Loading...
HomeMy WebLinkAboutBP19-180GENERAL NOTES (AS APPLICABLE) DIVISION 1 - GENERAL CONDITIONS: DIVISION 8 - DOORS Ny D�a +S: CODES: ALL WORK & MATERIALS MUST CONFORM TO THE N.Y.S. UNIFORM FIRE PREVENTION & BUILDING CODE, LOCAL BUILDING CODES, NATIONAL BOARD OF FIRE UNDERWRITERS CODE AND TO THE REQUIREMENTS OF THE BOARD OF HEALTH & N.Y.S. ENERGY CONSERVATION CODE. OMISSION: ANYTHING NOT SPECIFICALLY SHOWN HEREON AND/OR SPECS, BUT WHICH IS REASONABLY IMPLIED, SHALL BE FURNISHED AS THOUGH SET FORTH IN THE PLANS AND/OR SPECIFICATIONS. ALL WRITTEN FIGURES, NOTES & DIMENSIONS ON THE FLOOR PLANS, OR SPECIFICATIONS SHALL TAKE PRECEDENCE OVER ANY DRAWN FIGURES. DO NOT SCALE PRINTS. ALL DIMENSIONS MUST BE VERIFIED IN THE FIELD BY THE CONTRACTOR BEFORE START OF CONSTRUCTION. ANY DISCREPANCIES ON THE PLANS, OR SPECIFICATIONS, MUST BE REPORTED TO THE ENGINEER PRIOR TO THE START OF CONSTRUCTION. MATERIALS. ALL MATERIALS SHALL BE NEW AND INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS. DIV1 6 - MOD & PLASTICS: LUMBER: ALL STRUCTURAL LUMBER SHALL HAVE A MINIMUM BENDING STRESS 3F 1,200 PSI. FRAMING: FRAMING SHALL BE ERECTED PLUMB, LEVEL, TRUE AND SECURELY NAILED. JOISTS, STUDS AND RAFTERS ARE TO BE DOUBLED AT ALL OPENINGS. ALL FLUSH JOIST HEADERS TO BE CONNECTED WITH GALVANIZED METAL JOIST HANGERS. ALL FLUSH BEAM CONNECTIONS SHALL HAVE HEAVY DUTY JOIST HANGERS. DOUBLE FRAME UNDER ALL PARTITIONS PARALLEL TO FRAMING. SIZES OF JOISTS AND RAFTERS ARE SHOWN ON THE PLAN. IF A WOOD DECK IS PROVIDED, ALL STRUCTURAL MEMBERS SHALL BE PRESSURE TREATED LUMBER. SHEATHING & SUBFLOOR: SHEATHING & SUBFLOOR SHALL BE APA ORIENTED STRAND BOARD WITH EXTERIOR GLUE AND NAILED TO EACH FRAMING MEMBER UNLESS OTHERWISE NOTED. JOIST HANGERS: JOIST HANGERS SHALL BE GALVANIZED STEEL OR IRON, SIZED TO AT THE SUPPORTED MEMBER AND OF SUFFICIENT STRENGTH TO DEVELOP THE FULL STRENGTH OF THE SUPPORTED MEMBER, AND FURNISHED COMPLETE WITH ANY SPECIAL FASTENERS REQUIRED. MANUFACTURES SHALL BE "SIMPSON" STRONG-11E, OR EQUAL DIVISION 7 - THERMAL & MOISTURE PROTECTION: ROOFING: ALL CHIMNEYS SHALL BE PROPERLY FLASHED WITH GALVANIZED STEP FLASHING. VALLEY AND VERTICAL ROOF SECTIONS SHALL BE PROPERLY SUPPORTED. ALL ROOFING SHALL BE INSTALLED IN STRICT CONFORMANCE TO THE MANUFACTURER'S SPECIFICATIONS. &--� TOP OF t W FLOOR E ,dr-� TOP OF FLOOR E 1" t 3 LILA y M BUILDING (PARTIAL) SECTION WINDOWS. ALL WINDOWS SHALL MEET THE MINIMUM REQUIREMENTS FOR LIGHT, VENTILATION AND EGRESS. ALL WINDOWS SHALL BE OF SUFFICIENT CONSTRUCTION SO AS TO MEET THE N.Y.S. ENERGY CONSERVATION CODE. INTERIOR DOORS: ALL INTERIOR DOORS SHALL COME COMPLETE WITH HARDWARE. A CLASS 'C' SELF -CLOSING ARE RATED DOOR SHALL BE FURNISHED AND INSTALLED BETWEEN GARAGE & HOUSE. ALL DOORS SHALL MEET THE MINIMUM REQUIREMENTS OF THE N.Y.S. ENERGY CONSERVATION CODE, IF APPLICABLE.. IRTIR9z"WaR;I DRYWALL: DRYWALL SHALL BE 1/2' GYPSUM BOARD SECURELY SCREWED ACCORDING TO THE MANUFACTURER'S SPECIFICATIONS. ALL JOINTS ARE TO BE TAPED AND SHALL RECEIVE (3) COATS OF JOINT COMPOUND. FINISHES TO BE SMOOTH, EVEN AND READY FOR PAINTING. DIVISION 16 - ELECTRICAL: ALL ELECTRICAL WORK SHALL BE DONE IN STRICT CONFORMANCE WITH THE NATIONAL BOARD OF FIRE UNDERWRITERS AND LOCAL CODES. THE SERVICE SIZE SHALL BE A MINIMUM OF 100 AMPS. PROVIDE SMOKE & CARBON MONOXIDE DETECTORS AS INDICATED ON FIRST FLOOR PLAN INTERCONNECTED 110 VOLT SMOKE DETECTOR W/ BATTERY BACKUP TESTED IN ACCORDANCE WITH UL217 & NFP INTERCONNECTED CARBON MONOXIDE ALARM (q W/ BATTERY BACKUP TESTED IN ACCORDANCE WITH UL 2034 & C -TO BE INSTALLED ON EACH FLOOR CONTAINING A SLEEPING ARE. OR CARBON MONOXIDE SOURCE. TO BE INSTALLED WITHIN 15 FEET OF EACH SLEEPING AREA SCALE: 3/16" = 1'—O" TABLE R301.2(1) CLIMATE AND GEOGRAPHIC DESIGN CRITERIA SNOW TOPOGRAPHIC SPECIAL WIND WIND—BORNE I DESIGN SPEED (mph) EFFECTS REGION DEBRIS ZONE ICATEGOR 30 115 MPH NO NO NO I B SECOND FLOOR (PARTIAL) PLAN FIRST FLOOR (PARTIAL) PLAN FLOOD HAZARDS MAY 2, 201 FREEZING I ANNUAL PERMIT cam' '. SCALE: 3/16" = 1'—O" NLLburl, SCALE: 3/16" = 1'—O" A Ld W w Q N +1 ti L3 C5 U 0 H 3 LnW 0 Lq >- LY_ Z <L #-- I0w Z C Q WtLI Z -j Cy Y ,D Ln H :3 < PCI LD L�J q 1 ® 1.4 -7 . 4 ON LD Z H ry Lil Lv Z .Z 5i [L Z z Pq Lli z w wQ Lj < _j ~<~L [3ri LLS iUi LD tY L� IL Z H <[ Lo Q ry La F-7 LJ 0 C) H CD <Q P aS K PARTIAL FLOOR PLANS & SECTION SCALEi AS NOTED PROTECT N❑. 19021 , Ex-