HomeMy WebLinkAboutBP20-054PERMIT# CAU UvJ t DATE.-J,2 l_TL [LUP:�lu,_ /To
SECTION BLOCK LOT
TYPEOFWORK 1. y�L�v •J OTHER APPROVALS
JOB LOCAT'I/ON
ARB
OWNER �t/J.YLC//1 1<a �sh�r✓� KGr� 3�-7��a BOT
PB
CONTRACTOR ZBA
EST. COSTnn �O 5 FEE OTHER
✓CO # IXQ - I D FEE410Q ®D DATE
TCO # FEE DATE
w
NOTAS A 0R
DATE INSP
-- --
FOOTING
FOUNDATION
FRAMING
RGH FRAMING
INSULATION �-y ,�
PLUMBING I1� y-+"�
RGH PLUMBING ---
GAS
SPRINKLER _/ j5 O ao
ELECTRIC
ALARM O
AS BUILT
FINAL
ppao-osi/S+eacJy rlo) pjl+m%Ing
6pao,00751 ..{ecca 0"4"nc oG' Rye.
Existing Emergency Exit
Window & Scapewell
Window Well -
1
A-1
Andersen CW136 /
2'-4 7/8" x 3'-4 13/16"
High
I
-2"
Existing 30
Gallon Water
Heater, 75,000
BTUH
New Fan -in -a -Can
with 4" Fresh Air
Metal Flue
Existing
Furnace
113,000 BTUH
Existing
Chimney
Bathroom to be Legalized Bathroom to be Legalized
See 1/2" Scale Plan For Ceiling See 1/2" Scale Plan For Ceiling
Heights T Heights
Existing Existing Emergency Exit
12%
Fan to Window & Scapewell
2
S 4r Outside Window Well
/Existing
Existing
House =EM::�
0 Family Room 0
T-3 1/2" Ceiling 0� Trap
r LED
Exist ng
Fami y Rooin LF
7-3 1/2" Ceiling
ashen
CO
Dryer Existing LED
Storage
Existing T-6" Ceiling
Storage I Existing
T-6" Ceiling Laundry
Room
Existing 6'-9" Ceiling
Mitsubishi Unit soffit @ Existing 30
provides ducted, Gallon WaterHeater, 75,000
fj
heating and 011
cooling BTUH
New Fan -in -a -Can
Existing with 4" Fresh Air Existinc,
Family Room Metal Flue gamily Roorr
7'-3 1/2" Ceiling m 7'-3 1/2" Ceil
X- Existing
Furnace
113,000 BTUH
4" co
Existing
Chimney LEO
Existing Existing
Storage i 1Storage
T-6" Ceiling I I 7'-6" Ceil i n
7 rsl
BASEMENT CONSTRUCTION PLAN BASEMENT LIGHTING PLAN
SCALE: 1/4"=V-011 SCALE: 1/4"=V-011
6-6" Ceiling @ Water Closet Under Duct
6-8" Ceiling @ Shower
T-7 1/2" Ceiling in Front of Sink
6-8" Ceiling at Duct Above Sink
BASEMENT BATHROOM PLAN with Ceiling Heights
SCALE: 1/2'1-11-011
ROOM
AREA for
AREA for
--T
AREA for
Proposed
N AME
Light
Light
•Ventilation
Ventil •ion
at
Required
Provided
Require
AREA
in sq. ft.
W
I in square
feet
Family
Room
*R303 Exceptions no. 1 & 2 permit mechanical ventilation and artificial lighting
instead of natural lighting and ventilation.
Paint Contrasting stripe on Soffit
Fascia and Install Emergency Light
Existing
Soffit @
6-911
--E)
.Existing
Fan to
Outside
Modify Duplex outlet to be GFI
Existing
House
Trap
.9
Mim,pt- Existing
-TiLaundry
Room
6-9" Ceiling
TABLE 402.1.2
INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENT
CLIMATE
FENESTRATION
SKYLIGHT
GLAZED
CEILING
WOOD
MASS
FLOOR
BASEMENT
SLAB
CRAWL
ZONE
U-FACTOR
FENESTRA-
R-VALUE
FRAME
WALL
R-VALUE
WALL
R-VALUE
SPACE
TION SHGC
WALL
R-VALUE
R-VALUE
& DEPTH
WALL
R-VALUE
4
0.35
0.55
0.40
49
20 OR
8/13
19
10/13
10, 2'
10/13
13+ 5CI
*We are proposing R-30 Floor Insulation.
Andersen CW135
2'-4 7/8"
Aigh Existing Floor Joists
Grade must be
MAN 6" sloped away from the well.
ScapeWEL side panels must
extend 4" above grade level.
Dome No. M, 4042C illi, I ,
...........
F, (aw ft
Ab
Gravej!d Earth
)EXISTING WINDOW WELL DETAIL
SCALE: 1/2"=V-011
SYMBOL
PLUMBING LEGEND
EXISTING BATHROOM VANITY: PORCELAIN SINK
.16
EXISTING WATER CLOSET: PORCELAIN
[S r
EXISTING SHOWER
SYMBOL
POWER & LIGHTING LEGEND
Electric Panel
Electrical panel.
(E)
Thermostat.
Duplex Electrical receptacle wall mounted @ 12" aff (above
finished floor).
GFI
Duplex receptacle on ground fault interrupter (GFI) mounted
at 42" aff.
Electrical light switch wall mounted at 44" aff.
LED
15 Watt Recessed LED, supplied & installed by the contractor.
60 Watt Porcelain Incandescent Light
Surface mounted 100 watt light fixture with lease.
Exhaust fan 100 cfm.
sD
Smoke detector connected to smoke alarms on eve !y floor.
Carbon Monoxide detector connected to smoke alarms on every floor.
EF
Existing Fluorescent Recessed 2'x2Light Fixture
SCOPE OF PROJECT
1. LEGALIZE BASEMENT WITH RECREATION
ROOM, BATHROOM AND LAUNDRY ROOM.
2. MODIFY EXISTING BATHROOM OUTLET T
BE GROUND FAULT INTERRUPTED.
3. ADD FAN -IN -A -CAN TO THE UTILITY ROO
4. EXTERIOR CELLAR WALLS HAVE
INSULATION IN ACCORDANCE WITH TABLE
402.1.2. SEE DETAIL
5. PAINT CONTRASTING STRIPE ON FASCIA
ABOVE WATER CLOSET AND INSTALL
EMERGENCY LIGHT.
f ...E., bop�,,
I—F—INISHED �BASEMENT 'NOT
4
APPROVED FOR USE As A
SEPARATE APARTMENT OR
DWELUNG UNIT
C"
0 A
T� . �� �.T
PERMIT f?aD-'05L1
BUILDING INSPECItW, Vf<90 Of Rye rook, NY
a L
G zo Lea
F E B 2 7 2020
I VILLAGE OF FOnfE BROOK
RTIMIENT