V12 M II L) Lie.#:--7 la Phone t(51 -)9 Ccll#: 504 '�103 I9. -53_email: CSC 'hl}-;-,Phan-Idi'5�l�,.ts.4 Company Name:(bL CUL(\ ��.4�P.rvt t �� Addrm: 116 r 0I4 5a.t.j kr 1l ►2.;e/ Ll¢1LL,— of.+ t� 4,Proposed Electrical Work/Fixture Count: 3 l tz f� 07� 52-&o M tc(-i s 5.3i°Party Electrical Inspection Agency: ��S _ fff•11f111f ff/11flf111f1/ff ff1ff/11111ffffflfff►flff 1f11f if fff1ff11f 1fffff 1f11fff1f fff/f1f11f11fflff**fAt STATE OF NEW PORK,COUNTY OF WESTCHESTER ) as: I n' S off A Xv ,being duly sworn,deposes and state.that hd+he is the applicant above named,and does hut:ter t print rmc-jt n,i,i.!:a:.:,,gr,.:n,- .n lh.appl}�.u+u state that(s)he is the for the legal owncr and is duly autbwtzW to make and file this application. ,v tr L�ci��xJ tu4aik:0 the undersigned farther states that all statements contained herein arc trio to the best of hisihcr knowledge and belief,and that any work performed,or use conducted at the above captioned property wil: De in conformance with the details as sei fort'[sid cat W-u:d in dus application and in a"accompanying approved plans and specifi:axons,as we!!as ir.accordance with the New Yori,State I'niform Fec Prevention&Building Code,the Code of the Village of Rye Brook and all odta applicable taws,orduancm.acid teguiations. Sworn to before me this 1 -7 Swam to before rite this 1 -1 d of ,20 day of 20 -)L J azure of Ptvpper Owner re nt n ame of Property OWT Print Nattk of A li r (r L Notary Public— , Notary Public huIdry ..IEULLO ESTHER PErggggmw PJt.N:c,State of New York Notary Public, No.0 State of P'ew York 1f,:c61g,70 Reg.No.01PE62'.9836 Qus.Gtied In YleStchester County Qualified in Westche,ter County ?? C^#nmfss;on Expires j,s,t s y 29 20 � Commission Expires D.acember 30,29�P STATE WIDE INSPECTION SERVICES, INC. Service With IntegritY 080 • • SWIS JOB APPLICATION0. • Oitice Uzi Elect.Permit 0 Date Bldg Permit# L O Sq Ft Plumbing Permit # Final Certificate# City(Village ko Zip OS Building Dept /Q County Address )o f Cross Street Section Block Lot /n !2 Owner Name!Address(if daft--i thdn above; M� ` Contact Number Basement 0 1st FI. ❑2nd FI. 3rd A. More Than 3 FI. Garage Attic 190tutside Residential Commercial Receptacles Special Recept GFCI AFCI Switches Dimmers Smoke Alarms C/0 Detector Hood Trash Compact Amt Amps Range(s) Cooktop(s) Oven(s) Dishwashers Refrigerator Disposal Microwave Luminaires Generator Transfer Switch SERVICE Amperage #Panels 1P 3P #Meters #Disconnect Underground New Reconnect Repair Overhead Upgrade Disconnect Utility ID# Con Ed [—]NYSEG []Central Hudson Orange i Rockland PHOTOVOLTAIC SYSTEM PV Modules 1 Inverters AC Disconnect Junction Box Combiner Box load Center PV Monitor Energy Storage System DC Disconnect 3/ 31 C]Legaitzabon Safety Inspection Consultation Scope of Work DD FEB 12 2025 VILLAGE OF RYE BROOK t BUILDING DEPARTMENT This appticatwn n•a4d for one 11 year him•he date—s d by WAS Th appl,catron n mtendrd to cover the above listed Terns to be rnspacted N at any hrne of rrtspectnrr adMhunal arms nave peen--'pert you are authorized to make the n%;>K! n and adtust the fe�for the adddronal hems impxtrd The appkcant declares that there is no open appkaUwts for the shove address with any othe,nspecuors cuntpany the apMrcant,owner or authorized agent agrees to all the abov rerms and condarons as set forth for the apphc at— Email Address ��C �°r�� T s _( "q S ' Name L P License a / f� ! Date ! �� Signature Address 6 �l d Vr4�v' �y!� C! /,Si City/State y� Zlp Code /J S 2- Company Phone# U State Wide Inspection Services 1080 Main Street Fishkill, NY 12524 a JUL ^ 2 2�25 845 202-7224 Phone 914-219-1062 Fax STATE WIDE INSPECTION SERVICES VILLAGE OF RYE BROOK Email: office@swisny.com BUILDING DEPARTMENT Website: www.swisny.com Service With Integrity BY THIS CERTIFICATE OF COMPLIANCE STATE WIDE INSPECTION SERVICES CERTIFIES THAT: Upon the application of: Upon Premises Owned by: Candela Systems Corp Donald & Marguerite Krom 168 Old Saw Mill River Road 33 High Point Circle Hawthorne, NY 10532 Rye Brook, NY 10573 Located at: 33 High Point Circle, Rye Brook, NY 10573 Section: Block: Lot: Electrical Permit Number: EP25-100 124.73 1 36 Certificate Number: 2025-4275 Building Permit Number: BP25-070 A visual inspection of the electrical system was conducted at the Residential occupancy described below.The electrical system consisting of electrical devices and wiring is located in/on the premises at: 33 High Point Circle, Rye Brook, NY 10573 The Photovoltaic System was inspected in accordance with the NYS and NFPA 70-2017 and the detail of the installation, as set forth below, was found to be in compliance on the 23`d day of June 2025. Name quantity Rating Circuit Type PV Modules 31 Micro Inverters 31 Disconnect 01 Officer: Frank J. Farina This certificate may not be altered in any way and is validated only by the presence of a seal at the location indicated.This certificate is valid for work performed on the date of inspection only. Kenneth Hesselbacher, P.E. C�v 26 Rocky Hill Rd . ............... ID New Fairfield, C.T. 06812 1 JUL 21 2025 L_._-- July 16, 2025 VILLAGE OF RYE BROOK BUIL.DINC PFPA.R i MENT Christopher Hale SunBlue Energy 147 Valley St Sleepy Hollow NY 10591 Subject—Final Inspection Krom - 33 High Point Circle, Rye Brook NY Dear Mr. Hale, This is to certify that the installation of the Solar/PV system was done in accordance with the approved plans. A review of the structural framing inspected by the Sunblue had indicated no defects found and the structure is as stated in the plans. Sunblue has worked with a third party that has inspected the Electrical portion of the project and has found compliance with the approved plans and NEC codes. Sincerely, OF R�.SSF� � m r� � s Olt i{ �U) \\\ Q c t1i �'q,� l80113 '�ssloN Kenneth Hesselbacher, P.E. 07/16/25 Ao ;3 '.lot b� 4�X v -®,viva Lob 40"o, Imo„ �A B'3uilding Permit Check List&Zoning Analysis Address: •� \ I SBL: �� l Zone U J Use l Const Type Other. c Submittal Date: ZS Revisions Submittal Dates: Applicant f 0t Nature of Work: y n \ ,n S�vnj` s P 0��"Q\S . T o 2i 1-\00K NA-"L � Reviews:2BA: APR 16 2025 pB: \ BOT: Other. NEED /OVFEFS:Filing:�� BP: "''' C/O: Flood Plane: Legalization: APP: Dated: Notarized: SBL: Truss I.D. Cross Connection: H.O.A.: ( ) ( ) Scenic Roads: Steep Slopes: Wetlands: Storm Water Review: Street Opening: ( ) ( ) ENVIRO: Long Short: Fees: N/A: ( ) ( ) SITE PLAN:Topo: Site Protection: S/W Mgmt.: Tree Plan: Other. ( ) ( ) SURVEY:Dated Current: Archival Sealed: Unacceptable: ( ) ( ) PLANS:Date Stamped: Sealed: Copies: Electronic Other. (� ( ) License: Workers Comp: Liability Comp.Waiver. Other. ( ) CODE 7S3#: Dated: N/A: ( ( ) HIGH-VOLTAGE ELECTRICAL-Plans: Permit: N/A: Other. ( ) ( ) LOW-VOLTAGE ELECTRICAL:Plans: Permit: N/A: Other. ( ) ( ) FIRE ALARM/SMOKE DETECTORS:Plans: Permit: H.W.I.C.:_Battery:_Other. ( ) ( ) PLUMBING:Plans: Permit: Nat. Gas: LP Gas: N/A/: Other. ( ) ( ) FIRE SUPPRESSION:Plans: Permit: N/A: Other. ( ) ( ) H.V.A.C.: Plans: Permit: N/A: Other. (� ( ) FUEL TANK:Plans: Permit: Fuel Type: Other. O O 2020 NY State ECCC: N/A: Other. ( ) ( ) Final Survey Final Topo: RA/PE Sign-off Letter. As-Built Plans: Other. ( ) ( ) BP DENIAL LETTER: C/O DENIAL LETTER: Other. ( ) ( ) Other. ( )ARB mtg.date: approval;- notes: ( )ZBA mtg.date:. approval;- notes: ( )PB mtg. date: approval:- notes: REQUIRED EXISTING PROPOSED NOTES APPROVED Ana: APR Is Circle: a 6' Fie: Front: Front: Sides: Rear. Main Cor. Accs.Cor. Ft H Sb: Sd.H Sb: GFA: Tot : Ft.I : Parking Height/Stories: notes: D IEC EWE TO: Village of Rye Brook 1 DD FEB 2 5 :202:5 Building Department 938 King Street VILLAGE OF RYE BROOK Rye Brook, NY 10573 LBUILDING DEPARTMENT RE: Krom — 33 High Point Circle Rye Brook This application is for uninstallation and reinstallation of the existing solar energy system on the roof of homeowner's residence. No changes to the existing will be made. We were informed no ARB meeting was required. Any questions, please contact us at 914-222-3510 or MARLA@SUNBLUEENERGY.COM. Yours truly, SunBlue Energy Kenneth Hesselbacher, P.E. 26 Rocky Hill Rd New Fairfield,C.T. 06812 1/8/25 Christopher Hale Sung lue Energy 147 Valley St Sleepy Hollow NY 10591 Subject—Structural Analysis—Solar Panel Installation Krom- 33 High Point Cir, Rye Brook, NY 10573 Dear Mr. Hale, As requested, an analysis of the existing residence in terms of the proposed solar array you plan to install on the existing roof sections has been performed. The replacement arrays of 31 panels on the roof sections will add an additional dead load of approximately 1,5501bs to the roof areas(2.5 lb/sq ft). The roof is constructed with Truss's-2"x 6" Top Chord spanning 18"with support posts at mid span. This loading is within the allowable dead loading design. Sunblue will also inspect the roof for any damages any repair if required. The capacity of sections of the roof structural framing has been evaluated in accordance with the 2020 NYS Residential Code and referenced standards-Designed for 130 MPH Wind-301b Snow Load,has the capacity to handle the addition of the Solar System. Sincerely, Kenneth Hesselbacher, P.E. OF IV kk *Gj �N HESscc p �80113 �SSiON Limitations-Installation of the solar panels must be performed in accordance with manufacturer recommendations.All work performed must be in accordance with accepted industry-wide methods and applicable safety standards.The contractor shall notify the Engineer should any damage,deterioration or discrepancies between the as-built condition of the structure and the condition described in this letter be found.Waterproofing around the roof penetrations is the responsibility of others.Engineer assumes no responsibility for improper installation of the solar array. THE EXISTENCE OF RIGHTS OF WAY UNAUTHORIZED ALTERATION OR ADDITION WA W WSW I 611E WO 2O14 1 pt111rTG d JOB NO.14-063 AND/OR EASEMENTS OF RECORD IF TO THIS SURVEY IS A VIOLATION OF ANY. NOT SHOWN ARE NOT SECTION 7209 OF THE NEW YORK STATE GUARANTEED. EDUCATION LAW Premises known 0S: COPIES OF THIS SURVEY MAP NOT SEARING THE LAND SURVEYOR'S INKED SEAL OR 33 High Point Circle, Rye Brook Area= 7669 s.f. D SALE"COPY. CONSIDERED TO BE A VALID TRUE COPY. GUARANTEES INDICATED HEREON SHALL RUN ONLY TO THE PERSON FOR WHOM THE SURVEY IS PREPARED, AND ON HIS BEHALF TO THE TITLE COMPANY. GOVERNMENTAL AGENCY AND LENDING INSTITUTION LISTED HEREON, AND TO THE ASSIGNEES OF THE LENDING INSTI- TUTION. GUARANTEES ARE NOT TRANSFERABLE. SNOW COVERED GROUND AT TIME OF SURVEY. � y�h A . o .� 46.00. 00, 4�' l91 clo gob 4T.3' e :� +a �a a* ca 0 Q1 Im ore/ •\4k ly No 9 � ?yis3 �NEW Y �•� �' T W \ Survey of Lot No. 96 SUBDIVISION MAP OF BELLEFAIR FILED JUNE 25, 1998 MAP NO. 26190 Lp AND Certified to: REVISED SUBDIVISION MAP OF BELLEFAIR DONALD T. KROM, JR. AND MARGUERITE D. KROM FILED APRIL 12, 1999 MAP. NO. 26335 SKYLINE TRG TITLE AGENCY(SKY-6417-W) situate in the OLD REPUBLIC NATKINAL TITLE INSURANCE COMPANY Town of Rye Village of Rye Brook Westchester County, New York Michael W. Minto, L.S. Section 124.73 Block 1 Lot 36 LICENSED PROFESSIONAL LAND SURVEYOR Scale 1 H 2O' February 25, 2014 NEW YORK STATE LICENSE NUMBER 050871 2 Bell Court GRAPHIC SCALE Lake Ronkonkoma, N.Y. 11779 PHONE/FAX: (631) 5110-1202 20 C xo a a10 CELLULAR: (631) 766-9714 EMAIL: MINTOPRECISION®YAHOO.COM ( IN FM ) I. inch - 20 tt r PROXY STATEMENT Date: To: Village of Rye Brook Town: Address:938 King Street, Rye Brook, NY 10573 Attn: Building Department Ref: Installation of a Solar PV System Customer Address: 33 High Point Circle, Rye Brook, NY 10573 Subject:Authorization for installation of a Solar Electric System To Whom it May Concern: I� Donald Krom (owner)authorize SunBlue Enema(installer)to act on my behalf in the installation of a �i,q 2-kW solar electric system at the above mentioned address. If you have any questions, I can be reached at �l -q3I L,bJp(phone#). Customer Signature Date So, nBlue ENERGY www sunMtMrnrrgy rom <<;.. 7.. '�'.a � w � � ►,, w�, �aa, J' Y hh Y Y hy'. v �� �" '.hfr O rt�r55 � �'�` :O ;�+� L��' rp O 'vF��"�' 0 r,a,'"�'h�,rr/�� 'O i;•{��, ♦• )' v ♦•� 6t ) v tt lvv,,• r 4t I rf •n fti.•.r'il SR'.i r�i' �'R ✓i r I,I//Pik 14/i41i ' 1 �ErIcl�/c/,, t11 `Ie1 ,;1141i�,,rf# '�i/'1'Iim � i0P " �,fit•1•/'t 1• _. � "��N�111•t Bs��N�1,1/ '. .:-�.I,/NI� ._ � .�41 ,,1 �11/,1 �% �1/1 �� �t(OI►►.�,ui f?+�="%.•`c'�..���:: '�eL..�_���. �i��'�;u.��.._�__�.x_..__ti% ��i�._�-�_,.. i:?_:�I�a li.�._ ; 111�1 �.°is .mac;ii:..111�111�;�?i p��'y(,.(0)> w O p cc O co C) O Q f� .'' '.' Zi Ile rA rr .f� U � O c w \ Tay` O U .. f " Z (n > a� -� ��� �G Y 6 cn Lr Z W W O t c :E%•� H mLLI Z n y r o NW '�� w w N O Gaw 1ey� J cn W .. �Le a Cl LL C 0-0 U o Z f , � iC y 04 u N YYYY motto)>� _•�+ZS���.i,�. /O� Y. QJ CJ y (2,� 1rL`.ii:'.'.. .3�7�] \ :�j: ,�r1 iti:,3.• ���T^r,^.: 6 ___.��,..��,::F^._.�.� _.-� ���•�r� "Will IF ,r:9ilj,1,11/1/1��, N Il �'�'. 'its/•1.1i'J'r'j��li�w�EF U�lil•�•Ii}'�� ��� ��E#',.��IIN�' i�l'�iwi4��f',:``G1/11i ��g �'k �i/ ;'Nr7 jl� r1�111`i,� ?� v4> ,► `LJ' : ^� s , �. 7V Ln� 1iE��A N , •• A p �•• A ♦/��' Aj \ y�,pin- 4.•' { 4�:>. hr ..''kn Xr o. 1 v.�: .. r, r! ` r•ry "'Ov�": : +i:jTv ,a . FLORRIV-01 CDOLCF ACORO CERTIFICATE OF LIABILITY INSURANCE DATD/YYYY) `-/ 7/18/218/2024 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsements . PRODUCER CONTNAMEACT Kevin Kelley Levitt-Fuirst Associates,LTD PHONE FAX 620 White Plains Road A/c,No,Ext: (914)457-4200 rvc,No:(914)457-4200 2nd Floor E-MAIL info@levittfuirst.com Tarrytown,NY 10591 INSURERS AFFORDING COVERAGE NAIC f INSURER A:Southwest Marine&General Insurance Company 12294 INSURED INSURER B:New York State Insurance Fund 36102 FLORENTON RIVER LLC dba Sun Blue Energy INSURER c 147 Valley Street INSURER D Sleepy Hollow,NY 10591 INSURER E INSURER F COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR LTRTYPE OF INSURANCE ADDL SUER POLICY NUMBER fMOLICY EFF POLICY EXP LIMITS A X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1+000,000 CLAIMS-MADE OCCUR GL202400013184 7/29/2024 7/29/2025 DAMAGE TISESO R(EaENToccEDrrence) $ 100,000 MED EXP(Any oneperson) S 5,000 PERSONAL&ADV INJURY S 1,000, 00 GEN'L AGGREGATE LIMIT APPLIES PER GENERAL AGGREGATE S 2,000,000 POLICY❑X PET ❑LOC PRODUCTS-COMP/OPAGG S 2,000,000 OTHER S AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ ANY AUTO BODILY INJURY Perperson) $ OWNED SCHEDULED AUTOS ONLY AUTOS BODILY INJURY Per accident HIRED NON-OWNED PROPERTY DAMAGE AUTOS ONLY AUTOS ONLY Per accident $ S UMBRELLA LIAB OCCUR EACH OCCURRENCE S EXCESS LIAB CLAIMS-MADE AGGREGATE S DED RETENTIONS $ B WORKERS COMPENSATION X PER OTH- AND EMPLOYERS'LIABILITY TER YIN 20814927 6/29/2023 6/29/2025 1,000,000 ANY PROPRIETOR/PARTNER/EXECUTIVE � N/A E.L.EACH ACCIDENT $ OFFICER/MEMBER EXCLUDED'? (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE $ 1'000,000 If yes,describe under 1,000,000 DESCRIPTION OF OPERATIONS below E L.DISEASE-POLICY LIMIT 5 B NYS Disability DBL 538714-2 8/14/2022 8/14/2026 Limit-Statutory DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached If more space is required) VILLAGE OF RYE BROOK-is included as Additional Insured for covered operations of the named insured CERTIFICATE HOLDER _ CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE VILLAGE OF RYE BROOK THE EXPIRATION DATE THEREOF. NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. 938 KING STREET Rye Brook,NY 10573 AUTHORIZED REPRESENTATIVE ACORD 25(2016103) ©1988-2015 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD NYSIF New York State Insurance Fund PO Box 66699,Albany, NY 12206 nysif.com CERTIFICATE OF WORKERS' COMPENSATION INSURANCE a a ^^^^^^ 270309206 1 LEVITT-FUIRSTASSOCIATES LTD 520 WHITE PLAINS ROAD, 2ND FL _ i TARRYTOWN NY 10591 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER FLORENTON RIVER LLC D/B/A VILLAGE OF RYE BROOK SUN BLUE ENERGY 938 KING STREET 147 VALLEY STREET RYE BROOK NY 10573 SLEEPY HOLLOW NY 10591 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE G2081492-7 746696 06/29/2024 TO 06/29/2025 2/19/2025 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2081492-7, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTTPS:llWWW.NYSIF.COM/CERT/CERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER THE SOLE PROPRIETOR, PARTNERS AND/OR MEMBERS OF A LIMITED LIABILITY COMPANY THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND. EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STAT SUR NCE FUND T �V DIRECTOR,INSURANCE FUND UNDERWRITING VALIDATION NUMBER. 111065733 U-26.3 G AERIAL VIEW VICINITYMAP Sun IUL PE;- Pol3T# r"�% �� ENERGY S8L# IIIIIVI 7 5,� x R��n��-Rd A�'E * , A ca SUN BLUE ', 147 Valley St. ti BUILDING-1 NSl� Sleepy Hollow,NY 10591 . ,Vis age®f� �; z;y rook, NY1-914-222-3510 -� --`_ CONFIDENTIAL-THE INFORMATION ` HEREIN CONTAINED SHALL NOT BE USED'. .�_` 1 EXCEPT OSUN HBLUE ENERGY NOE BENEFIT OF R r ' SHALL IT BE DISCLOSED IN WHOLE _ OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, ..~ •� '; EXCEPT IN CONNECTION WITH THE �5 � j� A r La Rye i3r0o SALE AND USE OF THE RESPECTIVE Or _ `� EQUIPMENT,WITHOUT THE WRITTEN PERMISSION OF DBM SOLAR DESIGN ' y _ AND CONSULTING COMPANY,LLC •► - tAs-..ray -, �' , `'� a• +Ohildtime of Rye Brook %9 IE ,,' A4 H Enroll By 2/ 8 rs � ,`S �, `{� �} .,•, Save Up To S350 ,� ��. l -P a .I 1 �"•+ � � fir' r FEB 2 5 2025 % ko WHl Solutions V LLAGE OF RYE BROO •.: , - b o ��y, games Edward Burlat,PT B ILDING DEPARTM;=N ► • Vil E{ ; Q $ - s Fed Ex Drop Box v®r III FedEx One ` -VIV Rate Pricing Z M . Ex 12/31 l�6 :- - *, p 6 O C) l.0 Z ° N - SHEET INDEX - SCOPE OF WORK Z x 0 o _�e ww PAGE NUMBER PAGE TITLE _ DC System Size:9.92kW(EXISTING} , ,, �_ A � u- ° a' °o PV01 TI TL E PAGE � � _ � � F 9 �� ' ; y � — Roof Type:Asphalt/Composite Shin le Roof ` ', .; z, ._ Yp9 F . Lu E Set Reviewed By. N �� ° = a� U PV02 SITE PLAN Roof Pitch:5/12, 11/12 ,.: ._E. &_ t PV-041115-011207 �.�s ��:Y .� cn V M W o 0) PV03 ELECTRICAL LINE DIAGRAM Anchored on 48"centers using UL listed racking system UV Resistant cable es no z used permanent wire management in accordance PV04 ARRAY& STRINGING DETAIL Ri bl ties tip ties)} d f P g with NEC 110.2, 110.3(A-B},300.4 PV05 LABEL PLAN Junction boxes mounted flush with racking. ` ♦ ti SPECS SPECSHEETS AND DOCUMENTS , DESIGN CRITERIA APPLICABLE CODES GENERAL NOTES DBM DESIGN WIND SPEED: 120 MPH 2017 National Electric Code(NEC) EXPOSURE CATEGORY:C COUNTY LICENSED DBM SOLAR DESIGN AND 0 Residential Code of New York State A. ALL WORK SHALL COMPLY WITH STATE AND LOCAL CODES. D CONSULTING COMPANY,LLC 202 P:(801)690-4873 2020 Plumbing Code of New York State B. DRAWINGS HAVE BEEN DETAILED ACCORDING TO UL LISTING PLUMBER E:SUPPORT@DBMSOLAR.COM 2020 Mechanical Code of New York State REQUIREMENTS. REQUIRED TO FILE WM.DBMSOLAR.COM 2020 Fuel Gas Code of New York State C. PRIOR TO COMMENCEMENT OF WORK,CONTRACTOR SHALL VERIFY EXISTING 2020 Fire Code of New York State CONDITIONS AND NOTIFY DBM OF ANY INCONSISTENCIES. 2020 Property Maintenance Code of New York State D. ALL EQUIPMENT SHALL BE INSTALLED AS SHOWN. DESIGNED BY 2020 Existing Building Build Code of New York State EXISTING SYSTEM SUMMARY K.Vang 2020 NYS Uniform Code Supplement E. WARNINGS PER NEC 690. DATE F. WIRING SHALL NOT BE INSTALLED WITHIN 10 INCHES OF ROOF DECKING MODULE:(31) LG LG320N1 K-A5 320W PV Module 1/6/2025 EXCEPT WHERE DIRECTLY BELOW PV EQUIPMENT INVERTER:(31)Enphase S280-60-LL-2-US Micro Inverters PROJECT OCCUPANCY& CONSTRUCTION TYPE 2021-SUN BLUE SHEET NAME COVER PAGE OCCUPANCY-R3 RACKING: UNIRAC Roof Mounted PV System PAGE# REVISION: CONSTRUCTION- V-B PV01 0 120'1 Q FRONT OF HOUSE SunBlue LQ ENERGY mww OF tV S'r TM, � 0 SUN BLUE 01 147 Valley St. r- 11.i ..� Sleepy Hollow,NY 10591 4 1-914-222-3510 01 W _ r U CONFIDENTIAL-THE INFORMATION 01 Q � �'� HEREIN CONTAINED SHALL NOT BE �p add 1 , USED FOR THE BENEFIT OF ANYONE M O EXCEPT SUN BLUE ENERGY NOR 18 VENTILATION '�3Sf t7#� SHALL IT BE DISCLOSED IN MOLE � � A JUNCTION BOX OR IN PART TO OTHERS OUTSIDE (E)AC COMBINER PANEL _ RECIPIENTS ORGANIZATION, t - EXCEPT IN CONNECTION WITH THE (E)VISIBLE,LOCKABLE, Exp 12/31/26 SALE AND USE OF THE RESPECTIVE C LABELED AC DISCONNECT EQUIPMENT,WITHOUT THE WRITTEN KPERMISSION OF DBM SOLAR DESIGN U SP� UTILITY METER AND CONSULTING COMPANY,LLC c� 36 MSP(INTERIOR) 3 z 3 z J EXISTING PV MODULES W/A GROUND ACCESS y MICRO-INVERTER UNDER EACH MODULE 10r 15 � W r I � � ao i CONDUIT RUN - ' Z � .-1 ' O in (D� I'_ i0 W Z r- N � 36"ACCESS PATH ;;h�{w 3' 0 c o ,Y W W 3'-7r L L >- Se W E = m CD cV F o coU a? D Cl� Y co m :r DBM DESIGN DBM SOLAR DESIGN AND � .,� CONSULTING COMPANY,LLC r P:(801)690-4873 4 E:SUPPORT@DBMSOLAR.COM i-� WWW.DBMSOLAR.COM •AC DISCONNECT LOCATED 10'OR SITE INDEX N o ARRAY DETAIL LESS FROM UTILITY METER `�s �'� ° DESIGNED BY •CONDUIT RUNS AND JUNCTION BOX PHOTOVOLTAIC APPROXIMATE FIRECODE �,� °o A B C D K.Vang LOCATIONS TO BE DETERMINED IN MODULES DISTANCE TO SETBACKS s� H 0� DATE THE FIELD. PROPERTY LINES ,:: 30 �0° AZIMUTH 2020 2900 1120 1680 • IONS ARE 66.38 — .t L Z���` ,10 1/6/2025 EQUIPMENT LOCATIONS •• 7..l.I..N.'�..F Z.7 APPROXIMATE AND MAY BE :,::.ref' ;^: ,;;; 28 $Q 130° TILT ANGLE 42° 23° 23° 23° PROJECT# ADJUSTED IN THE FIELD , — `"I"'`�'`�"' �'�� 2� , 40 � Qo 2021-SUN BLUE •WIRES LOCATED IN READILY # 26 h ,'so MODULE COUNT 3 3 18 7 SHEET NAME '� ,.. '� a PROPERTY DETAIL ACCESSIBLE LOCATIONS SHALL BE 18 .. -•.y:: ti 0 0 GUARDED PER NEC 690.31(A) N N ROOF SUPPORTS n' S Rafter=2X4�24�I O.C. PAGE# REVISION: PV02 0 e x PV MODULE SPECIFICATIONS INVERTER SPECIFICATIONS PHOTOVOLTAIC AC OUTPUT LABEL PV LOAD CALCULATIONS:SUPPLY SIDE TIE-IN MANUFACTURER LG Neon MANUFACTURER Enphase MODEL LG320N1 K-A5 MODEL S280-60-LL-2-US AC OUTPUT CURRENT 35.03A 200A RATED FEEDER WIRES GROUND UNGROUNDED MAX POWER-POINT C m 9.62 A AC OUTPUT VOLTAGE 240V NOMINAL AC VOLTAGE 240V 200A = 1.25 = 160A Sun lue MAX O -PO O m 33.3V MAX OUTPUT POWER 270 VA OPEN CIRCUIT o G oc 40.8V CEC RATED OUTPUT POWER 280VA 160A (FEEDER WIRES ALLOWABLE SOLAR) ENERGY SHORT CIRCUIT CURRENT 1sc 10.19A RATED OUTPUT CURRENT 1.13 A MAX INPUT CURRENT 15A 160A AVAILABLE FOR PV MAX SERIES FUSE(OC 20A MAX DC INPUT VOLTAGE 48V ConEd Customer Information MAX POWER(Pmax) 32OW CEC WEIGHTED EFFICIENCY 97% Customer Name:Marguerite Krom&Donald Krom 705.12(A)& 690.59 IRAXO G C 1000 V MAX FUSE(OCPD) 20 A Customer Account No.:65449-02000-0 SUN BLUE Customer Meter No.:4461754 147 Valley St. MAIN SERVICE PANEL Sleepy Hollow,NY 10591 200A MAIN BUS 1-914-222-3510 200A MAIN OCPD UTILITYMETER CONFIDENTIAL-THE INFORMATION 000 HEREIN CONTAINED SHALL NOT BE EXISTING EXISTING XXX XXX USED FOR THE BENEFIT OF ANYONE 10 MODULES&MICRO-INVERTERS IN A BRANCH CIRCUIT 100A 1201240V EXCEPT SUN BLUE ENERGY NOR ❑ VISIBLE,LOCKABLE,LABELED DISCONNECT 0 SHALL IT BE DISCLOSED IN WHOLE 10 MODULES$MICRO-INVERTERS IN A BRANCH CIRCUIT ENPHASE ENVOY AC COMBINER PANEL 10'OR LESS FROM UTILITY METER OR IN PART TO OTHERS OUTSIDE 11 MODULES&MICRO-INVERTERS IN A BRANCH CIRCUIT /1 60A 120 240V RECIPIENTS ORGANIZATION, - 15A-2P FUSED AC DISCONNECT o EXCEPT IN CONNECTION WITH THE 45A FUSES SALE AND USE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE WRITTEN - ----- ___0# 0 TYPICAL SUPPLY PERMISSION OF DBM SOLAR DESIGN 20A-2P AND CONSULTING COMPANY,LLC SIDE CONNECTION (TAP) N N ^ JUNCTION BOX 20A-2°p NEC 705.12(A) TO EXISTING LOADS n 0 20A-2P Enphase Q Cable 06 Bare Copper EGC — — — -- - _ - #6 CU GEC OF /V 3 ,�t�t 4 O o Wz -' I-- L- N — Q '' 0 0113 O� W X C,rc� ��, ,.� 0 O o � Yo � W ELECTRICAL NOTES �SIOw S SHALL COMPLY WITH NECAS AMENDED. z 0 O w 3: A. ALL COMPONENTS B. PHASE CONDUCTORS SHALL BE IDENTIFIED W Er m CV C. ALL WIRES SHALL BE PROVIDED WITH STRAIN RELIEF UPON ENTRY INTO BOXES,REFER TO MANUFACTURERS INSTALLATION MANUAL FOR REQUIRED TORQUE VALUES Exp 12/31/26 f— 0 M U D. THE DC GEC,IF USED,SHALL BE CONTINUOUS FROM THE INVERTER GROUND BUS TO THE MAIN SERVICE GROUNDING ELECTRODE SYSTEM Y M E. ATTACHMENT TO GROUND ELECTRODE SHALL USE IRREVERSIBLE CLAMP. F. ALL EXPOSED METAL PARTS SHALL BE GROUNDED USING TIN PLATED COPPER LAY IN LUGS OR GROUNDING CLIPS LISTED FOR THE PURPOSE G. MIN#10 BARE COPPER EGC AT SOURCE CIRCUITS SHALL BE ROUTED SECURELY TO MOUNTING HARDWARE THAT PROTECTS FROM PHYSICAL DAMAGE 0 All Exposed PV rooftop conductors that are not located under the array modules,shall be installed in a listed raceway,and shall include listed junction H. #6 FOR AREAS THAT MAY BE SUBJECT TO DAMAGE boxes at both ends of the raceway to transition from exposed conductors to the listed raceways.In Accordance with NEC 690.31(A)&(B)" I. BOTH ENDS OF ALL METALLIC CONDUIT SHALL BE BONDED PER NEC250 J. INTERCONNECTION PER NEC690 0 ROMEX AMPACITY LIMITED TO 600 VALUES.IF USED,SIZE ACCORDING TO NEC TABLE 310.15 K. ALL WIRES WILL BE RATED AT THHN/THWN 2 a DC Conduit must be marked in accordance with NEC 690.31.Labelingmust be every 10'and must comply with NEC 690.31.See PV05 for Label plan L. CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS '$ M. PV PRODUCTION TERMINATED IN LOAD SIDES OF ALL AC DISCONNECTS • ALL DC Conductors must be protected with metal conduit ,'.r :• ICBM DESIGN CONDUCTOR SCHEDULE WITH NEC ELECTRICAL CALCULATIONS DBM SOLAR DESIGN AND CONSULTING COMPANY,LLC NO. OF CNDRS. CORR. FILL ADJ. CONT. MAX. BASE DERATED WIRE RUN P:(801)690-4873 ID CONDUCTOR CONDUIT RATED EGC TEMP. E:SUPPORTa�DBMSOLAR.COM IN CNDT. AMPS FACTOR FACTOR CURRENT CURRENT AMPACI TY AMPACI TY DISTANCE WWW.DBMSOLAR.COM 1 ENPHASE Q CABLE FREE AIR N/A 12.43A MAX #12 TRUNK CABLE 0.96 N/A 12.43A 15.54A 25A 24.00A 20ft DESIGNED BY K.Vang 2 10 AWG THWN-2 CU 314"DIA EMT 6 12.43A MAX 10 AWG THWN-2 CU 0.96 0.8 12.43A 15.54A 35A 26.88A 20ft DATE 1/6/2025 PROJECT# 3 8 AWG THWN-2 CU 314"DIA EMT 3 35.03A 10 AWG THWN-2 CU 0.96 1.0 35.03A 43.79A 50A 48.00A 5ft 2021-SUN BLUE SHEET NAME ELD 4 6 AWG THWN-2 CU 314"DIA EMT 3 35.03A 8 AWG THWN-2 CU 0.96 1.0 35.03A 43.79A 65A 62.40A 5ft PAGE# REVISION PV03 0 OF I. 11 ".1 <P 0 Sun lue - ENERGY 113 SUN BLUE G al a SI►eel � 'O �` 147 Valley St. Enphase M eiroInv►er.ers z Sleepy Hollow,NY 10591 Enphase S280 Microinverter --Exp 12/31126 1-914-222-3510 CONFIDENTIAL-THE INFORMATION fNRtJT DATA(I)C) S280-60-LLa2-US HEREIN CONTAINED SHALL NOT BE C(ammnly used module pairilggs9 235 W-365 W USED FOR THE BENEFIT OF ANYONE EXCEPT SUN BLUE ENERGY NOR Max'mum input DC voltage 48 V SHALL IT BE DISCLOSED IN WHOLE Peak pmeiertrazcking voltage 27 V,37'v' OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, De.scgned for high-poviered,60-cell modules,the Operating range 16 V 48V EXCEPT IN CONNECTION WITH THE Enphase S280 r a %linfl0ax start valtage 22 V/48 V SALE AND USE OF THE RESPECTIVE advanced TIc-ready L teas--�_-80 Milcroinvefter Is� � p EQUIPMENT,WITHOUT THE WRITTEN Max IBC short c7rcuh cuTrenl 15 AL PERMISSION OF DBM SOLAR DESIGN Microinverter bUIIIof'.t11e "tl1-gef6era Ioft platform anrJ at:l,ie a he OUTPUT DATA(AC) ---- 208 VAC 240 VAC AND CONSULTING COMPANY,LLC highest eff detncy for moc-ule-level p-o%Ater electronics =peak output panwer 280 VA 2-90 VA a ong with cost per Watt reduction-With its aff-AC '-daxr"mt.em con inuOL5Gutput power 270 VA 270 VA approach,the S280 simplifies design and installation,llatlio n, iNominal vc ltagefrar:g& 209 V{183 229 V 240 V, 211-264 V �proac Nominal output.,currert 1-30 A 1.13 A and ceflvers ep+timal ena;rgy hawe _Th-e S280 is Nominal fre-quency/range 60157 r 61 Hz 60/557.61 Kz compatible with storage systems.,QrCluding battery Extendec frequency range 57 63 F-z 57 63 Hz meratgement systems. -2awerfactoratirated power 141 1.0 'AaximL.m un ifs pear 20 A biarnch ciircu it 21(three phase,ba anced)I 14(single phase) The Enph,a se 9280 inte-grates sesrnles.sly with the M, aXiTn m outp Lit fa►.:ll current 663 MA 5,100►rns 663 MATM8„10 0 ins Er phase Ervoy-S`ct+rmmuinUcati+Ons g Bte'ovay,and Power fac>lor(adjustable' 1 10 7 lead ng_.-0.7 lagg In g 1 f 0.71►ea d ng—0.7]egg Ing Enlphas.e Enlighten'monitoring and analysis software. EFFICIENCY + 2�08 VAC 240 VAC CE1Cweighted effiJericy 96.5% _7.0% Peak inverter efl'icFier ey 96.8% 97 3% M � M EC HANfiCA L DATA O � .. O Am bi ent tempefrature range d OTC tag t650C � N — p W Productive ,� �� Z PSI CGnnector type tOC4 compatible lock,ng Q } Opo°mL-vad fera high&—poi @r.60-,coIO rriodulag D+i►-jen&ians,(1lixF=xD) 172 r-.m x 175 mm x 35 mrn(Wjt: .out bftcket) � -0 � z � x ��'elghl 1.B kg(a 16s 1 0 r- O -�z W W a 11d'i, 1'ii2 d IrTI rjt of hat:in cu i, rld debris OGrIing KalwatCor-vec ion•ha fans, LL O p-, 0 •.• *,,, _f � Enclosure ea-vironmenrtial Fasting GuIdOX NEA1A 6i z � � � >- Se i>> — FEATURES W = m U N Corn atib"lit 60 ce'I!PSI windulea N ��r�ply s,nc���:��.b�e P �` ~ ° M >' U � Gammunica:tion Power line U) � M W 0 � { No GEC na�ded for m1eroinvefter' ,- -,� 'nteg,rBied gro��:n� TI-I=DC corr;uit mews the reqtriQ�emenita for ungrounded 1�1f arrayrs yrt a + �DC d� I�aI it r'r �9�u 91i r qu rid NEC 6Q-0.S5.Equipment graund is prr�ded'n the Engage Cahte.NG adcli ion�al GEC or�grounu is -(° required.Ground faijit restection �GFP'is fnte r��ated into the microirwerter. 4 N ore than rni I am h our..O;testitig 4� P � � g 1 ,,� Pa9Gnitcrintg Enlrighlen%farkager and"'i'vEnlighten moniiteri�ng gptirams I r�dustry-a adi rt �+ r�r rat up to 2a VeArS 1, C mP liance UL17411IEEE1.547,FCC Part 15 Class B, CANIC C22.2 NO-0 M91.0.4-04,and 107-1.31 �� logo A� PI>� G Grid Re i is prod uct is UL Listed as?V Rapid Shut Downs Egl.dpment:.and confc,ma with N EC-2014 and � 9 '�E.,2017 section 693.12 and a22`.1.2415 Rule 64.2.10 Rapid Shctd�ATk Gf PV S.ylrtems,faiAC} e w i lh fy �d � r f� to r ir�l'i v rtidow) and�DC concu�ctars,wrhen 7nsf al'ed accalydtng m-anuf`actLrer`s instructions_ DBM DESIGN Coor pI � � �requertty t de-thraugh decluir►ymarite; 1.Saggesi'ajn on,y,inverter se.I limits�C irnpuYs4 DBM SOLAR DESIGN AND y Rernoto-u pda ling to rospond to ohanging g-i'd 2.Nc mi na.vo tagle range•can be ext:enrJed 13-eyond n► rninal if regLired bit the urtilil . CONSULTING COMPANY,LLC requirar;pots P:(801)690-4873 E:SUPPORT c@DBMSOLAR.COM F Co n figurab @ for vat ah le gr id pmfi 10-S I ke WWW.DBMSOLAR.COM Haw a!lati F-[Pc�rio+ ornpany(HI CC)Mule 1404. Ca Iforn a Rde 21 DESIGNED BY K.Vang DATE a 1/6/2025 To I earn more about Erphase of feria g.s,11r'tsft enphase om, PROJECT# e'2N 2020 Etryp i��ie,gy All�,ghls fair-e red.A--ir-ada aj ks cc brsi J�rJ��tla_zM. p c r.%-* 4�+'`EitoN asA Ei�rgyt,Im, 2021-SUN BLUE ENPHASE ' ENPHASE. To I eaTr more about Er �ase of feria ;.past en G ase�'I om %1 202z3.02-�3 Dab nbjed to-change. � SHEET NAME R g , � SPEC SHEETS PAGE# REVISION SPECS 0 GROUNDING DETAIL JUNCTION BOX DETAIL OF s�D�+fiVUEE60 BONDING SM MID CLAMP BONDING SM END CLAMP ; .. �t H ES un9lue Co-F F-o 0 0 0 ® 0"; �� �, slit ENER G Y I RAIL MOUNT rr rSD. TERMINAL BLOCK ' Li P SUN BLUE TMCALSPUCE P WAL WEEBLUG CONDUCTOR-UNIRAC P/N 008002S: Apply Anti Seize and insert a bolt in the aluminum rail and through the clearance — � 0a80 1 13 147 Valley St. tale in the stainless steel flat:washer Place the stainless steel flat washer on the bolt, VARIES-REFER TO © Sleepy Hollow, 10591 oriented sD the dimples will aomact the aluminum rail.Place the lugs portion on the � SHEET SM-F04 I�-��10%.4 f 1-914-222-3510 bolt and stainless steel flat washer.Insult stainless steel flat vvasher.lock washer and TVRM8W0&aMm.,r nutlightenthe nut until the dimples are completely embedded Into the rail and lug- TORQUE VA UE 10 ft Ih;1See N:it(;on PG.A) $ CONFIDENTIAL-THE INFORMATION Se.:p;cductdatasbcc-formwedr:tails,Model Na.%VEM--LLC-6.a Exp 12/31/26 HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE � ® EXCEPT SUN BLUE ENERGY NOR ATTACHMENT DIAGRAM HEYCO-TITS UL LISTED/RECOGNIZED AND SHALL IT BE DISCLOSED IN WHOLE CSA CERTIFIED LIQUID TIGHT CORDGRIPS OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE Cantilever= 33% of MAX rail span SALE AND USE OF THE RESPECTIVE Module Overhang EQUIPMENT,WITHOUT THE WRITTEN PERMISSION OF DBM SOLAR DESIGN AND CONSULTING COMPANY,LLC 25 ATTACHMENT DETAIL 50 4"BETWEEN ROOF AND PANELS 25 ROOF SURFACE FLASHING 4" Rail PV Module z � 0 w Ur) w 0 L _o N Z 48"MAX rail span with staggered attachments to distribute weight across support framing 2.5" U >- U) U) � Z � >G Diagram: Grid-Tied System W/Micro-Inverters 0 c ,� w w 9' � o °o Z o .� a'm W E _ u) CV 5116"STAINLESS STEEL LAG BOLT ~ O M >- U AND FLAT WASHER U) Y- ce) W 06 PV ATTIC DETAIL � En hose Micro-Inverter � JUNCTION BOX .0 moo + - + - + - + - Enphase Q Cable DBM RESIGN 5'S" 4' DBM SOLAR DESIGN AND CONSULTING COMPANY,LLC /V X/V /V /V Junction BOX SOLAR MODULE P:(801)690-4873 E:SUPPORT@DBMSOLAR.COM VW 4" VW.DBMSOLAR.COM DESIGNED BY PV Source Circuit To Load Center K.Vang Equipment Grounding Conductor DATE 1/6/2025 PROJECT# 2021-SUN BLUE SHEET NAME BRAY/STRINGING DETAIL PAGE# REVISION *See Attached Data Sheets For More Information P vo4 0 P V 3►, V WARNING ld 4.5" L '' 4.5" ELECTRIC SHOCK HAZARD WARNING:PHOTOVOLTAIC DO NOT TOUCH TERMINALS CAUTION: Sun lue TERMINALS ON BOTH LINE AND POWER SOURCE PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED LOAD SIDE MAY BE ENERGIZED ENERGY IN THE OPEN POSITION LOCATION:(1)COMBINER BOX(2)JUNCTION BOX LOCATION:DC CONDUIT(EVERY 10 FEET) (3)BREAKER PANEL(4)DISCONNECT SWITCH (REFLECTIVE CONDUIT LABEL) B C ( ION:LOCAT 1)MAIN SERVICE D SUN BLUE (5) INVERTER(IF USED) 'q PER NEC 690.31(B)(1-4) LOCATION:STRING INVERTER(IF USED) 147 Valley St. V 4 5" V Sleepy Hollow,NY 10591 1-914-222-3510 4.5" L PHOTOVOLTAIC AC DISCONNECT 4.5„ Id* '' 4.5►► '' MAXIMUM AC OPERATING CURRENT.' 35.03A CONFIDENTIAL-THE INFORMATION 240V WARNING: WARNING: HEREIN CONTAINED SHALL NOT BE WARNING:DUAL POWER SOURCE NOMINAL AC OPERATING VOLTAGE. Q INVERTER OUTPUT CONNECTION USED FOR THE BENEFIT OF ANYONE SECOND SOURCE IS A PHOTOVOLTAIC SYSTEM DO NOT ADD ADDITIONAL CIRCUITS TO PANEL DO NOT RELOCATE SOLAR BREAKER EXCEPT N ENERGY BLUE SHALLTS U DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE LOCATION: 1 MAIN SERVICE EQUIPMENT,WITHOUT THE WRITTEN ( � PERMISSION OF DBM SOLAR DESIGN LOCATION:(1)MAIN SERVICE G (2)AC COMBINER PANEL H AND CONSULTING COMPANY,LLC LOCATION:MAIN SERVICE E MAIN SERVICE&ALL BACK FED PANEL BOARDS F (2)AC COMBINER PANEL (3)ALL BACKFED PANELS LABEL NOTES A. RED BACKGROUND WITH WHITE LETTERING "PHOTOVOLTAIC SYSTEM EQUIPPED "RAPID SHUTDOWN "PHOTOVOLTAIC SYSTEM OR YELLOW/ORANGE BACKGROUND WITH WITH RAPID SHUTDOWN" SWITCH FOR SOLAR PV SYSTEM" CONNECTED" BLACK LETTERING J L B. MINIMUM 318., 1 LETTER HEIGHT YELLOW BACKGROUND WITH BLACK TEXT C. ALL CAPITAL LETTERS D. NON BOLD TEXT SOLAR PV SYSTEM EQUIPPED E. MATERIAL SUITABLE FOR ENVIRONMENT F. SIGNS MUST BE REFLECTIVE WITH RAPID SHUTDOWN z M G. SIGNS MUST NOT BE HAND WRITTEN 0 w i w TURN RAPID SHUTDOWN MAIN SERVICE PANEL I- S. o N SWITCH TO THE"OFF" OLAR ELECTRI Q V >- U) U) POSITION TO SHUT DOWN PV PANELS PV SUB PANEL FOR ILLUSTRATION ONLY �_ z � � � � PV SYSTEM AND REDUCE (IF USED} (NO T A C TUA L MSP} � �- o O� o W W " SHOCK HAZARD IN THE zo � 0 U) ARRAY >- W E = m � N (YELLOW WITH BLACK LETTERING) K A A ❑ ❑ ❑ D NT Ilk � ,s OF Ivy STRING � R H L .. 11Ell& INVERTER I DBM DESIGN 0 AC •` -P (IF USED) F K DBM SOLAR DESIGN AND z ;� CONSULTING COMPANY,LLC . ► �. DISCONNECT P:(801)690-4873 in JUNCTION I E:SUPPORT c@DBMSOLAR.COM •, (IF USED) WWW.DBMSOLAR.COM BOX 0113 (IF USED) A C A F J FOR MICRO I VERTERS ONLY �-� ``r F S 1 T DISCONNECT DESIGNED BY s l oklo (NO KNIFE W ) K.Van g '� K A DATE Exp 12/31/26 1/6/2025 PROJECT# 2021-SUN BLUE SHEET NAME LABEL PLAN J PAGE# REVISION PV05 0 Q 1 Y 0F � o MEns un lue ENERGY O " Q 0113 SUN BLUE N'2131ack _ � 147 Valley St. -Iu, Sleepy Hollow,NY 10591 LG Innovation - -- 1-914-222-3510 Life,s Good Exp 12/31/26 aBetter Life CONFIDENTIAL-THE INFORMATION Mechanical Pr©peTties Electrical ProperttiPs STC HEREIN CONTAINED SHALL NOT BE - ---- - - -- - - - -----_ -- •- -- -------- USED FOR THE BENEFIT OF ANYONE cIls -' "Jiadalc LG320NI �°"" EXCEPT SUN BLUE ENERGY NOR L Cell.Vendor ,G � ilJtlaxirrnum Power(Prig) 32G SHALL IT BE DISCLOSED IN WHOLE Celt Typw dftmcrrlal►-le 1 N type MPP Valr'tage(Vmpp) 333 OR IN PART TO OTHERS OUTSIDE Cal.l.D mensinr..s 161 7 x 161.7 irnnt16Indies MPP Currenitif lrr p► 9.62 RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE cif®ustz• 12; A jlti Wire Buhr) Open Carcuuk trattaM I�.'M 44.B SALE AND USE OF THE RESPECTIVE DiiiinensionslI x VI x� 1 6 y 10 .�13 rim Shart CiircuitCurrertt I Isc) 10.1'g EQUIPMENT,WITHOUT THE WRITTEN 56,30x 40 x 1 57 m&-t -T �yMdule EIf4wrcr 1 a.7 PERMISSION OF DBM SOLAR DESIGN Fmrtt Load �Pa a Opwa6 gTamperaturc -40-i90 AND CONSULTING COMPANY,LLC Rear Lind 5 `' xa Maximum,S�mwrn,Vultage 1,000 +.�J4t=it�l+t 1 a :t !4i'lamfiximnSin-sies Fuse Rm6hg 20 CcmneetarType 'MC4 Pwiver•Tabu—wee(%) 0-t3 Junction 13cm 11P53-J'dth3 Rfi:.,.s Dmde; SST=(Stmalcd n�ti-n curi�frrac'k�e�o i1f:I�ddhr?; mtr�rt:T frrr_1v2�S'c,►,tt115 Cables IODD-r-n x 2 M •Tho mo n+-,LRplt-afr mnpf-ra trek'-=dj--!Itrntrnrd LyL .,drzrz=r uL-ti wvk ail_huAry a_--!must- *-ha t.vir A;..wgp,-rr Air rIfir.r%J: U1 h§1='rr rr�a tip 1050 Odrrr2A-3 9":'h GC�s �I g�r 6c�l�m� ter.T�emPer�l C L FTarrlc Anadaed ldwrun•t;-r. Electrical Properties(NOM) Certifications and Warrant Module LG320N1K-A5 Certifications EC 61215,ICC 61730-If-it maximum Ptr�r( tnax) "S Ne ,�D'��� Q yL [ARP�.rc•�'ft2ga r�rpF) 30,E LG CL 61TD �c 1 Salt nrA cclrri:-jL,r Le,Q MPP Currrert inpp) [C52715(Am-nrmis ccrraszar tr-st Open CiircuitWtage(kfarc) 3B.C+ 150 9001 chart Circuit Carrant(ism] a 20 X!udmla Fire Pur urmance(USA) Type 2 *NOCT(rhrmni!) isaji_r!Tr=;vrjtue}'rAtm:u 110-W,14u',a Evrt i,'-Vr-g-_Ta 2D If rsl q,,vd i z � *."NFire Rfatirrg(EANADAp �Cluss C .. Ln W Z LG�new r ndl.le LG�eON'4 2!adopts Cebu technology. � f-- �-- O N Z (� �,�'• 1 Rre:lurt l+h'�rr�rr�+ i�p�r� � C+Ab tet_hnabogy r p. 2 bus6ar•S with 12 thin voinet 4LR40r 4s'BRY:r Cluiput101wrantyof P.mzm _i.'iv r•wz ant '� Dimens6o Ls(fT'ITi16n) a U (n to enhance pc-o�nut ult and reliability.LG NeO N"' %OV CE ,• Y r_ +, z _ t ! C �.d +� �ESS Aw.•)►�Y 2m-�jCt '(�J.' JiR� tHl{�dd'� -s�'Ca'1,.� GLG� 60 celldemonstrates LCD's efforts to increase custorr�r's vabes � : � � X [ Intern. �s �, C: p � W W � nd e�em It feat.rr�6 enihanr Lil%rarr�anty clurah�li ff,. r LL O O I— p erff3rmance u nd'O-r r�l enrcri rjnment,and aesLheti�c Temperature har�ct�tn g Z 0 s O U) ?>> demgn su ita[Aa fcar rvi F� . .1 NOCT 4 5=3 lc - r _.. _ m � 0-17T.tT IW— o = U)� � ADC rrRL VJ :5C ♦�03 Vxe'C Performance e�rrt24l�1 i3i.l:ly Enhanced Performance Warranty High Power Output — _ ____ _ LrL � _ ' Characteristic Curves 34=� a+wla!! rtsr - a e,, taentlni Compared:�iiih ire-Actis rYtt?deLs,Ehe LG rteCIi'N Z 8tock ■1lo�.rtr¢�n L�i�leDfti .Z ualuGiYY Ilan an E1'�Tta]lt:..d,�?rf�GrlT�r�..d13]'ra�ttr ooi!le7t[it3.Ir: P � ® ca aMvrm'�ag[�sartrasarlo4'R•p 1�8,1P1a1191"i1!pIrT-rr - tCO26% 0 dayThe mrvt.�:d, has been designed in signift�Ly erhante is alspurr - f- e _ `• `';` ti r to 43.55 yr.Even a.:er 25 years, cd quarantees 1 2%p efficiency,therehr mdldi-a t eYrient e rr rm lirWted space. rrez-ore ourpur than e'rra pi evious LC NeaNr-""2 Hfack modu.s. �T�>{f[r „ Aesthetic Roof Outstanding Durahl(ty r lose !` DBM DESIGN r LG t4JeZ]II r'"'2 8lacrtC has bean s gned Y�izh�-thetlrs in ;�:•. - S.'dlTh iEs ne-�0+ iTeanfnrced frame design,LG has z•�tend - -� Momft.lr. al I!■ �t M7St�!!i!M9a L!M f + -that appear al]b]a&a.a distance. uUmalt�ia rn ttw-war'�r,ty of the LC i!_ON'11 i i�`,rack for an additvinat mrl<:.�Thinner bw yes. L:ccr®cnIIII-e �. DBM SOLAR DESIGN AND L'------....=-� - The product� help increase the tralue of a ro err° aiiCr>i — 2 years.Addidonalliy,LG ND0P�2 Stock can endure a n-+3�t P �+' p P ,P � i1:5 mock-m design. load up:o B0Ba Pa a.-.c a rear lop-1 up co S4 Pa CONSULTING COMPANY,LLC P:(801)690-4873 r 140 E:SUPPORT@DBMSOLAR.COM Better Performance ol� >Jntny Da �';'? [ uble-Sided Ceu Structure t,,, ---- i� WWW.DBMSOLAR.COM ■.s�[n t Iri:'t;ssl�:�� &%111143 # LG NeDtVu 2 R k I aw perfanns better are sunny days lI! TIw Tear of the cell used in LIS NeD N'-14 2 Blackvidi caritrihuEe to im ■'�7[tC•[BE��t9!c ra Pltlirt[/1>Tt�! •� ----� still n lrn9;r!!=� a• r �tt['>"!a ltia nera gat lime the fry the light:bi?am reflEc ed fra-m the � thanks G3 Is irrprr�r�erJ temperature+�oeRic.>�n�„ ,:f���®�,*t!a � �• 1� mil.eaniu�r,, urrusdc.�iro, :ra. " - - - r� ��u1 of the rr� :�reabsorbed_o generate a great amo3nt of � %I - DESIGNED BY 3ddi-niona;pottkar. K.Vang 41) DATE L`�—`�, 1/6/2025 � `'darn&riar ca SnUr®a;sire—w;Teri r'rf.srisr:g .iri;iDtnrN WOO 4 d.1L4tt 1!6 h31•ny-A'Ai 0eA f rK11itH °,�EiarlRa�r*.S uS.&tnr. � IN PROJECT# About����� z + �r3 '��' 2021-SUN BLUE U111A•risOd 1 C1 ,tran one,E t rt 9 Clll,ftill C r- r-la 'P q imp Y g ng 9� i'r 9 Lc y.- b:n17r LO ELr-i*anms A:ri t"rr-wrnrd. rmn:ra Lkn Ima eeusr uilt �.G El--xtr�anlrs�a_,lrh.71 �r-n,ha•has l:ts[+i'r,-ammh:e:i t�a arr:ir .rs �arJc t�scd an sai�r r�ci htss+ntsss as rs:�cxtr�t r:>NrFft a .s 1A:r�resr�rbird tYA:a�a9;�anttiT +r.�ttrc,t�-ese:-ri- r_r,��rs ��'� � 1;Q5,suppxwd try LG Grcr t*,rich cospenen:e in semi ca-dxta[.LCL'r,cl-Kvd.try.and r-xtttenals InduM We suw_�sfujy rexased--,e first"Jan-3-K*toner.to t-in madrt in 201 C M-iirh uxre abpw..ed v_32 r•t`0E7f`•''A a:rsrrg1qceam G 11L1.i Ia17 SHEET NAME MA-:rim in thy:•Gal6,.%A Zyews,,tarrato:trt.r+]1:k LG 4r4"'J"'r pm,bxnly b-rAvn as-Moo Ov r•li,-Vt I,Nan'tnrrfsalw Rarar'which prmod L1S ato Ise dm cf Laay.arfon In cttn indu v.r}- ' 'n nm � SPEC SHEETS PAGE# REVISION SPECS 0 un lue ENERGY i SleepySUN BLUE ey NY . 1 1 CONFIDENTIAL-THE IN •' ` • HEREIN CONTAINED ' NOT BE USED FOR THE BENEFIT OF • SHALL IT BE DISCLOSED IN WHOLE BETTERDESSIGN'S' EXCEPT SUN BLUE ENERGY NOR TRUST THE INaUSTRY'�5 BEST DESIGN TOOL --%�= OUTSIDE RECIPIENTSORGANIZATION, CONCEALED UNIVERSAL -rl aEXCEPT IN CONNECTION WITH THE i ■■ , Start the design process for every project in our 13-13u:lder un-lane desggn tool. ENDCLAM.PS SALE 'USE OF _ Its a gr.-al my to sal1e time and rulaney. " • PERMISSIONOF DBM SOLAR AND CONSULTING COMPANY,LLC ti ONE SYSTEM-:MANY APPLICATIONS - Quickly set mdule.s flush t>o fN roof on steep pitched r�oafs_Oriunl a,lar6,e variety ref rnodul.m in Portrait of Landscape.T91t th.e sy,terrr up on flat QIr l0�1U1 Slow roofs. � . END CAPS INCLUDED P-. Oo;mp6ler�ts avail able in T.i11 clear;Gild dark nrll5hes to optilriiie ofli deign financials -- WITH EERY EN®CLAMP and aaslhctics. - i f K '� sr MAXIMIZE FROFITABLLITYON EVERY JOB CONCEALED Tmsst Unirac to help you•,minirriiz:c both systern and labor mts trsm the firm,N.c A is UHI 'ERSAL quoted to the timc yourteam� get off the rout.Faster installs.Les;l���ste-1}1o�e Profits. .�-� � CLAMPS _ UNIWE,RSAL SE11.F co �uwlRar 'BETITEIRmejul ��� � STANDING MGDCI.AMP'S �I • �.. . . � _ WORK WITH THE INVUSTRIES MOST EXPERIENCED TEAM Pr>oiessional support faT p,rofa, opal installer's and Lsignar ou ha'ie access to --, _ - - co .. our technical support and training grlDups_Whatever your suppoit needs,vi-c've gof ' I �"►, 1 I F •p YIAHion.co�md.V-st Un'rac.comlarmunt for m Wornat • •OPT101AL • • Cf) 3: RONTTRIM FUL1-VII�IH �1(Y �, - I-B!ll1lDlER ONLINE DESIGN w E m .. — -- -- -_ TOQL SAVES TIME.&MONEY • • ��1=4`V-4 c�N Vis!t deurlgn.unirac.coin LU .` F-- [I�9E0H�f;IC;�Lit0A0tf�0 -' 1 r ., - _ .�__, _ ,.�__-____` _ - =• - S'�STE.ktfIRE OL�ISS(FIC�►TIC�1V -- r- hi IN - F PR02""'CiT c-Ur"POr' "T HINEST LEVEL 0 U U o r. KI Er"VICE MEAM Tn' U N IR,A C U ST ON'[R S r, DBM DESIGN r ' t--- __ I ��• DBM SOLAR DESIGN AND CONSULTING COMPANY,LL CErRT°IM0 DES,?G'; - :/ 690-4873 a. 6'4u[ELE.NC uVAR i;':7�Y TOO[ �'DO€l;,4£����'10?� P-•' . .: • •' • VNM.DBMSOLAR.COM TECHNICAL SUPPORT CEIRTIRED QUALITY PRDVIDER BANKABLE WARRANTY Unira`stc�l nical support teorn i;>dedicated tolar�s�►eying U lilac rs.he orgy P11 mounting�Ieir1dbf with ISO Don't le�;eyour,prolect Eo chance,Unirac has the BY questiores&addres.sinffrssu€sinrealfinle_Anonlim certificatimsfor00012600-1461.'200.11,andMAS f-ancialstsengihtobackourproductsandred�uctiyourtisk_ ' library of documents includinG enaineori'ng r�eo.drts, 1800120GI,��rhic,h means�ledeliver�h�highest standards flm peace of mitknnivin�yau are pfou7aingptoducts of • THE PROFE.SSIONALS" � I.� S.. � c+r a DATE stamped tettem and tec.11mcal!data sheets great ly fw fff,form,and funGtion..i`he�e ceriit c3t>;ons demofnstiate exceptional gH311ty.501,RM01,1��t i�comi-ed by a 205 y-ar simpUlfcs your perinitfmgandpi�►ivetplannifrgpfocPss. oure;<ccellenceand.eammitmenttoiirlclassbuustrcenprac?i ". Iiimitedproductt��,arraiityand-a5ZeaTlirnitedfids ti�car�anti • 1 11 Hill 11111111111111 Ill 1111111111111111111UIII1I1111111111 Hill 11111111InIIIIIIIIIIIII111111111111,111111111 Hill 111111111111111111111111111 Dill 1111111.1111111111111111111111111111111111111DIIIIllllll Ill I IllI it I Dill 111111111111111111111111111 Hill Ill 111111111111111111UIII Ill III III Hill IIIIIII III[I111i1.1111111.111011[Hill Ill Illillillilloilli11111. PROJECT# B EST I NSTA LLATI 0 N EXP ER.1 E NICE�•CU R B AP PEAL�CO M P LETE�SO LUTka N's UNI R AIC S U PP O RT r � ��d .� ,F �u �.; 1 I HANCE YOUR REPUTATION WITH QUALITY RACKING SOLUTIONS BACKE3 BY EK'GINEERRIG EX ELLENCE AND A SUPERIOR SUPFU CHAi'l SHEET NAME. F01R QUESTIONS OR CUSTOMER SFFUICE VISIT UNIRA0 C0V1 OR CALL (505) 248-270,2 „�J���•� -.;]-��;,r.I�rJJG�:+If. FOR QUFSTIO�IS OR CUSTOMER SER�IICE VISIT flNIRAC-COM OR CALF. (505) 248-2702 SPEC SHEETS SPECS 1