Loading...
HomeMy WebLinkAboutBP24-066PERMIT # A/ cz)7 �Q (O DATE: 7� �y p�(P; �% Q3 SECTION � © r/BLOCK 1LOT TYPE OF WORK % LDS .O / iC00 O/C1'/4 14 JOB LOCA ION / u�'1a�UC D42 OWNER % Q/I/e Q/l® CONTRACTOR, / B�EST. COST �o FEE 7 N/CO # FEE A Job DATE TCO # FEE DATE INSPECTION RECORD DATE FOOTI N G FOUNDATION FRAMING RGH FRAMING INSULATION PLUMBING RGH PLUMBING GAS 0 SPRINKLER ELECTRIC LOW -VOLT IO ALARM 0 AS BUILT FINAL IN3P OTHER A FROVALS ) Oa BOT PB ZBA OTHER (QyE BRnv�A VILLAGE OF RYE BROOK MAYOR 938 King Street, Rye Brook,N.Y. 10573 ADMINISTRATOR Jason A. Klein (914) 939-0668 Christopher J. Bradbury www.ryebrookny.gov TRUSTEES BUILDING& FIRE INSPECTOR Susan R. Epstein Steven E. Fews Stephanie J. Fischer David M. Heiser Salvatore W. Morlino CERTIFICATE OF COMPLIANCE August 23,2024 Daniel Albano& Felicia Albano 57 Tamarack Road Rye Brook,New York 10573 Re: 57 Tamarack Road, Rye Brook,New York 10573 Parcel ID#: 135.60-1-17 Building Permit#24-066 issued on 4/23/2024 for a Rooftop Solar Array This certifies that the rooftop solar array,installed under the above captioned permit has been satisfactorily completed. Sincerely, Steven E. Fews Building&Fire Inspector /to For office use onh•: BUILDWG DEPARTMENT PERA1TT# JUL 2 2 2024 VIL -1GE.OF RYE BROOK ISSLED: 938 KL�G STRE �� YE BRoox, tw YoRK 10573 DATE: `7-Q4-80 VILLAGE OF RYE BROOK ] 9 -06 -' FEE: 9 oh — R DW BUILDING DEPARTMENT APPLICATION FOR CERTIFICATE OF OCCUPANCY,CERTIFICATE OF C•O�IPLIANNCE, AND CERTIFICATION OF FLNAL COSTS TO BE SUBMITTED ONLY UPON COMPLETION OF ALL WORK, AND PRIOR TO THE FINAL INSPECTION Address: S—( �� k Q Q . Occupancy Use: Parcel ID #: (an - L 1-7 Zone:./9--7 Owner: A:� pAddress: -5 1 P.E.R.A. or Contractor: �� (y C'�_ i�6L== 'A Aress: 'S-IS t Person in responsible charge: Address: S J 5 Cow ( cl r . 0-141 Application is hereby made and submitted to the Building Inspector of the Village of Rye Brook for the issuance of ac�10 Certificate of Occupancy Certificate of Compliance for the structure construction alteration herein mentioned in accordance with law: STATE OF NEW YORK_ COUNTY OF WESTCHESTER as: YZ\ (�S&VkWr ng duly swom,deposes and say_•s that he she resides at (rnPrint Name of.Applicant) (No.and Street) in I, 1 1�'� in the Comm_-of 11 in the State of :that (City Tm n Village) he:she has supen-ised the work at the location indicated above,and that the actual total cost of the work,including all site improvements: labor:materials:scaffolding:fixed equipment:professional fees.and including the monetary value of any materials and labor which may have been donated gratis was:S for the construction or alteration of: Deponent further states that he she has examined the approved plans of the structure.work herein referred to for which a Certificate of Occupancy Compliance is sought,and that to the best of his her knowledge and belief,the structure work has been erected completed in accordance with the approved plans and any amendments thereto except in so far as variations therefore have been legally authorized:and as erected completed complies with the laws governing building construction.Deponent further understands that it shall be unlawful for an owner to use or permit the use of any building or premises or part thereof hereafter created:erected_changed:converted or enlarged:vk-holly or partly,in its use or structure until a Certificate of Occupancy or Certificate of Compliance shall have been duly issued by the Building Inspector as per§2 0-10.A. of the Code of the Village of Rye Brook. SNvorn to before me this Sworn to before me this kc day of ,,y�-� 20 2L day of . 20--2-4 SigiiaiCre of Propem•Onner JtOTARY JACLYN M SGRO Signature of applicant No 0S ATE OF 8WYON( gf+.�C) Qualibad In Orange CountytyPrint Name of(P�r�opem OnnerCommisaiont Ex Irea 11/ 2026 Prmt'�ame ofApplicaat 01 Yrr/I) N Public an•Pub �yE BRC�k, O�` tim 1932 BUILDING DEPARTMENT ❑ UILDING INSPECTOR [ASSISTANT BUILDING INSPECTOR VILLAGE OF RYE BROOK ❑CODE ENFORCEMENT OFFICER 938 KING STREET • RYE BROOK,NY 10573 (914) 939-0668 FAx (914) 939-5801 www ryebrook.org - - - - - - - - - - - - - - - - - - - - INSPECTION REPORT - - - - - - - - - - - - - - - - - - - - ADDRESS: J /Y) ,4 IZ A C-)L R O CA � DATE: J ' , 7 o Z`� PERMIT# Z Li _ b ISSUED: /"z3�2 SECT: I '60 BLOCK: LOT: 12 LOCATION: 1\O� } e ,•� { h ►off OCCUPANCY: ❑ VIOLATION NOTED THE WORK IS... El ACCEPTED ❑ REJECTED/ REINSPECTION ❑ SITE INSPECTION REQUIRED ❑ FOOTING ❑ FOOTING DRAINAGE ❑ FOUNDATION ❑ UNDERGROUND PLUMBING NOTES ON INSPECTION: ❑ ROUGH PLUMBING ❑ ROUGH FRAMING ❑ INSULATION i ❑ NATURAL GAS ICJ l- fv D 1-6 ❑ L.P. GAS ❑ FUEL TANK ❑ FIRE SPRINKLER ❑ FINAL PLUMBING ❑ CROSS CONNECTION FINAL .❑ OTHER �J� ��- _ r � 3 O p G � a� w N en tV rr4-4 a Vi w a"p O W a-+ a v dam' v� a. 41 O- U r 1 4 p ea v 0 (3� bA ►r� !� Ln GA b V. w G W en M O Z `n �0 bi) (n i�I ✓ 14 F I�1 O Lin ;L4O W to l— W °I ' w C/) Cc, O A u O a O ( � � c �/ � w 1�-I W IIF+��111 Uj O V oa W w a o v ' 4 ] O 0o N u . r� co C w � V �-{ O O N z V z a o F r �••� O �.{ O cn d' �W.i W cw7 v� -o Q R �' +at u cn- 0*4 14 CA - Ctl •� 0 � � r 44 W 44 Cl) W F Q Z 1a 14 a U ° 1-4 U U VU Q a w Q z x N ° d :" c A W z d oA � E04 •• U + x � � -� O BUILQRVE MENT D p VI OOK 938 KiNO ,NY 10573 MAR - 8 2024 VILLAGE OF RYE BROOK BUILDING DEPARTMENT FOR OFFICE USE ONLY: L� 010 Approval Date: APR 2 2 2024 1' t Application# A"4—oDb Approval Signature: ARCHITECTURAL REVIEW BOARD: Disapproved: : Date: BOT Approval Date: Case# : Chairman: PB Approval Date: Case# Secretary: ZBA Approval Date: Case Other: / Application Fee: Permit Fees:,`,`_©'() APPLICATION TO INSTALL PHOTOVOLTAIC SOLAR ARRAY Application dated:r�'d is hereby made to the Building Inspector of the Village of Rye Brook NY.for the issuance of a Permit for the installation of a Photovoltaic Solar Array as per detailed statement described below. 1. Job Address: 57 Tamarack Road, Port Chester, NY 10573 SBL: 135.60-1-17 Zone: R-7 2 Type,kW&Location of Array,(use additional sheets ifnecessarN is installation of 33 rooftop solar panels (13.530k1M 3.Property Owner: Dan Albano Address: 57 Tamarack Road, Port Chester, NY 10573 Phone# (610) 306-2359 Cell# e-mail albano353@gmail.com 4.Applicant: Infinity Solar Systems Address:575 Corporate Drive Suite 2200,Mahwah,NJ 07430 Phg.ne#845-474-0075 Cell# e-mail permitting@infinitysolarsystems.com 5. Design Engineer: Mike Miele Address:705 Orrs Mills Road, New Windsor, NY 12553 Phone# 845-629-9693 Cell# e-mail mmielepeMyahoo.eom 6.Solar Contractor:Infinity Solar Systems Address:575 Corporate Drive Suite 2200,Mahwah;NJ 07430 Phone# 645-474-0075 Cell# e-mail permitting@infinitysolarsystems.com 7. Occupancy:(I-Fam., -Fam.Commercial.etc )Pre-construction: Residential Post-construction:No changes proposed 8. If building is located on a comer lot,which street does it front on: 9. N.Y.State Construction Classification: N.Y. State Use Classification: 10. Construction Type&Location:( )Typical Western Lumber Frame;( )Timber Frame[TC];( )Wood Truss[TT]; ( )Pre-engineered wood[PW];Located;( )Floor Framing IF];O Roof Framing[RI;O Floor& Roof Framing[FR];Other: 11. Number of stories: Roof Style:(hip,shed.mansard.etc ) 12, Will a New Roof Be Installed: No f✓J Yes ❑ (a separate roofing permit is required to re-roof an existing building) 13. Roofing Material&Number of Layers: ) 8n 2/2021 14. Will the proposed project disturb 400 sq.ft.or more of land,or create 400 sq,ft.or more of impervious coverage requiring a Stormwater Management Control Permit as per§217 of Village Code? No: d Yes: ❑ Area: 15. Will the proposed project require a Site Plan Review by the Village Planning Board as per§209 of Village Code? No: 0 Yes: ❑ (if yes,applicant must submit a Site Plan Application.&provide detailed drawings) 16. Will the proposed project require a Tree Removal Permit as per§235 of Village Code?No: 10 Yes: ❑ (11 N es.applicant must submit a Tree Removal Permit Application) 17. Does the proposed project involve a Home-Occupation as per§250-38 of Village Code? No: V Yes: ❑ Indicate:TIER 1: TIER 11: TIER III: (if ces a Home Occupation Permit Application is required) 18. What is the total estimated cost of construction: $ 36,000.00 (Note The estimated cost shall include all site improvements,labor,material,scatfolding.fixed equipment,professional fees,including any material and labor which may be donated gratis If the final cost exceeds the estimated cost,an additional tee will be required prior to issuance orthe C/O). 19. start Date. about 2 weeks after permit issued Completion Date: 2 days(weather permitting) This application must bear the notarized signature(s) of the legal owner(s) of the subject property, and the applicant of record in the spaces provided. Any application not properly completed in its entirety and/or not properly signed shall be deemed null and void and will be returned to the applicant. Please note that application STATE OF NEW YORK..COUNTY OF WESTCHESTER ) as: 1, Jan Bergus - Infinity Solar Systems ,being duly sworn,deposes and states that he/she is the applicant above named, (prat mime or ndn idual signing as the applicantl and further states that(s)he is the legal owner of the property to which this application pertains,or that(s)he is the, contractor for the legal owner and is duly authorized to make and file this application. /indicate architect contractor,agent.attornec.etc I That all statements contained herein are true to the best of his/her knowledge and belief,and that any work performed,or use conducted at the above captioned property will be in conformance with the details as set forth and contained in this application and in any accompanying approved plans and specifications,as well as in accordance with the New York State Uniform Fire Prevention& Building Code,the Code of the Village of Rye Brook and all other applicable laws,ordinances and regulations. Sworn to before me this S Sworn to before me this T day of �Ah,A 20 11 day of M 6,A ,20L_ ary Notan P11_00n� nit Solar Systems 5 nature erty Owner ienat�A'A Dan Albano Jan Bergus - Infinity Solar Systems Print Name of Property Owner Print Name of Applicant hf07ARY PlJ13LIC,STATE OF NEW YORK -..— JACLYN Wi SGRO No.01 SG6315056 NOTARY PUBLIC,STATE OF NEW YORK Qualified in Orange Courriyy 2 No.O1SG6315056 M Commisyioe3 Expires 11I17F2026 Qualified in Orange Countyty Soy Commission Expires 11/17!`2026 8/12/2021 , 00 4 h+i et d Q r� U w r F ' Z w L r- 00 0 O : to a o D xy r Z a cn F O Q O r ^ w No �I g � ■ z o O A LfMM Ln a O0 00 Ln s �i 1--� ►�-1 O �i M"'y w O e 44 �I W z w FH O = A � F O w 5 0 o ' Z o W z c _ z to N Z ■ ■ Z V) � Fr'+ u a o O A Q P.m w '" lt My � � x r 1 FMMB+ 00 � ►z� � � W � � vi N U �1 Fil �1 a c� A I p; w Ci ■ R+ r W Vr. m z lZ W A 0 v $ R� 04 04 Z H w p CAz w w o x 08 F j.., c.� W Z a W 1 Z w 0 z A 0 a z w P. �I a a z w a°c � r r a f r f f a a f e f f f f a e a s ■ a , e a f a t e : a a a �aI a a a a a a f a ew — - JD - BUIENT MAR 15 2024 VIOK 938 KIN NY 10573 VILLAGE OF RYE BROOK BUILDING DEPARTMENT ELECTRICAL PERMIT APPLICATION Westchester County fMaster /Electricians License Required FOR OFFICE USE ONLY BP#: ��`7 !OC(JC� EP#: Approval Date: APR2 9 AM9 A Permit Fee: $ Approval Signature: Other: Disapproved: (fees are non-refundable) Application dated, is hereby made to the Building Inspector of the Village of Rye Brook NY,for the issuance of a Permit to install and/or remove electrical equipment, wiring, fixtures,or to perform other high or low voltage electrical work as per the detailed statement described below. The applicant & property owner, by signing this document agree that all electrical work performed will be in conformance with all applicable Federal.State,County and Local Codes. I.Address: 57 Tamarack Rd,iQyC ,&kbgKNY 10573 SBL: 135.60-1-17 Zone: R-7 2.Property Owner:Dan Albano Address: 57 Tamarack Rd, 2 yc aAak4Y 10573 Phone#: (610) 306-2359 Cell#: email: albano353@gmail.eom 3.Master Electrician:Jason Monforte- Infinity Solar SystemsAddress:575 Corporate Drive Suite 2200, Mahwah, NJ 07430 Lic.#: 1911 Phone#: 845-474-0075 Cell #: email:permitting(Minfinitysolarsystems.eom Company Name:Infinity Solar Systems Address: 575 Corporate Drive Suite 2200, Mahwah, NJ 07430 4.Proposed Electrical Work/Fixture count: installation of 33 rooftop solar panels(13.530M) STATE OF NEW YORK,COUNTY OF WESTCHESTER ) as: Jason Monforte-Infinity Solar Systems being duly swom.deposes and states that he/she is the applicant above named.and does further (print name of individual signing as the appl scant 1 state that(s)he is the legal owner of the property to which this application pertains.or that(s)he is the contractor for the legal owner and is duh authorized to make and file this application. (indicate architect.contractor.agent.attorney.etc i The undersigned further states that all statements contained herein are true to the best of his/her knowledge and belief.and that any work performed.or use conducted at the abo\c captioned properth will be in conformance with the details as set forth and contained in this application and in any accompam ing approved plans and specifications.as well as in accordance with the New York State Uniform Fire Pre\ention&Building Code.the Code of the Village of R\a Brook and all other applicable laws,ordinances and regulations. Swo b fore me this U Sworn to fore me this 5- d .20 / day of 20 g to roperty Owner T Signature of Applicant Dan Albano Jason Monforte - Infinity Solar Systems Print NVL_ of Property Owner Print Name o pplicant ll Nota P lic JACLr tv;✓SG 0 Notary Pub1 _ NOTARY PUBLIC,STATE OF NEW YORK JA L`.'tv ✓SGRO No.01 SG6315056 NOTARY STATE OF NEW PORK I Qualified in Orange County No.01SG6315056 yy My Commission Expires 11/17/2026 M CO mission Exed in piQualires fres 11117/2026 8/12/2021 STATE WIDE INSPECTION SERVICES, INC. 0•0 • • SWIS JOB APPLICATION tel 845.202.72240. • Office Use Elect. Permit# —7 Date Bldg Permit# ,�/Jr�y— Scl Ft Plumbing Permit# Final Certificate # City/Village Zip Building Dept. �_ County Address 5-7 ' `K ILo� ( Cross Street �< C `j I c section 13S I Block Lot r Owner Name/Address(If different than above) ' Contact Number bl 0 3 Db- 23 51-el ❑Basement ❑ Ist Fl. ❑ 2nd Fl. ❑3rd Fl. ❑More Than 3 Fl. ❑Garage ❑Attic ❑Outside ❑Residential ❑Commercial Receptacles Special Recept GFCI AFCI Switches Dimmers Smoke Alarms C/0 Detector Hood Trash Compact Amt Amps Range(s) Cooktop(s) Oven(s) Dishwashers Refrigerator Disposal Microwave Luminaires Generator Transfer Switch SERVICE Amperage #Panels IP 3P # Meters # Disconnect ❑Underground ❑ New ❑ Reconnect ❑ Repair ❑Overhead ❑ Upgrade ❑ Disconnect Utility ID# ❑Con Ed ❑ NYSEG ❑Central Hudson ❑ Orange/Rockland PHOTOVOLTAIC SYSTEM PV Modules Inverters AC Disconnect Junction Box Combiner Box Load Center PV Monitor Energy Storage System DC Disconnect ❑Legalization ❑ Safety Inspection ❑Consultation 33 ftop Soler fk,nclS f 13,530"� I)IZSI� Cow��j,her �Y�` I)WA A t scohnec+ , � ►VAoV14�1 1) sys�e p RICF�VE DD ` MAR 15 2024 -] VILLAGE OF RYE BROOK BUILDING DEPARTMENT This application is valid for one(1)year from the date received by SWIS.This application is intended to cover the above listed items to be inspected,if at any time of inspection additional items have been installed,you are authorized to make the inspection and adjust the fee for the additional items inspected.The applicant declares that there is no open applications for the above address with any other inspection company.The applicant, owner or authorized agent agrees to all the above terms and conditions as set forth for the application. Email Address IVASPe-L�O-SfCh , c,r C tt Name J1150"A M0-417rtE License# 19/1 Date ?/ Zy Signature / ;/I Address D S�e 22>o City/State Zip Code l 7S Cor Gee � .r �.wc►,, JVT- p ��7 13v Company Phone# rq S _ Lh'-I- ONO Mi State Wide Inspection Services � � 1 Main Street MAY — 9 2024 Fishkihkill, NY 12524 s w u A, 845 202-7224 Phone 914-219-1062 Fax STATEWIDE INSPECTION SERVICES VILLAGE OF RYE BROOK Email: officeCcbswisnv.com BUILDING DEPARTMENT Website: www.swisny.com Service With Integrity BY THIS CERTIFICATE OF COMPLIANCE STATE WIDE INSPECTION SERVICES CERTIFIES THAT: Upon the application of: Upon Premises Owned by: Infinity Solar Systems Daniel &Felicia Albano Murphy Panagiotau 57 Tamarack Road 575 Corporate Drive,Suite 2200 Rye Brook, NY 10573 Mahwah, NJ 07430 Located at: 57 Tamarack Road, Rye Brook, NY 10573 Section: Block: Lot: Electrical Permit Number: EP 24-087 135.60 1 17 Certificate Number:2024-2978 Building Permit Number: BP 24-066 A visual inspection of the electrical system was conducted at the Residential occupancy described below.The electrical system consisting of electrical devices and wiring is located in/on the premises at: 57 Tamarack Road, Rye Brook, NY 10573 The Photovoltaic System was inspected in accordance with the NYS and NFPA 70-2017 and the detail of the installation,as set forth below,was found to be in compliance on the 91'Day of May 2024. Name Quantity Rating Circuit Type PV Modules 33 Microinverters 33 Combiner Panel 01 125 Amp Disconnect 01 60 Amp Monitoring System 01 Officer: Frank 1. Farina This certificate may not be altered in any way and is validated only by the presence of a seal at the location indicated,This certificate is valid for work performed on the date of inspection only. Michael E . Miele, PE ------ Licensed Professional EngineerUL 2 2 2A24 Licensed In New York, New Jersey, Connecticut & California JUL — New York License # 079676 VILLAGE OF RYE BROOK New Jersey License # 44042 BUILDING DEPARTMENT Connecticut License # 23158 California License # 31508 July 18, 2024 Village of Rye Brook The Office of the Building Inspector 938 King Street Rye Brook, NY 10573 Re: Dan Albano-57 Tamarack Rd. Rye Brook, NY 10573 Single Family Residence, Solar Panel Installation Certification Village of Rye Brook. County of Westchester, State of New York Dear Building Department, I have reviewed the solar energy system installation at the subject address.The system has been installed in accordance with the manufacturer's installation instructions and the approved construction drawing. I have determined that the installation meets all building code requirements and is certified as for all code and approved plans for the Village of Rye Brook. I can hereby certify that the installation complies with the 2020 New York State Residential Building Code and all applicable codes and design loads as referenced on the approved plans, including ASCE 7-16 (Minimum Design Loads and Associated Criteria for Buildings and Other Structures). If you have any questions, please feel free to call me at any time. Thanks, in advance. Sincerely Yours, Of NEW PP�� E0 W 4.9 09¢ r 1 m W Z .Ra..•�FOA 079616 4 � Michael E. Miele, PE %FESStONP� 705 Orrs Mills Road, New Windsor, NY 12553 ♦ Phone 845.629.9693 ♦ MikeMielePE@gmaii.com Michael E. Miele, PE D Licensed Professional Engineer MAR -8 2024 ID Licensed In New York, New Jersey, Connecticut& California New York License#079676New VILLAGE OF RYE BROOK Connecticutsey License # 315 BUILDING DEPARTMENT Connecticut License#23158 California License#31508 February 9, 2024 Village of Rye Brook Building Department The Office of the Building Inspector 938 King St. Rye Brook, NY 10573 Re: Dan Albano-57 Tamarack Road, Rye Brook, NY 10573 Single Family Residence,Solar Panel Loadinp Certification Villal;e of Rye Brook,County of Westchester, State of New York Dear Building Department I am the engineer of record for the above referenced project. I have prepared the attached plans dated February 9, 2024 that consist of the installation of(33)SEG-410-BMD-HV solar panels at the above referenced location. I can hereby certify that the existing roof structure combined with the additional weight of the solar panels meets the requirements of The 2020 Residential Code of New York State, Publication Date, November 2019. The design loads were as follows, Roof Design Load: 30psf live load Wind Design Load: 115mph No additional structural members were required. The roof is currently framed with 2x10 wood framing @ 16" O.C. The roof structural members are in compliance with ASCE 7-16 for deflection and acceptable bending stress. If you have any questions, please feel free to call me at any time.Thanks in advance. Sincerely Yours, �OF NEpy 10 QP�"�EOWq,9O 09� YI /000to 0 .* c? n S! A 1; * r 2 1 f m A I W Michael E. Miele, PE Z�F10 079676 A%'-ESso0 ' 705 Orrs Mills Rd., New Windsor NY 12553 ♦ Phone: 845.629.9693 ♦ mmielepe@yahoo.com Michael E. Miele, PE Licensed Professional Engineer Licensed In New York, New Jersey, Connecticut& California New York License#079676 New Jersey License#44042 Connecticut License#23158 California License#31508 February 9, 2024 Village of Rye Brook Building Department The Office of the Building Inspector 938 King St. Rye Brook, NY 10573 Re: Dan Albano- 57 Tamarack Road, Rye Brook, NY 10573 Single Family Residence,Solar Panel Loading Certification Village of Rye Brook,County of Westchester, State of New York Dear Building Department I am the engineer of record for the above referenced project. I have prepared the attached plans dated February 9, 2024 that consist of the installation of(33)SEG-410-BMD-HV solar panels at the above referenced location. I can hereby certify that the existing roof structure combined with the additional weight of the solar panels meets the requirements of The 2020 Residential Code of New York State, Publication Date, November 2019. The design loads were as follows, Roof Design Load: 30psf live load Wind Design Load: 115mph No additional structural members were required. The roof is currently framed with 2x10 wood framing @ 16" O.C. The roof structural members are in compliance with ASCE 7-16 for deflection and acceptable bending stress. If you have any questions, please feel free to call me at any time. Thanks in advance. Sincerely Yours, OF NEby 1 �PQk�'EDWA90 09'� r 1 rn W • Michael E. Miele, PE 2�F0 079616 A%'-ESsvO ' 705 Orrs Mills Rd., New Windsor NY 12553 ♦ Phone:845.629.9693 ♦ mmielepe@yahoo.com Michael E. Miele, PE Licensed Professional Engineer Licensed In New York, New Jersey, Connecticut &California New York License#079676 New Jersey License#44042 Connecticut License#23158 California License#31508 February 9, 2024 Village of Rye Brook Building Department The Office of the Building Inspector 938 King St. Rye Brook, NY 10573 Re: Dan Albano- 57 Tamarack Road, Rye Brook, NY 10573 Single Family Residence,Solar Panel Loading Certification Village of Rye Brook, County of Westchester,State of New York Dear Building Department I am the engineer of record for the above referenced project. I have prepared the attached plans dated February 9, 2024 that consist of the installation of(33)SEG-410-BMD-HV solar panels at the above referenced location. I can hereby certify that the existing roof structure combined with the additional weight of the solar panels meets the requirements of The 2020 Residential Code of New York State, Publication Date, November 2019. The design loads were as follows, Roof Design Load: 30psf live load Wind Design Load: 115mph No additional structural members were required. The roof is currently framed with 2x10 wood framing @ 16" O.C. The roof structural members are in compliance with ASCE 7-16 for deflection and acceptable bending stress. If you have any questions, please feel free to call me at any time. Thanks in advance. Sincerely Yours, OF NEW Y �QP��EDWg9O O9� ytot/o-'/0�lt r 1 m W m . . I � 2 Michael E. Miele, PE CFO 07967f A9OFESS04N ' 705 Orrs Mills Rd., New Windsor NY 12553 ♦ Phone: 845.629.9693 ♦ mmielepe@yahoo.com Aurora Shade Report Customer Designer Organization Da, al''-.1� -- 1,i Debei Infinity Solar Systems Address Coordinates Date January2024 _ - i Annual irradiance kWh/m2/year 2,450 or more 2,100 3 1,750 2 _ _ — 1,400 1,050 700 350 0 a Summary Array Panel Count Azimuth(deg.) Pitch(deg.) Annual TOF(`.) Annual Solar Access(°o) Annual TSRF(%) Weighted average by panel count powered by aurora Customer Designer Organization Dan Albano Uri Lieber Infinity Solar Systems Address Coordinates Date 57 Tamarack Road (41,015117.-73 678805 i 25 January-2024 Rye Brook.New York 10573 Monthly solar access(%)across arrays Array Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 65 65 76 °^ 94 93 93 93 82 68 63 65 _ 5 6C 86 89 89 90 89 6- 53 55 63 85 84 92 - 88 89 92 98 76 77 85 6: 62 62 64 64 62 65 65 63 61 79 1 9 82 86 91 91 85 ;;4 -� -1 '1 69 72 2/4 powered by ;:� aurora Customer Designer Organization Dan Albano Uri Lieber Infinity Solar Systems Address Coordinates Date 57 Tamarack Road 1 5117 6788u5 25 January 2024 Rye Brook,New York 10573 Zoomed out satellite view 3D model l At. �t3 3D model with LIDAR overlay 58 ft E f. M 4 powered by aurora Customer Designer Organization Dan Albano Uri Lieber Infinity Solar Systems Address Coordinates Date 57 Tamarack Road (41.01 511 7.-73-578R05 25 January 2024 Rye Brook.New York 10573 Street view and corresponding 3D model C 2024 Google Uri Lieber 4 powered by aurora D UMWIE MAR - $ 3D Infinity Solar Systems,LLC j — I n F i n i t y E n e rg 2U24 75 Corporate Dr.,Suite 2200 \� VILLAGE OF RYE BROOK Mahwah,NJ 07430v.infinit<�solars stems.com BUILDING DEPARTMENT Limited Authorization and Release I Daniel Albano ("Property Owner"), authorize Infinity Solar Systems, LLC, a limited liability company with its principal place of business located at 575 Corporate Dr., Suite 2200 Mahwah,NJ 07430 including any and all of its agents, assigns, and delegates (collectively "Infinity") as my Agent ("Agent") to act for me as authorized herein with respect to the application and permitting process associated with the successful interconnection of a solar photovoltaic system ("Solar System") to be installed at and affixed to my residence. I am the owner of my residence, which is the property located at the following address: 57 Tamarack Road, Rye Brook New York, 10573 (the "Property"), and hereby authorize my Agent to obtain my account information for the twelve (12)months preceding the date first set forth below, including electrical usage and demand history. Upon receipt of said information, Agent agrees to keep this information confidential and to use same only for the purposes of designing and installing the Solar System Agent agrees to keep any and all information that I provide pursuant to this Limited Authorization and Release confidential and use it only for the purposes of. designing and installing my Solar System; obtaining state rebate and/or SREC funding incentives on my behalf, establishing utility interconnection agreements, proper metering, and approvals; and/or completing and submitting applications for Building Permit(s) and/or Zoning Permits(s) in (circle one): Town of Deerpark Town of New Windsor Village of Monroe Village of Port Chester** Town of Hamptonburgh Town of Wallkill Village of Warwick **Village Owner Consent Town of Highlands Village of Florida Village of Washingtonville Form also attached PLEASE INITL4L AND SIGN THE FOLLOWING PAGE 1 Infinity Solar Systems,LLC n f i n i t y E n e r g V 575 Corporate Dr.,Suite 2200 Mahwah,NJ 07430 www.infinitysolarsystems.com I certify to my Agent the following with the intention that my Agent shall rely upon these representations in exercising the powers herein conferred. I hereby give the Agent the power to engage in transactions for me in any way that I could act for myself with respect to the following matters: Check all that apply: I r l To exercise or perform any act, power, duty, right, or obligation that I now have, or may subsequently have, as the applicant, lessor, or owner of the Solar System in connection with, arising from or relating to the Application for a Building Permit or Zoning Permit in the TownNillage in which the Property is located, as my Agent, and the preparation, review, and execution of all documents reasonable or necessary in connection therewith. I r l To exercise or perform any act, power, duty, right, or obligation that I now have,or may subsequently have,as the applicant, lessor or owner in connection with, arising from or relating to any documents required by the County of: Rockland, Orange Westchester, Dutchess, Putnam, Sullivan, or Ulster, in the State of New York including the preparation, review, and execution of all documents reasonable or necessary in connection therewith. ✓� To execute and deliver any and all such documents as may be reasonable or necessary to effectuate the proper system design,permitting,and installation of the Solar System. By signing below, I acknowledge that I have received a copy of this Limited Authorization and Release, and I understand its terms this 30th day of Jan,2024 vak6dOrako- INFINITY SOLAR SYSTEMS,LLC Signature of Property Owner By: Ali Daniel Albano Name: Andy 4trauss Name of Property Owner 01/30/2024 Date Name of accountholder on Utility Bill(if different from above) 2 GN Signature Certificate Reference number YA5GK-R3BDB-HVRUC-BIVWU Signer Timestamp Signature Andy Strauss Email andy.s@infinitysolarsystems.com nSent 31 Jan 2024 20:46:02 UTC \ 1/�/, sViewed. 31 Jan 2024 20:46:02 UTC &4W� v u'/i[/J J Signed 31 Jan 2024 20:46:24 UTC Recipient Verification: IP address 72.87.65.107 i Email verified 31 Jan 2024 20:46:10 UTC Location West Kingston,United States Daniel Albano Email albano353@gmail.com Sent 31 Jan 2024 20:46:37 UTC nnw n/Omo- Viewed 31 Jan 2024 20:46:37 UTC LV1 (Xj(i Signed 31 Jan 2024 20:48:20 UTC Recipient Verification: IP address:172.226.196A46 .,Email verified 31 Jan 2024 20 46 37 UTC Location:Queens,United States Documeni completed bl all parties on 31 Jan 2024 20A&20 UTC Page 1 of 1 Signed with PandaDoc 0. 0 PandaDoc is a document workflow and certified eSignature solution trusted by 50.000+companies worldwide. [Mill Building Permit Check List&Zoning Analysis Address: C�lY1C k �_Q 0(_ �� SBL• 1?D5. Zone: Use: `D Const.Type: Other. Submittal Date Revisions Submittal Dates: Applicant: Nature of Work Reviews:ZBA: %A Z P& BOT: Other. NEED OK t'� 1� 0 (� (` FEES:Filing: P: Flood Plane: Legalization: ( ) ( �IAPP: Dated: v Notarize& Truss I.D. Cross Connection: H.O.A.: ( ) ( ) Scenic Roads: Steep Slopes: Wetlands: Storm Water Review: Street Opening. ( ) ( ) ENVIRO:Long Short Fees: N/A: ( ) ( ) SITE PLAN:Topo: Site Protection: S/W Mgmt.: Tree Plan: Other. ( ) ( ) SURVEY:Date& Current ArchivaL Sealed:. Unacceptable: ( ) ( ) PLANS:DaterStampe& Sealed- Copies Electronic: Other. License: ,�/ Workers Comp: ✓ Liability Tmp.Waiver: Other. ( ) ( ) CODE 753#: Date& N/A: (� (J�HIGH-VOLTAGE ELECTRICAL Plans: Permit: N/A: Other: ( ) ( ) LOW-VOLTAGE ELECTRICAL:Plans: Permit N/A: Other. FIRE ALARM/SMOKE DETECTORS Plans: Permit: H.W.I.C.:_Battery:_Other. ( ) ( ) PLUMBING Plans: Permit Nat.Gas: LP Gas: N/A/: Other: ( ) ( ) FIRE SUPPRESSION:Plans: Perms N/A Other: ( ) ( ) H.V.A.C.: Plans: Pew N/A: Other.. ( ) ( ) FUEL TANK:Plans: Permit Fuel Type: Other. ( ) ( ) 2020 NY State ECCC: N/A: Other. ( ) ( ) Final Survey Final Topo: RAPE Sign-off Letter. As-Built Plans: Other. ( ) ( ) BP DENIAL LETTER: C/O DENIAL LETTER: Other. ( ) ( ) Other. (gyARB mtg.date: l 2 approvaL• 4 ` 17 - Z`i notes: ( )ZBA mtg.date: approvaL• notes: ( )PB mtg.date: approvaL• notes: AmpsA REQUIRED EXISTING PROPOSED NOTES Daft, A 2 rea 2 7014 A • Circle: Fla Front: Front: Sides: Rear. Main Cov Accs.Cov. Ft.H Sb: Sd.H Sb: GFA: Tot. mp: Ft PP Height/Stories notes: Bt ILD, fi MENT VIL OF RY OOK MAR 18 2024 938 KING ET Rti'E BR ,NY 10573 4) 9_-0 VILLAGE OF RYE BROOK �� of BUILDING DEPARTMENT s►rt»rt»►»t►rrrt»rtrtrt►►►rrt»►►r►rt»*rt►*rt»»►►+rt»rtrt►►►►tsstsssssstst►►rt►r*►►►►►rrtrt»»►►►rrtrt4srrrrrrt**►►*►»►*»*►►►rt►t ARCHITECTURAL REVIEW BOARD CHECK LIST FOR APPLICANTS This form must be completed and signed by the applicant of record and a copy shall be submitted to the Building Department prior to attending the ARB meeting. Applicants failing to submit a copy of this check list will be removed from the ARB agenda. Job Address: 57 Tamarack Road. Port Chester. NY 10573 [)ate of Submisssion: Parcel ID#: 135.60-1-17 Zone: R-7 Proposed Improvement(Describe in detail): installation of 33 rooftop solar panels (13.530kW) APPLICANT CHECK LIST: - MIST BE COMPLETEI) BY THE APPLICANT The following items must be submitted to the Building Department by the applicant-no exceptions. Pro erty 0%%ner: Dan Albano l. I�j Completed Application p Two('_)sets of sealed plans. Address:57 Tamarack Road, Port Chester, NY 10573 . (610) 306-2359 ti✓I Two(2)copies of the propem survey. Phone r (l/)T%%o(_)copies of the proposed site plan. Applicant appearing before the Board: 5. A One electronic-disc copy of the complete Infinity Solar Systems application materials. 6. (�)Filing Fee. Address: 575 Corporate Drive Suite 2200, Mahwah, NJ 07430 7. (/)Any supporting documentation. Phone 845-474-0075 8. 1 �)HOA approval letter. itfappGcable) 9. ( Photographs. Architect Engineer:Mike Miele 10.1 Samples of finishes color chart. (a sample hoard or model mat be presented the night of the meenng� Phone -, 845-629-9693 By signature below, the owner/applicant acknowledges that he/she has read the complete Building Permit Instructions & Procedures, and that their application is complete in all respects. The Board of Review reserves the right to refuse to hear any application not meeting the requirements contained herein. Sworn to before me this S Swom to before me this S day 20 L day of ,`A e 3(►�� Solar S stems Srgna ure P , rt ()\cnri A-�inity t Dan Albano Jan Bergus - Infinity Solar Systems Print Nam-of Propert% 0"ner r Print Name Applicant - '_ A- t/ Notan Pr lir Notan Pu c JACLY14 M SGRO jA N M SGRO NOTARY RRX.STATE OF NEW YORK NOTARY ,STATE OF NEW YORK No 01SG6315056 No 01SG6315056 Ouaiiied in Orange County Qualified in Orange County MY Commission Exphua 11/17 M 1 MY Commissars Expires 11/1712026 s12^_021 �y(3R k• Village of Rye Brook ML MR 0� enda FB SE Architectural Review Board Meeting AC V., AD Wednesday,April 17,2024 at 7:30 PM Village Hall,938 King Street jM SF 1. ITEMS: 1.1. ARB24-028 (Consent Agenda) Daniel Albano&Felicia Albano 57 Tamarack Road Rooftop solar array. 1.2. ARB24-029 (Consent Agenda) Danielle Freeman 78 Woodland Avenue 6'high wood fence. 1.3. ARB24-030(Consent Agenda) Alex Szigety&Kaylin Searles 2 Jennifer Lane 5'high welded wire fence and 4'high white vinyl fence and gates. 1.4. ARB24-031 (Consent Agenda) Grant Kurti&Antigona Balidemaj 4 Westview Avenue Rooftop solar array. 1.5. ARB24-032 (Consent Agenda) Robert Weisz 22 Elm Hill Drive Replace patio,repair front stairs and foundation. 1.6. ARB24-033 (Consent Agenda) Paul Tyler&Linda Tyler 16 BelleFair Boulevard Install egress window,legalize finished basement. Consent Agenda Approvals: Motion._ Second rA Abstention Aye; Nay; Adjournment; Notes Page 1 of 4 • Architectural Review Board April 17,2024 1.7. ARB24-020 556 Westchester Ave LLC c/o Anthony Guastella 556 Westchester Avenue New rear windows. Approvals: Motion Second Abstention Aye; Nay; Adjournment; Notes 1.8. ARB24-034 Michael Chiappini&Joanne Chiappini 10 Paddock Road Legalize rear deck. Approvals: Motion Second Abstention Aye; Nay; Adjournment; Notes 1.9. ARB24-035 Cerebral Palsy of Westchester 260 Lincoln Avenue Exterior handicap ramp. Approvals: Motion Second Abstention Aye; Nay; Adjournment; Notes 1.10. ARB24-036 Win Ridge Realty LLC 120 South Ridge Street New awning and illuminated sign. "SBG Home&Design" Approvals: Motion Second Abstention Aye; Nay; Adjournment; Notes Page 2 of 4 • Architectural Review Board April 17,2024 1.11. ARB24-037 (Amendment to Prior Approval) Peter Glantz&Lynn Glantz 3 Old Orchard Road Keep railroad tie wall as sitting wall. Approvals: Motion Second Abstention Aye; Nay; Adjournment; Notes 1.12. ARB24-038 713 Westchester Ave LLC c/o Avinash Khatri 713 Westchester Avenue Convert garage to living space and interior renovation. Approvals: Motion Second Abstention Aye; Nay; Adjournment; Notes 1.13. ARB24-039 Cameron Sager&Jessica Sager 41 Winding Wood Road 2nd story addition over garage,enclose porch and new front entry. Approvals: Motion Second Abstention Aye; Nay; Adjournment; Notes 1.14. ARB24-040 Jamie Billington&Kara Billington 6 Bonwit Road 2nd story addition,one story rear addition,new deck,portico,siding and windows. Approvals: Motion Second Abstention Aye; Nay; Adjournment; Notes Page 3 of 4 • Architectural Review Board April 17,2024 1.15. ARB24-041 Shubin Ma&Wen He 10 Boxwood Place New deck. Approvals: Motion Second Abstention Aye; Nay; Adjournment; Notes 1.16. ARB24-042 Dziugas Reneckis&Cristina Pires 9 Maple Court New deck. Approvals: Motion Second Abstention Aye; Nay; Adjournment; Notes NEXT MEETING: May 15,2024 Page 4 of 4 Laura Petersen From: Laura Petersen Sent: Friday, March 8, 2024 3:31 PM To: 'permitting@infinitysolarsystems.com' Cc: 'Dan Albano'; Steven Fews;Alfredo DiVitto;Tara Orlando Subject: 57 Tamarack Road - Solar Permit Application Attachments: 57 Tamarack Road.pdf; Solar App Full 6.2023.pdf Good afternoon, The Building Department has received in the mail the solar permit application, plans and a check in the amount of$600.00 for the proposed solar installation at 57 Tamarack Road. Please note the following missing items; //1. One electronic/disc copy of the complete application materials. �/ 2. Applicant checklist incomplete (see attached) The application fee is $100.00 and the solar permit fee will be $648.00 ($18.00 / $1,000 cost of construction). Therefore an additional $148.00 will be due when the permit is issued (please see attached instruction pages). Please let me know if you have any questions. eve Thank you 6e Laura Laura Petersen Office Assistant Village of Rye Brook 938 King Street Rye Brook, New York 10573 Phone(914)939-0668 1 Ipetersen(arvebrook.org 1 ow lee � 17 R.1.4►Illil /111111�'t,,''-.C<(0)►��y.:.ri .tr`'.�1.1.�11 :s:s.,._� •..11�11 r.:a es k:; 11�11 .i�ra' -e: ., 11�11_.fis s ..11�11 Ln C14 C)to No �Z as T\tt 1, V 0 �►V o _ cw .o� O U � o •. co u / �•+ CD ° section w U Qt° T ti- G� a Lij O Q N w>ve a rJ O �i Un o Q Lo Lo cc co Sl i•" . x F— 3 C e � tip-•. v! �' O o)► ' V ( 0)> 1 ;:4:,':'o:;'.'.F:.f':,1 1 .1=.-.F_..:>.i� 11 N,::,r•,.< :.;. 11 11 raaF;'Il�ly �?,., .-.,J;111,111 :..- s .'�1�i�1�.`_a_a• > . •. ,.; ;;1,111�111,1 p. :j 1'lll�lll,l,.,. 1�11'Njl`,:t t. ?s Ijl 11 l�l Ij/11111� 11111111� 'r 1111111 r. �•�0 11.� 4/J it„1i �i/.� �0.11�� 4'•� � .i���1, ���0.' , �t. l fit.. D•/•�'� �1�t.4� « li 1 ?t •� A A A O 4�' ?� A �'W;,:� � A I�I':C�' `�.R'`UI O �IJ, ff �q: 1 ,l v�o �� � �1� 'il� �K �� ,'• A��® DATE(MM/DDNYYY) C" CERTIFICATE OF LIABILITY INSURANCE 01/04/2024 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Sean Greening NAME: Provident Protection Plus Incorporated a/CC Est: (973)579-6776 .AX No: (973)579-0111 96 US Highway 206 ADDRIESS: Sean.greening@ProvidentProtectionPlus.com PO Box 4 INSURER(S)AFFORDING COVERAGE NAIC# Augusta NJ 07822 INSURER A: Gotham Insurance Company 25569 INSURED INSURER B: Sel Ins Co of the Southeast 39926 Infinity Solar Systems,LLC DBA Infinity Energy,GARC Construction INSURER c: Endurance American Insurance Company 10641 Corp INSURER D: StarStone Specialty Insurance Company 44776 575 Corporate Drive,Suite 2200 INSURER E: Mahwah NJ 07430-2330 INSURER F: COVERAGES CERTIFICATE NUMBER: 2024-2025 Master#1 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR POLICY EFF POLICY EXP LIMITS LTR TYPE OF INSURANCE INSD WVD POLICY NUMBER MM/DDNYYY MM/DDNYYY COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 2,000,000 DAMAGE TO RINT- CLAIMS-MADE ®OCCUR PREMISES Ea occurrence $ 100,000 MED EXP(Any one person) $ 5,000 A GL202400014906 01/01/2024 01/01/2025 PERSONAL&ADV INJURY $ 2,000,000 MGEN'LAGGREGATE LIMIT APPLIES PER GENERAL AGGREGATE $ 4,000,000 POLICY ®JECT PRO ❑LOC PRODUCTS-COMP/OPAGG $ 4,000,000 OTHER: Per Project Aggregate $ 5,000,000 AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ 1,000,000 Ea accident ANY AUTO BODILY INJURY(Per person) $ B OWNED SCHEDULED S2390880 01/01/2024 01/01/2025 BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS HIRED NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY Per accident $ UMBRELLA LIAB OCCUR EACH OCCURRENCE $ 1,000,000 C EXCESS LIAB CLAIMS-MADE ELD30029796301 (Over Auto) 01/01/2024 01/01/2025 AGGREGATE $ 1,000,000 DIED D I RETENTION$ 0 s WORKERS COMPENSATION PER OTH- AND EMPLOYERS'LIABILITY YIN STATUTE ER ANY PROPRIETOR/PARTNER/EXECUTIVE ❑ N/A E.L.EACH ACCIDENT $ OFFICER/MEMBER EXCLUDED? (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ Limit $250,000 Installation Floater B S2390880 01/01/2024 01/01/2025 Deductible $10,000 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space is required) Certificate Holder is included as an Additional Insured to the above captioned General Liability,Business Auto,and Umbrella Policies on a primary and non-contributory basis for work the insured is performing provided a written contract exists requiring such a status.Additional Insured also applies to product completed operations with respect to the above General Liability policy.Per the terms of the policy,coverage for an additional insured is contingent upon an underlying written agreement with the named insured requiring such coverage.Waiver of subrogation applies to the above General Liability,Umbrella Liability,and Business Auto Policies. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN Village of Rye Brook ACCORDANCE WITH THE POLICY PROVISIONS. 938 King Street AUTHORIZED REPRESENTATIVE Rye Brook NY 10573 ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD DocuSign Envelope ID:B5DCAF17-B7EA-43C6-BB28-21BC715810FE NEW Workers' CERTIFICATE OF YORK STATE Compensation NYS WORKERS' COMPENSATION INSURANCE COVERAGE Board 1a.Legal Name 8 Address of Insured(use street address only) 1b.Business Telephone Number of Insured INFINITY SOLAR SYSTEMS LLC 575 CORPORATE DR LBBY 2 1c.NYS Unemployment Insurance Employer Registration Number of MAHWAH, NJ 07430-2330 Insured Work Location of Insured(Only required if coverage is specifically limited to 1 d.Federal Employer Identification Number of Insured or Social Security certain locations in New York State,i.e.,a Wrap-Up Policy) Number 27-1255670 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) Indemnity Insurance Co.of North America Village of Rye Brook 3b.Policy Number of Entity Listed in Box"la" 938 King Street C55857027 Rye Brook, NY 10573 3c.Policy effective period 10/01/2023 to 10/01/2024 3d.The Proprietor,Partners or Executive Officers are ❑X included.(Only check box if all partners/officers included) ❑ all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box"S'insures the business referenced above in box"1a"for workers' compensation under the New York State Workers'Compensation Law. (To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy).The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate.(These notices may be sent by regular mail.) Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent,or until the policy expiration date listed in box"3c",whichever is earlier. This certificate is issued as a matter of information only and confers no rights upon the certificate holder. This certificate does not amend, extend or alter the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note: Upon cancellation of the workers'compensation policy indicated on this form, if the business continues to be named on a permit,license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Lex Smith DocuVWgf fthrie of authorized representative or licensed agent of insurance carrier) Approved °�_ 9/7/2023 PP b :y Fl - (Signature) (Date) Title: Assistant Program Manager Telephone Number of authorized representative or licensed agent of insurance carrier: 214-721-6248 Please Note:Only insurance carriers and their licensed agents are authorized to issue Form C-105.2.Insurance brokers are NOT authorized to issue it. C-105.2 (9-17) www.wcb.ny.gov Acct#:2215771 f • Q IECIE W[E C W MAR - 8 2024 �. 33 MODULES-ROOF MOUNTED - 13.530 kW DC, 9.570 kW AC, 57 TAMARACK ROAD, RYE BROOK, NY 10573C) PHOTOVOLTAIC ROOF MOUNT SYSTEMIR 1 11 1 o C W O Z N PHOTOVOLTAIC SYSTEM SPECIFICATIONS: GENERAL NOTES SHEET IN DFdX'LAGE of RYE BROOK 0 1. A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. PV 0.0: 1,,/99&&JNG D E PA RTM E N S Z ; 'O SYSTEM SIZE: 13.530 kW DC ,L o = 2. THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM. PV 1.0: PLAN VIEW Z 0 a 9.570 kW AC 3. THE SOLAR PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING,MECHANICAL,OR BUILDING ROOF VENTS. �� o °" MODULE TYPE&AMOUNT: (33)SEG SOLAR SEG�10-BMD-HV[410W] S 1.1: MOUNT DETAILS � � 4. ROOF COVERINGS SHALL BE DESIGNED INSTALLED AND MAINTAINED IN ACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH S 1 2: ROOF SECTION MODULE DIMENSIONS: (UINIH)67.80"144.65"/1.18° THAT THE ROOF COVERING SHALL SERVE TO PROTECT THE BUILDING OR STRUCTURE. � //�� INVERTER: 33 ENPHA E PL -72-2- 24 E 1.1: 3-LINE DIAGRAM / ( ) S IQ8 US US[ OV] 5. MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC61730. INTERCONNECTION METHOD: LINE SIDE TAP E 1.2: NOTES 6. IF APPLICABLE,MODULE GROUNDING LUGS MUST BE INSTALLED AT THE MARKED GROUNDING LUG HOLES PER THE MANUFACTURER'S INSTALLATION REQUIREMENTS. E 1.3: WARNING LABELS REVISIONS UTILITY METER* A72A 4336637 7. AS INDICATED BY DESIGN, OTHER NRTL LISTED MODULE GROUNDING DEVICES MAY BE USED IN PLACE OF STANDARD GROUNDING LUGS AS SHOWN IN DS+ EQUIPMENT SPEC SHEET Description Date Rev AHJ#. RYE BROOK VILLAGE MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. INITIAL DESIGN 2/9/2024 00 SCOPE OF WORK: 8. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. 9. ALL INVERTERS, MOTOR GENERATORS, PHOTOVOLTAIC MODULES, PHOTOVOLTAIC PANELS, AC PHOTOVOLTAIC MODULES, DC COMBINERS, DC TO-DC 0 ROOF ACCESS POINT INSTALLATION OF UTILITY INTERACTIVE PHOTOVOLTAIC SOLAR SYSTEM CONVERTERS,SOURCE CIRCUIT COMBINERS,AND CHARGE CONTROLLERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEM WILL BE IDENTIFIED AND LISTED ROOF ACCESS POINT SHALL NOT BE LOCATED IN AREAS AND ANY NECESSARY ADDITIONAL WORK NEEDED FOR INSTALLATION. FOR THE APPLICATION PER NEC 690A(B). THAT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS,AND Signature with Seal GOVERNING CODES LOCATED AT STRONG POINTS OF BUILDING ADOPTED CONSTRUCTION CODES ROOF#5 CONSTRUCTION IN LOCATIONS WHERE THE ACCESS • 2020 BUILDING CODE OF NEW YORK STATE- (04)SEG SOLAR SEG-410-BMD-HV[410W] POINT DOES NOT CONFLICT WITH OVERHEAD ,��DF NEw y • 2020 PLUMBING CODE OF NEW YORK STATE ROOF#4 SLOPE:38° OBSTRUCTIONS SUCH AS TREE LIMBS,WIRES OR SIGNS. �Q'��-E�W,4 0,9 (13)SEG SOLAR SEG-410-BMD-HV[410W] AZIM.:93° ROOF#3 • 2020 MECHANICAL CODE OF NEW YORK STATE- • 2020 FUEL GAS CODE OF NEW YORK STATE- SLOPE.38 (05)SEG SOLAR SEG-410-BMD-HV[410W] cc: AZIM..273° SLOPE:21° c. .. ' "m • 2020 RESIDENTIAL CODE OF NEW YORK STATE- ° �y • 2020 FIRE CODE OF NEW YORK STATE- AZIM.:03 ROOF#1 o l6 �'� ROOF ACCESS POINT �AgoF7967oNP�,� • 2020 ENERGY CONSERVATION CODE OF NEW YORK STATE- (07)SEG SOLAR SEG-410-BMD-HV[410W] ESSt • 2020 PROPERTY MAINTENANCE CODE OF NEW YORK STATE- SLOPE:34° • 2017 NATIONAL ELECTRICAL CODE PROPERTY LINE '-8" AZIM.:183° FENCE wEIRMW4mm 128 Project Name& f� now Z N Address co MM W 34'-21' a ♦ f� O f. �A, a 1 spa IJJ 1 ER ,�IT # '® Z WMEEM `� w a5-.* -A - 1 0 i� LoC0 o 1 � _ �n M.� Q �L# Q'Ile 0 � NO LU of 2 24 to U11) Ix ATE A �r YzM � 0 1 LU 0 U Y o coo coUC.�.ICEH5` v, V O T� UILOING INS CT0 Viilag f R e Bro ,NY z Q O 0 144- � I MAIN HOUSE 2 SATELLITE VIEW Q 2 W w U-) ���TPICIAK m QmZ � LE o co �1 Pv o.o SCALE:NTS w O Z (�UIRIE�TO FILE z Q >- = a RE Q o 4 , ,, Z `'") < ce 0-7 q Q Q M °o :R r 0 R-�4&-F � 0 DECK � - •�.�� ��I'��prt� LO Village of Rye Brc�k Sheet Name ie _ 0 Architectur I RRB®��� 4 i LU COVER SHEET Approval Date: < Chairman: ------------- � -- _______ a 57 TA RACK ROAD,RYE BROOK,, e � Sheet Size 1 EW YORK 10573 DRIVEWAY = ANSI B � I � zw 11 11 X17 11 7- X LU----- -----_--------- �— 0 Sheet Number Now ----- 4WM EXISTING INTERIOR MAIN SERVICE -------J o a � �. PV 0.0 130-7 � � — — � � � � PANEL(POINT OF INTERCONNECTION) ROOF#2 PROPERTY LINE 1 PLOT PLAN- EXISTING EXTERIOR UTILITY (04)SEG SOLAR SEG-410-BMD-HV[410W] 3 VICINITY MAP Drawn METER#A72A 4336637PremiumC y PV 0.0 SCALE:1/16n_-1-0n SLOPE:15°183° PV 0.0 SCALE:NTS PHOTOVOLTAIC SYSTEM SPECIFICATIONS: BILL OF MATERIALS SYSTEM LEGEND CLO t. SYSTEM SIZE: 13.530 kW DC NUMBER OF MODULES 33 SEG SOLAR SEG-410-BMD-HV[410W] O EXISTING EXTERIOR UTILITY METER N NUMBER OF INVERTER 33 ENPHASE IQ8PLUS-72-2-US 240 #A72A 4336637 C w 9.570 kW AC [ � � o 0 w � � � o MODULE TYPE&AMOUNT: (33)SEG SOLAR SEG-410-BMD-HV[410W] 125A ENPHASE IQ COMBINER 5/5C M ,` Cn COMBINER PANEL 1 EXISTING INTERIOR MAIN SERVICE PANEL 4 o 6 MODULE DIMENSIONS: (L/W/H)67.80"/44.65"/1.18" X-IQ-AM1-240-5/5C,240V (� .— W OC -1 o INVERTER: (33)ENPHASE IQ8PLUS-72-2-US[240V] 60A FUSIBLE AC DISCONNECT,WITH 50A (POINT OF INTERCONNECTION) C w o z N AC DISCONNECT 1 FUSES,240V a Q o NUMBER OF ATTACHMENTS 84 CLICKFIT AC NEW PV AC DISCONNECT GROUPED WITH C z o = SMARTFOOT ATTACHMENT SERVICE EQUIPMENT z � < � RAILS 19 ECOFASTEN CLICKFIT RAIL-171.5"SECTION �\I/.-� U RAIL SPLICE 8 SPLICE KIT F—cl NEW ENPHASE COMBINER PANEL `� U"> ROOF ACCESS POINT EXISTING CHIMNEY MID CLAMPS 50 MID CLAMPS/UFO 1 8�� END CLAMPS 32 END CLAMPS/STOPPER SLEEVE NEW JUNCTION BOX REVISIONS EXISTING SKYLIGHT ROOF#03 GROUNDING LUG 8 GROUNDING LUG Description Date Rev 11 t 5 INITIAL DESIGN 2/9/2024 00 n r 33 NEW SEG SOLAR SEG-410-BMD-HV[410W]MODULES \\ 3"O N ; WITH 33-ENPHASE IQ8PLUS-72-2-US[240V]INVERTERS A H\ � MOUNTED ON THE BACK OF EACH MODULES. \ 6�� I \ � � - Signature with Seal \ -FIRE PATHWAY 0 \ PATHWAY Q ¢ _ 3: OF NEB Y 0 O \ / c _ � �e o� �P EDWgRO Q9 \ I— ."° Q =ROOF OBSTRUCTIONS c� �M /< ��* 4lel r- a m CC O _ - w \\ \\ • =ATTACHMENT POINTS �� ����� G7 I /\\ it� f \\ �,0 q0 79676 ��NP V 0 FESS►o \\< Z 1 n _ =RAFTER x 0 8�� FIRE SETBACK Q 0 , \ 8 FIRE SETBACK Project Name& LL =RACKING SYSTEM Address Q I \\� � � \\ \ \\ \, ao = w \\ \ \\\ CONDUIT RUN(INSIDE ATTIC) \\\ \\ m Q �, , , \ M _ lu7� \LL � M w M � � 0 C) ti � \\ \\ U) CIRCUIT(S) - M w w \ to � OcoU-) \\ CIRCUIT#1 - 13 MODULES w o 26 711 W � z M \\ U ROOF SECTIONS 0 Q Y o 0 NEW ENPHASE COMBINER PANEL AC fir- ROOF#01 CIRCUIT#2-10 MODULES iW 0 CO M II o z QO �� \ 1 o ROOF#01 MODULE-07 � � � w `.� �`r"-, _ SLOPE-34 CIRCUIT#3-10 MODULES m < m Z ° W PV A DISCONNECT GROUPED \ _ -----__— w 0 Z 3� FI E PA IOW Q � >- _ WITH SERVICE EQUIPMENT \ AY\ DECK AZIMUTH-183° i>- � \ ` � \\\\\ - Z Q \ \\\\ MATERIAL COMP.SHINGLE MODULE, ARRAY WEIGHT(LOAD EXISTING INTERIOR MAIN SERVICE \ \ RAFTER SIZE&SPACING-2"X10"@ 16" Q O.C. PANEL(POINT OF INTERCONNECTION) - CALC'S)\ N 01 \ \ \ ROOF#02 MODULE-04 Number of Modules 33 EXISTING � \ \ \ SLOPE-15 IS ING EXTERIOR UTILITY \\ \\ \ \ \ \ \\ 47.39 Weight Wei Module METER#A72A 4336637 \ \ \ AZIMUTH-183° 9 LBS MATERIAL-COMP.SHINGLE Total Module(Array)Weight 1563.87 LBS d RAFTER SIZE&SPACING-211X10"@ 16"O.C. Number of Attachment point 84 Sheet Name 36"FIRE PATHWAY -- 151-21' ROOF#03 MODULE-05 Mounting System Weight 1.5 LBS PLAN VIEW (TYP.) 1 -7 SLOPE-21 (Per Module) 31.011 AZIMUTH-03° Mounting System Weight 126.00 LBS MATERIAL-COMP.SHINGLE Total System Weight sheet size ROOF#02 NEW PV ATTACHMENTRAFTER SIZE&SPACING-2"X10"@ 16"O.C. (Module Weight+Mounting System Weight 1689.87 LBS R F MODULE-13 ANSI B 11 oo #04 ° Weight at Each Attachment Point 18.62 LBS �� 11 AT 4 p O.C. SLOPE-38 (Array Weight/Number of Attachment Pont' 11 X 17 AZIMUTH-2730 Module Area(67.80"x44.65") 21.02 SgFt MATERIAL-COMP.SHINGLE Sheet Number RAFTER SIZE&SPACING-2"X10"@ 16"O.C. Total Array Area 693.75 SgFt ROOF#05 MODULE-04 Distributed Load 2 33 Per PV 1 .0 1 SLOPE-38° (Total System Weight/Total Array Areal SgFt PLAN VIEW AZIMUTH-930 Total Roof Area 1900 SgFt Drawn By Pv 1.0 SCALE:1/8"=1'-0" MATERIAL-COMP.SHINGLE Total Percentage or Roof Covered 36.51% PremiumCAD RAFTER SIZE&SPACING-2"X10"@ 16"O.C. Total Array Area/Total RoofArea)•loo GENERAL STRUCTURAL NOTES: o o 1. THE SOLAR PANELS ARE TO BE MOUNTED TO THE N ROOF FRAMING USING THE ECOFASTEN CLICK FIT LU >- t M o RACKING SYSTEM WITH SMARTFOOT ASSEMBLY. THE W ~ 0 0 PV MODULES ,_ o � N MOUNTING FEET ARE TO BE SPACED AS SHOWN IN C Z Z Z ^ THE DETAILS, AND MUST BE STAGGERED TO C LU iw a � ADJACENT FRAMING MEMBERS TO SPREAD OUT THE SEE(2/S 1.1) FOR C z00 ADDITIONAL LOAD. 0 2. UNLESS NOTED OTHERWISE, MOUNTING ANCHORS ENLARGED VIEW ? /\! 0 SHALL BE 5/16' LAG SCREWS WITH A MINIMUM OF U 2-1/2"PENETRATION INTO ROOF FRAMING. �� \� r- 3. THE PROPOSED PV SYSTEM ADDS 2.3 PSF TO THE / ROOF FRAMING SYSTEM. REVISIONS 4. ROOF LIVE LOAD=20 PSF TYPICAL,0 PSF UNDER NEW Description Date Rev PV SYSTEM. O.V INITIAL DESIGN 2/9/2024 00 5. GROUND SNOW LOAD=30 PSF �6 6. WIND SPEED-115 MPH �'�`G 7. EXPOSURE CATEGORY=6 �� � (E)SINGLE LAYER OF 1 X1 COMP SHINGLE ROOF 8. RISK CATEGORY=II z / Signature with Seal OF NEW Y Q- .E0 W q '� 9O 0, CO P� r 1 *n ¢ 1 ATTACHMENT DETAIL (SIDE VIEW) :YE �& O 07900 e. S 1.1 SCALE:NTS AR0FESS0N Project Name& Address TOP BOLT W MID CLAMP/END CLAMP Z Z W Cn PV MODULE Q o cn cal o CLICKFIT SMARTFOOT LU � M Y Z cM o 0 Q � o 5/16" S.S. BOLT Z Q O `�n ECOFASTEN CLICK FIT RAIL. 2 W w U-) J < wz � 0 Lr)Z a- (E)COMP SHINGLE ROOF Sheet Name 2 X10 RAFTER @ 1611 O.0 MOUNT DETAIL Sheet Size ANSI B 11" X 17" Sheet Number 5/16"-4"SS LAG SCREW MIN 3"THREAD EMBEDMENT,SEALED PENETRATION WITH S1.1 2 ATTACHMENT DETAIL (ENLARGED VIEW) W/SS EPDM BACKED WASHER Drawn By S 1., SCALE:NTS PremiumCAD ROOF-#01 2"X10" RIDGE BEAM ROOF-#03 N o 0 SLOPE-340 (E) COMP. SHINGLE ROOF SLOPE-21° N PV MODULES o o AZIMUTH 183 AZIMUTH-03 �-' ; --cf o � v, ,— M '~ Z0Z 43 to 3 HEIGHT •� W w 16 16 COMP. SHINGLE ROOF �- Q(E) C a00 zW3: a: 0 � �O Z � < \�4.00,-PV MODULES A0 �� �� o %0 2 X10 WOOD FRAME @1611O.C. 000/0, Ul) 2"X10" WOOD REVISIONS Description Date Rev FRAME @1611 0.C. 2X4 COLLAR INITIAL DESIGN 2/9/2024 00 TIES @ 48" O.C. 21Y if 6 Signature with Seal 34 o 0 �1 �OF NEW EDW q9� O/101 CO r ` M ANCHOR POINTS @48" ANCHOR POINTS @48" 1-1 z MAX SPACING TYP. MAX SPACING TYP. 0790 O k. SEE DETAILS SEE DETAILS LOAD BEARING WALL AR�PES SIONP�' LOAD BEARING WALL LOAD BEARING WALL Project Name& 2"X10" RIDGE BEAM Address ROOF-#02 ROOF-#04 ROOF-#05 SLOPE-380 (E) COMP. SHINGLE SLOPE-380 w 50 _ (E) COMP. SHINGLE ROOF _AZIMUTH 183 AZIMUTH 93 z AZIMUTH - 183 (E) COMP. SHINGLE ROOF w M ROOF o in 0 Q M 2"X10" WOOD w � co PV MODULES - �- o M PV MODULES FRAME@16" O.C. Z oYoo O Q � � 2"X10" WOOD - z Qo �LO '.1 . �b a MWLL; LO FRAME@16 O.C. �� - m Q m Z :W �•, PV MODULES Q W 0 Z 2 X10 WOOD 2"X4" COLLAR Q 15° FRAME @16 O.C. o TIES @ 48" O.C. 0 C� Cb Sheet Name �o „ ANCHOR POINTS @ 48 ROOF SECTION MAX SPACING TYP. Sheet Size SEE DETAILS ANCHOR POINTS 48" ANCHOR POINTS 48" @ @ ANSI B LOAD BEARING WA MAX SPACING TYP. MAX SPACING TYP. 11" X 17" WALL SEE DETAILS SEE DETAILS Sheet Number LOAD BEARING WALL LOAD BEARING WALL S1.2 1 ROOF SECTION DETAILS ROOF#01 ROOF#02, ROOF#03, ROOF#04 & ROOF#05 Drawn By s�.2 SCALE:NTS PremiumCAD Rooftop conductor ampacities designed in compliance with THIS PANEL IS FED BY MULTIPLE SOURCES VISIBLE, LOCKABLE, LABELED DISCONNECT PHOTOVOLTAIC SYSTEM SPECIFICATIONS. � N art.690.8,Tables 310.15(B)(2)(a),310.15(B)(3)(a), (UTILITY AND SOLAR) WITHIN 10 OF UTILITY METER c w SYSTEM SIZE: 13.53 kW DC 310.15(B)(3)(c),310.15(B)(16),Chapter 9 Table 4,51 &9. �, ; � :> o 9.57 kW AC Locations specific temperature obtained from ASHRAE 2017 AC OUTPUT CURRENT 39.93A �,, oc o 0 MODULE TYPE&AMOUNT: (33)SEG SOLAR SEG-410-BMD-HV[410M p p 'C Z o Z N MICRO-INVERTER: 33 ENPHASE IQ8PLUS-72-2-US 240 data tables NOMINAL AC VOLTAGE 24oV ENPHASE Q CABLE TO BE ATTACHED TO ,_ w =LO ( ) [ RAIL MIN.3-1/2"ABOVE ROOF SURFACE U. t= Q Q co RECORD LOW TEMP -17°C — � o = AMBIENT TEMP(HIGH TEMP ° Z 0 ( I P2/o) 32C t o � / U CONDUIT HEIGHT 0.5" =�� � 1`_ ROOF TOP TEMP 54°C POINT OF INTERCONNECT, LINE SIDE TAP REVISIONS CONDUCTOR TEMPERATURE RATE 900C Descnption Date Rev EXISTING 240V/200A BUS BAR RATING, MAIN SERVICE PANEL, SINGLE PHASE, INITIAL DESIGN 219/2024 00 WITH A 200A MAIN BREAKER UTILITY COMPANY-CON EDISON CO. OF N.Y. INC. Signature with Seal UTILITY METER#A72A 4336637 SERVICE: OVERHEAD of NEw ,`P���,ED W,q y09 Co P (33)(ENPHASE IQ8PLUS-72-2-US[240V]) _ MICROINVERTERS ra: 240VAC, 1.21A MAX r[ s� CEC WEIGHTED EFFICIENCY 97.0% (N)ENPHASE IQ COMBINER 5/5C M ��O o79s76 <� NEMA 4R,UL LISTED,INTERNAL GFDI X-IQ-AM1-240-5/5C 64A/240V0 R°FE'SSIO� - CONTINUOUS,PROTECTION MAX LINE SIDE TAP of 10 MICRO-INVERTERS IN BRANCH CIRCUIT#3 80A BREAKER ON SOLAR OUTPUT; (N)BLADE TYPE Project Name& N SOLADECK BOX OR UL WITH 10 KAIC CIRCUIT BREAKERS FUSIBLE AC DISCONNECT Address 1741 APPROVED NEMA 3R 60A-2P 120/240VAC I EQUIVALENT TO VISIBLE LOCKABLE LABELED 200A ----`T --------—`z;%.) ( ) o W —, TRANSITION FROM U Q-CABLE TO THWN-2 WIRE 15A 50A FUSES (E)LOADS (E)LOADS Z 10 MICRO-INVERTERS IN BRANCH CIRCUIT#2 I 20A �;� �;� I NO FUSE REQUIRED W o � ti -- p Io ti Cn -- - - i 20A CD 0 o cv CO _ ===gs 4 4I L1 L1 LJJCO LL7 - I L2 L2 (E)LOADS (E)LOADS YZcC) I I I �*� �� U O 20A L1 Y O O 1----�—L -- --'--� L1 L1 L2 �� �� Z 0 �� L2 L2 Lo Q I r---- M lid •• LO 13 MICRO-INVERTERS IN BRANCH CIRCUIT#1 I L1 L1 I N N I M Q im z ZM � ` L2 L2 J M IQ-GATEWAY N O G QLLJ � � -- -- - ---- I G G - - 6r -- r-- — — -- -- ——————————— L c --- ----- ---- ---- -------- ------------ , 0 Z Q I — ------- —_� G Q I L-----------� I PRODUCTION CT - =— TERMINATOR CAP ON LAST CABLE 4 EXISTING GROUNDING CONNECTOR AC TRUNK CABLE(TYP) 3 Sheet Name ELECTRODE SYSTEM 3-LINE DIAGRAM WIRE WIRE WIRE WIRE TYPE TEMP WIRE TEMP CONDUIT WIRE TERMINAL INVERTER STRING GRND GRND WIRE Sheet Size TAG# WIRE FROM-- CONDUIT QTY GAUGE: ENPHASE cl UDES#12 GROUND RATING: AMP DE-RATE: FILL: OCP: 75°C RATING: QTY: NOC: NEC: AMPS I SIZE TYPE ANSI B 1 ARRAY TO JUNCTION BOX IQ CABLE 6 #12 TRUNK CABLE 900 30A x 0.96 x N/A = 28.80A 25A 13 x 1.21A x 1.25 = 19.66A #6 SBC 11" X 17" Sheet Number 2 JUNCTION BOX TO COMBINER PANEL 1"EMT 6 #10 THWN-2 750 35A x 0.94 x 0.80 = 26.32A 35A 13 x 1.21A x 1.25 = 19.66A #8 THWN-2 3 COMBINER PANEL TO AC DISCONNECT 1"EMT 3 #6 THWN-2 750 65A x 0.94 x 1.00 = 61.10A 65A 33 x 1.21A x 1.25 =49.91A #8 THWN-2 E 1.1 4 AC DISCONNECT TO M S P 1"EMT 3 #6 THWN-2 750 65A x 0.94 x 1.00 = 61.10A 65A 33 x 1.21A x 1.25 =49.91 A #8 THWN-2 Drawn By PremiumCA7DJ] PV MODULE RATING @ STC MICRO-INVERTER SPECIFICATIONS n�u0 0 o MANUFACTURER SEG SOLAR SEG-410-BMD-HV[410W] MANUFACTURER ENPHASE IQ8PLUS-72-2-US N C w MAX.POWER-POINT CURRENT(IMP) 13.21 AMPS MAX.INPUT DC VOLTAGE 60 VOLTS W C9 = o Cn MAX.POWER-POINT VOLTAGE VMP � w o ( ) 31.05 VOLTS MAX.CONT.OUTPUT POWER 290 WATTS .C- Z o Z N OPEN-CIRCUIT VOLTAGE(VOC) 37.32 VOLTS NOMINAL AC VOLTAGE 240 VOLTS • iuu w =) C c- co SHORT-CIRCUIT CURRENT(ISC) 13.80 AMPS MAX.AC CURRENT 1.21 AMPS z 0 � NOM.MAX.POWER AT STC PMAX 41 i � Q = ( ) 0 WATT MAX.OCPD RATING 20 AMPS / O M C � / MAX.SYSTEM VOLTAGE 1500V MAX.PANELS/CIRCUIT 13 U 0 VOC TEMPERATURE COEFFICIENT -0.27%/°C 0 "' REVISIONS Description Date Rev INITIAL DESIGN 2/9/2024 00 EQUIPMENT LOCATIONS: GROUNDING NOTES: INTERCONNECTION NOTES: 1. ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY NEC 110.26. 1. GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR 1. LOAD-SIDE INTERCONNECTION SHALL BE IN ACCORDANCE WITH Signature with Seal 2. WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED PURPOSE,AND GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL [NEC 705.12(B)] OPERATING TEMPERATURE AS SPECIFIED BY NEC 690.31 (A),(C) AND NEC TABLES BE RATED FOR SUCH USE. 2. THE SUM OF THE UTILITY OCPD AND INVERTER CONTINUOUS �of NEw y 310.15(B)(2)(A)AND 310.15(B)(3)(C). 2. PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO NEC 690.43 AND OUTPUT MAY NOT EXCEED 120% OF BUSBAR RATING [NEC .P t`\-E�Wq.9 ��p 3. JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES MINIMUM NEC TABLE 250.122. 705.12(D)(2)(3)]. ACCORDING TO NEC 690.34. 3. METAL PARTS OF MODULE FRAMES,MODULE RACKING,AND ENCLOSURES 3. THE SUM OF 125 PERCENT OF THE POWER SOURCE(S) OUTPUT r m U 4. ADDITIONAL AC DISCONNECTS SHALL BE PROVIDED WHERE THE INVERTER IS NOT CONSIDERED GROUNDED IN ACCORD WITH 250.134 AND 250.136(A). CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT z �, ( ) & WITHIN SIGHT OF THE AC SERVICING DISCONNECT.2.2.6 ALL EQUIPMENT SHALL BE 4. EQUIPMENT GROUNDING CONDUCTORS SHALLBE SIZED ACCORDING TO DEVICE PROTECTING THE BUSBAR SHALL NOT EXCEED 120 �0 6 o796i �� INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO NEC NEC 690.45 AND MICROINVERTER MANUFACTORERS'INSTRUCTIONS. PERCENT OF THE AMPACITY OF THE BUSBAR, PV DEDICATED 9 0FESSOo � APPLICABLE CODES. 5. EACH MODULE WILL BE GROUNDED USING WEEB GROUNDING CLIPS AS BACKFEED BREAKERS MUST BE LOCATED OPPOSITE END OF THE 5. ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR SHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BY THE BUS FROM THE UTILITY SOURCE OCPD[NEC 705.12(B)(2)(3)]. USAGE WHEN APPROPRIATE. AHJ. IF WEEBS ARE NOT USED, MODULE GROUNDING LUGS MUST BE 4. AT MULTIPLE ELECTRIC POWER SOURCES OUTPUT COMBINER Project Name& INSTALLED AT THE SPECIFIED GROUNDING LUG HOLES PER THE PANEL,TOTAL RATING OF ALL OVERCURRENT DEVICES SHALL NOT Address STRUCTURAL NOTES: MANUFACTURERS'INSTALLATION REQUIREMENTS. EXCEED AMPACITY OF BUSBAR. HOWEVER, THE COMBINED 1. RACKING SYSTEM & PV ARRAY WILL BE INSTALLED ACCORDING TO 6. THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH OVERCURRENT DEVICE MAY BE EXCLUDED ACCORDING TO NEC W THAT THE REMOVAL OFA MODULE DOES NOT INTERRUPT A GROUNDING 705.12(13)(2)(3)(C). U CODE-COMPLIANT INSTALLATION MANUAL. TOP CLAMPS REQUIRE A DESIGNATED CONDUCTOR TO ANOTHER MODULE. 5. FEEDER TAP INTERCONECTION LOADSIDE ACCORDING TO NEC Z SPACE BETWEEN MODULES, AND RAILS MUSTALSO EXTEND A MINIMUM DISTANCE ( ) W - M cn ti BEYOND EITHER EDGE OF THE ARRAY/SUBARRAY, ACCORDING TO RAI 7. GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE 705.12(B)(2)(1) 0 Q � M MANUFACTURER'S INSTRUCTIONS. COLORED GREEN OR MARKED GREEN IF #4 AWG OR LARGER [NEC 6. SUPPLY SIDE TAP INTERCONNECTION ACCORDING TO NEC 705.12 LU O V_ o W Ul) 250.1191 (A)WITH SERVICE ENTRANCE CONDUCTORS IN ACCORDANCE WITH o 2. JUNCTION BOX WILL BE INSTALLED PER MANUFACTURERS SPECIFICATIONS. IF 8. THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC 690.47 AND NEC 230.42 2.7.8BACKFEEDING BREAKER FOR ELECTRIC POWER v Z CD ROOF-PENETRATING TYPE, IT SHALL BE FLASHED & SEALED PER LOCAL 0 < Ye C) 0 REQUIREMENTS. NEC 250.50 THROUGH 250.106. IF EXISTING SYSTEM IS INACCESSIBLE, OR SOURCES OUTPUT IS EXEMPT FROM ADDITIONAL FASTENING [NEC Z W 0 T---Q Oto n INADEQUATE,A GROUNDING ELECTRODE SYSTEM PROVIDED ACCORDING 705.12(B)(5)]. m 2 W LLi �ROOFTOP OOFTOP PENETRATIONS FOR PV RACEWAY WILLBE COMPLETED AND SEALED W/ TO NEC 250,NEC 690.47 AND AHJ. J Q MZ � APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED CONTRACTOR. Q � O ZZ 4. ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE 9• GROUND-FAULT DETECTION SHALL COMPLY WITH NEC 690.41(B)(1)AND(2) Z �, of � Q_ Q SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER. 2.3.6 WHEN TO REDUCE FIRE HAZARDS Q POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BE STAGGERED DISCONNECTION AND OVER-CURRENT PROTECTION NOTES: AMONGST THE ROOF FRAMING MEMBERS. 1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHENTHE WIRING&CONDUIT NOTES: SWITCH IS OPENED THE CONDUCTORS REMAINING ENERGIZED 1. ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE. ARECONNECTED TO THE TERMINALS MARKED"LINE SIDE"(TYPICALLY THE sheet Name UPPER TERMINALS). CONDUIT AND WIRE SPECIFICATIONS AREBASED ON MINIMUM CODE 2. DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING. NOTES 2. CONDUCTORS SIZED ACCORDING TO NEC 690.8,NEC 690.7. LOCKABLE,AND BE A VISIBLE-BREAK SWITCH 3. PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A 3. VOLTAGE DROP LIMITED T01.5%. RAPID SHUTDOWN FUNCTION TO REDUCE SHOCK HAZARD FOR sheet size 4. DC WIRING LIMITED TO MODULE FOOTPRINT. MICROINVERTER WIRING EMERGENCY RESPONDERS IN ACCORDANCE WITH 690.12(A) THROUGH ANSI B SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W/ SUITABLE (D) 11�� X 17" WIRING CLIPS.5. AC CONDUCTORS COLORED OR MARKED AS FOLLOWS: PHASE A OR L1-BLACK 4. ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO NEC 690.8,690.9,AND 240. sheet Number PHASE B OR L2-RED,OR OTHER CONVENTION IF THREE PHASE PHASE C OR L3- 5. MICROINVERTER BRANCHES CONNECTED TO A SINGLE BREAKER OR BLUE, YELLOW, ORANGE**, OR OTHER CONVENTION NEUTRAL-WHITE OR GREY E 1 .2 IN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE TO GROUPED FUSES IN ACCORDANCE WITH NEC 110.3(B). 6. IF REQUIRED BY AHJ, SYSTEM WILL INCLUDE ARC-FAULT CIRCUIT BE MARKED ORANGE[NEC 110.15]. PROTECTION ACCORDING TO NEC 690.11 AND UL1699B. Dawn By PremiumCAD ---- LABEL 1 � LABEL 9 LABELING NOTES '0 A RNI FOR PV SYSTEM DISCONNECTING MEANS WHERE THE N LINE AND LOAD TERMINALS MAY BE ENERGIZED IN THE ! AR19FWM PERMANENT PLAQUE OR DIRECTORY DENOTINGELECTRIC SHOCK HAZARD OPEN POSITION. THE LOCATION OF ALL ELECTRIC POWER SOURCE W � o 0 POWER TO THIS BUILDING IS ALSO DISCONNECTING MEANS ON OR IN THE PREMISES 1. LABELS CALLED OUT ACCORDING TO ALL COMMON = � o j2017 NEC 690.13(8)J � TERMINALS ON THE LINE AND SUPPLIED FROM MAIN DISTRIBUTION SHALL BE INSTALLED AT EACH SERVICE CONFIGURATIONS.ELECTRICIAN TO DETERMINE EXACT 4 w �. o 6 LOAD SIDES MAY BE ENERGIZED UTILITY DISCONNECT LOCATED EQUIPMENT LOCATION AND AT THE LOCATION(S) REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL •C w o z N IN THE OPEN POSITION OF THE SYSTEM DISCONNECT(S)FOR ALL CODES AND MAKE APPROPRIATE ADJUSTMENTS. •- LU =i7 ELECTRIC POWER PRODUCTION SOURCES C Q Q 144, CAPABLE OF BEING INTERCONNECTED. 2. LABELING REQUIREMENTS BASED ON THE 2017&2020 NEC Z 0 j2017 NEC 705.10J CODE OSHA STANDARD 19010.145 ANSIZ535. ? Q LABEL 2 �I 1,e o MSHALL BE MARKED AT AN ACCESSIBLE LOCATION AT 3. MATERIAL BASED ON THE REQUIREMENTS OF THE AHJ. � i • l THE DISCONNECTING MEANS AS A POWER SOURCE 4. LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE % �� r- AND WITH THE RATED AC OUTPUT CURRENT AND LABEL 10 ENVIRONMENT INVOLVED AND SHALL NOT BE HANDWRITTEN THE NOMINAL OPERATING AC VOLTAGE. PERMANENT PLAQUE OR DIRECTORY TO BE NEC 110.21 RATED AC OUTPUT CURRENT 39.93 A j2017 NEC 690.54J LOCATED AT MAIN SERVICE EQUIPMENT ] REVISIONS POWER TO THIS BUILDING IS ALSO SUPPLIED DENOTING THE LOCATION OF THE RAPID NOMINAL OPERATING AC VOLTAGE 240 V FROM A ROOF MOUNTED SOLAR ARRAY.SOLAR SHUTDOWN SYSTEM DISCONNECTING MEANS IF Description Date Rev ARRAY RAPID SHUTDOWN DISCONNECT IS SOLAR ARRAY RAPID SHUTDOWN INITIAL DESIGN 2/9/2024 00 DISCONNECTING SWITCH IS NOT GROUPED AND LOCATED OUTSIDE NEXT TO THE UTILITY METER. WITHIN LINE OF SITE OF MAIN SERVICE LABEL 3 DISCONNECTING MEANS. ! ARNI N IF INTERCONNECTING LOAD SIDE,INSTALL THIS 2017 NEC 705.10 AND 690.56 C 1 a)J LABEL ANYWHERE THAT IS POWERED BY BOTH THE j ( )(�( DUAL POWER SUPPLY UTILITY AND THE SOLAR PV SYSTEM,IE.MAIN Signature with Seal SERVICE PANEL AND SUBPANELS. SOURCES:UTILITY GRID AND [2017 NEC 705.12(B)(3)J LABEL 11 WARNING PERMANENT PLAQUE OR DIRECTORY TO BE OF NEW PV SOLAR ELECTRIC SYSTEM P�� ED Wq yo LOCATED AT AC COMBINER PANEL. 2017 NEC 110.21(B)J ��" PHOTOVOLTAIC SYSTEM j COMBINER PANEL LABEL 4 r mCr APPLY TO THE DISTRIBUTION EQUIPMENT DO NOT ADD LOADS WARNING s ADJACENT TO THE BACK-FED BREAKER FROM THE ��A o796�6 POWER SOURCE OUTPUT CONNECTION POWER SOURCE. 90FESS10NP�' DO NOT RELOCATE j2017 NEC 705.12(B)(2)(3)(b)J THIS OVERCURRENT CAUTIIDN M DEVICE POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE Project Name& Address LABEL FOLLOWING SOURCES WITH DISCONNECT(S) LOCATED AS WARNINGAPPLY TO THE PV COMBINER BOX SHOWN. j2017 NEC 705.12(8)(2)(3)(c)J LL! DANGEROUS VOLTAGE MAY BE PRESENT AT ALL TIMES THIS EQUIPMENT FED BY MULTIPLE Z SOURCES.TOTAL RATING OF ALL � ti � OVERCURRENT DEVICES,EXCLUDING CO Q o N o MAIN SUPPLY OVERCURRENT CO O v- I c� c� Ln DEVICE,SHALL NOT EXCEED Y Z M T-- AMPACITY OF BUSBAR. V Y o 0 z � o (0 � U-) LABEL 6 � :k � QM Z SOLAR PV SYSTEM EQUIPPED BUILDINGS WITH PV SYSTEMS SHALL HAVE A O Q � 0 Z WITH RAPID SHUTDOWN PERMANENT LABEL LOCATED AT EACH SERVICE z LO a Q EQUIPMENT LOCATION TO WHICH THE PV SYSTEMS Q TURN RAPID SHUTDOWN ARE CONNECTED OR AT AN APPROVED READILY SWITCH TO THE ( 1 Q "OFF POSITION TO SOLAR ELECTRIC VISIBLE LOCATION AND SHALL INDICATE THE �J SHUT DOWN PV SYSTEM PV PAXELS AND REDUCE LOCATION OF RAPID SHUTDOWN INITIATION SHOCK HAZARD DEVICES. IN THE ARRAY j2017 NEC 690.56(C)(1)(a)J Q 2 Sheet Name LABEL 7 < SIGN LOCATED AT RAPID SHUT DOWN DISCONNECT C WARNING SWITCH [� ACvn -- PV ARRAY LABELS • j2017 NEC 690.56(C)(3)J Sheet Size ANSI B LABEL 8 11 11 X 1 711 N N PERMANENT PLAQUE OR DIRECTORY DENOTING THE MAIN DISTRIBUTION UTILITY DISCONNECTS) LOCATION OF ALL ELECTRIC POWER SOURCE AC COMBINER PANEL UTILITY METER Sheet Number DISCONNECTING MEANS ON OR IN THE PREMISES SHALL BE POWER TO THIS BUILDING IS ALSO SUPPLIED INSTALLED AT EACH SERVICE EQUIPMENT LOCATION AND AT AC DISCONNECT MAIN SERVICE PANEL FROM A ROOF MOUNTED SOLAR ARRAY WITH THE LOCATION(S)OF THE SYSTEM DISCONNECT(S)FOR ALL E 1.3 A RAPID SHUTDOWN DISCONNECTING MEANS ELECTRIC POWER PRODUCTION SOURCES CAPABLE OF GROUPED AND LABELED WITHIN LINE OF SITE AND 10 FT OF THIS LOCATION BEING INTERCONNECTED. j2017 NEC 705.10J Drawn By PremiumCAD wwwsegsola !S E SEG S 0 L A R S 0 L A R YUKON Series SEG-XXX-BMD-HV(108Cells) Electrical Characteristics Module Type SEG-400-BMD-HV SEG-405-BMD-HV SEG-410-BMD-HV SEG-415-BMD-HV S STC NOCT STC NOCT STC NOCT STC NOCT YUKON Series Maximum Power-Pmp(14) 400 301 405 304 410 308 415 311 Open Circuit Voltage Voc(V) 37.12 34.64 37.22 34-73 37.32 34.81 3742 34.90 Half-Cell Monofacial Module Short Circuit Current-Isc(A) 13.60 10.99 13.70 11.07 13,80 1115 13.90 11.23 Maximum Power Voltage-Vmp(V) 30.81 28.82 30.93 28.91 31-05 29.05 31.16 29.19 Maximum Power Current-Imp(A) 12.99 10.44 13.10 10.51 13.21 10.59 13.32 10.66 Module Efficlenc m Y STC-t1 (°ab ) 20.48 20.74 21.00 2125 400 21n25% Power Tolerance(W) (0.+3%)Maximum System Voltage 15 V 00 DC Module Power Output Max Efficiency . Maximum Series Fuse Rating 25 A r STC ttmdrance 1000 Whn'n*dute temperature 2WC AM IS NOCT UYedinnce BMWlm'ambient tempmture 20*C f wduty tompegattue 45"C wM0 speed in Pnwer nteasur MOIIJ(o1c4AntR 0 396 Mechanical Specifications Technical Drawing 30Z.Va T External Dimension 1722 x 1134 x 30 mm t M:o as Weight 21.5 kg Key Features ..4 So.a-Ce,ls PERC Mona 182 x 91•iin7(108 pcs) u�• P ` High mociuie conversion Better temperature FI ont Glass 3.2 mm AR coating tempered glass!low iron 2-ci :., sn:tr•,m efficient , ,, coefficient °µ - Y Frame Black anodized a uminium alloy t.srSJ-. Junction Box, IP68 3 diodes Super multi bulbar F Low attenuation long Connector Type tVlC4 E7, techno ogy warranty Cable Type Length 12 AWG PV Wire UL) J1200 rim r a : Superior load Mechanica Load(Front) 5400 Pa 1 113 psfY qn Aesthetic appearance ti capacity Mechanica Load(Rear) 3600 Pa 75 psf' 'U1142mm A4 fa'Ss0.lJ8tn 'Refer to SEG instal ati)an hAanuat for details 33n•' •t.�.t f':Mt USA based liability, p Houston,Texas based insurance company Packing Configuration 5�, ;p,� Container 20'GP 40'HO TOer 10 SEG tnSIAllat►on Mmiml taf deiAi15 Pieces per Pallet 36 36 IN Curve Warranty Product Certification Pallets per Container 6 2 Y Crib te!n1{1-25t mciftat lilac ctp?gW.10- '9 98°k Additional Value From Linear Warranty IEC61215.2016; IEC 61730:2016, UL1703 UL61730/ETUCEC 14 IEC62804 PIO Pieces per Container 216 936 IEC61701 Salt Mist '0 Ir+orletltrrvd_rW0WW 90 3/e ' -�, IEC62716 Ammonia Resistance 6 Inmanttffam=4MY» IEC60068 Dust and Sand tnctaaw inert-anryna� 8% IEC61215 Hailstone Temperature Characteristics 20 A. A. I - --�, ®0� Fire Type(UL61730:TYpet Pmax Temperature Coe fficient -0,35�lO'C 44 o s 10 zo 2s 1SO14001:2015; ISO9001:2015; IS045001:2018 gears Voc Temperature Coefficient -0.27%PC <Yeatrs> <Year'^s> �A'1 CALIFORNIA � 25material Guarantee on product 2 Linear power m►v a C( 0FSEC Erl�r COMMISSIONIsc T +® em erature Coefficient 0.05% C and workmanship �.output warranty tr>teredt p � 6 Incident tnad IWO M1 Operating Temperature -40^'+85°C caftcampctoc A CBIt;temp=.ZS C 7 GQt�.tetnn.�48C Cow-temN465C Nominal Operating Cell Temperature(NOCT) 45#2°C , CrlhtA.mc t About SEG Solar 0� va"em SEG Solar is a leading manufacturer of high-performance solar panels for residential,commercial,and utility applications www.segsolar.com The company.headquartered in Houstorl,Texas,is committed to providing cost-effective and reliable solar solutions that ® Specifications subject to technical changes SEG.DS 2023-02 Rev'01 EN help customers reduce l.heir energy cosis and carbon footprint Download Datasheet 0 ENPHASE IQ8 and 1Q8+ Microinverters Commonly used module pairings' W 235-350 235--440 Module compatibility 60-cell/120 half-cell 54-cell/108 half-cell,60-cell/120 half-cell,66--cell/132 half cell and 72-cell/144 half-cell MPPT voltage range V 27-37 27-45 Operating range V 16-48 16-58 Min./Max.start voltage V 22/48 22/58 Max.input DC voltage V 50 60 Max.continuous input DC current A 10 12 Max.input DC short-circuit current A 25 Max.module 1. A 20 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration 1 x 1 Ungrounded array;No additional DC side protection required;AC side protection requires max 20A per branch circuit OUTPJT Peak output power VA 245 300 Max.continuous output power VA 240 290 Nom na (L-L)voltage/range v 240/211-264 IQ8and IQ Microinverters Max.continuous output current A 1.0 1.Z1 Nomina frequency Hz 60 Our newest IQ8 Microinverters are the industry's first microgrid-forming,software defined Easy to install Extended frequency range Hz 47-68 microinverters with split-phase power conversion capability to convert DC power to AC Lightweight and compact with plug-n power efficiently.The brain of the semiconductor-based rnicroinverter is our proprietary A short circuit fault current over application specific integrated circuit(ASIC)which enables the microinverter to operate in p ay connectors 3 cycles Arms 2 grid-tied or off-grid modes.This chip is built in advanced 55nm technology with high speed Power Line Communication(PLC) Max.units per 20 A(L-L)branch circuit-S 16 13 digital logic and has superfast response times to changing loads and grid events,alleviating between components constraints on battery sizing for home energy systems. Faster insta1ation with simple two-wire Total harmonic distortion <5% cabling Overvoltage class AC port III AC port backfeed current mA 30 High productivity and reliability Power factor setting 1.0 • Produce power even when the grid is down* Grid-tied power factor(adjustable) 0.85 leading-0.85 lagging • More than one million cumulative hours Peak efficiency 97.7 Part of the Enphase Energy System,I08 I08 Series Microinverters redefine of testing CEC weighted efficiency 97 Series Microinverters integrate with the reliability standards with more than one • Class 1i double-insulated enclosure Night-time power consumption mw 60 IQ Battery,IQ Gateway,and the Enphase million cumulative hours of power-on • Optimized for the latest high-powered A monitoring and analysis software. testing,enabling an industry-leading PP 9 Y 9 9 Y g PV modules limited warranty of up to 25 years. Ambient temperature range -40°C to+60*C(-40*F to+14(YF) Microgrid-formming Relative humidity range 4%to 100%(condensing) - Complies with the latest advanced grid DC Connector type MC4 support** up:: Dimensions(H x W x D) 212 mm(8.3")x 175 mm(6.91 x 30.2 mm(1.2") • Remote automatic updates for the Weight 1.08 kg(2.38 Ibs) latest grid requirements Connect PV modules quickly and easily I08 Series Microinverters are UL listed • Configurable to support a wide range Cooling Natural convection-no fansof profiles ro rid to I08 Series Microinverters using the as PV Rapid Shutdown Equipment and 9 P Approved for wet locations Yes H included Q-DCC-2 adapter cable with conform with various regulations,when ; Meets CA Rule 21(UL 1741-SA)and IEEE Pollution degree PD3 plug-n-play MC4 connectors. installed according to manufacturer's I 1547:2018(UL 1741-SB 3rd Ed.) instructions. I Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Note: Environ.category/UV exposure rating NEMA Type 6/outdoor I08 Microinverters cannot be mixed together with previous generations of Enphase microinverters(1Q1 Series,106 Series,etc)in the same system. CA Rule 21(UL 1741-SA),UL 62109-1,IEEE 1547:2018(UL 1741-SB 3111 Ed.),FCC Part 15 Class B,ICES-0003 Class B,CAN l CSA C22.2 NO.107.1-01 *Only when installed with 10 System Controller 2,meets UL 1741. Certifications This product is UL Listed as PV Rapid Shutdown Equipment and conforms with NEC 2014.NEC 2017.and NEC 2020 section 690.12 and C22.1-2018 **I08 and I08PIus support split-phase,240V installations only. �` Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according to manufacturer's instructions. (1)Pairing PV modules with wattage above the limit may result In additional clipping losses.See the compatibility calculator at https✓Ank.onphase.corn/module-compatibility. ©2022 Enphase Energy.All rights reserved.Enphase,the Enphase logo,I08 Microinverters, (2)Nominal voltage range can be extended beyond nominal If required by the utility.(3)Limits may vary.Refer to local requirements to define the numberof microinverters per and other names are trademarks of Enphase Energy,Inc.Data subject to change. 108SP-12A-DS-0067-03-EN-US-2022-12-27 branch In your area. 118SP 12A-DS-0067-03-EN-US-2022-12-27 " ENPHASE IQ Combiner 5/5C NUMBERMODEL IQ Combiner 5 with IQ Gateway printed circuit board for integrated revenue grade PV production IQ Combiner 5(X-I0-AM1-240-5) metering(ANSIC12.20±0.5%),consumption monitoring(±2.5%)and IQ Battery monitoring(12.5%). Includes a silver solar shield to deflect heat ENPHASE IQ Combiner 5C with IQ Gateway printed circuit board for integrated revenue grade PV production IQ Combiner 5C(X-IQ-AM1-240-5C) metering(ANSI C12.20±0.5%),consumption monitoring(±2.5%)and IQ Battery monitoring(±2.5%). Includes Enphase Mobile Connect cellular modem(CELLMODEM-M1-06-SP-05)'.Includes a silver solar shield to deflect heat WHAT'S IN THE BOX IQ Gateway printed circuit board IQ Gateway is the platform for total energy management for comprehensive,remote maintenance and management of the Enphase IQ System Busbar 125A busbar with support for 1 x IQ Gateway breaker and 4 x 20A breaker for installing IQ Series Microinverters and IQ Battery 5P IQ Gateway breaker Circuit breaker,2-pole,10 A/15 A Production CT Prewired revenue-grade solid core CT,accurate up to 0.5% X-I0-AM1-240-5 X-I0-AM1-240-5C Consumption CT Two consumption metering clamp CTs,shipped with the box,accurate up to 2.5% IQ Battery CT One battery metering clamp CT,shipped with the box,accurate up to 2.5% CTRL board Control board for wired communication with IQ System Controller 3/3G and the IQ Battery 5P IQCombiner 5/5C Enphase Mobile Connect(only with IQ Combiner 5C) 4G-based LTE- 1cellular modem(CELLMODEM-M1-06-SP-05)with a 5-year T-Mobile data plan The IQ Combiner 5/5C consolidates interconnection equipment into a single enclosure and Smart Accessories kit Spare control headers for CTRL board streamlines IQ Series Microinverters and IQ Gateway installation by providing a consistent, • Includes IQ Gateway forACCESSORIES aND REPLACEMENT PARTS (NOT INCLUDED, ORDER SEPARATELY) pre-wired solution for residential applications.IQ Combiner 5/5C uses wired control communication and control communication and is compatible with IQ System Controller 3/3G and IQ Battery 5P. • Includes Enphase Mobile Connect CELL MODE M-M1-06-SP-05 4G-based LTE-M1 cellular modem with a 5-year T-Mobile data plan (CELLMODEM-M1-06-SP-05),only CELL MODE M-M1-06-AT-05 4G-based LTE-M1 cellular modem with a 5-year AT&T data plan The IQ Combiner 5/5C,along with IQ Series Microinverters,IQ System Controller 3/3G,and with IQ Combiner 5C IQ Battery 5P provides you with a complete grid-agnostic Enphase Energy System. • Supports flexible networking:Wi-Fi, Circuit breakers(off-the-shelf) Supports Eaton BR210,BR215,BR220,BR230,BR240.BR250,and BR260 circuit breakers Supports Eaton BR220B,BR230B,and BR2406 circuit breakers compatible with hold-down kit Ethernet,or cellular • Provides production metering Circuit breakers(provided by Enphase) BRK-10A-2-24OV,BRK-15A-2-24OV,BRK-20A-2P-24OV,BRK-15A-2P-24OV-B,and BRK-20A-2P- 240V-B(More details in"Accessories"section) (revenue grade)and consumption monitoring XA-SOLARSHIELD-ES Replacement solar shield for IQ Combiner 5/5C XA-ENV2-PCBA-5 IQ Gateway replacement printed circuit board(PCB)for Combiner 5/5C Easy to install X-I0-NA-HD-125A Hold-down kit compatible with Eaton BR-B series circuit breakers(with screws) IQ Series Microinverters IQ System Controller 3/3G • Mounts to one stud with centered ELECTRICAL SPECIFICATIONS The high-powered smart grid-ready IQ Series Provides microgrid interconnection brackets Microinverters 006,IQ7,and IQ8 Series) device(MID)functionality by • Supports bottom,back,and side Rating 80 A dramatically simplify the installation process automatically detecting grid failures and conduit entry seamlessly transitioning the home energy System voltage 120/240 VAC,60 Hz system from grid power to backup power • Supports up to four 2-pole branch circuits for 240 VAC plug-in breakers Busbar rating 125 A (not included) Fault curent rating 10 kAIC • 80 A total PV branch circuits Maximum continuous current rating(input from PV/storage) 64 A • Bluetooth based Wi-Fi provisioning for easy Wi-Fi setup Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series distributed generation(DG)breakers only(not included) Maximum total branch circuit breaker rating(input) 80 A of distributed generation/95 A with IQ Gateway breaker included Reliable IQ Gateway breaker 10 A or 15 A rating GE/Siemens/Eaton included • Durable NRTL-certified NEMA type 3R enclosure Production metering CT 200 A solid core pre-installed and wired to IQ Gateway IQ Battery 5P IQ Load Controller Fully integrated AC battery system.Includes six Helps prioritize essential appliances 5-year limited warranty Consumption monitoring CT(CT-200-CLAMP) A pair of 200 A clamp-style current transformers is included with the box field-replaceable I08D-BAT Microinverters during a grid outage to optimize • Two years labor reimbursement IQ Battery metering CT 200 A clamp-style current transformer for IQ Battery metering,included with the box energy consumption and prolong program coverage included for both battery life the IQ Combiner SKUs • UL17411isted L LISTED 5-year 'A plug-and-play industrial-grade cell modem for systems up to 60 microinverters.(Available in the US,Canada,Mexico,Puerto Rico,and the limited US Virgin Islands,where there is adequate cellular service in the installation area.) warranty ©2023 Enphase Energy.All rights reserved.Enphase,the a and CC logos,IQ and certain other marks listed at https://eni2hase.com/trademark-usage-quidelines are trademarks of Enphase Energy,Inc.in the US and other countries. Data subject to change. IQC-5-5C-DSH-00007-2.0-EN-US-2023-09-27 IOC-5-5C-DSH-00007-2.0-EN-US-2023-09-27 U--_n-nut C. C�, • • TY T, L L _q rr L LI r. rz -L L -7�U\ LE 11 . Lr r`L r-T 7%71 e .1 -—, "1, 7 ---7... ... !L Le' Ej L; L) f L :�I� � ( :i� _�ir� �l1JL • Lr _ L L IT, t � i I .......... 14UM tL .4, 1 R-1 - tt��21 1; �L,.� 1 ( -(; .6 , ,I 'I L ;� '[ Tir _0411 CWte U1`16 r 20 3 ce 4 Ce L; • ......L t L rt ce R341 I 2W 16317 Aepoll on Repo od, -341 1� -202 103- t7 .f [ � I �` ,;� [ .,l 11 11 � ( c: ll { � �;I1 t. `i y_I IJ tto 1 :� �I � �•� 1 .[� .I I( •t-- rL-- r I _ I, 1 l� cl �02? �• t I L lJ( L•....`I r} �, ! I n - !- - r, Il l r. .,• �t... - .j( t- �_ ., � -'7,: ( - ,�"' r -`+ :� •f � .r `l �:' :J"?�, r L a arMive 9tImpl'es prod=t m spedffi&d­-M,JVS *f• 0 LA;F L r�jps ediTo�o rr L • 1. J-� it 0 11- t Ir V I Ila • Th 4& dt yt c is ' t y in lreouirem6ijt� te d qdpo, IF; E C6 e L rds il­LS�feW U �-�►/� 511 %%W tCoovel,br lem 11 A rco h h E tgM' end f�io U UN 1741 46ve n6ctib77 1nvenerALI— /W 221 � do U eLL L_�L. -p 6� it kopid06n�ql with 1b d EnOp SO4�,&Otk�v�uw 13 §sUe D-at#' ud[n§ L r e nts i ri-UL Al 7 l­­Sup0I6mer#s$A and ILI -7 d 4s� 01 1Q8PLQ -72,JQBA�,287-72? M8� 2 PfW rlg�"sburoe b f iL co"edtiq0- dL I It C L, L! r L--- J. f L Estntpr, onriptting Dip ed�l_t I � 164�ol) F-.t eta ndard onfo man6e tI n Lr�ionateLIL L 1,--)— • -Datb Qr 6-1 tere , aeY .5 _W beI,t�� I '►-�: i `l�r r 1 �ied 6 (btAL I I _�� ,i �� 1 I i� } Hal2j, p #b 6C h/I�f/1"`6AV flu RMA, m , ;,,­& w' 16474i4ter� �t6� 4ab_'"04bt a ue m e f/b ss-de- s addiftonat chcters.,-, LIEE �,Irocedur6s Pr tri6ut e Mn i -ce wito,, the Stand d(�)-Ha{ ,l � :�(-� .(I � 1l � .1� ��:� 'v' bt�U nVestigoted by--UL in bGcol rd a� a��; � I[ tAssociate Interfaces,ls.§ue 'd onlhig-tC rtificate'. E Energy R-6sources-,o Rs-YwRhT1ectric­PoWei Systems�E ifidicafte 03 -I. ,. L t /05/2020---­- _�_ - 1 :, L• li � t. ;1- I '�� _I � � II ! �� i-� it ii: � :i� � ►i l � =�- ! �� II�� ••� ',^�1• � �� I ^I � � ,I:�, •_� ; �d,ard for Safbt� �I 4 'y. Pa' I� ,-I , 1 � 1 r I.1 ,:I , i t_ remerits er u I S UL-Online C-e ms ec ory�at, quo Pointer Converters for Y i-h Photovoltaic Pow -syst -_� de-rs in ner -2 e�- 1, af&Y of onve fpr*tJse in Pho a a Power Pa G e, -at __, t 1._ =i _-' I _=I __► t I {I ' _ L�- _ I IL 69 tovolt I -2 SOWY Of pe tif[cati bi- s6L 11fi6nati iformafio ms r en r Inverters. L u �dditiiona�In W_ _i , t L'. I ( ;.-.I (_ �- 1 _, for infoi �t!� .�Pqyir�menI�tom/datdiba15Ystp 7,?�rt F: P?rtic rt&rs. L -for use in .-C Wo t Ita is power -6nVette to ii 0 k. syst in rt 1* 6n671 Requirerni-opts iu/ Priza�i pply the-, I I Ili. L, -11, IL LLI -U i to-a -f22-2 No.L62109-1IJ� CAN/CSALSafety 6f ovver rs ov _bf Cow a c"_ •oes not i -fir,e T-tb i s-Ce rt i fi cate JH n' prov pply the--IJL Mark. Only Ut:----- Id ti 20 07 low-Up *136rvic6� Procedde-p peqvil a UL"! L Power V n I cpower n L L e -Saf6ty of'P ' e -s for.,use-i L7 rp —U C-AN/CSA C hose-products-bea nig-the L Mark shoutd-be consWered-as being-UL Pertified and e t'Onty-t ��t R -Parficulaie�eq' ments fdrinverters-i. -N o. 6 21 -2, r Converters 22�2 -sy ms 6. rt 2: uire ZQ1_ 07 I�,cqv�r:ed updpriJL,, F911ow-VP Serve pes. on It iUL. L; ILi %R21: The evaluation o the Standards above provides evidence of compliance to the intent,', Lbok for the-U L-,Certjfida((6-�-_M ark oplhe- ro • Of the existing California Rule 21 Interconnection (references to the past publication of . ;I• -:, ;5' :,: :� .,:r. .• _., .;' �'-=',. , ,r;r: I h i'(;,� !t ��.'I ii :�; 1 I - �� II i J:�'• -1 (��}° I I ,I:i 1�L IEEE 1547 standards) and UL1 741 Table SA1.1 option to use the IEEE 1547.1-2020 and L �.l UL1 741 SB test methods in conjunction with using IEEE 1547-2018 as the SRID under Men atio th::-.Any inf6rmabory aid docu•'' • nj' Volvihg UL Mark services are provid 'd on-behalf of UL L to, L which SA1 1.2 Normal Ramp Rate is not addressed. Additional testing was conducted IJ Lit confi1 :llryl :1 ail it - i ; � ! II I i j 1 I :� rmed firmed compliance to Normal Ramp Rate SA1 1.2 . See also Appendix A. r LLC (UL)or a' r!,S��utfi A' en--S 6, UL-Qr c tes-evid L ,:,: _ t. : ;,; ,,.: �. _. ���.:. Stabdards -bo ence of D- 1. tfir L _10 th"I t ndArds­abpV.6 prGvidese V, I h�e�?q he�ti n App ca r -The vatuationrtq e r • t4l Ye roved,a ( l ! :I1 i � I I:� t •: 'I i� � I I � !. �� ': I � � •i'� ( �t I .1 •ci 1 t HEF�R�q I 11loof, SFR U0 • 13):...The�-evafuafien �C-e�to• .� f ......... m 14 H a vidence of 6a ir I n t -LAp I il. ;L ..... Lit L r _ ��:I �! l ► 1�� !.i ( I I I ti 1. (! , fi I l I I .(I I ' r i _ �L.L C( L -SR V Ru-lie plibation %L L L -L T :,. J - i , lit, L L7 L j I 1 j _ Iii I I I ! ; fi i' I i l !I J j I [ ( i ! I' ( ItL' ! i L IL J. tLI tG� II. - — I! .1 L 7L L 7,7 1, • ;Na by L • • L ;7.. rl L L ( L^j�,1 I , ,1 -1 I � [ i •i r I i L, J I i 4 ! � _ F T .L I .,� ! I �.. �,1 I�,.. L. I( (. .I• 1— n� ? .� �' .I- t— .'t_I � J,,J! - -) ,4 t �.I I. I.� ,t+ a. .{-I � _ '�1. � :.( �. .f__ � l I, ..� � 4't .� •�'�-_ �.,U •i✓= I; I I A IIU L ,, :�' t L •d"Mafftftholig,Diftckw ShL Ma t fJ 71,t;YL •• UM IJ I Lj 4UNW1 har� -o' 'n U�F�� %MWOU11111111111 alf IC10 are prAdW 0n*948ff U1 19 U4 mot wrvile4m are P -7 'ii 4C �fonnviclp I I I I 1�t=rw h-6 11ten" "16pihip Wt4 , r S"Oni U&LLMWi,,G*rV Z;2zlqL",_� of UL For Rom" mmi • T L fAW a kKd j 4,ulll 4c'fY -10 4E r[ 0 LL. L CLI L L 1: L I WIN z- CF SMART FOOT W/CLKR AL MLL CF SMART FOOT W/CLKR AL MLL PART NUMBER DESCRIPTION 2012028 CF SMART FOOT W/CLKR AL MLL 2) CLICKFIT RAIL ATTACHMENT ASSY W/MNT BOLT i I I i I 2 (D 1.57 1.79 O [40.0] [45.3] O 2.06 ITEM NO. DESCRIPTION ([52.3] 1 CLICKFIT SMARTFOOT WIYY 2 CLICKFIT RAIL ATTACHMENT ASSY W/MNT BOLT 1.010 [25.8] 1� CLICKFIT SMARTFOOT 1'91 NNW [48.6] MATERIAL ALUMINUM,STAINLESS STEEL,POLYMERIC FINISH MILL l O ADHESIVE RELEASE PAPER 3.00 O O [76.2] OO c 3.83 [97.3] R.20 [5.0] 2.29 3.53 [58.2] [89.7] FLASHING SYSTEM MATERIAL ALUMINUM FINISH MILL SHEET OF REV: CS-1 SHEET 20F2 REV: CS-1 PRODUCT CUT SHEET .�,EcoFasten For Installers. By Instal[Lers. CF STD RAIL AL MLL 171 *5" PART NUMBER DESCRIPTION 2012025 CF STD RAIL AL MLL 171.5" 1 ITEM NO. DESCRIPTION 1 CF STD RAIL MILL AL RAIL EXTRUSION PROFILE, [4356.1 MM] LONG 1) CF STD RAIL MILL AL RAIL EXTRUSION PROFILE, [4356.1 MM] LONG 171.5 111111 1.57� 1.57 Material Aluminum Finish Mill REV.- CS1 PRODUCT CUT SHEET -<,V,, ,r>EcoFasten For ln�-,tallers. By InstaLLers. CF RAIL SPLICE SS PART NUMBER DESCRIPTION 2012013 CF RAIL SPLICE SS 0 a ITEM NO. DESCRIPTION 1 RAIL COUPLER 1) RAIL COUPLER -O- -O- 1.06 1.37 � p 7.87 Material Corrosion Resistant Steel Finish Mill REV.— CS1 CF/RF END CLAMP AL BLK CF/RF MID CLAMP AL BLK PART NUMBER DESCRIPTION HEIGHT(H) PART NUMBER DESCRIPTION HEIGHT(H) 2099016 CF/RF END CLAMP AL BLK 30MM 1.17 2099022 CF/RF MID CLAMP AL BLK 30-40MM 1.57 2099017 CF/RF END CLAMP AL BLK 32MM 1.25 2099023 CF/RF MID CLAMP AL BLK 40-50MM 2.07 2099018 CF/RF END CLAMP AL BLK 35MM 1.37 2099019 CF/RF END CLAMP AL BLK 38MM 1.49 2099020 CF/RF END CLAMP AL BLK 40MM 1.57 it 1 2099021 CF/RF END CLAMP AL BLK 45MM 1.76 ITEM NO. DESCRIPTION 1 CLICKFIT HEAVY DUTY MIDCLAMP ASSEMBLY, BLACK ITEM NO. DESCRIPTION 1) CLICKFIT HEAVY DUTY MIDCLAMP ASSEMBLY, BLACK 1 CLICKFIT HEAVY DUTY END CLAMP ASSEMBLY, BLACK 1) CLICKFIT HEAVY DUTY END CLAMP ASSEMBLY BLACK . 1'97 an 1.83 + Lmm yy + M yy 1 .57 1.55 0 H (2.09) (2.08) H Material Aluminum/Stainless Steel Finish Black Material Aluminum/Steel Finish Black REV.- CS1 REV.- CS1