Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
MP24-139
�yE DR c VILLAGE OF RYE BROOK MAYOR 938 King Street,Rye Brook,N.Y. 10573 ADMINISTRATOR Jason A. Klein (914) 939-0668 Christopher J.Bradbury www.ryebrooknv.gov TRUSTEES BUILDING& FIRE INSPECTOR Susan R. Epstein Steven E. Fews Stephanie J. Fischer David M.Heiser Salvatore W. Morlino CERTIFICATE OF COMPLIANCE January 21,2025 Jonathan Fox&Alison Fox 1 Country Ridge Circle Rye Brook,New York 10573 Re: 1 Country Ridge Circle, Rye Brook,New York 10573 Parcel ID#: 129.82-1-31 This document certifies that the work done under Mechanical Permit#24-139 issued on 10/29/2024 for the installation of a new condenser,coil and gas furnace has been satisfactorily completed. Sincerely, Steven E. Fews Building&Fire Inspector /to QyE BRC��, '9a2 BUILDING DEPARTMENT ❑BUILDING INSPECTOR •`ASSISTANT BUILDING INSPECTOR VILLAGE OF RYE BROOK ❑CODE ENFORCEMENT OFFICER 938 KING STREET • RYE BROOK,NY 10573 (914) 939-0668 FAx (914) 939-5801 www.ryebrook.org - - - - - - - -- - - - - - - - - - - - INSPECTION REPORT - - - - - - - - - - - - - - - - - - - - ADDRESS : l�p, ►J V`� ` DATE: oz PERMIT# m` Z `' ) ISSUED: SECT: BLOCK: LOT: 3 LOCATION: F S� �^����� T A:. } OCCUPANCY: ❑ VIOLATION NOTED THE WORK IS... El- ACCEPTED ❑ REJECTED/ REINSPECTION ❑ SITE INSPECTION REQUIRED ❑ FOOTING ❑ FOOTING DRAINAGE ❑ FOUNDATION ❑ UNDERGROUND PLUMBING NOTES ON INSPECTION: ❑ ROUGH PLUMBING ❑ ROUGH FRAMING ❑ INSULATION ❑ NATURAL GAS `P p (C_ ❑ L.P. GAS ❑ FUEL TANK X/ ❑ FIRE SPRINKLER ❑ FINAL PLUMBING ❑ CROSS CONNECTION ❑ FINAL ,4� d U ❑" OTHER C.. ✓� r� L's I -c.1 -P ti s' � I . �� ICY ■ G1 o h = 1"� N ►[� "a � ■ N _ MEN qj a W Z C ~ w a72W z ao ` � `� ■ Cl) �, � o _ C Lt) en V a w w a " v� C cm O ■ V J w N A ° O o- v _ w oo z w �py, " �Cy �..' ' w O © z U � z .� a _ cn uErg t , a o u c � W oa w 4 a rs E" �-+ Ln x Rr E- z z b o0 1- cn cn c O ZO w c U Ho ° c� u O O U i o U z W O A 0rj) 4 � ° - A ~ F N v saa ' D" BUILD _DFPAR MENT C�C� � D�I'C VIL OF RY OOK - , OCT 2 8 202� 938 KING ET RYE BR NY 10573 -� VILLAGE OF RYE BROOK re . 0v BUILDING DEPARTMENT APPLICATION FOR PERMIT TO INSTALL AND/OR REMOVE HEATING, VENTILATION AND/OR AIR CONDITIONING EQUIPMENT FOR OFFICE USE ONLY: PERMIT#: Approval Date: �Cf,�Z 9 Permit Fee: $ 300 Approval Signature: ALL Other: Disapproved: (fees are non-refundable) 9r#1r*****t4***11 it*rMlr tlr**t**ie**iF it tM 7Y fIrFF ttk*W#***4rfYl1 it ltNlrAr5tlt*it*******ilrir iritwririF**Ak*it*****#dr*irrtrk,t**#*+t*****ie iF**ir,tiraFk DO NOT START WORK or CONSTRUCTION UNTIL A PERMIT HAS BEEN ISSUED BY THE BUILDING INSPECTOR.THE ADr"1NI STRATI:'E FOR WORK PROGRESSED OR COMPLETED N 'ITHOUT A PERMIT IS 12% OF THE TOTAL COST OF CONSTRUCTION WITH A MINIMUM FEE OF$750.00 REQUIREMENTS FOR RELEASE OF PERMIT&CERTIFICATE OF COMPLIANCE: 1. Properly completed& Signed Application. 2. Site/Staging Plan if Required by the Building Inspector. 3. Copy of Licensed Contractor's Liability Insurance. (village of Rye Brook must be listed as certificate holder)&Workers Compensation Insurance On a NYS Board form(Form#C105.2 or Form#U26.3/or NY State Workers Compensation Waiver) 4. Payment of Fccs/Unit: RESIDENTIAL=$I 50.00/unit • COMMERCIAL=$450.00/unit. 5. Complete specifications for each unit being installed. 6. Inspection by the Building Department for removal and/or installation. (48 hour notice required 7. Electrical work requires a separate Electrical Permit&.Electrical Inspection. 8. Plumbing/Gas work requires a separate Plumbing Permit&Plumbing Inspection. Application dated, l —,tVJ — is hereby made to the Building Inspector of the Village of Rye Brook for a permit for the installation and or removal of the HVAC equipment as listed below.The applicant and property owner,by signing this document agrees that said equipment will be installed and/or removed in conformance with all applicable Local,County,Statc&Federal laws, codes,rules and—regulations. q ON ,/� 1. Address: J- C o W ^'�� , C l e Gk SBL: ��// Q �/-3/ Zone: K-I - 2. Property Owner: T O,-Py1-f f4,- fO Y, Address:IS J-,/J-A 2 di, C 1 ;1Z 6,J,yJ Phone#: > _349 Cell#: email: TG�oa(se .4A7•cc•(- ��^� 3. Contractor: 1��s i e 11 .•f/ c Address:�L 60 /�. /YI41 r ✓ .Y, l�� tftro i��/ r Phone#: �`�F'l y 3�/ Cell#: email:4 Q 4. Scope of Work:New Installation( )•Repiacement�Removal( )•Otherel- 5. List Equipment: jA c.1_ C A Qit -5 ,::�/�4! 2 S 6. Location of Equipment: 7. Method of Installation/Removal(list all equipment needed to perform job): 5e IY► t 1 6/1/2024 STATE OF NEW PORK,COUNTY OF WESTCHESTER ) as: ,being duly sworn,deposes and states that he/she is the applicant above named, (print name of individual signing as the applicant) and further states that(s)he is the Heating,Ventilation and/or Air Conditioning Contractor for the legal owner and is duly authorized to make and file this application. That all statements contained herein are true to the best of his/her knowledge and belief,and that any work performed,or use conducted at the above captioned property will be in conformance with the details as set forth and contained in this application and in any accompanying approved plans and specifications,as well as in accordance with the New York State Uniform Fire Prevention&Building Code,the Code of the Village of Rye Brook and all other applicable laws,ordinances and regulations. Sworn to before me this o Sworn to before a this day of 120 _ day of 20 i ature Property Owner re o Applicant] 4 r" � 6. �X SHARIMELILLO �) J �/S Rxiq,Name of Property O er Notary Public,State of New York t k me of A plicant No.01ME6160063 L� Qualified In Westchester County NotaiiPublic Commission Expires January 29,20Z--1 Notary Public This application must be properly completed in its entirety and must include the notarized signature(s) of the legal owner(s) of the subject property, and the applicant of record in the spaces provided. Any application not properly completed in its entirety and/or not properly signed shall be deemed null and void and will be returned to the applicant. 2 6/l/2024 t � N � N a N � 1-1 a s W o M a uu w W M U � 9L4 `. W � � . N z = z `n ^ x Q cw7 Qeq z Q N w � - � z O A N M . ^ L. v, Ln Ln an W - w z ►.a • cri z = ` W Z � - o wenU = A x H W o w - 00 aU a J T I z = W ►-.� = M1 z w a A a 4 aoc c W N _ � r ° � u , oa . _ E, i p V o w 60). ` a � z x V < O � d = a w a U �" ax • zi t l�l�r�l�l4&414141414444&4- 444#A a 4441444464a#44444 �C,33FR � BUILD111 6-ISE �R',TMENT VILLAGE OF RYE 11400K OCT 2 8 2024 938 KING,ST'ET RYE BIj,Of ,NY 10573 VILLAGE OF RYE BROOK wwiv: Vny.gov BUILDING DEPARTMENT ELECTRICAL PERMIT APPLICATION Westchester County Master Electricians License Required / FOR OFFICE USE ONLY A) ,s 9 EP#: C;�/�J Approval Date: i y Permit Fee: $ Approval Signature: Other: DO NOT START WORK or CONSTRUCTION UNTIL A PERMIT HAS BEEN ISSUED BY THE BUILDING INSPECTOR. THE ADMINISTRATIVE FEE FOR WORK PROGRESSED OR COMPLETED WITHOUT A PERMIT IS 12%OF THE TOTAL,COST OF CONSTRUCTION WITH A MINIMUM FEE OF$750.00 Application dated, is hereby made to the Building Inspector of the Village of Rye Brook NY,for the issuance of a Permit to install and/or remove electrical equipment,wiring, fixtures, or to perform other high or low voltage electrical work as per the detailed statement described below. By signing this document, the applicant & property owner agree that all electrical work performed will be in conformances with all applicable Federal,State,County and Local Codes. 1.Address:� �oVti�(/Lj U1�`,j� CiaG� Ul / ` y�SBL:�����c���-3� Zone: �J 2.Property Owner: -TO,-'AITHA N /49. Address: Phone#: 2 0':� -55 Y S Cell#: email: Fax _Sc 3.Master Electrician/Licensed IInstaller: rA^&1 Address: Lic.#: Phone#: Cell#: Yea+3 sb-317, f email: �b rw'c4 C© aa�•C Company Name: F" Address:14b_ '501.ml. e'"l g�i p(1�64A)4—Y 4.Proposed Electrical Work/Fixture CRunt: �/1 acc Conc���f l4,cey►�wl_ 5.3,d Party Electrical Inspection Agency: STATE OF NEW YORK,COUNTY OF WESTCHESTER ) as: ,being duly sworn,deposes and states that he/she is the applicant above named,and does further (print name of individual signing as the applicant) state that(s)he is the for the legal owner and is duly authorized to make and file this application. (Master Electrician/Licensed Installer) The t_mdersigned further state€that all statemen*w contained lte._ .e t�e tc:!te!�eet of performed,or use conducted at the above captioned property will be in conformance with the details as set forth and contained in this application and in any accompanying approved plans and specifications,as well as in accordance with the New York State Uniform Fire Prevention&Building Code,the Code of the Village of Rye Brook and all other applicable laws,ordinances,and regulations. Sworn to_ of re a this o Sworn to be re pie this day o 0 day of ,20 Si re of roe O HARI MELILLO P riY Notary Public,State of New York tgnature of Applicant 104 4%0 � 16 6) No.01ME6160063 �V'C t ame of PrQ erty O Qualified In Westchester County.7� p t e of Ap licant Commission Expires January 29,206-1 Notary Public Notary Public 6/1/2024 STATE WIDE INSPECTION SERVICES, INC., 0•0 • • SWIS JOB APPLICATION •2.7224 1 fax 914.219.1062 1 SWISNYcoml SWISTRAINING.COM Office Use Elect. Permit# �G; —1 l Date Bldg Permit#--X-�(:)41-1,3 9 Scl Ft 7 Plumbing Permit# Final Certificate# City/Village l,+e (vf�j Zip (� �-3 Building Dept. �I� y p �f Q? County Address \ Cross Street Section Block Lot Owner Name/Address(If different than above) l O{�i; 011 h (�pt Contact Number ;S ❑Basement ❑ 1st FI. ❑2nd FI. ❑3rd FI. ❑More Than 3 FI. ❑Garage ❑Attic ❑Outside ❑Residential ❑Commercial Receptacles Special Recept GFCI AFCI Switches Dimmers Smoke Alarms C/O Detector Hood Trash Compact Amt Amps Range(s) Cooktop(s) Oven(s) Dishwashers Refrigerator Disposal Microwave Luminaires Generator Transfer Switch SERVICE Amperage #Panels 1P 3P # Meters # Disconnect ❑Underground ❑ New ❑ Reconnect ❑ Repair ❑Overhead ❑ Upgrade ❑ Disconnect Utility ID# ❑Con Ed ❑ NYSEG ❑Central Hudson ❑ Orange/Rockland PHOTOVOLTAIC SYSTEM PV Modules Inverters AC Disconnect Junction Box Combiner Box Load Center PV Monitor Energy Storage System DC Disconnect ❑Legalization ❑ Safety Inspection ❑Consultation p CC IENIE F DD OCT 2 8 2024 VILLAGE OF RYE BROOK BUILDING DEPARTMENT This application is valid for one(1)year from the date received by SWIS.This application is intended to cover the above listed items to be inspected,if at anytime of inspection additional items have been installed,you are authorized to make the inspection and adjust the fee for the additional items inspected.The applicant declares that there Is no open applications for the above address with any other inspection company.The applicant, owner or authorized agent agrees to all the above terms and conditions as set forth for the application. Email Address ✓1 G t� cily ( Namer �/ � License# Date 1 U 2 -6- -7 c! Signature Address •�p v ` City/State 7ZIp G 1 Company r (}' (AA !�`1i�(h KI r Phone# State Wide Inspection Services 1080 Main Street DEC 2 7 2024 Fishkill, NY 12524 TOVOW/ U S 845 202-7224 Phone 914-219-1062 Fax STATE WIDE INSPECTION SERVICES Email: office(cbswisny.com Website: www.swisny.com Service With Integrity BY THIS CERTIFICATE OF COMPLIANCE STATE WIDE INSPECTION SERVICES CERTIFIES THAT: Upon the application of: Upon Premises Owned by: Gene Branca Electrical Contractor Jonathan &Alison Fox Gene Braca 1 Country Ridge Circle 78 South Regent Street Rye Brook, NY 10573 Port Chester, NY 10573 Located at: 1 Country Ridge Circle, Rye Brook, NY 10573 Section: Block: Lot: Electrical Permit Number: EP 24-216 129.82 1 31 Certificate Number: 2024-8922 Building Permit Number: MP 24-139 A visual inspection of the electrical system was conducted at the Residential occupancy described below.The electrical system consisting of electrical devices and wiring is located in/on the premises at: 1 Country Ridge Circle, Rye Brook, NY 10573 The Basement: Utility Room was inspected in accordance with the NYS and NFPA 70-2017 and the detail of the installation, as set forth below, was found to be in compliance on the 271h day of December 2024. Name Quantity Rating Circuit Type Furnace 01 Condenser 01 Officer: Frank J. Farina This certificate may not be altered in any way and is validated only by the presence of a seal at the location indicated.This certificate is valid for work performed on the date of inspection only. 2 & bj� a - b 00 s Nag g X21 jj _its o , is �o � V 6. 8 rs ng aldp�� K�" jm gsm3 : Q Rd 2 pzg¢,Yb]]� d ~Yryq�d aSQyj (M� m �E o Q '6�� �F �itl 60 it A d �2 J a, cupm w area c� a ,r0 ® z � ® 3nla 3�a1 ,l8 n ® N h w w I ilVHdSY yzW S 3 Z pW 4 = w J II bZ 89'-� m 4 a n 1� �b o5 Q � z� l R,7 2 C N6. - Zow UVIEm r Li I N ND O > > Q> J inec__� 49®® U o� b Of W = w --- <.i in = m W N N �Are� Z a w i a g mm < > o > sW I � W Vf F N� 3 a n — L -—�-- Ca CoJ ®go- z O Z * g bIY1 z I QQJNwm OO�m�Io�Z S� o asp o - -s - -� a o--<• N f� d�ogb 7 —s�yi r3 T 3.0Z,OLOON S33ML•3. a 1Y b yI I \ eo 3r 3 we 9V*Ol eO 3Nn YI NOO9 xA N LZ-i-bL'6Zl l9S 3 Z9006OZ9t #18iNO I� 13MNV1 J/N z i a Qm m a 0 � W O wO wO W U <i 3 Di W-UN O Z 11 5 a$ oo ¢ 7d aawwm0 in mk99 Q a�w 0 m 6 • To Stop Fig. OFF . i� i CIO) A closer look inside the S9-Series Condensing Furnace. Stainless Steel Primary Heat Exchanger withstands higher temperatures, Silicon Nitride Hot Surface Igniter resists corrosion, and is efficient at provides a highly reliable ignition heat transfer, while improving airflow system for longer service life. efficiency in both winter and summer. Multi-Port In-Shot Burners OdaSecondary Heat Exchanger extracts perfectly shape the flame cone �j ;` . A evpn mnrp heat frnm the rrnmhnctinn for the maximum heat possible 'tXJ . i. r .rJ process and is made of corrosion- while using less fuel. resistant 29-4C stainless steel. y Two-Stage Gas Valve i Variable-Speed Blower Motor adjusts fuel use based on your with Comfort-R'"allows quieter heating demand,providing system startups and shutdowns, more comfort with lower, greater efficiency and more longer run times and reduced thorough heat circulation.Also tcmncratl Irc cu,innc __ ..r._._., _...J_. HtVlpJ(,iLJFMUI IIUIi IIUI(y ICVCIJ during summer months. Heavy Steel Insulated Cabinet holds more heat in the furnace, Vortica®II Blower is quiet and ensures greater durability and - efficient in both heating season reduces operating sound. and cooling season, and is only available from Trane. MEN. >� Formed Steel Door with Smoked Two-Speed Draft Inducer works seamlessly i Acrylic View Windows for functional with the two-stage gas valve to enhance yet attractive appearance. efficiency, comfort and reliability. The S-Series Furnace shown is the S9V2 and is for illustration purposes only.Please note that features and components may vary by model.As part of our continuous product improvement,Trane reserves the right to change specifications and design without notice. Annual Furnace Usage Efficiency-{AFUE) 97.0 96.0 tip to 96.0 Variable Speed ECM Blower Motor With Comfort RTM • • High Efficiency 5-speed Constant Torque ECM Motor • Two-Stage Heat • • • Variable-Speed Draft Inducer • Two-Speed Draft Inducer • • Silicon Nitride Hot Surface Igniter + N • Heavy Steel Insulated Cabinet • Automotive-Grade Gaskets And Insulated Blower Compartment K + Stainless Steel Primary Heat Exchanger And Secondary Heat Exchangers o Compatible With Trane CleanEffectsTm TFD Models 41 Self Diagnosinq integrated Furnace Control a 4 4 Compatible With TruComfortTM Variable Speed • All Trane S-Series condensing+90%furnace families have a Lifetime Registered Limited Warranty on the heat exchanger and a 10year Registered Limited Warranty on internal functional parts(residential use only).Ask your dealer forfull warranty information at time of purchase. For installation in SCAQMD only:This furnace does not meet the SCAQMD Rule 1111 14 ng/J NOx emission limit,and thus is subject to a mitigation fee of up to$450.This furnace is not eligible for the Clean Air Furnace Rebate Program:www. C iem lAit run ia(.e rieua(e.can i. A closer look inside 80% Non-Condensing Furnace. Silicon Nitride Hot Surface Igniter Aluminized Steel Heat Exchanger provides a highly reliable ignition -- — - withstands higher temperatures, system for longer service life. resists corrosion, and is efficient at heat transfer, while improving airflow efficiency in both winter and summer. Multi-Port In-Shot Burners perfectly shape the flame cone for the maximum heat possible L -�� Two-Speed Draft Inducer works while using less fuel. I seamlessly with the two-stage gas valve to enhance efficiency, comfort and reliability. Two-Stage Gas Valve adjusts fuel use based on your High efficiency ECM (Electronically heating demand,providing Commutated Motor)helps reduce more comfort with lower, monthly energy bills, reduce noise, longer run times and reduced and deliver the best possible temnerature swinas. airflnUi to kaan vni it hnnnp comfortable. Heavy Steel Insulated Cabinet • Vortica•11 Blower is quiet and holds more heat in the furnace, efficient in both heating season ensures greater durability and and cooling season, and is only reduces operating sound. available from Trane. Gu ■ Formed Steel Door with Smoked Acrylic View Windows for functional yet attractive appearance. The S-Series Fumace shown is the S8x2 and is for illustration purposes only.Please note that features and components may vary by model.As part of our continuous product improvement,Trane reserves the right to change specifications and design without notice. S8X2 S8X1 Annual Furnace Usage Efficiency-(AFUE) K High Efficiency 9-speed Constant Torque ECM Motor • • Two-Stage Heat • Single-Stage Heat • Two-Speed Draft Inducer • Silicon Nitride Hot Surface Igniter • • Heavy Steel Insulated Cabinet • • Automotive-Grade Gaskets And Insulated Blower Compartment • • Aluminized Steel Heat Exchanger • • Compatible With Trane CleanEffects'm TFD Models • • Self Diaclnosinq Integrated Furnace Control • • All Trane S-Series 80%condensing gas furnaces have a 20 year registered limited warranty on the hea anger and a 10 year registered limited warranty on internal functional parts(residential use only).Ask your dealer for full warranty information at time of purchase. For installation in SCAQMD only:This furnace does not meet the SCAQMD Rule 1111 14 ng/J NOx emission limit,and thus is subject to a mitigation fee of up to$450.This furnace is not eligible for the Clean Air Furnace Rebate Program:www. C;Cd1.Ai1T UII IOl,C1�C.UO. -lJl 11. Trane All-Aluminum ComfortTM Coils The advantage you can see.And feel. n n i 1.c iThe in,'Gor cvuNviatv coil :w ui riivfai�y -v _c - aa:, yvivoyoitc...i-.. By teaming up with the outdoor unit and furnace,the coil is a necessary component to provide reliable performance and comfort to your home.Our innovative technology, a rigorous standards, and commitment to quality are reasons why our evaporator coils are the preferred solution to match with a Trane heating or cooling system. Our patented All-Aluminum ComfortTM Coils are designed to withstand the harshest environments and prevent corrosion and leaks better than the competition.Trane has the most experience in the industry with All-Aluminum evaporator coils,transitioning from copper to Aluminum back in 2005,and we have been perfecting the technology eversince! Trane dealers are as hard to stop as a Trane itself. Independent Trane dealers are as personally invested in your comfort as you are, and take great pride in creating your perfect indoor environment.They are some of the most highly trained in the business and have an extensive understanding of the movement and conditioning of air and the expertise to advise, install and maintain the right system for your home. We Encourage Professionalism Through Teehnlelan Certification by NATE (fffD/Ingersoll Rand. Ingersoll Rand(NYSE:IR)advances the quality of life by creating comfortable,sustainable and efficient environments. Our people and our family of brands—including Club Car',Ingersoll Rand",Thermo King'and Trane'—work together to enhance the quality and comfort of air in homes and buildings; transport and protect food and perishables; and increase industrial productivity and efficiency.We are a$14 billion global business committed to a world of sustainable progress and enduring results. r �IOJngersoll Rand. THERMO KING 0TRANS° TRINE" HIU(ill(lUfil %Ird5t'Q Heat Pump / Cooling Coils 1 -1 /2 - 5 Ton 4TXC-Series Coils Heat Pump /Cooling Coils for R-410A V vri 22-1960-1 B-EN TAME" Aluminum Heat Pump Coil Nomenclature 4 T X C A 0 0 2 D S 3 H C A A Refrigerant Type 4 - R410A TTTTT T TTTTTTT Product Family T-Premium (Heat Pump or Convertible Coil) Coil Design X - Direct Expansion Evaporator Coil Product Family - %.a5t�d A ouii A- Uncased A Coil F - Cased Horizontal Flat Coil Coil Width (Cased/Uncased) A- 14.5"/ 13.3" B - 17.5"/ 16.3" C - 21.0"/ 19.8" D - 24.5"/23.3" H - i 0.5"' Refrigerant Line Coupling 0 - Brazed Model Number Distinguisher Major Design Change ttriciency C - Standard S - Hi Efficiency Refrigerant Control 3 -TXV- Non-Bleed Coil Circuitry H - Meat F-ump Airflow Configuration A- Upflow Only U - Upflow/ Downflow H - Horizontal Only C - Convertible - Upflow, Downflow, Left or Right Airflow Minor Design Change Unit Parts Identifier 22-1960-1 B-EN 0 General TRANE" Data PRODUCT SPECIFICATIONSI't 4TXC-DS--- HIGH EFFICIENCY STAGED SPLIT SYSTEM HEAT PUMP/ COOLING COMFORTrm COILS -- CASED UPFLOW/ DOWNFLOW/HORIZONTAL 4TXr.Aoo9r1$1Hr`R 4TXr.Pnn.if1RAHr.R 4TXr`AnA9r1R31-r.R 4TXr:Ron4f1SAHr.R 4TXr.r.nnFflC.qHr.R INDOOR COIL--Type PLATE FIN PLATE FIN PLATE FIN PLATE FIN PLATE FIN 1.5-2.0 1.5-2.5 2.5-3.0 3.0-3.5 3.0-3.5 Cooling Capacity(Tons) 2/20 3/14 2/20 3/12 3/12 o Cooling ws I 5.0 Face Area(sq.ft.) 3.0 3.5 3/8 3/8 3/8 Tube Size 3/8 3/8 3/8 3/8 3/8 Non-Bleed TXV Non-Bleed TXV Non-Bleed TXV Non-Bleed TXV Non-Bleed TXV Refrigerant Control Internal check valve Yes Yes Yes Yes Yes Drain Conn.Size(e 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT Drat (nnn .Size c See Outline Drawing See Outline Drawing See Outline Drawing See Outline Drawing See Outline Drawing rhirREFRIGERANT R-410A R-41 OA R-410A R-410A R-410A CONNECTIONS BRAZED BRAZED BRAZED BRAZED BRAZED Line Size Gas(in.) 3/4 3/4 3/4 7/8 7/8 Line Size Liquid(in.) 3/8 3/8 3/8 3/8 3/8 DIMENSIONS(in.) H X W X D H X W X D H X W X D H X W X D H X W X D Crated(H x W x D) 21-9/16 x 18-1/2 x 27-1/2 21-9/16 x 21-1/2 x 27-1/2 26-9/16 x 18-1/2 x 27-1/2 26-9/16 x 21-1/2 x 27-1/2 26-9/16 x 25 x 27-1/2 Uncrated 17-1/2 x 14-1/2 x 21-112 17-1/2 x 1 7-1/2 x 21-112 22-112 x 14-1/2 x 21-112 22-112 x 17-112 x 21-112 22-112 x 21 x 21-1/2 WEIGHT(Ibs) 42/34 50/42 49/41 58/50 60/52 Shipping--Net 4TXCB006DS3HCB 4TXCC007DS3HCB 4TXCD008DS3HCB 4TXCC009DS3HCB 4TXCDOtODS3HCB INDOOR COIL--Type PLATE FIN PLATE FIN PLATE FIN PLATE FIN PLATE FIN Cooling Capacity(Tons) 3.5-4.0 3.5-4.0 3.5-5.0 3.5-5.0 3.5-5.0 Rows/F.P.I. 3/14 3/14 3/14 3/16 3/16 Face Area(sq.ft.) 5.5 6.0 6.0 7.0 7.0 Tube Size 3/8 3/8 3/8 3/8 3/8 Refrigerant Control Non-Bleed TXV Non-Bleed TXV Non-Bleed TXV Non-Bleed TXV Non-Bleed TXV Internal check valve Yes Yes Yes Yes Yes Drain Conn.Size(in.) 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT Duct Connections See Outline Drawing See Outline Drawing See Outline Drawing See Outline Drawing See Outline Drawing REFRIGERANT R-410A R-410A R-410A R-410A R-410A CONNECTIONS BRAZED BRAZED BRAZED BRAZED BRAZED Line Size Gas(in.) 7/8 7/8 7/8 7/8 7/8 Line Size Liquid(in.) 3/8 3/8 3/8 3/8 3/8 DIMENSIONS(in.) H X W X D H X W X D H X W X D H X W X D H X W X D Crated(H x W x D) 30-13/16 x 21-1/2 x 27-1/2 30-13/16 x 25 x 27-1/2 30-5/8 x 28-1/2 x 27-1/2 34-3/4 x 25 x 27-1/2 34-3/4 x 28-1/2 x 27-1/2 Uncrated 26-3/4 x 17-1/2 x 21-1/2 26-3/4 x 21 x 21-1/2 26-3/4 x 24-1/2 x 21-1/2 30-3/4 x 21 x 21-1/2 30-3/4 x 24-1/2 x 21-1/2 WEIGHT(Ibs) 63/55 69/61 72/64 78/70 81 /73 Shipping Net ! 1 TV Jco;:s aia LstfaJ •w.uus �a. con -tionars and L cat,pumps(A.: 01'a nchid n 1.i nn tAIv).L1j 11. uw -n l 1 ulmu1l Refer to the Split System Outdoor product information site or www.ahrinet.org 22-1960-1 B-EN 3 rAWE' Performance Data PRESSURE DROP CHARACTERISTICS FOR COOLING AND HEAT PUMP COILS AIRFLOW(CFM)VS.PRESSURE DROP ACROSS WET COIL PRESSURE DROP(INCHES OF WATER COLUMN) Model 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 4TXCA002DS3HCB 225 340 430 510 585 650 715 775 4TXCA032DS3HCB 375 570 725 860 985 1100 1200 1305 4TXCB003DS3HCB 350 525 665 790 900 1000 1095 1180 4TXCB004DS3HCB 1 440 1655 1825 1 970 11100 11220 11330 1 1435 4TXCB006DS3HCB 430 640 815 965 1095 1220 1335 1445 4TXCC005DS3HCB 520 770 970 1145 1300 1440 1570 1695 4TXCC007DS3HCB 505 760 965 1140 1300 1445 1580 1710 4TXCC009DS3HCB 490 740 940 1120 1280 1425 1565 1695 4TXCD008DS3HCB 580 870 1100 1300 1485 1650 1805 1950 4TXCD010DS3HCB 555 835 1065 1265 1445 1615 1770 1915 R-22 CONVERSION NON-BLEED TXV KITS Coil R-22 TXV Kit 4TXCA002DS3HCB 4TXCA032DS3HCB 4TXCB003DS3HCB 2AYTXVH3H1836A 4TXCB004DS3HCB 4TXCC005DS3HCB ATvrannrnc3urR 4TXCC007DS3HCB 2AYTXVH3H4248A 4TXCDOO8DS3HCB 4TXCC009DS3HCB 2AYTXVH3H6060A 4TXCD010DS3HCB 4 22-1960-1 B-EN < } m $ Cl) / o \ I § § \ F— & Cl) § ® / \ ƒ : cn R / \ ° - # m g # ! \ / / / \ ` CO - - - - a o o\ ~ \ § I -- n - - - +3 - / \ / \ / X - \ I - / \ I = 2 / - g O o , CD CD X \ \ § ice 2 > - - _ � ƒ • . § \ ` - - - � o S \ / I ° ■ " R _ f �o 0 0 o ` � 2,,9 BB m Em TAME' Trane-by Trane Technologies (NYSE:TT), a global climate innovator-creates comfortable, energy efficient indoor 61-f0 Urllllelllb fur uulrllrleruiar arid resruenuar a( p;Iuditui-lb. rul- i-rrure ifrlurriiabui-r, p6a6e Vlbll iraii6.60-1-1 ul tranetechnologies.com. c @Ukus c04ITSus ISTFn Intartalt Trane has a policy of continuous data improvement and it reserves the right to change design and specifications without notice.We are committed to using environmentally conscious print practices. 22-1960-1 B-EN 12 Apr 2021 Supersedes 22-1960-1 A-EN(October 2020) ©2021 Trane 0 rRME' Product Data Split System Cooling 4TTR3018H1000N 4TTR3024H1000N - - - 4TTR303OH1000N 4TTR3036H1000N 4TTR3042E1000N 4TTR3043A1000N 4TTR3048E1000N 4TTR3048E1000P 4TTR3049A1000N 4TTR306OE1000N June 2020 22-1842-8R-EN � C N = TECHNOLOGIES' 0 MANE, Outline Drawing B SERVICE PANEL C ELECTRICAL AND REFRIGERANT COMPONENT CLEARANCES PER PREVAILING CODES TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR AT LEAST 152415 FEET) ABOVE UNIT,UNIT SHOULD BE PLACED SO ROOF RUN-OFF WATER DOES NOT POUR DIRECTLY ON UNIT ANU DMUULU Lit Al LtAJ I.Alb I rr I YHUM WALL ANU ALL SURROUNDING SHRUBBERY ONTWO SIDES. _ OTHERTWO SIDES UNRESTRICTED 7- ELECTRICAL SERVICE K PANEL 25(11 rvA Nnr a A LOW VOLTAGE 28.6 I1-1lel DIA.K.O.I 22.2 0/8)DIA.HOLE IN CON BOX BOTTOM FOR ELECTR POWER S LIOU ID LINE SERVICE VALV E., I.D.FEMALE BRAZECONNECTION WITH 1!4"SAFLARE PRESSURETAP FITTIN FIG.t K.O.FOR ALTERNATE ELECTRICAL ROUTING F.nm Il,.•� I1�5�000 - -UAJ LIIY[Ir9 fUhri LiALC 6[lfV1Ut vALV[, "D. I.D.FEMALE BRAZED CONNECTION WITH 114"SAE FLARE PRESSURE TAP FITTING.A Model Base A B C D E F G H J K 4TTR3018H 2 (28-3/4) (28-1/2) (25-5/8) 3/4 3/8 (5) 2-1/4) 715/8) (1-1/2) (18) 4TTR3024H 2 (28-3/4) (28 Z1/2) 25-5/8) 3/4 3/8 (5-3/8) (2-5/8) (8 1/4) 2-1/4 (18) 4TTR3030H 2 (28-3/4) (28-%2) (25 5/8) 3/4 3/8 5-3/8) (2-5/8) 8-1/4) 2-1/4 16 4TTR3036H 3 730 829 756 3/4 3/8 137 79 197 60 508 (28-3/4) (32-5/8) (29-3/4) (5-3/8) (3-1/8) (7-3/4) (2-3/8) (20) 4TTR3042E 3 (28-3/4) (32 5/8) (29-3/4) 7/8 3/8 (6) (3 7/8) (8-5/8) (3-3/8) (0) 4TTR3043A 4.2 741 46 870 7/8 3/8 (6) 19 6 508 (29-1/8) (37-1/4) (34-1/4) (6) (3-7/8 (8-5/8) (3-3/8) (20) 4TTR3048E 3 (36-3/4 32-5/8 29-3/4) 7/8 3/8 16 3 7/8 8-5/8 (3-3/8) (20 4TTR3049A 4.2 (29 1/8) (37 1/4) (34-1/4) 7/8 3/8 (6) (3-7/8) (8 5/8) 3-3/8 (0) 94 94 0 15 98 19 6 508 4TTR3060E 4.4 �7_1/a1 (y7_1ld1 !aa_1la1 7/8 3/8 rF1 !3_7!R_1 �a_clal !y_Z�f21 !2m 2 22-1842-8R-EN 0 TAME` Product Snecifications • Model No.(a) 4TTR3018H1000N 4TTR3024H1000N 4TTR3030H1000N POWER CONNS.—V/PH/HZ(b) 208/230/1/60 208/230/1/60 208/230/1/60 MIN.BRCH.CIR.AMPACITY 12 18 16 BR.CIR.PROT.RTG.—MAX.(AMPS) 20 30 25 COMPRESSOR CLIMATUFF®-SCROLL CLIMATUFF®-SCROLL CLIMATUFF®-SCROLL RL AMPS—LR AMPS 9—48 12.8—58.3 12.3—63 Outdoor Fan FL AMPS 0.64 0.64 0.9 Fan HP 1/8 1/8 1/8 Fan Dia(inches) 23.0 23.0 18.9 Coil SPINE FIN TM SPINE FINT SPINE FINT Refrigerant R-410A 4 LBS.,2 OZ 4 LBS.,2 OZ 4 LBS.,2 OZ NE SILO—IN.V.U.GHQ LINE SIZE—IN.O.D.LIQ.Cc) 3/8 3/8 3/8 Charge Spec.Subcooling 10OF 10OF 10OF Dimensions H x W X D Crated(IN.) 34 x 30.1 x 33 34 x 30.1 x 33 30 x 27 x 30 Weight—Shipping(lbs.) 167 169 157 Weight—Net(lbs.) 140 142 137 optional Accessories: Anti-short Cycle Timer TAYASCT501A TAYASCTS01A TAYASCTS01A Evaporator Defrost Control AY28X079 A.Y28Y079 AY28X079 Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 Extreme Condition Mount Kit BAYECMT023 BAYECMT023 BAYECMT023 Start Kit BAYKSKT263 BAYKSKT263 BAYKSKT263 �aRRtv3t l')Cu A"::t �To�' r ,•' �::/CCU:T.3.^.2 Seacoast Kit BAYSEAC001 BAYSEAC001 BAYSEAC001 Low Ambient Kit BAYLOAM103 SAYLOAM103 BAYLOAM103 Service Valve Panel Cover Refrigerant Lineset(d) (^) Certified in accordance with the Unitary Air-conditioner equipment certification program which is based on AHRI standard 210/240. (b) Calculated in accordance with N.E.C.Only use HACR circuit breakers or fuses. Cc) Standard line lengths—60',Standard lift—60'Suction and Liquid line.For Greater lengths and lifts refer to refrigerant piping software Pub#32-3312-0*(*denotes latest revision). (d) 25,30,35 and 50 foot linesets available.Fora complete listing of lineset options available from equipment or supply stores, referto theTrane Residential and Light Commercial Product Handbook. 22-1842-8R-EN 3 ® TRANEf' Product Specifications Model No.(a) 4TTR3036H1000N I 4TTR3042E1000N 4TTR3043A1000N POWER CONNS.—V/PH/HZ(b) 208/230/1/60 208/230/1/60 208/230/1/60 MIN.BRCH.CIR.AMPACITY 18 22 22 BR.CIR.PROT.RTG.—MAX.(AMPS) 30 35 35 COMPRESSOR CLIMATAUFF®-SCROLL CLIMATUFF®-SCROLL CLIMATUFF®-SCROLL RL AMPS—LR AMPS 14.1—75 17.0—124 16.7—109 Outdoor Fan FL AMPS 0.7 0.7 1.05 Fan HP 1/8 1/8 1/5 Fan Dia(inches) 23.0 23 27,5 Coil SPINE FINT SPINE FINTM SPINE FINw Refrigerant R-410A 4 LBS.,2 OZ 5 LES.,2 OZ 6 LBS.,7 OZ LINE SIZE—IN.O.D.GAS<<) 3/4 7/8 7/9 LINE SIZE—IN.O.D.LIQ.(c) 3/8 3/8 3/8 Charge Spec.Subcooling 10OF 10OF 120F Dimensions H x W X D Crated(IN.) 34 x 30.1 x 33 34 x 30.1 x 33 34.4 x 35.1 x 38.7 Weight—Shipping(lbs.) 175 200 216 Weight—Net(lbs.) 147 172 184 Optional Accessories: Anti-short Cycle Timer TAYASCT501A TAYASCT501A TAYASCTS01A Evaporator Defrost Control AY28XO79 AY28XO79 AY28XO79 Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 Extreme Condition Mount Kit BAYECMT023 BAYECMT004 BAYECMT004 Start Kit BAYKSKT263 BAYKSKT263 BAYKSKT263 BAYCCHT302 Dl1V!•!`LIT7n1 O11 V!"!`LJT7n1 Seacoast Kit BAYSEAC001 BAYSEAC001 BAYSEAC001 Low Ambient Kit BAYLOAM103 BAYLOAM103 BAYLOAM103 Service Valve Panel Cover TAYSVPANLOG32PA TAYSVPANL0032AA TAYSVPANL3343AA Refrigerant Lineset(a) ca) Certified in accordance with the Unitary Air-conditioner equipment certification program which is based on AHRI standard 210/240. (b) Calculated in accordance with N.E.C.Only use HACR circuit breakers or fuses. (c) Standard line lengths—60',Standard lift—60'Suction and Liquid line.For Greater lengths and lifts refer to refrigerant nininn cnftwara Pi ohit77-7717-n*(*rinnntPc latact rnvicinn) (a) 25,36,35 and 50 foot linesets available.For a complete listing of lineset options available from equipment or supply stores, refer to theTrane Residential and Light Commercial Product Handbook. 4 22-1842-8R-EN ® 7aws Product Specifications Model No.(a) 47TR304BE1000N/P 47TR3049A1000N 47TR3060E1000N POWER CONNS.-V/PH/HZ(b) 208/230/1/60 208/230/1/60 208/230/1/60 MIN.BRCH.CIR.AMPACITY 28 28 27 BR.CIR.PROT.RTG.-MAX.(AMPS) 45 45 45 COMPRESSOR CLIMATUFF®-SCROLL CLIMATUFF®-SCROLL CLIMATUFF®-SCROLL RL AMPS-LR AMPS 21.8-117 21.8-117 20.8-127.1 Outdoor Fan FL AMPS 0.93 1.05 1.05 Fan HP 1/5 1/5 1/5 Fan Dia(inches) 23 23 27.5 Coil SPINE FINTM SPINE FIN TM SPINE FINTw Refrigerant R-410A 6 LBS.,7 OZ 6 LBS.,7 OZ 7 LBS.,10 OZ LINE SIZE-IN.O.D.GAS W 7/8 7/8 7/8 LINE SIZE-IN.O.D.LIQ.W 3/8 3/8 3/8 Charge Spec.Subcooling 10OF 10OF 10OF Dimensions H x W X D Crated(IN.) 42 x 30.1 x 33 42 x 30.1 x 33 42.4 x 35.1 x 38.7 Weight-Shipping(lbs.) 233 212 246 Weight-Net(lbs.) 197 189 211 Optional Accessories: Anti-short Cycle Timer TAYASCT501A TAYASCT501A TAYASCT501A Evaporator Defrost Control AY28XO79 AY28XO79 AY28XO79 Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 Extreme Condition Mount Kit BAYECMT004 BAYECMT004 BAYECMT004 Start Kit BAYKSKT263 BAYKS- 263 BAYKSKT263 Crankcase Heater Kit BAYCCHT301 BAYCCHT301 BAYCCHT301 Seacoast Kit BAYSEAC001 BAYSEAC001 BAYSEAC001 Low Ambient Kit BAYLOAM103 BAYLOAM103 BAYLOAM103 Service Valve Panel Cover TAYSVPANL0044AA 1 TAYSVPANL0044AA TAYSVPANL0044AA Refrigerant Lineset(d) (a) Certified in accordance with the Unitary Air-conditioner equipment certification program which is based on AHRI standard 210/240. (h) Calculated in accordance with N.E.C.Only use HACR circuit breakers or fuses. a) Standard line lengths-60',Standard lift-60'Suctlon and Liquid line.For Greater lengths and lifts refer to refrigerant piping software Pub*32-3312-0*(*denotes latest revlslon). (d) 25,30,35 and 50 foot linesets available.Fora complete listing of lineset options available from equipment or supply stores, refer to theTrane Residential and Lioht Commercial Product Handbook. Sound Power Level A-Weighted MODEL Sound Power Full Octave Sound Power(dB) Level[dB(A)] 63 125 250 1 500 1000 2000 4000 8000 Hz* Hz Hz Hz Hz Hz Hz Hz 47TR3018H1 72 73.7 71.4 65.4 68 67.3 62.9 56 50.3 4TTR3024H1 74 47.9 60.5 64.1 71.2 71.2 69.0 58.2 51.5 4TTR3030H1 72 69.9 69.6 69.1 68.6 68.7 60.9 56.2 48.9 4TTR3036H1 68 74.7 65.0 65.2 66.4 63.6 58.7 56.3 52.8 4TTR3042E1 72 77.6 68.3 67.4 65.6 67.4 58.2 54.1 47.6 4717113043A1 72 77.6 68.3 67.4 65.6 67.4 58.2 54.1 47.6 4TTR3048E1 74 72.5 72.3 69.2 67.5 72.3 60.2 55.2 54.2 4TTR3049A1 74 72.5 72.3 69.2 67.5 72.3 60.2 55.2 54.2 47TR3060E1 71 81 72 69 69 66 60 57 54 Note:Rated in accordance with AHRI Standard 270-2008*For Reference Only 22-1842-8R-EN 6 TRANY Accessory Description and Usage Anti-Short Cycle Timer — Solid state timing device that prevents compressor recycling until five(5) minutes have elapsed after satisfying call or power interruptions. Use in area with questionable power delivery,commercial applications,long lineset,etc. Evaporation Defrost Control — SPST Temperature actuated switch that cycles the condenser off as indoor coil reaches freeze-up conditions. Used for low ambient cooling to 30°F with TXV. Rubber Isolators — Five(5) large rubber donuts to isolate condensing unit from transmitting energy into mounting frame or pad. Use on any application where sound transmission needs to be minimized. Hard Start Kit — Start capacitor and relay to assist compressor motor startup. Use in areas with marginal power supply,on long linesets, low ambient conditions,etc. Extreme Condition Mount Kit — Bracket kits to securely mount condensing unit to a frame or pad without removing any panels. Use in areas with high winds,or on commercial roof tops,etc. AHRI Standard Capacity Rating Conditions AHRI Standard 210/240 Rating Conditions 1. Cooling 80°F DB,67°F WB air entering indoor coil,95°F DB air entering outdoor coil. 2. High Temperature Heating 47°F DB,43°F WB air entering outdoor coil,70°F DB air entering indoor coil. 3. Low Temperature Heating 17°F DB air entering indoor coil. 4. Rated indoor airflow for heating is the same as for cooling. AHRI Standard 270 Rating Conditions — (Noise rating numbers are determiend with the unit in cooling operations.)Standard Noise Rating number is at 95°F outdoor air. Model Nomenclature Outdoor Units 1 2 3 4 5 6 7 8 9 10 1112 13 14 15 4 T W V 0 0 3 6 A 1 0 0 0 A A Refrigerant Type 2=R-22 4=R-410A TRANE prsdust Typ? W=Split Heat Pump T=Split Cooling Product Family V=Variable Speed M or B=Basic 2=Leadershlp—Two Stage A=Light Commercial X=Leadership L=Side Discharge R-ReplacementlRetail Family SEER 3=13 6=16 0=20 4=14 8=18 5=15 9=19 Split System Connections 1-6 Tons i 0=Brazed Nominal Capacity in 000s of BTUs Major Design Modifications Power Supply 1=200.23011160 or 208.23011160 3-200.23013160 4=46013160 Secondary Function Minor Design Modifications iinii Pxris iuenifFe 6 22-1842-8R-EN 0 TAM/Ee Schematic Diagrams .. Figure 1. 1.5 — 3.5 Ton Models TO POWER SUPPLY PER UNIT NAMEPLATE AND LOCAL CODES I E 1 CF FAN CAPACITOR —� SEE PRODUCT DATA CN WIRE CONNECTOR I FOR OPTIONAL START CPR COMPRESSOR Qa NIT ACCESSORY I r- ---------------I m CR RUN CAPACITOR rn CS CC! CS STARTING CAPACITOR -I CSR ICSR CAPACITOR SNITCHING RELAY 4"�------'Ro-------------jv71 eR'10, 2 s —BKral----- Ms 2 I R r___ DDT OUTDOOR THERMOSTAT /h - BK/BL - HPCO NIGH PRESSURE CUTOUT SWITCH CAPACITOR � LPCO LOW PRESSURE CUTOUT SWITCH OD B ORJ MS COMPRESSOR MOTOR CONTACTOR FAN P O a TNS TRANSFORMER MTR BK F C H N CPR j IOL INTERNAL OVERLOAD PROTECTOR TNERMALLY D -—-— —J PROTECTED V INTERNALLY TYPICAL I ' TYPICAL I ®WARNING ®CAUT I ON HPCO LpCO i AIR HANDLER THERMOSTAT QQIQ r I HAZARDOUS VOLTAGEI USE COPPER CONDUCTORS ONLYI J I O I I DISCONNECT ALL ELECTRICAL UNIT TERMINALS ARE NOT DESIGNED 0 I POWER INCLUDING REMOTE TO ACCEPT OTHER TYPES OF CONDUCTORS. ' DISCONNECTS BEFORE SERVICING. Follvre to do so my roes#deeage MS I I I —I i Y' Y�I ———— i t -�J I iallere to disconnect poser to the egeipont. before servicing can cosse BL ----T-- YO I I ' severe daafi.I personal injvey or MOTES IU F (OPTIONALIi Ol_ W3 HEAT I I I I ,-COLOR OF WINE I (REMOTE)' ; I rO CONTROLSI I I BK/BL IODT�P-BK---}-' Z2 -COLOR OF MANNER WZ I GO BLACK RD RED OR ORANGE J I I I I I RL BLUE IN WHITE OR GREEN I I — 1—— BR BROWW TL YELLOW PI PURPLE ODT-A (OPTIONAL) I (1--- WI —�— It � WI I PN PINK -------BK----------' I L_____J I I NOTES: OGATAIR AIFC DIED, OOT-B T-1 11 NOT USED. AID IUNPEII MUST BE DEMOTE O BOX ITWEEN AM APPROVED WEATHER PROOF ENCLOSURE. 2. IF ODT-A IS NOT USED. ADD JUMPER BETWEEN B TNB ' I WI A W2 AT AIR HANDLER. O L� R 241— I' I J� I S. LOW VOLTAGE 124 V) FIELD WIRING MUST BE IO AMPS MINIMUM. H. USE COPPER CONDUCTORS ONLYI I I I I ' {TO POWER SUPPLY FOR CANADIAN INSTALLATIONS POUR INSTALLATIONS CANADIENNES 1 ER LOCAL CODE) �����T��\/ _—_—J I---_—_—J CAUTION: NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING 15OV-70-6ROUND ATTENTI ME CONVtEBIT PAS AUX INSTALLATIONS DE PLUS DE ISO V A LA TERRE PRINTED FROM D157047P03 REVA 22-1842-8R-EN 7 ® TRANE' Schematic Diagrams Figure 2. 4.0 - 5.0 Ton Models l TO POWER SUPPLY PER UNIT NAMEPLATE AND LOCAL CODES 1 -_SEE OPTIONAVICEL FACTS T _ c Fql arrlauL START C13 NIT ACCESSORY m L E G E N D I CS —— M�� BR CSR I^SR NS-200 CF FAN CAPACITOR � i NVB�onioL—ri— H CN WIRE CONNECTOR RD BK/BL CPR COMPRESSOR a2RD I -—- CR RUN CAPACITOR OD BRPR d•OR+�fl = CS STARTING CAPACITOR SWITCHIN+�� laCSR CAPACITOR StITCHINB RELAY MQ BK H E CPR IODT OUTDOOR THERMOSTAT THERMALLY -—_ , m HPCO HIGH PRESSURE CUTOUT SWITCH PROTECTED LPCO LOW PRESSURE CUTOUT SVITCH INTERNALLY MS COMPRESSOR MOTOR CONTACTOR TNS TRANSFORMER IIU INTFRNAI OWFRIAAA PRATFtTAR TYPICAL I I ,*-,OLON OF WINE HPCO LPCO AIR HANDLER TYPICAL THERMOSTAT I BK/B�aaR OF MARIIEN NLACN No NEo ON aANE J J , BL BLUE TN WHITE WR SNEER L �1 P100 IL YELLOW M TOR/L[ CIS NK Yi Yi ----T�--� I TI �� I FOR CANADIAN INSTALLATIONS I of POUR INSTALLATIONS CAuAD!ENNES i —� lol , i . CAUTION: NOT SUITABLE FOR USE ON NOTES IttHEAT , SYSTEMS EXCEEDING 150V-TO-GROUND (OPTIONAL E I CONTROLS I i I ATTENTION:NE CONVIENT PAS AUX y INSTALLATIONS DE PLUS DE 150 V A ODT _ LA TERRE _ -BK—X- JIW2� ----r-- ... W2 DDT A C>—BK (OPTIONAL) I I I L AK X I I BL TNs , — I—I—RD—CR I TO POWER SUPPLY PER LOCAL CODES PRINTED FROM D160439POI REVA 8 22-1842-8R-EN ® TRAN6' Schematic Diagrams Figure 3. 4.0 — 5.0 Ton Models LPCO HPCD gK OD Ia �-- PR FAN BNTBL ' 181 �� 8R MT DR '--� t TXEANALLT PNOTKTEI M1Et: .=PI INTERNALLY _ 1. IF UST-B 13 NOT USED.AM JUNIPER BETWEEN 12.Nf AT All NARDLEN. IF US[O,ODT-1 Ktt K NWNTEI(EMOTE OF OUTIIOL ME IN AN APPROVED KATKI PROOF EKLO.UAE. !. li ODT-A 11 NOT USW,ADD JWP[N BETWEEN tl R K AT All NANDLLA. I ----------- _ _ -----_—_—_--� 1.L01 YOLTAK IN YI FICLD IIIIM NOT IE 11 AM YIMIMW. I 4.USE COPPER COMKTORA ONLY, LEGEND I 24 Y I FACTOIIY 1F RELAY CONTACT IN.O1 I a I LIKENINIM 0- NEUI CONTACT MCI �—� 1H1E1L1 DM Y V 2 TNOMI4TIA II \ I C0A PACIT R RD } ORO LINE =14 v IEL1 IT-E "lp X XIK FACTOR FACT. I BIIIM�•� �®{p ��r"t0"ITA• IIII NE E NRrIR T�C}E �bINIWAL ONWWD P""lo T RR UMTIC COIL F TART BNWO T2 ITC ".Ivio"OUT, U.MNT JICTIp MS CAPAC TON y.wp viO1 viol" WIRE OR+ es �0 LITEAI NA WiTuwil /�"I"(raw, I I T ' ` CS UNnu ILauMND X 11 I X X l i I I 1 i l _—_— BKYURD i X2 BOTH IN OR/TL F ISF 01TAu r—� I I uLNOI L,, X I I BK BK , GR YL m m � I - J m m -��Y X I I coPTIDNu, , I X BK ---------- 1T0 POWER B-----------------� --_— DPPLT PNO WIT NAKPurEf AM LOCAL CODER PRINTED FROM D160439POI REVA 22-1842-8R-EN 9 0 TRAAAF Mechanical Snecification Ontions General The outdoor condensing units are factory charged with the system charge required for the outdoor condensing unit,ten (10)feet of tested connecting line, and the smallest rated indoor evaporative coil match.This unit is designed to operate at outdoor ambient temperatures as high as 115°F. Cooling capacities are matched with a wide selection of air handlers and furnace coils that are AHRI certified.The unit is certified to UL 1995. Exterior is designed for outdoor aonlication. Casing Unit casing is constructed of heavy gauge,galvanized steel and painted with a weather-resistant powder paint finish.The corner pane4s are prepainted.M pane4s are subjected to our 1,000 hour salt spray test. Refrigerant Controls Refrigeration system controls include condenser fan,compressor contactor and low and high pressure switches.A factory supplied,field installed liquid line drier is standard. Compressor The compressor features internal over temperature and pressure protection.Other features include: Centrifugal oil pump and low vibration and noise. Condenser Coil The outdoor coil provides low airflow resistance and efficient heat transfer.The coil is protected on all four sides by louvered panels. Low Ambient Cooling Ac mnntifnrtitr.-H this cxictom hac a rnnlinri ranarity to r,F°F.Tha Arlriitinn of an avannratnr defrost control permits operation to 40°F.The addition of an evaporator defrost control with TXV permits low ambient cooling to 30°F. The addition of the BAYLOAM107A low ambient kit permits ambient cooling to 20°F. Thermostats—Cooling only and heat/cooling (manual and automatic change over). Sub-base to match thermostat and locking thermostat cover. 10 22-1842-8R-EN I + O AC UKi DATE(MM/DD/YYYY)CERTIFICATE OF LIABILITY INSURANCE 02/16/2024 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER NAME CT CLIENT CONTACT CENTER _ FEDERATED MUTUAL INSURANCE COMPANY PHONE I FAX HOME OFFICE: P.O.BOX 328 (A/C,No,Ext):888-333-4949 (A/c,No):507-4464664 OWATONNA, MN 55060 ADDRESS:CLIENTCONTACTCENTER FEDINS.COM INSURERS AFFORDING COVERAGE NAIL ff INSURER A:FEDERATED MUTUAL INSURANCE COMPANY 13935 INSURED 286468-4 INSURER B:FEDERATED RESERVE INSURANCE COMPANY 16024 ARCTIC MECHANICAL INCORPORATED INSURER C: 460 N MAIN ST PORT CHESTER, NY 10573-3310 INSURER D: INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER:90 REVISION NUMBER: 1 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICY NUMBER POLICY EFF POLICY EXP LIMITS ITRX COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $1,000,000 CLAIMS-MADE ❑X OCCUR DAMAGE TOCe CCUrren JENTED PREMISES $100 000 MED EXP(Any one person) EXCLUDED A N N 1887386 01/18/2024 01/18/2025 PERSONAL&ADV INJURY $1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $2,000,000 X POLICY �ECT LOC PRODUCTS&COMP/OP AGO $2,000,000 OI HER: AUTOMOBILE LIABILITY COEa aBINMBINED SINGLE LIMIT $1,000,000 X ANY AUTO BODILY INJURY(Per Person) A OWNED AUTOS ONLY N N 1887386 01/18/2024 01118/2025 BODILY INJURY(Per Accident) AUTOHIRED AUTOS ONLYISCHFIDULED NON-OWNED PROPERTY DAMAGE AUTOS ONLY X UMBRELLA LIAB X OCCUR EACH OCCURRENCE $5,000,000 A EXCESSLIAB CLAIMS-MADE N N 9907994 01/18/2024 01/18/2025 AGGREGATE $5,000,000 LIED I X IRETENTION$10,000 WORKERS COMPENSATION X PER STATUTE OTHER AND EMPLOYERS'LIABILITY y ANY PROPRIETOR/PARTNER/EXECUTIVE E.L EACH ACCIDENT $1,000,000 B OFFICER/MEMBER EXCLUDED? N/A N 9298530 01/18/2024 01/18/2025 (Manclatory in NH) E.L DISEASE EA EMPLOYEE $1,000,000 If yes,describe under DESCRIPTION OF OPERATIONS below E.L DISEASE POLICY LIMIT $1,000,000 DESCRIPTION OF OPERATIONS I LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached if more space is required) CERTIFICATE HOLDER CANCELLATION 286-468-4 901 SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED �nLi oGE nc ayE gannK 938 KING ST BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN RYE BROOK, NY 10573-1226 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE - © 1988-2015 ACORD CORPORATION.All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD PORK Workers' CERTIFICATE OF STATE Compensation NYS WORKERS' COMPENSATION INSURANCE COVERAGE Board 1a.Legal Name 8 Address of Insured(use street address only) 1 b.Business Telephone Number of Insured (914)934-83U1 Arctic Mechanical Incorporated 286-468-4 460 N Main St Port Chester, NY 10573-3310 1 c.NYS Unemployment Insurance Employer Registration Number of Insured Work Location of Insured(Only required if coverage is specifically limited to 1 d.Federal Employer Identification Number of Insured or Social Security certain locations in New York State,i.e.,a Wrap-Up Policy) Number 06-1596446 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) Federated Reserve Insurance Company Village Of Rye Brook 3b.Policy Number of Entity Listed in Box"1 a" 938 King St 9298530 Rye Brook, NY 10573-1226 3c. Policy effective period n1 n 8/2021 to 01!18/2025 3d.The Proprietor, Partners or Executive Officers are 7X Included.(Only check box if all partners/officers included) all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box"Y insures the business referenced above in box"la"for workers' compensation under the New York State Workers' Compensation Law.(To use this form, New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". The insurance carrier must notify the above certificate holder and the Workers' Compensation Board within 10 days IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate. (These notices may be sent by regular mail.)Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent,or until the policy expiration date listed in box "3c",whichever is earlier. This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or alter the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note: Upon cancellation of the workers'compensation policy indicated on this form, if the business continues to be named on a permit, license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers' Compensation Law. Under penalty of perjury, I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Emily Petzel (Print name of authorized rereaentative or licensed agent of insurance carrier) Approved by: C' 12/05/2023 ( ignalure) (Date) Title: Authorized Representative Telephone Number of authorized representative or licensed agent of insurance carrier: 888-333-4949 Please Note: Only insurance carriers and their licensed agents are authorized to issue Form C-105.2. Insurance brokers are NOT authorized to issue it. C-105.2 (9-17) www,wcb.ny.gov