Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
EP24-077
C n a n - � N N W v N OC W en „_, Z q W bbo w z v W `n O a cn C4 H PLO CIA o °rq w 1 + 1 O w W o W 1 O Cf) coW w w H wN U zz 0c) � 9 ° oy 0*4% P-4 Cf) CIN CA cf a Q W W wG fill o 0 U Z rz z z o 00 z xi a � - H x Z 44 oQ :p yE BR BUIL E. .'`r MENT VIL E OF RYE OK 938 KIN ET RYE B ,NY 1057 (914)9 \ 939-5801 -or ELECTRICAL PERMIT APPLICATION Westchester County Master Electricians License Required FOR OFFICE USE ONLY EP #: C�) 4-0-7 7 Approval Date: APR 1 0 20 �7� Permit Fee: $ Approval Signature: Other: Disapproved: (fees are non-refundable) Application dated, is hereby made to the Building Inspector of the Village of Rye Brook NY, for the issuance of a Permit to install and/or remove electrical equipment,wiring, fixtures,or to perform other high or low voltage electrical work as per the detailed statement described below. The applicant & property owner, by signing this document agree that all electrical work perforated will be in conformance with all applicable Federal, State, County and Local Codes. 1.Address: 67 1/2 Wiindingwood Rd S. Rye Brook, NY 10573 SBL: 135.34-1-38 zone: 2.Property Owner: Sean Coffey Add: 67 1/2 V%rndingwood Rd S. Rye Brook, NY 10573 Phone#: 516-241-5197 Cell#: email.: seancoffey47@yahoo.com 3.Master Electrician: Frank Saladino of Testa Energy Operations4ddress: 1073 Rt 94 Unit 4, New Windsor, NY 12553 Lic. #: 1814 Phone#:A 5 Cell#: email: F,�a 1 CA 100(s'-t<S Icc-(Crr\ Company Name: Tesla Energy Operations Address: 1073 Rt 94 Unit 4 New Windsor, NY 12553 4.Proposed Electrical Work/Fixture Count: Installation of(2) 13.5 kWh Energy Storage System. STATE OF NEW YORK, COUNTY OF WESTCHESTER ) as: Frank Saladino ,being duly sworn,deposes and states that he/she is the applicant above named,and does further (print name of individual signing as the applicant) state that(s)he is the legal owner of the property to which this application pertains,or that(s)he is the Contractor/electrician for the legal owner and is duly authorized to snake and file this application (indicate architect,contractor.agent,attomev,etc.) The undersigned further states that all statements contained herein are true to the best of his/her knowledge and belief,and that any work performed,or use conducted at the above captioned property will be in conformance with the details as set forth and contained in this application and in any accompanying approved plans and specifications,as well as in accordance with the New York State Uniform Fire Prevention&Building Code,the Code of the Village of Rye Brook and all other applicable laws,ordinances and regulations. Sworn to before me 's J- Swom t fore me this D day of j ,20 0 day of 20 Signature of Property Si Applicant Sean Coffey Frank a dino P=' Ne of Prrty er Print Name of Applicant V/ 1 YYY Notary Pub B Notary Publi NOTARY PUBLIC-STATE OF NEW YORK NO. 01 C06129832 AMY M.CONN Qualified it)Westchester County NOTARY PUBLIC,STATE OF NEW YORK Registration No.01C06327155 My Commission Expires 07-05-2025 Qualified in Orange County Commission Ex ires June 29,20 1 ,1 19 STATE WIDE INSPECTION SERVICES, INC. Service With Integrity ,•0 • • SWIS JOB APPLICATION •. • Office Use Elect, Permit# � ��_ �/7 7 Dace 3_12-0 Z y Bldg Permit# Sq Ft Plumbing Permit# Final Certificate# City/Village L I r U�1� Zip )65-73 Building Dept. 2� �rpd� County W1-54rfjeJ� Address 6 1`Z ;�G� 4JOOG� �r/t S Cross Street Section �3e5.3y Block Lot B Owner Name/Address(If different than above) S ea, C o-'e Contact Number S/6 —Z L//_YJ�7 ❑Basement 1st Fl. ❑2nd Fl. ❑3rd Fl. ❑More Than 3 Fl. ❑Garage ®Attic ❑Outside dResidential ❑Commercial Receptacles Special Recept GFCI AFCI Switches Dimmers Smoke Alarms C/0 Detector Hood Trash Compact Amt Amps Range(s) Cooktop(s) Oven(s) Dishwashers Refrigerator Disposal Microwave Luminaires Generator Transfer Switch SERVICE Amperage #Panels 1P 3P # Meters # Disconnect ❑Underground ❑ New ❑ Reconnect ❑ Repair ❑Overhead ❑Upgrade ❑ Disconnect Utility ID# ❑Con Ed ❑ NYSEG ❑Central Hudson ❑ Orange/Rockland PHOTOVOLTAIC SYSTEM PV Modules Inverters AC Disconnect Junction Box Combiner Box Load Center PV Monitor Energy Storage System DC Disconnect I 1 2— Legalization ❑ Safety Inspection ❑Consultation V-1 f ZCe 7i 2U0 This application is valid for one(1)year from the date received by SWIS.This application is intended to cover the above listed items to be inspected,if at anytime of inspection additional items have been installed,you are authorized to make the inspection and adjust the fee for the additional items inspected.The applicant declares that there is no open applications for the above address with any other inspection company.The applicant, owner or authorized agent agrees to all the above terms and conditions asset forth for the application. Email Address 0(,0i)k1 0 PS)H r C0 t^^ Name License # (� Date 3 6-2,Ll Signature �,/ Address 7 �U `�t(� } L� City/State Q�A/in U�SG� /V/ Zip Code 12 SZZS'3 Company CS�� ���� n 7Q ftMs l� Phone # State Wide Inspection Services 1080 Main Street _ SEP 3 0 2024 Fishkill, NY 12524 845 202-7224 Phone VILLAGE OF RYE BROOK 914-219-1062 Fax STATE WIDE INSPECTION SERVICES BUILDING DEPARTMENT Email: office(aOswisny.com Website: www.swisny.com Service With Integrity BY THIS CERTIFICATE OF COMPLIANCE STATE WIDE INSPECTION SERVICES CERTIFIES THAT: Upon the application of: Upon Premises Owned by: Tesla Energy Operations, Inc. Sean Coffey 1073 Route 94, Unit 4 Jaime Coffey New Windsor, NY 12553 67%Winding Wood Road South Rye Brook, NY 10573 Located at: 67 Y2 Winding Wood Road South, Rye Brook, NY 10573 Section: Block: Lot: Electrical Permit Number: EP24-077 135.34 1 38 Certificate Number: 2024-3931 Building Permit Number: A visual inspection of the electrical system was conducted at the Residential occupancy described below.The electrical system consisting of electrical devices and wiring is located in/on the premises at: 67 Y2 Winding Wood Road South, Rye Brook, NY 10573 The Photovoltaic System was inspected in accordance with the NYS and NFPA 70-2017 and the detail of the installation, as set forth below, was found to be in compliance on the 20"' day of June 2024. Name Quantity Rating Circuit Type Energy Storage Systems 02 Inverter 01 Disconnect 01 Load Center 01 Officer: Frank J. Farina This certificate may not be altered in any way and is validated only by the presence of a seal at the location indicated.This certificate is valid for work performed on the date of inspection only. ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE AC ALTERNATING CURRENT BLDG 1. THIS SYSTEM IS GRID—INTERTIED VIA A UL—LISTED ALL WORK TO COMPLY WITH SECTION R327 OF THE _ BUILDING CONC CONCRETE DC DIRECT CURRENT POWER—CONDITIONING INVERTER. 2020 RESIDENTIAL CODE OF NYS. ,' EGC EQUIPMENT GROUNDING CONDUCTOR (E) 2. A NATIONALLY — RECOGNIZED TESTINGFj EXISTING EMT ELECTRICAL METALLIC TUBING FSB LABORATORY SHALL LIST ALL EQUIPMENT IN FIRE SET—BACK GALV GALVANIZED GEC GROUNDING COMPLIANCE WITH ART. 110.3. ELECTRODE CONDUCTOR GND GROUND HDG HOT 3. WHERE ALL TERMINALS OF THE DISCONNECTING R1 DIPPED GALVANIZED I CURRENT ImpCURRENT AT MEANS MAY BE ENERGIZED IN THE OPEN POSITION, APR 2024 MAX POWER Isc SHORT CIRCUIT CURRENT kVA A SIGN WILL BE PROVIDED WARNING OF THE KILOVOLT AMPERE kW KILOWATT LBW LOAD HAZARDS PER ART. 690.17. C0UJ1'T y L.ICENSE0VILLAGE OF RYE BROOK BEARING WALL MIN MINIMUM (N) NEW NEUT 4. EACH UNGROUNDED CONDUCTOR OF THE �LEC1.RI(; BUILDING S PAR MENT NEUTRAL NTS NOT TO SCALE OC ON CENTER PL MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY R ��� PHASE AND SYSTEM PER ART. 210.5. EQV�R��'�'® PROPERTY LINE POI POINT OF INTERCONNECTION F��.E PV PHOTOVOLTAIC SCH SCHEDULE S STAINLESS 5. CIRCUITS OVER 250V TO GROUND SHALL COMPLY STEEL STC STANDARD TESTING CONDITIONS TYP WITH ART. 250.97, 250.92(B). OPY TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V 6. DC CONDUCTORS EITHER DO NOT ENTER BUILDING VOLT Vmp VOLTAGE AT MAX POWER Voc VOLTAGE OR ARE RUN IN METALLIC RACEWAYS OR AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT ENCLOSURES TO THE FIRST ACCESSIBLE DC DISCONNECTING MEANS PER ART. 690.31(E). ,`�OF NEw y 7. ALL WIRES SHALL BE PROVIDED WITH STRAIN KEGg O N� .A RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY *� UL LISTING. PERMIT# v _k o 8. MODULE FRAMES SHALL BE GROUNDED AT THE UL L# �� n I w — LISTED LOCATION PROVIDED BY THE �° m L" MANUFACTURER IN I '`: 2024 2cs� E USING UL LISTED GROUNDING DATE PPF � �� �5P1/21127 HARDWARE. AR 00 9. MODULE FRAMES, RAIL, AND POSTS SHALL BE opssslkoN BONDED WITH EQUIPMENT GROUND CONDUCTORS. BUILDING 41PE TOR,Village of Rye Brook,NY Digitally signed by William K William KLou Lou Date:2024.03.15 19:03:47-07'00' VICINITY MAP INDEX Sheet 1 COVER SHEET Sheet 2 SITE PLAN Sheet 3 THREE LINE DIAGRAM Sheet 4 BOS LAYOUT PHOTOS LICENSE GENERAL NOTES ��` Cutsheets Attached will 1. ALL WORK SHALL COMPLY WITH THE 2020 NYS ' UNIFORM CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2017 NATIONAL ELECTRIC CODE. 3. ALL WORK SHALL COMPLY WITH THE 2020 NYS FIRE CODE. MODULE GROUNDING METHOD: WEEB 4. ALL WORK SHALL COMPLY WITH THE 2020 BUILDING CODE OF NYS. ,-low REV BY DATE COMMENTS AHJ: Rye City 5. ALL WORK SHALL COMPLY WITH THE 2020 �`� REV A NAME DATE COMMENTS RESIDENTIAL CODE OF NYS. 6. ALL WORK SHALL COMPLY WITH THE 2020 ` UTILITY: Consolidated Edison EXISTING BUILDING CODE OF NYS. CONFIDENTIAL-THE INFORMATION HEREIN JOB NUMBER: JB-1 0 00 CUSTOMER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE Sean Coffey 27 KWH ENERGY STORAGE SYSTEM Zach Magalhaes TBENEFIT OF ANYONE EXCEPT TESLA INC.,NOR MOUNTING SYSTEM: E 5 LFi SHALL IT BE DISCLOSED IN WHOLE OR IN 67 1/2 Wi n d i n g w o o d Rd S PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION,EXCEPT IN CONNECTION NTH MODULES: Rye Brook, NY 10573 THE SALE AND USE OF THE RESPECTIVE TESLA EQUIPMENT,WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV: DATE- PERMISSION OF TESLA INC. 5162415197 COVER SHEET 1 3/5/2024 67 '12 Win . dingWood Rd S OF NFw KEG,q y0 � C r Iz (E) DRIVEWAY mLjj Front Of H }ouse �s EXP1131127 U95002.^% ROFESSIOX4 ;,- LEGEND M _ Q (E) UTILITY METER & WARNING LABEL Inv RELA Y AC INVERTER W/ INTEGRATED DC DISCO Inv & WARNING LABELS RELAY © AUTOMATIC RELAY (E) INVERTER VE3 DC DISCONNECT & WARNING LABELS AC AC DISCONNECT & WARNING LABELS ESS o DC JUNCTION/COMBINER BOX & LABELS 10 Ess ENERGY STORAGE SYSTEM FOR STAND ALONE OPERATION Q ESS DISTRIBUTION PANEL & LABELS Lc LOAD CENTER & WARNING LABELS M DEDICATED PV SYSTEM METER Rso RAPID SHUTDOWN STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR (E) PV CONDUIT RUN ON INTERIOR GATE/FENCE Q HEAT PRODUCING VENTS ARE RED INTERIOR EQUIPMENT IS DASHED L=J SITE PLAN N Scale: 1/8" = 1' W E 0 1' 8' 16' S CONFIDENTIAL-THE INFORMATION HERON JOB NUMBER: JB-1 0 00 CUSTOMER. DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE Sean Coffey 27 KWH ENERGY STORAGE SYSTEM Zach Magalhaes BENEFIT OF ANYONE EXCEPT TESLA INC.,NOR MOUNTING SYSTEM: T E 5 L n SHALL IT BE DISCLOSED IN WHOLE OR IN 67 1/2 Wi n d i n g w o o d Rd S TS ORGA IZ►°o,EXCEPT IN CONNECTIONERS OUTSIDE THE WITH MODULES. Rye Brook, NY 10573 THE SALE AND USE OF THE RESPECTIVE TESLA EQUIPMENT,WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV: DATE: PERMISSION OF TESLA INC. 5162415197 SITE PLAN 2 3/5/2024 (N) 200A INTERNAL r———E E, AC POWERWALL HAS A BUILT IN INVERTER TESTED TO UL 1741 STANDARDS (E)WIRING AC GATEWAY AC DISCONNECT LOAD CENTER )INVERTER EXISTING 6.76 KW DC SYSTEM SIZE, MAIN SERVICE PANEL ENERGIZED FROM UTILITY AND BATTERY STORAGE 200A 2P Ai B 35A 2p (E)MODULES 175A POWERWALL MODES OF OPERATION ARE TIME BASED CONTROL OR BACK UP 4 3 - �.n ___ - i ONLY. (26)TRINA SOLAR 260W MODULES L(1)ZIGBEE 6 KW INVERTER----------------------J 1 602P 2 D POWERWALL TO 120/240V 200A 2P 60A 2P Q�� K E G,q yO SINGLE PHASE 2 D POWERWALL �P� Nei' UTILITY SERVICE _ * <0 • The contacts will r— G (E)LOADS remain open when n ) w LU the system loses (E)200A contact with the (P EXP 1131127 C? DISTRIBUTION utility grid �� U9�002,� v PANEL RoFES S,ON,P Ref Qty Description Sze(AWG) Min EGC Conduit Length Imp Vmp Ref Type Qt 1 Ponelboard Accessory Kit for GW 2.0 NA: 200A,6sp/12cir,120/24OV,1PH y (Cu) (AI) (AWG,Cu) (Cu) (Al) (ft) (AAC) (VAC) 1 Breaker, 35A/2P,2 Spaces 1 THWN-2 3 #2/0 #4/0 #06 2"PVC 2'PVC 2ft — 240 A 2 Breaker, 60A/2P,2 Spaces 2 TH0-2 3 #06 #04 110 PVC Jacketed MC 1"EMT 2ft — 240 1 200A Main Circuit Breaker, 2—Pole,24OV,1OkAIC 3 THWN-2 3 #2/0 #4/0 106 2"PVC 2*PVC 2ft — 240 1 Tesla#1232100-00—G: Back—up Gateway 2.0 NA 4 THWN-2 3 #2/0 #4/0 #06 2°PVC 2'PVC 5ft — 240 1 Disconnect; 200A,240Vac,Fusible,NEMA 3R: 2P,3W,Lockable 1. GROUND NEUTRAL BOND TO BE COMPLETED IN SERVICE EQUIPMENT(A) 2.CONDUIT RUNS MAY BE CONDENSED DUE TO SITE CONDITIONS AND/OR B 1 Ground/Neutral Kit; 200A General,Heavy Duty(DG,DH),NEMA 1,3R INSTALLATION EASE. ALL CONDUIT FILL DERATES AND PROPER CALCULATIONS 2 Fuse; 175A,250V,Class RK5: Time Delay,200kA I.R. HAVE BEEN COMPLETED PER NEC CHAPTER 9, TABLE 4. 1 Class R Fuse Kit 3. SOLAR SHUTDOWN DEVICE TO BE INSTALLED FOR SYSTEM RAPID SHUTDOWN (RSD)IN ACCORDANCE WITH ARTICLE 690 OF THE APPLICABLE NEC. D 2 Powerwall 3[240V) 1707000-25—G 11.5 kW/13.5 kWh 4.CONDUIT TYPE CAN CHANGE DUE TO SITE CONDITIONS AND WILL FOLLOW THE NEC REQUIREMENTS FOR THAT CONDUIT TYPE. SITE SPECIFICATONS, Main Panel Rating (E)200A Main Breaker (E)200A Rating General Notes DC Ungrounded Inverters Panel Number Meter Number 012062426 Service Entrance Overhead CONFIDENTIAL—THE INFORMATION HEREIN JOB NUMBER: JB-1 0 00 CUSTOMER. DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE Sean Coffey 27 KWH ENERGY STORAGE SYSTEM Zach Magalhaes T E 5 L n BENEFIT OF ANYONE EXCEPT TESLA INC.,NOR MOUNTING SYSTEM: SHALL IT BE DISCLOSED IN WHOLE OR IN 67 1/2 Wi n d i n g w o o d Rd S PART TO OTHERS OUTSIDE THE REPIENTS ORGANIZATION,EXCEPT IN CONNECTION VATH MODULES: Rye Brook, NY 10573 THE SALE AND USE OF THE RESPECTIVE TESLA EQUIPMENT,WITHOUT THE WRITTEN INVERTER: PAGE NAME SHEET. REV: DATE PERMISSION OF TESLA INC. 5162415197 THREE LINE DIAGRAM 1 3 3/5/2024 + L I NIE KEG q 0,9 <10 f r_ Q lwj A� 2 !~ N� EXP 113JI27 C? 095002-� gw —srl A90FESS10NP� � _— Y �now -pm . - se • or Ar, WO ' s 1 0" APART - 65 de al mw N 1 CONFIDENTIAL—THE INFORMATION HEREIN JOB NUMBER: JB-1 0 00 CUSTOMER. DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE Sean Coffey 27 KWH ENERGY STORAGE SYSTEM Zach Magalhaes BENEFIT OF ANYONE EXCEPT TESLA INC.,NOR MOUNTING SYSTEM: TESL � n SHALL IT BE DISCLOSED IN WHOLE OR IN 67 1/2 Wi n d i n g w o o d Rd S PART TO OTHERS THE RECIPIENTS ORGANIZATION,EXCEPT ION CONNECTION WITH MODULES: Rye Brook, NY 10573 THE SALE AND USE OF THE RESPECTIVE TESLA EQUIPMENT,WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV: DATE PERMISSION OF TESLA INC. 5162415197 B O S LAYOUT PHOTOS 4 3/5/2024 L Label Location: Label Location: BACKUP ' (BLC) CAUTION (MSP) Per Code: TRI POWER SOURCEPer Code: NEC 408.4 SECO�ND •, ' PHOTOCE IS ENERGY STORAGE VOLT,IC SYSTEM NEC 705.12(B)(3) SYSTEM Label Location: CAUTION (BLC) .•NOT ADD NEW LOADSPer Code: Label Location: NEC 220 WARNING (MSP) Per Code:BY I ,`�OF NEW y THIS NEC 705.12.B.2.3.c �Q, KEGgN O Label Location: MULTIPLERATING• •F ALL• •• • CURRENT v CAUTION (MSP) DEVICES, . q: THIS PANEL HAS SPLICED FEED- Per Code: • D 0 w •• CONDUCTORS. NEC 312.8.A(3) • - �' m OF Z • • • • • EXP 1/31/27 C? ��STORAGE BACKUP LOAD PANEL ,o U95002''N ROFESS%012(Y240�c NP • VOLTAGEMINAL ESS Label Location: Label Location: (MSP) • • (MSP) MAX AVAILABLE: •' Per Code: DUAL POWER SOURCEPer Code: G[RCUIT FROMPer 706.7(D) label to be marked in field SECOND •ENERGY STORAGE SYSTEM NEC 705.12(B)(3) ■C FAULT ,■ ING TIME • • DATE OF i a Label Location: ENERGY O. (MSP) LOCATED WITHIN LINE OF SIGHT Per Code: Label Location: ENERGY STORAGE (MSP) D ON ADJACENTPer Code: Label Location: ENERGY STORAGE (MSP) OPPOSITELOCATED ON Per Code: Label Location: �.. SYSTEM, SITE (MSP) LOCATED INSIDE Per Code: (AC):AC Disconnect (BLC):Backup Load Center (MSP):Main Service Panel ST-Standard Label Set POWERWALL Backup Gateway 2 I he )(_,-I0Wi`y 2 for lesli=l ow(..`rwi ll plvvldes eller(ly niZzlia(lellwill .r y 5 L rl i:110 II)o1illOI'111O fo i-Sok-1'Self-colIS(II III')I.IOI1,llrile-l1i:Se'I CUIILrOI,i.:I1C1 ha(:kllp. I Rpcktip Cizzle\,vay 2 C(�iilr()IS(:(.)Iiiiectioi)to Hw Y1.1,I.c(It.u1nallcally Iel('cllllc�()llti?,_JeS i:tl(1 I)r()vl(IIII()a Seamless Iu,zlisill()II to hacklll)I)(')W(`I'. \/\/Ilell c(Itli;)I�ed With(-=11)a(1 c:irC(iit l)roi:kor.the kacktll)Gat.ewc?y 2(:c.:ii he 11ISti:I1ed i=l the service eldfi.:llce.\/\/IWII the C)I,AIC 11i:l 111WI-Wd 0(i 11e150i'I'd IS IlisLi:lle(I•(.lie (ii:le\,k,i:y 2 ci.il is so fmiclioii i:S ZzI()i:(I ceiiier. I he BizC:klll)()i:leway,2 colTlrllllllici:tes directly Powerw(-ll, yC)l! L()11wilit()r eller!Jy(Is(;all(I hackol i eilergy resc!rveS from tally fllo)Ile devlce will the le>li-i=L�L). PERFORMANCE SPECIFICATIONS MECHANICAL SPECIFICATIONS Model Number YY Dimensions AC Voltage(Nominal) Weight Feed-In Type Mounting options Grid Frequency Current Rating Maximum Input Short Circuit Current Overcurrent Protection Device Overvoltage Category AC Meter T o 9 L R Primary Connectivity Secondary Connectivity User Interface 660 Operating Modes o Backup Transition Modularity Optional Internal Panelboard Warranty 411 149 COMPLIANCE INFORMATION ENVIRONMENTAL SPECIFICATIONS Certifications Operating Temperature �A Operating Humidity(RH) Emissions Maximum Elevation Environment Enclosure Type Powerwall 3 Powerwall 3 Technical Specifications Power Everything System Technical Model Number 1707000-xx-y Specifications Nominal Grid Voltage(Input&Output) 120/240 VAC Powerwall 3 is a fully integrated solar and battery system,designed to accelerate the transition to sustainable energy. Grid Type Split phase Customers can receive whole home backup,cost savings,and energy independence by producing and consuming their own energy while participating in grid services.Once installed customers can manage their system using the Tesla App to customize Frequency 60 Hz system behavior to meet their energy goals. Overcurrent Protection Device Configurable up to 60 A Powerwall 3 achieves this by supporting up to 20 kW DC of solar and providing 11.5 kW AC of continuous power per unit.It has Solar to Battery to Home/Grid Efficiency 89%12 the ability to start heavy loads up to 185 A LRA,meaning a single unit can support the power needs of most homes.Powerwall 3 Solar to Home/Grid Efficiency 97.5%3 is designed for mass production,fast and efficient installations,easy system expansion,and simple connection to any electrical Supported Islanding Devices Backup Gateway 2,Backup Switch service. Connectivity Wi-Fi(2.4 and 5 GHz),Dual-port switched Ethernet, Cellular(LTE/4G4) Hardware Interface Dry contact relay,Rapid Shutdown(RSD)certified switch and 2-pin connector,RS-485 for meters AC Metering Revenue Grade(+/-0.5%) Protections Integrated arc fault circuit interrupter(AFCI), Isolation Monitor Interrupter(IMI),PV Rapid Shutdown(RSD)using Tesla Mid-Circuit Interrupters Customer Interface Tesla Mobile App Warranty 10 years Solar Technical Maximum Solar STC Input 20 kW Specifications Withstand Voltage 600 V DC PV DC Input Voltage Range 60—550 V DC :=E:r PV DC MPPT Voltage Range 150—480 V DC MPPTs 6 Maximum Current per MPPT(Imp) 13 A s Maximum Short Circuit Current per MPPT(ISM) 15 A s Battery Technical Nominal Battery Energy 13.5 kWh AC Specifications Maximum Continuous Discharge Power 11.5 kW AC Maximum Continuous Charge Power 5 kW AC Output Power Factor Rating 0-1(Grid Code configurable) Maximum Continuous Current 48 A Maximum Output Fault Current 10 kA Load Start Capability(1 s) 185 A LRA Power Scalability Up to 4 Powerwall 3 units supported Typical solar shifting use case. Values provided for 25°C(77°F),at beginning of life.3.3 kW charge/discharge power. 'Tested using CEC weighted efficiency methodology. 'Cellular connectivity subject to network service coverage and signal strength. 5 Where the DC input current exceeds the MPPT rating,a jumper can be used to combine two MPPTs into a single input to intake DC current up to 26 A IMF,/30 A ISG, 2024 2024 Powerwall 3 Datasheet Powerwall 3 Technical Specifications Powerwall 3 Example System Configurations Environmental Operating Temperature -200C to 500C(-4°F to 1220F)6 Powerwall 3 with Backup Switch Specifications Operating Humidity(RH) Up to 100%,condensing Whole Home Backup _ Storage Temperature -200C to 300C(-4°F to 860F),up to 95%RH,non- I dpiional condensing,State of Energy(SOE):25%initial I Maximum Elevation 3000 m(9843 ft) � I Environment Indoor and outdoor rated Backup Switch I Enclosure Rating NEMA 3R ( Solar Ingress Rating IPX7(Battery&Power Electronics) IPX5(Wiring Compartment) Pollution Rating PD3 _j I MeterIL Operating Noise a 1 m <50 db(A)typical <62 db(A)maximum Grid Meter socket panel Load center Performance may be de-rated at operating temperatures above 400C(1040F). I Compliance Certifications UL 1642,UL 1699B,UL 1741,UL 1741 SA, UL 1741 SB, 1=/ Information UL 3741,UL 1973,UL 1998,UL 9540, IEEE 1547-2018,IEEE 1547.1,UN 38.3 Backup loads Powerwall 3 Grid Connection United States Emissions FCC Part 15 Class B Environmental RoHS Directive 2011/65/EU Seismic AC156,IEEE 693-2005(high) Powerwall 3 with Backup Gateway 2 Fire Testing Meets the unit level performance criteria of UL 9540A Partial Home Backup Optional Mechanical Dimensions 1099 x 609 x 193 mm(43.25 x 24 x 7.6 in) I I , I Specifications Weight 130 kg(287 lb) Utility Meter I I Mounting Options Floor or wall mount I Solar l Main - Breaker -- -- -- o O Grid Meter load center Backup Gateway 2 Load center I I 1099 mm Non-essential loads Backup loads Powerwall 3 609 m 193 m � �mm 2024 2024 Powerwall 3 Datasheet