1. REPLACE EXISTING WOOD DECK WITH NEW
COMPOSITE DECK.
APPROXIMATELY 19'-5" X 19'-4"
r
- 2015 INTERNATIONAL RESIDENTIAL CODE
- 2016 NEW YORK STATE UNIFORM CODE SUPPLEMENT
- 2015 INTERNATIONAL EXISTING BUILDING CODE
- 2015 ENERGY CONSERVATION CONSTRUCTION CODE
- ICC / ANSI A117.1 - 2009 ACCESSIBLE AND USABLE BUILDINGS AND
FACILITIES CODE.
-2015 INTERNATIONAL ENERGY CONSERVATION CODE
-2013 ASHRAE 90.1
-2016 SUPPLEMENT TO THE NEW YORK STATE ENERGY
CONSERVATION CONSTRUCTION CODE (Revised August 2016)
ALL WORK SHALL BE IN ACCORDANCE WITH THE 2015 IRC AS
AMENDED BY THE NYS 2017 UNIFORM CODE SUPPLEMENT & 2016
IECC AS AMENDED BY THE NYS 2016 ENERGY CODE SUPPLEMENT
AND LOCAL JURISDICTION & FIRE DEPARTMENT REGULATIONS,
T-1.0 TITLE SHEET
G-1.0 GENERAL NOTES, SYMBOLS & ABBREVIATIONS
t DEMOLITION DECK PLAN,
PROPOSED DECK PLAN AND FRAMING
TYPICAL SECTION
4
El
DEPARTMENT
11.25.19 ISSUED FOR BUILDING
PERMIT
NOTE:
1. VERIFY ALL CONDITIONS IN FIELD.
CT�= NEW CONSTRUCTION
EXISTING CONSTRUCTION
ARCHITECT.
EMILIA FERRI ARCHITECTURE + DESIGN
42 N. MAIN STREET, 2ND FLOOR
PORT CHESTER, NY 10573
c: 203.545.7761
o: 914.305.6210
f: 203.813.3860
emilia@emiliaferridesign.com
Certificate of Authorization
Signature and Seal
Professional License Number
CT: 0011978 NY:033560
Project:
233 TREE TOP CRESCENT
RYE BROOK, 10573
Sheet Title
TITLE SHEET
scaie NT5 I EF Drawn 2019.019Project 0
T=1 v0
0 Emilia Ferri Architecture + Design, LLC All Rights Reserved.
T1 471 F-Axt
i
& -
AND
F.A.1 -
FRESH AIR INTAKE
ADJ -
ADJACENT
F.D. -
FLOOR DRAIN
AFF -
ABOVE FINISH FLOOR
FIN -
FINISH
ALUM -
ALUMINUM
FIXT -
FIXTURE
ALT -
ALTERNATE
FL/FLR -
FLOOR
APPROX -
APPROXIMATE
FTG _
FOOTING
ARCH -
ARCHITECTURAL
AVG -
AVERAGE
F.P. -
FIRE PROOF
FT -
FOOT OR FEET
BLDG -
BUILDING
GALV -
G.0 -
GALVANIZED
GENERAL CONSTRUCTION
BLK -
BLOCK
GEN -
GENERAL
G.F.I. -
GROUND FAULT INTERRUPTER
CLG
CEILING
GL
GYP. BD -
GLASS
GYPSUM BOARD
CFM
CUBIC FEET PER MINUTE
GYP. FB -
GYPSUM FIBERBOARD
CA -
CEILING HEIGHT
C.J. -
CONTROL JOINT
H.B. -
HOSE BIB
CL =
CENTER LINE
H-CONTR -
HEATING, VENTING, AND AIR
CLOS
CLOSET
CONDITIONING CONTRACTOR
C.0 -
CLEAN OUT
H.0 -
HOLLOW CORE
COL -
COLUMN
HD -
HEAD
CONC -
CONCRETE
CONST -
CONSTRUCTION
CONT -
CONTINUOUS
INT -
INTERIOR
CONTR -
CONTRACTOR
INSUL -
INSULATION
CT -
CERAMIC TILE
IN -
INCH
DIA -
DIAMETER
KIT -
KITCHEN
DEG -
DEGREE
DEMO -
DEMOLITION
LAV -
LAVATORY
D.H. -
DIM -
DOUBLE HUNG
DIMENSION
LBS/# -
L.C.0 -
POUNDS
LEAD COATED COPPER
DN -
DOWN
LDR -
LEADER
DR -
DOOR
LF -
LINEAR FEET
DWG -
DRAWING
MAX -
MAXIMUM
EA -
EACH
MAT -
MATERIAL
E-CONSR. -
ELECTRICAL CONTRACTOR
M-
MINN -
MECHANICAL
MINIMUM
E.F. -
EXHAUST FAN
MISC -
MISCELLANEOUS
E.J -
EXPANSION JOINT
MO -
MASONRY OPENING
EQ
MS -
MARBLE SADDLE
-
ELECTRICAL
MTL -
METAL
EUELEV -
ELEVATION
ENCL. -
ENCLOSURE
N -
NORTH
ENTR. -
EQUIP -
ENTRANCE
EQUIPMENT
N/A -
NOT APPLICABLE
ETC -
AND SO FORTH
N.T.S -
NOT TO SCALE
EXIST -
EXISTING
EXP -
EXPANSION
OC -
ON CENTER
EXT -
EXTERIOR
OH -
OVERHEAD
OPNG
OPENING
MATERIAL LEGEND
i H
0
D1
1
4 2
3
DETAIL NO.
xx DWG. NO.
x
X
X
X
X
CONCRETE
CONCRETE MASONRY UNITS
BRICK
METALS
COMPACTED GRAVEL
EARTH/UNDISTURBED SOIL
DUPLEX RECEPTICAL
OUTLET
W
OUTLET FOR WASHER
D
OUTLET FOR DRYER
RANGE OUTLET
Z)
EXHAUST FAN
TELEPHONE JACK
TELEVISION JACK/
CABLE
L/)
DATA JACK
WINDOW TYPE
(SEE SCHEDULE)
DOOR NUMBER
(SEE SCHEDULE)
INTERIOR
WALL ELEVATION
NUMBERS
JT4 T1410[Mr-101
WALL TYPE
EXTERIOR ELEVATIONS
BUILDING/WALL SECTION
WALL SECTION
uJ
-
EMERGENCY SWITCH
_
SWITCH
"}
3 - WAY SWITCH
_692'r
4 - SWITCH
OVERHEAD DOOR OPERATOR
OVERHEAD DOOR PUSH
BUTTON PILOT LIGHT
SMOKE DETECTOR AC/DC
C D
CARBON MONOXIDE
DETECTOR AC/DC
FLOOR MOUNTED
TELEPHONE JACK
®
FLOOR MOUNTED
DUPLEX OUTLET
PART - PARTIAL
P-CONSR - PLUMBING CONTRACTOR
PB -
PANEL BOX
PLUMB -
PLUMBING
PLYWOOD-
PLYWOOD
PNT -
PAINT
PREFAB -
PREFABRICATED
PSI -
POUNDS PER SQUARE INCH
P.T. -
PRESSURE TREATED
P.W. -
PICTURE WINDOW
R -
RISER/RADIUS
REINF -
REINFORCED
REQ'D -
REQUIRED
RO -
ROUGH OPENING
RM -
ROOM
S -
SINK
S.B.O. -
SELECTED BY OWNER
SCHED -
SCHEDULE
SO -
SMOKE DETECTOR
SECT -
SECTION
FOOT
SF -
SQQUARE
Sim -
SIMILAR
SQ FT -
SQUARE FEET
SS -
STAINLESS STEEL
STD -
STANDARD
STL -
STEEL
STOR -
STORAGE
STRUCT -
STRUCTURAL
T -
TREAD/701LET
TCP -
TEMPERATURE CONTROL PANEL
TEMP -
TEMPERED
T'STAT -
THERMOSTAT
TYP -
TYPICAL
UNFIN - UNFINISHED
V.I.F VERIFY IN FIELD
W/
- WITH
W.C.
- WATER CLOSET
WD
- WOOD
W.P.
- WATERPROOF
WTR
- WATER
W.W.F.
- WELDED WIRE FABRIC
W.W.M.
- WELDED WIRE MESH
PARTICLE BOARD
CONTINUOUS WOOD
FRAMING THROUGH
MEMBER.
r •�r
BATT INSULATION
NEW PARTITION
(INDICATES PARTITION TYPE)
REFERENCE POINT
INDICATES HIDDEN LINE -
ABOVE, BELOW, BEHIND OR
ITEMS TO BE REMOVED
CENTERLINE OR N.I.C.
EXISTING CONSTRUCTION
EXISTING CONSTRUCTION
TO BE REMOVED
NEW CONSTRUCTION
EQUIPMENT TYPE
(SEE SCHEDULE)
BEAM NUMBER
(SEE SCHEDULE)
CEILING MOUNTED
LIGHT
MOUNTED
HojWALL
'
LIGHT FIXTURE
WALL MOUNTED
LIGHT FIXTURE
CEILING FAN
WITH LIGHT
TELEPHONE JACK
SURFACE MOUNTED
BATHROOM OVERHEAD
CEILING HEATER
HANGING PENDANT
LIGHTING
LINEAR LIGHT
RECESSED LIGHT /T
EMERGENCY EXIT SIGN
Ky
L_I COMBINATION EGRESS &
L_I EMERGENCY LIGHTING
FIXTURE
SPRINKLER HEAD
2X4 FLUORESCENT LIGHT
2X2 FLUORESCENT LIGHT
1. ARCHITECT IS NOT CONTRACTED FOR SUPERVISION
AND IS NOT RESPONSIBLE FOR METHODS OF
CONSTRUCTION OR MATERIALS USED.
2. ALL SITE MEASUREMENTS SHALL BE VERIFIED AND
COORDINATED WITH ALL TRADES IN FIELD.
3. ALL FIXTURES, FURNITURE AND EQUIPMENT SHALL BE
SELECTED AND PROVIDED BY OWNER.
4. ALL CUSTOM MILLWORK AND CABINETRY SHALL
MEASURED AND FIELD VERIFIED, FINISH AND STYLE
SHALL BE SELECTED BY OWNER.
5. ALL WORK SHALL CONFORM TO THE REQUIREMENTS
OF THE STATE IN WHICH THE PROJECT RESIDES AND
INTERNATIONAL BUILDING CODE, FIRE DEPARTMENT
REGULATIONS, UTILITY COMPANY REQUIREMENTS,
AND THE BEST TRADE PRACTICES.
6. BEFORE COMMENCING WORK, THE CONTRACTOR
SHALL FILE ALL REQUIRED CERTIFICATES OF
INSURANCE WITH THE DEPARTMENT OF BUILDINGS,
OBTAIN ALL REQUIRED PERMITS, AND PAY ALL FEES
REQUIRED BY GOVERNING AGENCIES.
9. THE CONTRACTOR SHALL VERIFY ALL EXISTING
CONDITIONS IN THE FIELD PRIOR TO COMMENCING
WORK, AND SHALL REPORT ANY DISCREPANCIES
BETWEEN DRAWINGS AND FIELD CONDITIONS TO THE
ARCHITECT.
10. MINOR DETAILS NOT USUALLY SHOWN OR SPECIFIED,
BUT NECESSARY FOR PROPER CONSTRUCTION OF
ANY PART OF THE WORK SHALL BE INCLUDED AS IF
THEY WERE INDICATED IN THE DRAWINGS.
11. THE CONTRACTOR SHALL COORDINATE ALL WORK
PROCEDURES WITH REQUIREMENTS OF LOCAL
AUTHORITIES AND BUILDING MANAGEMENT.
12. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE
PROTECTION OF ALL CONDITIONS AND MATERIALS
WITHIN THE PROPOSED CONSTRUCTION AREA. THE
CONTRACTOR SHALL DESIGN AND INSTALL ADEQUATE
SHORING AND BRACING FOR ALL STRUCTURAL OR
REMOVAL TASKS. THE CONTRACTOR SHALL HAVE
SOLE RESPONSIBILITY FOR ANY DAMAGE OR INJURIES
CAUSED BY OR DURING THE EXECUTION OF THE
WORK.
13. THE CONTRACTOR SHALL LAY OUT HIS OWN WORK,
AND SHALL PROVIDE ALL DIMENSIONS REQUIRED FOR
OTHER TRADES (MECHANICAL, PLUMBING,
ELECTRICAL, ETC.).
14. MECHANICAL, PLUMBING AND ELECTRICAL WORK
SHALL BE PERFORMED BY PERSONS LICENSED IN
THEIR TRADES, WHO SHALL ARRANGE FOR AND
OBTAIN INSPECTIONS AND REQUIRED SIGN OFFS.
15. THE CONTRACTOR SHALL DO ALL CUTTING, PATCHING,
REPAIRING AS REQUIRED TO PERFORM ALL OF THE
WORK INDICATED ON THE DRAWINGS, AND ALL OTHER
WORK THAT MAY BE REQUIRED TO COMPLETE THE
JOB.
16. ALL PIPING AND WIRING SHALL BE REMOVED TO A
POINT OF CONCEALMENT AND SHALL BE PROPERLY
CAPPED OR PLUGGED.
17. THE CONTRACTOR, UPON COMPLETION OF THE WORK,
SHALL ARRANGE FOR DEPARTMENT OF BUILDINGS
INSPECTIONS AND SIGN -OFFS AS REQUIRED.
18. ALL WORK SHALL CONFORM TO ALL CODES HAVING
JURISDICTION, WHERE CONFLICTS OF/OR BETWEEN
CODES OCCUR, THE MORE STRINGENT CODE SHALL
SUPERSEDE ALL OTHERS.
19. USE ONLY NEW MATERIALS WITHOUT DEFECTS.
20. EACH CONTRACTOR AND/OR SUB -CONTRACTOR
SHALL COORDINATE HIS OWN WORK WITH OTHER
TRADES.
21. DISCREPANCIES AND OMISSIONS ON DRAWINGS AND
SPECIFICATIONS SHALL BE REPORTED TO THE
ARCHITECT OR ENGINEER IN WRITING FOR
CLARIFICATION.
22. ALL CONTRACTORS AND/OR SUB -CONTRACTORS ARE
TO USE THE APPROVED STANDARDS: A.I.S.C.,
FEDERAL, U.S., ETC., AND THE HIGHEST STANDARDS
OF THEIR TRADES. ALL CONSTRUCTION SHALL BE
PERFORMED TO THESE STANDARDS.
23. SET ALL WORK STRAIGHT, PLUMB, AND LEVEL OR
WITH INDICATED SLOPE.
24. THE CONTRACTOR SHALL KEEP THE PREMISES FREE
FROM ACCUMULATION OF WASTE MATERIAL AND
RUBBISH. AT THE COMPLETION OF WORK, HE SHALL
REMOVE FROM THE PREMISES ALL RUBBISH,
IMPLEMENTS AND SURPLUS MATERIALS; AND LEAVE
THE JOB IN A "BROOM CLEAN" CONDITION
25. NO WORK TO COMMENCE UNTIL APPROVAL IS
OBTAINED FROM LOCAL BUILDING AND DEPT. OF
PLANNING AND ZONING; AND ALL NECESSARY
PERMITS HAVE BEEN SECURED.
26. THE ARCHITECT OR ENGINEER ARE TO BE NOTIFIED A
MINIMUM OF FORTY-EIGHT (48) HOURS PRIOR TO ANY
INSPECTIONS.
27. ALL PROPERTY AND SURFACES DAMAGED DURING
CONSTRUCTION BY THE CONTRACTOR OR
SUB -CONTRACTORS OR THEIR WORK FORCE SHALL
BE REPAIRED TO MATCH THE SURROUNDING
SURFACES OR ORIGINAL CONDITIONS TO THE
SATISFACTION OF THE OWNER AND ARCHITECT OR
ENGINEER.
28. ANY DEVIATION FROM THESE PLANS SHALL CAUSE
THE WORK TO CEASE IN THE AFFECTED AREA UNTIL
THE CHANGE HAS BEEN APPROVED BY THE
ARCHITECT OR ENGINEER.
29. THESE DRAWINGS AND SPECIFICATIONS ARE VALID
ONLY IF THEY BEAR THE IMPRESSED SEAL AND
ORIGINAL SIGNATURE OF THE ARCHITECT OR
ENGINEER WHOSE NAME APPEARS HEREON.
30. ANY UNAUTHORIZED ALTERATION OF OR ADDITION TO
THESE DRAWINGS IS A VIOLATION TO THE
ARCHITECTS CONTRACT AND SHALL BE NOTIFIED
ONLY IN WRITING, SIGNED AND SEALED BY THE
ARCHITECT OR ENGINEER.
31. ALL PREPARATION AND PAINTING WORK SHALL BE OF
FIRST QUALITY WORKMANSHIP AND ONLY SKILLED
MECHANICS WILL BE EMPLOYED.
32. ALL GLASS IN EXTERIOR WALLS SHALL BE INSULATED
GLASS (DOUBLE GLAZED).
33. ALL DOORS AND WINDOWS IN EXTERIOR WALLS SHALL
BE WEATHER-STRIPPED.
34. ALL CONCRETE TO BE MINIMUM OF 3,000 P.S.I.
(CONCRETE COMPRESSIVE STRENGTH AT 28 DAYS).
35. ARCHITECT CERTIFIES THAT TO THE BEST OF HIS
KNOWLEDGE AND BELIEF, DRAWINGS AND
SPECIFICATIONS COMPLY WITH ALL LOCAL CODES.
36. ARCHITECT SHALL NOT BE RESPONSIBLE FOR THE
SUPERVISION AND/OR INSPECTION OF
CONSTRUCTION OR THE SAFETY OF THE
CONSTRUCTION SITE. THE ARCHITECT OR HIS AGENTS
SHALL BE ALLOWED FREE ACCESS TO THE
CONSTRUCTION SITE AND/OR PROJECT.
37. ALL ORIGINAL CONSTRUCTION DOCUMENTS,
PHOTOGRAPHS, SKETCHES AND ESTIMATES SHALL
REMAIN THE PROPERTY OF THE ARCHITECT AND
SHALL BE CONSIDERED AS INSTRUMENTS OF THE
SERVICES RENDERED WHETHER THEY WERE
EXECUTED OR NOT.
38. ANY MODIFICATION OR REPRODUCTION OF. THESE
PLANS OR SPECIFICATIONS FOR USES OTHER THAN
THE INTENDED PROJECT IS STRICTLY FORBIDDEN
WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE
ARCHITECT.
39. CONTRACTORS SHALL BE RESPONSIBLE FOR
ADEQUATELY BRACING AND PROTECTING ALL WORK
DURING CONSTRUCTION AGAINST DAMAGE
BREAKAGE, COLLAPSE, DISTORTIONS, AND
MISALIGNMENTS ACCORDING TO APPLICABLE CODES,
STANDARDS AND GOOD PRACTICE.
40. ALL TILE ON BATHROOM WALLS SHALL BE INSTALLED
OVER 1/2" CEMENT BOARD (WONDER BOARD) AND ALL
OTHER WALL SURFACES SHALL HAVE 1/2" (GREEN
BOARD) WATER RESISTANT GYPSUM BOARD.
41. ALL STRUCTURAL LUMBER SHALL BE DOUGLAS FIR
GRADE #2 OR BETTER AND HAVE A MINIMUM OF F'B
1200 PSI,
42. ALL JOISTS SHALL BE DOUBLED UNDER ALL PARALLEL
WALLS ABOVE AND BLOCKED SOLID UNDER ALL
WALLS PERPENDICULAR TO THE JOISTS.BRIDGING
SHALL BE INSTALLED ON ALL JOIST SPANS EXCEEDING
10'-0" AT MID -SPAN AND AT 3RD POINTS OF SPANS
EXCEEDING 17'-0". BRIDGING SHALL BE INSTALLED.
43. ALL WOOD MATERIALS AND FLOOR SYSTEMS PLACED
CONCRETE SLABS ON GRADE OR CONCRETE PIERS
SHALL BE CONSTRUCTED WITH PRESSURE TREATED
LUMBER IN ACCORDANCE WITH ATIC, AND SHALL BE
CAULKED AT THE SLAB TO PREVENT AIR
PENETRATION.
44. ALL FOOTINGS SHALL BEAR ON VIRGIN, UNDISTURBED
SOIL WITH A MINIMUM BEARING CAPACITY OF 1.5 TONS
PSF. WHERE FOOTING BEAR ON ROCK FOOTINGS
SHALL BE LEVEL AND 1/2" DIAMETER STEEL DOWELS
INSERTED INTO THE ROCK 24" ON CENTER, 8" DEEP
UNLESS SPECIFIED OTHERWISE AND SECURED WITH
NON -SHRINKING GROUT.
45. THE BOTTOM OF ALL FOOTINGS TO BE A MINIMUM OF
T-6" BELOW FINISHED GRADE UNLESS NOTED
OTHERWISE. IF STEP FOOTINGS ARE REQUIRED,
STEPS SHOULD NOT EXCEED 16" RISE PER 48" RUN.
46. SLOPE ALL GRADES AWAY FROM THE BUILDING. 1/4":
12" MINIMUM PITCH FDR GRASS AREAS AND 1 /8": 12"
MINIMUM PITCH FOR SMOOTH FINISHED PAVED
AREAS. HANDICAP ACCESSIBLE GRADES SHALL NOT
EXCEED 1 ": 12" PITCH.
47. ALL METAL CONNECTORS, PLATES, NAILS, BOLTS,
SCREWS, ETC. SPECIFIED FOR CONSTRUCTION SHALL
BE INSTALLED PER MANUFACTURER'S
SPECIFICATIONS, NOSUBSTITUTION IS PERMITTED
WITHOUT EXPRESS WRITTEN AUTHORIZATION BY
ARCHITECT.
48. ALL COMPOSITE WOOD PRODUCTS, LE: WOOD
i-BEAMS, MICROLAMS, PARALLAMS, GLU-LAMS AND/OR
STRESS SKIN INSULATED PANELS SHALL BE
INSTALLED PER MANUFACTURER'S SPECIFICATIONS.
NO SUBSTITUTION IS PERMITTED WITHOUT EXPRESS
WRITTEN AUTHORIZATION BY ARCHITECT. DO NOT
LEAVE THE ABOVE WOOD PRODUCTS OUTSIDE
-UNPROTECTED FROM THE ELEMENTS.
49. ANY CONTRACTOR INSTALLING CONSTRUCTION
MATERIAL NOT IN ACCORDANCE WITH MATERIAL
MANUFACTURER'S SPECIFICATIONS, COMMON TRADE
PRACTICES OR IN ACCORDANCE WITH ARCHITECTS
CONSTRUCTION DOCUMENTS SHALL BE RESPONSIBLE
FOR REMOVAL OF INCORRECTLY INSTALLED
MATERIAL AND CORRECT RE -INSTALLATION AT THEIR
COST UNLESS AGREED TO OTHERWISE BY OWNER
AND ARCHITECT.
50. BOILER SHALL HAVE A LOW WATER SHUT OFF VALVE.
51. KITCHEN RANGE HOCD MUST HAVE A BACK DRAFT
DAMPER.
52. FLASHING SHALL BE CORROSIVE -RESISTIVE AND
LOCATED AT THE TOP OF ALL EXTERIOR WINDOWS
AND DOORS AND INTERSECTION OF CHIMNEY.
53. EXTERIOR PARTITIONS ARE TYPICALLY 2X6'S AT 16"ON
CENTER, UNLESS NOTE OTHERWISE.
54. HEADER SCHEDULE:
INTERIOR (2) 2X10'S (UP TO 4'-0" OPENINGS).
EXTERIOR (3) 2X10'S (UP TO V-0" OPENINGS).
55. PLYWOOD SHEATHING FOR EXTERIOR WALLS AND
ROOF SHALL BE CDX EXPOSURE #1 WITH EXTERIOR
GLUE AS GRADED BYAMERICAN PLYWOOD
ASSOCIATION (APA). PLYWOOD THICKNESS TO BE AS
SHOWN ON THE DRAWINGS.
56. FLOOR SHEATHING SHALL BE 3/4" TONGUE AND
GROOVE, "STURD-L-FLOOR" EXPOSURE #1 PLYWOOD
AS GRADED BY APA. ALL FLOORS PLYWOOD TO BE
GLUED AND NAILED AS PER MANUFACTURER
INSTRUCTIONS. EXCEPT, AT AREAS TO RECEIVE
CERAMIC TILE, GLUE AND SCREW T&G PLYWOOD
SUB -FLOOR.
57. LATERAL BRACING: AT FLOOR FRAMING PROVIDE 1X3
CROSS -BRACING OR SOLID BLOCKING AT MID SPAN OF
JOISTS UP TO 15'-0", AT ONE-THIRD POINTS (2 ROWS)
AT JOIST SPANS OF GREATER THAN 16-0".
58. PROVIDE DOUBLE JOISTS BELOW ALL PARALLEL
PARTITIONS.
59. PROVIDE 1 ROW OF SOLID BLOCKING (STAGGERED
AND END NAILED) AT MID SPAN OF ALL PARTITIONS
9'-0" IN HEIGHT OR GREATER.
60. PROVIDE SOLID BLOCKING FOR FIRE -STOPPING AT
FLOOR LINES.
61. PROVIDE SOLID BLOCKING BELOW ALL BEAMS AND
HEADERS.
62. EXTERIOR LUMBER: ALL EXTERIOR CONSTRUCTIONS,
INCLUDING DECKS, SHALL UTILIZE "PRESSURE
TREATED" LUMBER.
63. ALL JOIST HANGERS, HURRICANE CLIPS AND OTHER
CONNECTORS TO BE MINIMUM 18 GAUGE, ZINC
COATED STEEL, SIZED AS REQUIRED FOR MEMBER
CONNECTED.
64. ALL NAILING SHALL CONFORM TO RECOMMENDED
NAILING SCHEDULE OF CONNECTICUT STATE
BUILDING CODE OR OTHER CONTROLLING
JURISDICTION.
65. FRAMER IS TO PROVIDE SOLID WOOD TRIPLE 2X6
POSTS UNDER ALL WOOD BEAMS. POSTS ARE TO
BEAR ON SOUND WOOD BLOCKING FOR DIRECT LOAD
TO TRANSFER TO FOUNDATION.
66. INSTALL SKEWED METAL HANGERS AT ALL ANGLED
BEAM CONNECTIONS. INSTALL METAL HIP/RIDGE
CONNECTORS AT ALL RIDGE AND HIP JUNCTIONS. USE
SIMPSON HANGERS OR EQUAL.
67. INSTALLATION OF ALL DOORS, WINDOWS, AND ALL
OTHER BUILDING COMPONENTS IS TO BE IN
ACCORDANCE WITH THE MANUFACTURER'S
SPECIFICATION.
68, SITE ENGINEERING AND ALL MECHANICAL
PLUMBING,ELETRICAL ENGINEERING ARE NOT
INCLUDED IN THE PLANNING OF THESE DRAWINGS.
69. KITCHEN LAYOUT SHOWN ON THE DRAWINGS IS
SCHEMATIC ONLY. FINAL APPLIANCE LOCATIONS AS
AND CABINET SIZES / CONFIGURATIONS ARE TO BE
APPROVED BY THE OWNER AND PROVIDED BY
KITCHEN MANUFACTURER.
70. PROVIDE ONE (1) LAYER OF 5/8-FIRE RATED GYPSUM
BOARD AT ALL GARAGE DEMISING PARTITIONS,
CEILINGS AND BEAMS.
71. INSULATION: PROVIDE FIBERGLASS BATT INSULATION
WITH INTEGRAL VAPOR BARRIER, INSTALLED AS PER
MANUFACTURERS INSTRUCTIONS TO BE FOLLOWING
LEVELS (UNLESS OTHERWISE INDICATED ON THE
DRAWINGS):
CONNECTICUT
EXTERIOR WALLS: R-20 OR 13+5
TOP FLOOR CEILING: R-38
BASEMENT CEILING: R-30
CATHEDRAL CEILINGS: (AS PER DRAWINGS)
NEW YORK
EXTERIOR WALLS: R-19
TOP FLOOR CEILING: R-38
BASEMENT CEILING: R-30
CATHEDRAL CEILINGS: (AS PER DRAWINGS)
DEMOLITION NOTES
1. CONTRACTOR SHALL PERFORM ALL OPERATIONS OF
DEMOLITION AND REMOVAL INDICATED ON THE
DRAWINGS. ALL WORK SHALL BE DONE CAREFULLY
AND CARRIED OUT IN A SYSTEMATIC MANNER.
2. ALL EXISTING SURFACES AND EQUIPMENT TO REMAIN
SHALL BE FULLY PROTECTED FROM DAMAGE. THE
CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY
FOR DAMAGE AND SHALL MAKE REPAIRS REQUIRED
WITHOUT ADDITIONAL COST TO THE OWNER.
3. NO DEBRIS SHALL BE ALLOWED TO ACCUMULATE ON
THE SITE. THE CONTRACTOR SHALL REMOVE DEBRIS
AS THE JOB PROCEEDS. THE SITE SHALL BE LEFT
BROOM CLEAN AT THE COMPLETION OF DEMOLITION.
4. NO STRUCTURAL ELEMENTS SHALL BE REMOVED
UNLESS EITHER TEMPORARY SHORING OR NEW
STRUCTURAL ELEMENTS AS REQUIRED TO PROTECT
THE STABILITY AND INTEGRITY OF THE EXISTING
STRUCTURE ADEQUATELY SUPPORT PORTIONS
AFFECTED.
5. CONTRACTORS SHALL PROVIDE, ERECT, BRACE,
SHORE, UNDERPIN, AND MAKE SAFE ALL WALLS,
FLOORS, SIDEWALKS, FOOTINGS, FOUNDATIONS, AND
ADJACENT PROPERTIES, AS THE JOB CONDITIONS
REQUIRE AND AS REQUIRED BY DEPARTMENT OF
BUILDINGS RULES AND REGULATIONS
6. BEFORE REMOVING DEBRIS OR PORTIONS THEREOF,
CONTRACTOR SHALL DETERMINE THAT SUCH ARE
NOT LOAD-BEARNING. IF PLANS CALL FOR REMOVAL
OF ANY PARTS THAT ARE LOAD -BEARING, THE
ARCHITECT OR ENGINEER IS TO BE IMMEDIATELY
CONSULTED.
7. REMOVE OR RELOCATE ALL WIRING, PLUMBING, AND
MECHANICAL EQUIPMENT AFFECTED BY REMOVAL OF
PARTITIONS. REMOVED PIPES AND/ OR LINES SHALL
BE CUT TO A POINT OF CONCEALMENT BEHIND OR
BELOW FINISH SURFACES, AND SHALL BE PROPERLY
CAPPED OR PLUGGED.
8. THE CONTRACTOR SHALL PROVIDE ADEQUATE
WEATHER PROTECTION FOR THE BUILDING AND ITS
CONTENTS DURING THE COURSE OF THE WORK. ALL
OPENINGS IN ANY WALL OR ROOF SHALL BE
PROTECTED FROM ALL FORMS OF WEATHER OR
WATER PENETRATION.
STRUCTURAL NOTES
1. ALL STRUCTURE SHALL BE VERIFIED AND SIZED BY
LICENSED STRUCTURAL ENGINEER. ALL INSPECTIONS
SHALL BE PERFORMED BY PERSONS LICENSED IN
THEIR TRADE WHO SHALL ARRANGE FOR AND OBTAIN
INSPECTIONS AND REQUIRED SIGN OFFS.
MECHANICAL NOTES
1. ALL NEW WORK SHALL BE DESIGNED AND
COORDINATED BY OTHERS.
2. ALL EXISTING MECHANICAL SYSTEMS SHALL BE SITE
VERIFIED. ALL NEW SYSTEMS SHALL BE SIZED AND
DESIGNED BY LICENSED ENGINEER. ALL INSPECTIONS
SHALL BE PERFORMED BY PERSONS LICENSED IN
THEIR TRADE WHO SHALL ARRANGE FOR AND OBTAIN
INSPECTIONS AND REQUIRED SIGN OFFS.
ELECTRICAL NOTES
1. ALL NEW WORK SHALL BE DESIGNED AND
COORDINATED BY OTHERS.
2. ALL ELECTRICAL NOTES SHALL BE PERFORMED BY A
LICENSED ELECTRICIAN.
3. ALL WORK SHALL CONFORM TO ALL CODES AND
REQUIREMENTS OF AUTHORITIES HAVING
JURISDICTION.
4. CONTRACTOR IS RESPONSIBLE FOR PROCUREMENT
OF ALL INSPECTION CERTIFICATES.
5. ALL SMOKE, HEAT AND CARBON MONOXIDE
DETECTORS SHALL BE HARDWIRED AND
INTERCONNECTED WITH BATTERY BACK-UP.
PLUMBING AND DRAINAGE NOTES
1. ALL NEW WORK SHALL BE DESIGNED AND
COORDINATED BY OTHERS.
2. PLUMBING CONTRACTOR TO EXAMINE PROPOSED
LAYOUT WITH REGARD TO EXISTING FIELD
CONDITIONS, AND SHALL NOTIFY ARCHITECT OF ANY
DISCREPANCIES BETWEEN ASSUMED FIELD
CONDITIONS AND THOSE ENCOUNTERED DURING
CONSTRUCTION.
3. PLUMBING CONTRACTOR SHALL INFORM ARCHITECT
OF ANY REVISIONS TO PLAN SHALL BE NECESSARY,
BASED ON CONDITIONS UNCOVERED IN THE FIELD, IN
ORDER TO INSTALL ALL FIXTURES, EQUIPMENT AND
PIPING IN STRICT ACCORDANCE WITH REQUIREMENTS
OF THE NYC BUILDING CODE.
4. PLUMBING CONTRACTOR SHALL ARRANGE AND
OBTAIN INSPECTIONS AND REQUIRED SIGN -OFFS.
5. REMOVE OR RELOCATE ALL PLUMBING AFFECTED BY
REMOVAL OF PARTITIONS. REMOVED PIPES SHALL BE
CUT TO A POINT OF CONCEALMENT BEHIND OR
BELOW FINISH SURFACES AND SHALL BE PROPERLY
CAPPED OR PLUGGED.
6. ALL CONCEALED PLUMBING SHALL BE REPLACED
WITH NEW. PROVIDE ACCESSIBLE ISOLATION VALVES
IF NONE ARE PRESENT.
NOTE: THIS PLAN IS APPROVED ONLY FOR WORK
APPROVED ON THE APPLICATION SPECIFICATION
SHEET. ALL OTHER MATTERS SHOWN ARE NOT TO BE
RELIED UPON, OR TO BE CONSIDERED AS EITHER
APPROVED OR IN ACCORDANCE WITH APPLICATION
CODES.
SMOKE DETECTING DEVICES
1. DWELLING UNITS SHALL BE EQUIPPED WITH SMOKE
DETECTING DEVICES, HARDWIRED WITH BATTERY
BACK-UP.
2. SMOKE ALARMS OR DETECTORS SHALL BE LOCATED
WITHIN DWELLING UNITS AS FOLLOWS:
A. ON THE CEILING OR WALL OUTSIDE OF EACH ROOM
USED FOR SLEEPING PURPOSES WITHIN 15 FEET
B. IN EACH ROOM USED FOR SLEEPING PURPOSES.
C. IN EACH STORY WITHIN A DWELLING UNIT,
INCLUDING BELOW -GRADE STORIES, FINISHED
ATTICS AND PENTHOUSES OF ANY AREA, BUT
NOT INCLUDING CRAWL SPACES AND
UNINHABITABLE ATTICS. IN DWELLINGS OR
DWELLING UNITS WITH SPLIT LEVELS AND WITHOUT
AN INTERVENING DOOR BETWEEN THE ADJACENT
LEVELS. A SMOKE ALARM INSTALLED ON THE UPPER
LEVEL SHALL SUFFICE FOR THE ADJACENT LOWER
LEVEL PROVIDED THAT THE LOWER LEVEL IS
LESS THAN ONE FULL STORY BELOW THE UPPER
LEVEL.
CARBON MONOXIDE DETECTOR NOTES
1. CARBON MONOXIDE DETECTION DEVICES SHALL
CONFORM TO STATE BUILDING CODE.
2. CARBON MONOXIDE DETECTION DEVICES SHALL
RECEIVE THEIR PRIMARY POWER FROM BUILDING
WIRING. THERE SHALL BE NO SWITCHES IN THE
CIRCUIT OTHER THAN THE OVER CURRENT DEVICE
PROTECTING THE BRANCH CIRCUIT.
3. CARBON MONOXIDE ALARMS OR DETECTORS SHALL
BE LOCATED WITHIN DWELLING UNITS AS FOLLOWS:
A. OUTSIDE OF ANY ROOM USED FOR SLEEPING
PURPOSES, WITHIN 15 FEET (4572 MM) OF THE
ENTRANCE TO SUCH ROOM.
B. IN ANY ROOM USED FOR SLEEPING PURPOSES.
C. ON ANY STORY WITHIN A DWELLING UNIT, INCLUDING
BELOW -GRADE STORIES, FINISHED ATTICS AND
PENTHOUSES OF ANY AREA, NOT INCLUDING CRAWL
SPACES AND UNINHABITABLE ATTICS.
ALL CARBON MONOXIDE DETECTION DEVICES SHALL
BE ACCEPTED PURSUANT TO RULES AND
REGULATIONS PROMULGATED BY THE
COMMISSIONER, APPROVED BY THE BOARD OF
STANDARDS AND APPEALS OR LISTED BY A
NATIONALLY RECOGNIZED INDEPENDENT
LABORATORY. NO DEVICE SHALL BE DEEMED TO BE IN
COMPLIANCE WITH THIS PROVISION UNLESS IT IS OF
EITHER THE IONIZATION OR PHOTO -ELECTRIC TYPE.
GENERAL CONCRETE AND MASONRY NOTES
1. CONCRETE DIMENSIONS ARE TYPICALLY TO FACE OF
WALL.
2. ALL CONCRETE SLABS SHALL MINIMUM 4" THICK, WITH
6X6-10X10-W1,4XW1.4 WELDED WIRE FABRIC, PLACED
OVER 6 MIL POLYETHYLENE VAPOR BARRIER OVER A
MINIMUM 6" BED OF COMPACTED GRAVEL.
3. PROVIDE 1/2" THICK EXPANSION JOINT MATERIAL AT
PERIMETER WHERE SLABS ABUTS OTHER CONCRETE
OR MASONRY MATERIAL.
4. ALL STEEL REINFORCING INDICATED ON THESE
DRAWINGS SHALL CONFORM TO ASTM A615. GRADE
60, SIZES AS SHOWN IN THE DRAWINGS. WELDED
WIRE FABRIC SHALL CONFORM TO ASTM 185. SEE
DRAWINGS FOR LOCATIONS OF REINFORCEMENT.
5. PROVIDE ANCHOR BOLTS, SIZES AS INDICATED ON
THESE DRAWINGS, AT TOP OF CONCRETE
FOUNDATION WALLS AT MINIMUM 1'-0" FROM
CONCERNS AND MAXIMUM 4'-0" O.C. FOR BALANCE OF
PERIMETER WALLS, TWO PER PLATE MINIMUM.
6. REMOVE ALL WATER FROM EXCAVATION PRIOR TO
CONCRETE PLACEMENT.
7, ALL CONCRETE FOOTINGS SHALL BEAR ON
UNDISTURBED VIRGIN SOIL WITH PRESUMPTIVE
BEARING CAPACITY 4,000 PSF, OR ON ENGINEERED
STRUCTURAL FILL WITH THE SAME TESTED CAPACITY.
8. STEP CONCRETE FOOTINGS AT ELEVATION CHANGES
AT MAXIMUM RATIO OF ONE VERTICAL UNIT TO TWO
HORIZONTAL UNITS.
9. AT CONCRETE FROST WALLS, BOTTOM OF FOOTING
TO BE SET AT MINIMUM T-6" DISTANCE BELOW FINISH
GRADE.
10. FOR TYPICAL CONCRETE FOUNDATION WA-L, FROST
ALL IN FOOTING SIZES, REFER TO DRAWINGS.
11. IF CONCRETE IS TO BE POURED IN COLD WEATHER
CONDITIONS, THE CONTRACTOR IS RESPONSIBLE TO
IMPLEMENT ADEQUATE CONCRETE PROTECTION
PROCEDURES.
12. CONCRETE FOUNDATION WALL THAT EXCEED 8'-0" IN
HEIGHT MUST BE REINFORCED WITH STEEL DESIGNED
BY A LICENSED STRUCTURAL ENGINEER.
13. ALL CONCRETE SHALL HAVE MINIMUM 28 DAYS
STRENGTHS AS FOLLOWS:
GARAGE SLABS 3,500 PSF
BASEMENT SLABS 3,000 PSF
CRAWL SPACE SLABS 3,000 PSF
EXTERIOR SLABS 3,000 PSF
FOUNDATION WALLS 3,000 PSF
14. FOUNDATION BACKFiLL SHALL NOT TAKE PLACE UNTIL
FIRST FLOOR DECK FRAMING IS COMPLETE AND
FLOOR SHEATHING IS INSTALLED.
15, FIREPLACE AND FLUE SIZES SHOWN ARE SCHEMATIC,
CONTRACTOR SHALL SEE TO THE PROVISIONS OF THE
PROPERLY BUILT AND FUNCTIONING UNIT WITH ALL
NECESSARY COMPONENTS, ALL FIREPLACES SHALL
HAVE FRESH AIR INTAKES. VERIFY EXISTING IN FIELD.
16. MASON AND HVAC CONTRACTOR ARE TO VERIFY FLUE
SIZES CONSTRUCTING THE CHIMNEY.
THERMAL & MOISTURE PROTECTION NOTES
1. ALL WINDOWS AND DOORS TO BE
WEATHER-STRIPPED AND CAULKED.
2. ALL SEALANTS TO BE SILICONE, COLORED TO MATCH
SURROUNDING MATERIAL.
3. ALL FLASHING SHALL BE NONFERROUS METAL
(UNLESS OTHERWISE NOTED).
Document History
Rev# Date Purpose
11.25.19 ISSUED FOR BUILDING
PERMIT
arch itecture+deign
ARCHITECT:
EMILIA FERRI ARCHITECTURE + DESIGN
42 N. MAIN STREET, 2ND FLOOR
PORT CHESTER, NY 10573
c: 203.545.7761
o: 914.305.6210
f: 203.813.3860
emilia@emiliaferridesign.com
Certificate of Authorization
Signature and Seal
Professional License Number
CT: 0011978 NY:033560
Project:
233 TREE TOP CRESCENT
RYE BROOK, 10573
NTS I EF I 2019.019
G=1 mO
0 Emilia Ferri Architecture + Design, LLC All Rights Reserved.
Document History
Rev# Date Purpose
11.25.19 ISSUED FOR BUILDING
TABLE R547.2.1 PLACEMENT OF LAG SCREWS AND BOLTS IN DECK LEDGERS AND BAND GISTS
MINIMUM ENE? AND EDGE DISTANCES AND SPACING BETWEEN ROWS
TOP EDGE
BOTTOM EDGE
ENDS
ROW SPACii+lta
Ledgeia
2 inchesd
314, inch
2 inchesb
1518 inches'
Sand jolstc
3t4 inch
2 inches
2 inch =sb
151S inchesb
For Sl:1 inch = 25.4 tram.
a. Lag screws or bolts shall be staggered from the top to the bottom along the horizontal run of the
deck ledger in accordance with Figure R507.2.1(1).
b, Maximum 5 inches.
c. Forengineered rim joists, the manufacturer's recommendations shall govern.
d. The mininiurn distance from bottom raw of lag screws or bolts to the top edge of the ledger shall be
in accordance with Figure R507.21(1).
STAGGER FASTENERS
_ IN 2ROWS
6:5" MIN. FOR 2 X s' *01STANCE SHALL BE PERWITrED TO
6.5"MIN.IFOR2X10 BE REDUCED TO4-'IFLAG SCREM
7, * MIN. FOR 2X 12 ARE USED oft SOLT SPACING IS
REOLM-0 TO THAT OF LAG WREWS
TOATTACH 2 X 8 LEDGERS To 2 X s
BAND "STS.
LAG SCREW OR SOLI 314" MHN.
For SI: 1 inch = 25.4 mm.
SCALE: NTS
1E
�STIINIG LADE
EXI IN N// /// /// /• / !// �%/
/C,L tJTVALV,��
Bf�6R/11L'N
CN,,V/I.Fl�/
6XISTINt'M'ASONRY/
/SERVIdE'PiT /// /// / / /�/// /// //
EkISTIKG'
//W61'6>=CK'6/
/T/P
— — — — — — — — — — — — — — — — — —
t16'-4 112"
IREMOVE ALL
EXISTING TOP DECKING,
& STRUCTURE ASSEMBLY
co
EXISTING STEP DOWN, TO GRADE
VARIES t 9"-10", V.I.F.
EXISTING / DEMOLITION DECK PLAN
SCALE: 1 /4" =1'-0"
EXISTING STEP DOWN, TO GRADE
VARIES t 8%10", V.I.F.
EXISTING HAND RAIL &
GATE TO BE REMOVED
DECKING MATERIAL
CHOSEN BY OWNER
INE OF 2X8 PRESSUR-E
XISTING �REATED JOISTS
!OUSE
GALVANIZED
METAL BASE-
-
MAINTAIN
OVERHANG, V.I.F.
METAL JOIST
HANGERS
CAP W/ HORIZONTAL
DECK BOARD
TOTAL LENGTH OF
EXPOSED SIDES.
8�" ANCHOR BOLT
V.I.F. EXISTING GRADE VARIER
GRAVEL BED OVER 6-MIL
° 4 e °
POLY VAPOR BARRIER
2"X8" LEDGER BOARD,
` ..
(RECOMMENDEQ
SECURED TO EXISTING BOX
'<
OVER SUITABLE SOL
BEAM WITH" LAG BOLTS
�.. 4 -•:
16" O.C. STAGGERED AND
'
10"I?i SON-0-TUBE CONCRETE
DOUBLED. START 2"-5"
FILLED PIER, FLARE BOTTOM.
FROM EACH END. PROVIDE
. • •a
AND 3'-6" DEEP (TYP)
FLASHING AS REO'D.
�
TYPICAL SECTION
SCALE: 1/2" = V-0"
SCALE: 1 /4" =1'-0"
PROVIDE 2X FRAME
SUPPORT AND
t ACCESS PANEL ON
EXISTING MASONRY
WELL TO SERVICE
>
2"X8' PT LEDGER BOARD,
(D
MAIN SEWER PIPE
c4
SECURED TO EXISTING
W
BELOW. VERIFY
BOX BEAM WITH �' LAG
Z
FRAME SIZE IN
0)
BOLTS 16" O.C. STAGGERED
FIELD. PANEL TO BE
AND DOUBLED. START 2"-5"
SAME DECKING
FROM EACH END. PROVIDE
MATERIAL
FLASHING AS REQ'D.
- —, (2) 2X8 PT JOISTS
0
l✓
0cJLu"X
Z W
C=Q
40
W H z
N
cot
h
+i
2 2X8 PT JOISTS
8'-2 1/2" TYP. . 7r —
-- t 19'-5" V.I.F
V-6"
TYP.
SCALE: 1/4" =1'-0"
8'-21/2" TYP.
+1
No
10" O SON-0-TUBE CONC.
FILLED PIER, FLARE BOTTOM.
FLUSH WITH GRADE
AND 3`-6" DEEP (TYP.)
NOTE:
1. VERIFY ALL CONDITIONS IN FIELD.
NEW CONSTRUCTION
EXISTING CONSTRUCTION
C _ DEMOLITION
ARCHITECT:
EMILIA FERRI ARCHITECTURE + DESIGN
42 N. MAIN STREET, 2ND FLOOR
PORT CHESTER, NY 10573
c: 203.545.7761
o: 914.305.6210
f: 203.813.3860
emilia@emiliaferridesign.com
Signature and Seal
Professional License Number
CT: 0011978 NY:033560
Project:
233 TREE TOP CRESCENT
RYE BROOK, 10573
Sheet Title
EXISTING / DEMOLITION
PLAN,
PROPOSED DECK PLAN,
FRAMING PLAN &
TYPICAL SECTION.
scaie Project No.
AS NOTED I JP wn 1 2019.019 1
0 Emilia Ferri Architecture + Design, LLG All Rights Reserved.