CERTIFICATE OF COMPLIANCE
February 6,2024
Andrew Laterza&Sumathi Laterza
8 Country Ridge Circle
Rye Brook,New York 10573
Re: 8 Country Ridge Circle, Rye Brook,New York 10573
Parcel ID#: 129.74-1-26
This document certifies that the work done under Mechanical Permit#23-180 issued on 12/22/2023 for the
installation of two new gas fired furnaces have been satisfactorily completed.
Sincerely,
Steven E. Fews
Building&Fire Inspector
/to
�yE BRC�k•
1932 BUILDING DEPARTMENT
❑BUILDING INSPECTOR
C�ASSISTANT BUILDING INSPECTOR VILLAGE OF RYE BROOK
❑CODE ENFORCEMENT OFFICER 938 King Street. Rye Brook,NY 10573
(914) 939-0668 FAx (914) 939-5801
www ryebrook.org
- - - - - - - - - - - - - - - - - - - - INSPECTION REPORT - - - - - - - - - - - - - - - - - - - -
ADDRESS : '9 l _,o u K)-T `` 7 \\ �� `�C L E DATE: 1 - 30 - 2-0 L'/
PERMIT# M P Z. 3` ) o 0 ISSUED: 12- L2-23 SECT: 1 i 7 BLOCK: 1 LOT: Z(D
LOCATION: 5 F l ^ 1 E /V r OCCUPANCY:
❑ Violation Noted THE WORK IS... 121 PASSED ❑ FAILED REINSPECTION
❑ SITE INSPECTION REQUIRED
❑ FOOTING
❑ FOOTING DRAINAGE
❑ FOUNDATION
❑ UNDERGROUND PLUMBING NOTES ON INSPECTION:
❑ ROUGH PLUMBING
❑ ROUGH FRAMING
❑ INSULATION
0 Natural Gas '�►�� �� i L t F Z c, S r �F
❑ L.P. Gas F yk r ry c c S
❑ FUEL TANK
❑ FIRE SPRINKLER
❑ FINAL PLUMBING
❑ CROSS CONNECTION
2-TINAL
❑ OTHER
O o �
00
w
N NN
.--Icn
z w
Fri W U
w a (U „� � � W
c/� o 0 -d v ° r00
x
u A , :3
cn
a
Iz
i � o � � aen z
Er
u cc
71
jg G
° � � w° �
00
v
o 0 -9
- wo Z ti x z Uz � � t. ° z
H 1 v" � -v (� a
c!a cn o ptz
°°Ca u
v W
00 CT 'J W cn 5 � a0 °
moo
En
_ � �j "►�, � V d' O y � �&500 � s
M � .
N
a. � P a•"
00 W Cd " as
BUILD DEPARTMENT
VIL f E OF RYE BROOK ;DEC 2 2
938 KING ET RYE BROOK,NY 10573 2Qz3
{ -0668 VILLAGE OF RYE BROOK
k or BUILDING DEPARTMENT
llyu___--'
APPLICATION FOR PERMIT TO INSTALL AND/OR REMOVE
HEATING, VENTILATION AND/OR AIR CONDITIONING EQUIPMENT
FOR OFFICE USE ONLY: PERMIT#: �3 / GT C
Approval Date: DEC 2 Permit Fee: $ D/ —p
Approval Signature: Other:
Disapproved:
(fees are non-refundable)
**,t,tttt****�rrrr,rw*r*x*,e*,r**sr*�e*+r,r+r,r***,t*+r+r+r,tat*�*+k*+r*+►+k+k+r+tf**,r,r*:r*,r+�***,r**********,a*******�,r�*�*r***�*,tt
DO NOT START WORK or CONSTRUCTION UNTIL A PERMIT HAS BEEN ISSUED BY] I I E BUILDING
INSPECTOR.THE ADMINISTRATIVE FEE FOR WORK PROGRESSED OR COMPLETED WITHOUT A PERMIT IS
12%OF THE TOTAL COST OF CONSTRUCTION WITH A MINIMUM FEE OF$750.00
REQUIREMENTS FOR RELEASE OF PERMIT&CERTIFICATE OF COMPLIANCE:
1. Properly completed&Signed Application.
2. Site/Staging Plan if Required by the Building Inspector.
3. Copy of Licensed Contractor's Liability Insurance.(Village of Rye Brook must be listed as certificate holder) & Workers
Compensation Insurance on a NYS Board form(Form#C 105.2 or Form#U26.3/or NY State Workers Compensation Waiver)
4. Payment of Fees/Unit: RESIDENTIAL=$100.00/unit•COMMERCIAL=$350.00/unit.
5. Complete specifications for each unit being installed.
6. Inspection by the Building Department for removal and/or installation.(48 hour notice required)
7. Electrical work requires a separate Electrical Permit&Electrical Inspection.
8. Plumbing/Gas work requires a separate Plumbing Permit&Plumbing Inspection.
Application dated, 12- 22 25 is hereby made to the Building Inspector of the Village of Rye Brook for a permit for the
installation and or removal ot the HVAC equipment as listed below.The applicant and property owner,by signing this document
agrees that said equipment will be installed and/or removed in conformance with all applicable Local,County,State&Federal laws,
codes,rules and regulations.
1. Address:?2 COur-A'ry�� r_ CkCcke SBL: I21•,y - l- 2Co Zone:
2. Property Owner: A cen-a L Q ('c zo, Address:-2 eo�rti
Phone#: 9yi 0,69 -yt 9 Cell#: email:
3. Contractor: Cc.m[J1,i Address: ri toszs
Phone#: 9t,-1 S$O - Cell#: email: Qecfni#5 nr'x4m
4. Scope of Work:New Installation{ )•Replacement tv •Removal( )•Other( ):
5. List Equipment: 'Re p,C�Ce,ry-er�-V 0� -t'43o L2>�Xt 1�nC_ PS5 ' �it� u cn,Q�tS
6. Location of Equipment: .�e �-
7. Method of Installation/Removal(list all equipment needed to perform job):
t
10/30/2023
STATE OF NEW YORK,COUNTY OF WESTCHESTER ) as:
being duly sworn,deposes and states that he/she is the applicant above named,
(print name of individual signing as the applicant)
and further states that(s)he is the Heating,Ventilation and/or Air Conditioning Contractor for the legal owner and is duly
authorized to make and file this application.
That all statements contained herein are true to the best of his/her knowledge and belief,and that any work performed,or use
conducted at the above captioned property will be in conformance with the details as set forth and contained in this application
and in any accompanying approved plans and specifications,as well as in accordance with the New York State Uniform Fire
Prevention&Building Code,the Code of the Village of Rye Brook and all other applicable laws,ordinances and regulations.
Sworn to before me this Z Z Sworn to before me this
to 2�
day of LJ-e.Ce r%+)0-e r,20 23 day of 1�JP�e►^r+bt C,20 2'�
Z
ign ture o operty er Slgna Ire of Applicant
Print Name of Property Owner Print Name of Applicant
No Public Notary Public
DIANE M HOWIE Ead
HOWIE
Notary Public State of New York tate of New York
No
No. 6391666
Qualified in Westchester County tchester County
My Commission Expires May 13,2027 pires May 13,2027
own
This application must be properly completed in its entirety and must include the notarized signature(s)of
the legal owner(s)of the subject property, and the applicant of record in the spaces provided. Any
application not properly completed in its entirety and/or not properly signed shall be deemed null and void
and will be returned to the applicant.
2
10/30/2023
AHeating&ana A M900 /AC900
HEATING INPUT.• 40,000-120,000 BTU/H TWO-STAGE, 9-SPEED ECM
GAS FURNACE
80%AFUE
Contents
Nomenclature........................................2
Product Specifications...........................3
Dimensions............................................5
Airflow Data...........................................7
Wiring Diagram ...................................23
_ Accessories..........................................24
t
Standard Features Cabinet Features
• Two-stage gas valve provides quiet, • Fully insulated,heavy-gauge steel cabinet
economical heating with durable baked-enamel finish
• Efficient and quiet multi-speed ECM circulator motor • Multi-position installation:
• SureStart®Silicon Nitride igniter AM9C80:upflow,horizontal left or right
designed for long igniter life AC9C80:downflow,horizontal left or right
• Self-diagnostic control board • Removable bottom for side-or
• Low constant fan speed circulates air bottom-return applications
throughout the home • Convenient left or right connection
• Quiet,two-speed induced draft blower for gas/electric service
• California Low NOx emissions-compliant • Cabinet air leakage 5 2%
models available • Coil and furnace fit flush
• Can no longer be installed in California's for most installations
South Coast Air Quality Management District
(SCAQMD)on or after October 1,2019.
• AHRI Certified;ETL Listed
�j�� W carwnwrm
CERIkMo o . BL C6flN�l OL
V •pp 9ppl• •»p 1�.
Intertek
•Complete warranty details available from your local dealer or at www.amana-hac.com.To receive the
lifetime Unit Replacement Limited Warranty(good for as long as you own your home)and 10-Year Parts
Limited Warranty,online registration must be completed within 60 days of installation.Online registration
is not required in California or Quebec.
SS-AM9C80/AC9C80 www.amana-hac.com 8/21
Amana•is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company,L.P.,Houston,Texas.
NOMENCLATURE
A M 9 C 80 040 4 C * *•
1 2 3 4 5,6 7,8,9 10 11 12 13,14
BRAND
ENGINEERING
A-Amana*Brand Major/Minor Revisions
A-Initial Release
B-1st Revision
CONFIGURATION NOX
M-Upflow/Horizontal N=>40 NG/1 NOx
C-Downflow/Horizontal X=<40 NG/J NOx
MOTOR CABINET WIDTH
9- Nine Speed ECM A-14" C-21"
8-17%" D-24%"
GAS VALVE MAXIMUM CFM
C-2 Stage 3-1200 CFM 4-1600 CFM
5-2000 CFM
AFUE MBTU/H
80-80%AFUE 92-92%AFUE 030-30,000 BTU/h 080-80,000 BTU/h
96-96%AFUE 97-97%AFUE 040-40,000 BTU/h 100-100,000 BTU/h
060-60,000 BTU/h 120-120,000 BTU/h
2 www.amana-hac.com SS-AM9C80/AC9C80
SPECIFICATIONS
HEATING CAPACITY
High Fire Input(BTU/h)' 40,000 60,000 80,000 90,000 80,000 80,000 80,000 100,000
High Fire Output(BTU/h)'
Natural Gas 32,000 48,000 64,000 64,000 64,000 64,000 64,000 80,000
LP Gas 32,000 48,000 64,000 64,000 64,000 64,000 64,000 80,000
Low Fire Input(BTU/h)' 28,000 42,000 56,000 56,000 56,000 56,000 56,000 70,000
Low Fire Output(BTU/h)'
Natural Gas 22,400 33,600 44,800 44,800 44,800 44,800 44,800 56,000
LP Gas 22,400 33,600 44,800 44,800 44,800 44,800 44,800 56,000
AFUE' 80 80 80 80 80 80 80 80
Available AC@0.5"ESP 1.5-3.0 1.5-4.0 3.0-4.0 2.0-5.0 2.5-5.0 2.5-5.0 2.5-5.0 2.0-5.0
Temperature Rise Range(°F) 15-45/15-45 15-45/15-45 30-60/30-60 30-60/30-60 25-55/25-55 25-55/25-55 20-50/20-50 25-55/25-55
CIRCULATOR BLOWER
Size (DxW) 10"x6" 10"x8" 10"x8" 10'x10" 10"x10" 10"x10" 11"x10" 10"x20"
Horsepower-RPM 1/2 1/2 1/2 3/4 3/4 1 1 1
No.of Burners 3 3 4 4 4 4 4 5
ELECTRICAL DATA
Min.CircuitAmpacity3 8.7 8J 8.7 12.45 12.45 1532 15.32 15.32
Max.Overcurrent Device(amps)' 15 15 15 15 15 20 20 20
SHIP WEIGHT(LBS) 105 107 118 121 129 129 129 124
Natural Gas BTU/h;for altitudes 0-45W above sea level,reduce input rating by 4%for each 10D0'above 4500'altitude.
' DOE AFUE based upon Isolated Combustion System(ICS)
' Minimum Circuit Ampacity=(1.25 x Circulator Blower Amps)+ID Blower amps.Wire size should be determined in accordance with National Electrical Codes.Extensive wire runs
will require larger wire sizes.
" Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size.May use fuses or HACR-type circuit breakers of the same size as noted.
NOTES
• All furnaces are manufactured for use on 115 VAC,60 Hz,single-phase electrical supply.
• Gas Service Connection%'FPT
• Important:Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all
existing local codes.
SS-AM9C80/AC9C80 www.amana-hac.com 3
SPECIFICATIONS
HEATING CAPACITY
High Fire Input(BTU/h)' 40,000 60,000 60,000 80,000 80,000 100,000
High Fire Output(BTU/h)'
Natural Gas 32,000 48,000 48,000 64,000 64,000 80,000
LP Gas 32,000 48,000 48,000 64,000 64,000 80,000
Low Fire Input(BTU/h)' 28,000 42,000 42,000 56,000 56,000 70,000
Low Fire Output(BTU/h)'
Natural Gas 22,400 33,600 33,600 44,800 44,800 56,000
LP Gas 22,400 33,600 33,600 44,800 44,800 56,000
AFUE2 80 80 80 80 80 80
Available AC @ 0.5"ESP 1.5-3.0 1.5-4.0 1.5-4.0 2.0-5.0 2.5-5.0 2.0-5.0
Temperature Rise Range(°F) 15-45/15-45 25-55/25-55 25-55/25-55 30-60/30-60 30-60/30-60 20-50/20-50
CIRCULATOR BLOWER
Size (D x W) 10"x 6" 10"x 6" 10"x 8" 10"x 10" 10"x 10" 10"x 10"
Horsepower-RPM 1/2 1/2 1/2 3/4 1 1
No.of Burners 3 3 3 4 4 5
ELECTRICAL DATA
Min.Circuit Ampacitya 8.7 8.7 8.7 12.45 15.32 15.32
Max.Overcurrent Device(amps)' 15 15 15 15 20 20
SHIP WEIGHT(LBS) 105 107 107 1121 1129 1131
Natural Gas BTU/h;for altitudes 0-4500'above sea level,reduce input rating by 4%for each 1009 above 4500'altitude.
' DOE AFUE based upon Isolated Combustion System(ICS)
' Minimum Circuit Ampacity=(1.25 x Circulator Blower Amps)+ID Blower amps.Wire size should be determined in accordance with National Electrical Codes.
Extensive wire runs will require largerwire sizes.
4 Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit
breaker size.May use fuses or HACR-type circuit breakers of the same size as noted.
NOTES
• All furnaces are manufactured for use on 115 VAC,60 Hz,single-phase electrical supply.
• Gas Service Connection%"FPT
• Important:Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes.
4 www.amana-hac.com SS-AM9C80/AC9C80
AM9C80 DIMENSIONS
Alternate Gas Inlet IIIIt` 13/4, A 17/JI Alt.Flue Outlet—Horizontal Left
I 6"
B 19'/::"
1
33W
Alt.Gas Inlet
2T/:
High-Voltage Inlet- 20" Q 235/,6" Alt.High Voltage
0
Low-Voltage Inlet
Alt.Low Voltage
28" .I 23„
MODEL DIMENSIONS
AM9C800403AN 14" 12W
AM9C800603BN 17W 16"
AM9C800803BN 17'W 16"
AM9C800804BN 17W 16"
AM9C800804CN 21" 19f"
AM9C800805CN 21" 19%"
AM9C800805DX 24W 23"
AM9C801005CN 21" 19%"
AM9C801205DN 24W 23"
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
VENT
SIDES REAR FRONT i BOTTOM Top
SW B
1 0 3 C 6 1 1
C=If placed on combustible floor,the floor MUST be wood ONLY.
No7es:
• For servicing or cleaning,a 24"front clearance is recommended.
• Unit connections(electrical,flue,and drain)may necessitate greater clearances than the minimum clearances listed above.
• In all cases,accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater.
• Refer to the appropriate USA and Canadian codes:
— In the USA:the National Fuel Gas Code NFPA 54/ANSI Z223.1
— In Canada:the Canada National Standard of Canada,CAN/CSA 13149.1 and CAN/CSA B142.2
SS-AM9C80/AC9C80 www.amana-hac.com 5
ACSIC80 DIMENSIONS
28" A
B
High-Voltage '
Electrical
Low-Voltage
Electrical
O
00 ,
Gas Inlet 33Ys"
18%,
o0MODEL DIMENSIONS
0 0 0
AC9C800403AX 14" 12f"
AC9C800603AX 14" 12%"
AC9C800603BX 17%" 16"
AC9C800804BX 17%" 16"
AC9C8008050X 21" 19%11
ACK8010050X 21" 19f"
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
FRONTSIDES REAR BOTTOM VENT Top
1 0 3 C 6 1 1
C=If placed on combustible floor,the floor MUST be wood ONLY.
Iiii
• For servicing or cleaning,a 24'front clearance is recommended.
• Unit connections(electrical,flue,and drain)may necessitate greater clearances than the minimum clearances listed above.
• In all cases,accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater.
• Refer to the appropriate USA and Canadian codes:
— In the USA:the National Fuel Gas Code NFPA 54/ANSI Z223.1
— In Canada:the Canada National Standard of Canada,CAN/CSA B149.1 and CAN/CSA B142.2
6 www.amana-hac.com SS-AM9C80/AC9C80
L woo•:)ey-euewe•mmm 08D6DV/08J6NV-SS
033dS iinVd30 v MON
9LST 8T9T SS9T S69T ££LT TLLT SORT S178T 60d
TEVT ELVT ZTST 4SST S6ST ZE9T 999T OTLI sod
9LST LSST 96ST 6E91 SL9T LILT TSLT S8LT LOd
SLOT VZTT LLTT 6ZZT LLZT VZET SLET 9ZVT 90d
L9ZT ETET 8SET TOVT LVVT 17617I 6EST 88ST sod IA/A *04080
OSJ6 W V
8Z6 VL6 BZOT TSOT 9ETT T6TT 6VZT EOET 40d
00£ EVE SO4 TOS RES IL9 OSL TER EOd
S6TT LEZT VSZT SZET ZLEI 8T17T S94T 8TSI ZOd
£Z8 ESE 9E6 686 S40T EOTT 8STI VIZI IOd
EZ91 OS9T 6L9I SOLT 6ELT £LLT ZTST ES8T 603
EVE 9LET 60VT OVVT VLVI ROST 8VSI E6ST 803
ZVST OLSI I09T SZ9T T99T S69T SELT 9LLT LOd
OOET SEET 89ET TOVT SEVT 69171 OTST ESST 90d
LEZT 69ZT EOEI 9EEI ELET L04I L"T 0617T sod TA/A +BOOK
OSJ6 W V
VEOI ZLOT VTTI OSTT 68TT 9ZZT L9ZT IT£T vVOd
V/N V/N L9E 6E7 US S6S LS9 T178 E03
SZTT 49TT 66TI EEZT OLZT 60EI L4ET S6ET ZOd
178L TES ON SZ6 896 NOT 9SOT VOTT TOd
98ZT LTET OSET ESET ST4i ZS4I 88VT EEST 60d
OOZT BUT OLZT ZOET TVEI 9LET VTVI 9SVT SOd
8ZOT L901 ZOIT OVIT SLIT 91ZT SSZT 86ZT LOd
9Z9 E89 VEL S8L 9ES ON IE6 LL6 901
EZ6 V96 SOOT SVOT ESOT VZTT 99TT 60ZI sod IA/A *SEOSO
OSD6WV
ZES 9L8 OZ6 6S6 TOOT SVOT 160T 8EIT vVOd
VLZ VIE L9E ZEV STS 08S 9179 OIL EOd
OVTT SLTT 60ZT TVZT SLZT VIET ZSET T6EI ZOd
SOL TSL 66L 8V8 S68 OV6 S86 9EOT TOd
98ZT LIST 6V£I L8ET 61VT 6SVI OOST "ST 603
ELOT LSOT SZTT I9TT V6TI ZEZT 09ZT 69ZT SOd
ES6 066 SZOT 690T OTIT ESTT 8611 ZSZT LOd
595 9T9 E89 9EL 98L OE8 US ZZ6 903
89TT LETT VZZT 09ZT 98ZT LIET S4ET OLET Sod IA/A *SE090
OSD6 W V
168 EE6 696 Z00T 6EOI 9LOT ETTT 91711 vVOd
ETE 6SE ET4 8917 Z7S VT9 099 OZL EOd
TIN Z17ZT OLZT ZO£T OEET 09£T 9SET ETVT ZOd
E98 606 L176 EL6 ETOT ZSOT 680T SZTT TOd
BUT 19ZT SEZI VIET 9EEI 6SET OSEI LTVT 60d
ZVTT 89TI S611 EZZI TSZT ELZT S6ZT 0£ET ROd
090T NOT 6TTT LYTT 6LTT ENT SEZI OLZI LOd
S49 T89 TZL 09L 008 048 TER SZ6 903
SE6 V96 966 VZOI LSOT 0601 EIIT ESTT sod WA +VEOVO
OS76WV
Z09 T49 8L9 61L 09L 008 TVs ZEE vVOd
V/N V/N SEE S6E L" TOS ESS V85 EOd
S68 9Z6 LS6 166 ZZOT 6SOT 060T OETT ZOd
90V 65V 60S VSS L09 Z59 L69 6VL Tud
(NAnio:)
M0131V ONIIO03 •
VIVO M01381V 9N11003 39VIS M07 08J611Vb'
AM9C80 LOW STAGE COOLING AIRFLOW DATA (CONT.)
COOLINGLOW STAGE
EXTERNAL STATIC PRESSURE,(INCHES WATER COLUMN)
FOl 1420 1359 1301 12S4 1206 1152 1100 1044
F02 1825 1769 1718 1673 1629 1584 1540 1497
F03 826 744 661 573 485 399 339 N/A
F04A 1623 1567 1516 1 1468 1423 1374 1328 1281
AM 9C80 Y/V1 F05 1697 1644 1596 1551 1505 1457 1413 1367
0805C*
F06 1741 1686 1639 1592 1550 1504 1462 1417
F07 1906 1855 1809 1763 1722 1682 1641 1597
F08 1966 1914 1869 1825 1782 174S 1703 1660
F09 2201 1 2152 2107 2073 1 2034 1996 1962 1925
FO1 1175 1109 1044 977 905 830 750 681
F02 1828 1778 1731 1687 1643 1597 1556 1512
F03 972 899 822 741 659 574 503 438
F04A 1401 1338 1290 1234 1179 1126 1073 1014
AM 9C80 Y/Y1 F05 1627 1574 1526 1479 1428 1370 1326 1285
0805D*
F06 1863 1810 1772 1726 1683 1638 1596 1547
F07 1920 1873 1835 1795 1751 1704 1673 1633
FOS 2026 1980 1932 1894 1852 1816 1777 1737
F09 2183 2140 2095 2057 2020 1978 1947 1917
F01 1589 1539 1498 1459 1417 1377 1334 1293
F02 2153 2119 2073 2044 2003 1971 1939 1907
F03 1034 745 642 550 462 374 329 287
F04A 1579 1525 1483 1443 1400 1358 1313 1260
AM9C80 Y/Y1 F05 1891 1843 1804 1767 1730 1698 1660 1626
1005C*
F06 1824 1784 1739 1700 1667 1624 1592 1S55
F07 1731 1677 1637 1600 1556 1518 1474 1439
F08 1944 1901 1864 1823 1786 1748 1719 1680
F09 i 2219 217S 2134 2106 2071 i 2039 2008 1982
Note:A DEFAULT SPEED
Note:A DEFAULT SPEED
8 www.amana-hac.com SS-AM9C80/AC9C80
AM9C80 HIGH STAGE COOLING AIRFLOW DATA
COOLINGHIGH STAGE
EXTERNAL STATIC PRESSURE,(INCHES WATER COLUMN)
F01 749 697 652 607 554 509 459 406
F02 1130 1090 1059 1022 991 957 926 895
F03 584 SS3 501 447 395 335 N/A N/A
F04 882 841 800 760 719 678 641 602
AM 9C80 Y2 F05^ 1158 1113 1090 1057 1024 996 964 935
0403A*
F06 925 881 840 800 760 721 681 645
F07 1270 1235 1208 1179 1147 1119 1088 1060
F08 1330 1295 1273 1251 1223 1195 1168 1142
F09 1417 1380 1359 1336 1314 1288 1261 1238
1`01 1125 1089 1052 1013 973 947 909 863
F02 1413 1386 1360 1330 1302 1270 1242 1211
F03 720 660 614 542 468 413 359 313
F04 1146 1113 1076 1039 1002 969 933 891
AM 9C80 Y2 F05^ 1370 1345 1317 1286 1260 1224 1187 1168
0603B*
F06 922 872 830 786 736 683 616 565
F07 1252 1198 1153 1110 1069 1028 990 953
F08 1289 1260 1232 1194 1161 1125 1087 1073
F09 1544 1500 1459 1419 1387 1349 1317 1286
F01 1036 985 940 895 848 799 751 705
F02 1391 1352 1314 1278 1241 1209 1175 1140
F03 710 646 580 S15 432 367 314 274
F04 1138 1091 1045 1001 959 920 876 832
AM 9C80 Y2 F05^ 1209 1166 1124 1083 1045 100S 964 923
0803B*
F06 977 931 880 836 785 734 683 626
F07 1298 12SS 1216 1178 1140 1102 1067 1028
F08 1456 1414 1376 1341 1302 1270 1238 1200
F09 1533 1488 1452 141S 1383 1350 1317 1286
1`01 1104 1056 1010 968 925 880 831 784
F02 1395 1347 1309 1270 1233 1199 1164 1125
F03 841 657 1 595 522 439 367 N/A N/A
F04 1311 1267 1226 1189 1150 1114 1072 1034
0804B* Y2 F05^ 1490 1447 1407 1373 1336 1303 1269 1237
8048
F06 1553 1510 1469 1435 1401 1368 1335 1300
F07 1776 1735 1695 1661 1628 1601 1570 1542
F08 1593 1548 1508 1474 1440 1409 1376 1343
F09 1853 1 1812 1773 1739 1 1708 1679 1650 1623
F01 1214 1158 1103 1045 989 936 883 823
F02 1518 1465 1418 1372 1328 1284 1237 1195
F03 831 750 671 588 501 405 348 300
F04 1303 1249 1191 1136 1081 1028 974 928
AM 9C80 Y2 FOS^ 1588 1539 1494 1447 1401 1358 1313 1267
0804C*
F06 1426 1375 1324 1277 1229 1177 1124 1078
F07 1785 1751 1717 1675 1639 1596 1557 1516
F08 1710 1666 1632 1595 1554 1512 1473 1431
F09 1 1845 1 1805 1 1771 11733 1695 1655 1618 1 1576
Note:^DEFAULT SPEED
SS-AM9C80/AC9C80 www.amana-hac.com 9
AM9C80 HIGH STAGE COOLING AIRFLOW DATA (CONT.)
COOLINGHIGH STAGE
EXTERN AL STATIC PRESSURE,(INCHES WATER COLUMN)
FOl 1420 1359 1301 1254 1206 1152 1100 1044
F02 1825 1769 1718 1673 1629 1584 1540 1497
F03 826 744 661 573 485 399 339 N/A
F04 1623 1567 1516 1468 1423 1374 1328 1281
AM 9C80 Y2 F05A 1697 1644 1596 1551 1505 1457 1413 1367
0805C`
F06 1741 1686 1639 1592 1550 1504 1462 1417
F07 1906 1855 1809 1763 1722 1682 1641 1597
F08 1966 1914 1869 1825 1782 1745 1703 1660
F09 2201 2152 2107 2073 2034 1996 1962 11925
FO1 1175 1109 1044 977 905 830 7S0 681
F02 1828 1778 1731 1687 1643 1597 1556 1512
F03 972 899 822 741 659 574 503 438
F04 1401 1338 1 1290 1234 1179 1126 1073 1014
AM9C80
0805D` Y2 FOSA 1627 1574 1526 1479 1428 1370 1326 1285
F06 1863 1810 1772 1726 1683 1638 1596 1547
F07 1920 1873 1835 1795 1751 1704 1673 1633
F08 2026 1980 1932 1894 1852 1816 1777 1737
F09 2183 2140 2095 2057 2020 1978 1947 1917
FO1 1589 1539 1498 1459 1417 1377 1334 1293
F02 2153 2119 2073 2044 2003 1971 1939 1907
F03 1034 745 642 550 462 374 329 287
F04 1579 1525 1483 1443 1400 1358 1313 1260
AM 9C80 Y2 FO5A 1891 1843 1804 1767 1730 1698 1660 1626
1005C'
F06 1824 1784 1739 1700 1667 1624 1592 1SS5
F07 1731 1677 1637 1600 1556 1518 1474 1439
F08 1944 1901 1864 1823 1786 1748 1719 1680
F09 2219 2175 2134 2106 2071 2039 2008 1982
Note:A DEFAULT SPEED
RECOMMENDED • . FOR
CONNECTIONOUTDOOR •.
FURNACE MODEL Y2 Yl
AM9C80080SDX F02 FO1
10 www.amana-hac.com SS-AM9C80/AC9C80
AM9C80 CIRCULATION AIRFLOW DATA
CIRCULATION AIFLOW
EXTERNAL STATIC PRESSURE,(INCHES WATER COLUMN)
FOl 749 697 652 607 554 509 459 406
F02 1130 1090 1059 1022 991 957 926 895
F03 584 553 501 447 395 335 N/A N/A
F04 882 841 800 760 719 678 641 602
AM9C80 G F05 1158 1113 1090 1057 1024 996 964 935
0403A*
F06 925 881 840 800 760 721 681 645
F07 1270 1235 1208 1179 1147 1119 1088 1060
F08 1330 1295 1273 1251 1223 1195 1168 1142
F09 1417 1380 1 1359 1336 1314 1288 1261 1238
F01 1125 1089 1052 1013 973 947 909 863
F02 1413 1386 1360 1330 1302 1270 1242 1211
F03 720 660 614 542 468 413 359 313
FO4 1146 1113 1076 1039 1002 969 933 891
AM9C80 G F05 1370 1345 1317 1286 1260 1224 1187 1168
0603B*
F06 922 872 830 786 736 683 616 565
F07 1252 1198 1153 1110 1069 1028 990 953
FOS 1289 1260 1232 1194 1161 1125 1087 1073
F09 1544 1500 1459 1419 1387 1349 1317 1286
F01 1036 985 940 895 848 799 7S1 705
F02 1391 1352 1314 1278 1241 1209 1175 1140
F03 710 646 580 515 432 367 314 274
F04 1138 1091 1045 1001 959 920 876 832
AM 9C80
0803B" G FOS 1209 1166 1124 1083 1045 1005 964 923
F06 977 931 880 836 785 734 683 626
F07 1298 1255 1216 1178 1140 1102 1067 1028
F08 1456 1414 1376 1341 1302 1270 1238 1200
F09 1533 1488 1452 1415 1383 1350 1317 1286
F01 1104 1056 1010 968 925 880 831 784
F02 1395 1347 1309 1270 1233 1199 1164 1125
F03 841 657 595 522 439 367 N/A N/A
F04 1311 1267 1226 1189 1150 1114 1072 1034
AM9C80 G F05 1490 1447 1407 1373 1336 1303 1269 1237
0804B*
F06 1553 1510 1469 1435 1401 1368 1335 1300
F07 1776 1735 1695 1661 1628 1601 1570 1542
F08 1593 1548 1508 1474 1440 1409 1376 1343
F09 1853 1812 1773 1739 1708 1679 1650 1623
FO1 1214 1158 1103 1045 989 936 883 823
F02 1518 1465 1418 1372 1328 1284 1237 1195
F03 831 750 671 588 501 405 348 300
F04 1303 1249 1191 1136 1081 1028 974 928
AM 9C80 G FOS 1588 1539 1494 1447 1401 1358 1313 1267
0804C*
F06 1426 1375 1324 1277 1229 1177 1124 1078
F07 1785 1751 1717 1675 1639 1596 1557 1516
F08 1710 1666 1632 159S 1554 1512 1473 1431
F09 1845 1805 1771 1733 1695 1655 1618 1576
Note:A DEFAULT SPEED
SS-AM9C80/AC9C80 www.amana-hac.com 11
AM9C80 CIRCULATION AIRFLOW DATA (CONT.)
CIRCULATION AIFLOW
%am man
FOl 1420 1359 1301 1254 1206 1152 1100 1044
F02 1825 1769 1718 1673 1629 1584 1540 1497
F03 826 744 661 573 485 399 339 N/A
F04 1623 1567 1516 1468 1423 1374 1328 1281
0805C'9C80 G F05 1697 1644 1596 1551 1505 1457 1413 1367
F06 1741 1686 1639 1592 1550 1504 1462 1417
F07 1906 1855 1809 1763 1722 1682 1641 1S97
F08 1966 1914 1869 1825 1782 1745 1703 1660
F09 2201 2152 2107 2073 2034 1996 1962 1925
1`01 1175 1109 1044 977 90S 830 7SO 681
F02 1828 1778 1731 1687 1643 1597 1556 1512
F03 972 899 822 741 659 574 503 438
F04 1401 1338 1290 1234 1179 1126 1073 1014
AM9C80 G F05 1627 1574 1526 1479 1428 1370 1326 1285
0805D*
F06 1863 1810 1772 1726 1683 1638 1596 1547
F07 1920 1873 1835 1795 1751 1704 1673 1633
F08 2026 1980 1932 1894 1852 1816 1777 1737
F09 2183 2140 2095 2057 2020 1978 1947 1917
FO1 1589 1539 1498 1459 1417 1377 1334 1293
F02 2153 2119 2073 2044 2003 1971 1939 1907
F03 1034 745 642 550 462 374 329 287
F04 1579 1525 1483 1443 1400 1358 1313 1260
AM9C80 G F05 1891 1843 1804 1767 1730 1698 1660 1626
1005C*
F06 1824 1784 1739 1700 1667 1624 1592 1555
F07 1731 1677 1637 1600 1556 1518 1474 1439
F08 1944 1901 1864 1823 1786 1748 1719 1680
F09 2219 2175 2134 2106 2071 2039 2008 1982
Note:A DEFAULT SPEED
Note:A DEFAULT SPEED
12 www.amana-hac.com SS-AM9C80/AC9C80
AM9C80 HEATING AIRFLOW DATA
HEATING AIFLOW
EXTERNAL STATIC PRESSURE,(INCHES WATER COLUMN)
FOl^ 749 28 697 30 652 32 607 34 554 37 509 459 406
W/W 1 F03^^ 584 N/A 553 N/A 501 N/A 447 N/A 395 N/A 335 N/A N/A
AM9C80 F04 882 24 841 25 800 26 760 27 719 29 678 641 602� 15-45
0403A F02^ 1130 26 1090 27 1059 28 1022 29 991 30 957 926 895
W2 F04 882 34 841 35 800 37 760 39 719 41 678 641 602
F05 1158 26 1113 27 1090 27 1057 28 1 1024 29 996 964 935
FO1^ 1125 28 1089 29 1052 30 1013 31 973 32 947 909 863
W/W1 F03^^ 720 N/A 660 N/A 614 N/A 542 N/A 468 N/A 413 359 313
AM9C8O F04 1146 27 1113 28 1076 29 1039 30 1002 31 969 933 891
� 15-45
0603E F02^ 1413 31 1386 32 1360 33 1330 33 1302 34 1270 1242 1211
W2 F04 1146 39 1113 40 1076 41 1039 43 1002 44 969 933 891
F05 1370 32 1345 33 1317 34 1286 35 1 1260 35 1224 1187 1168
FO1^ 1036 40 985 42 940 44 895 46 848 49 799 751 705
W/W1 F03"^ 710 N/A 646 N/A 580 N/A 515 N/A 432 N/A 367 314 274
A M9C80 F04 1138 36 1091 38 1045 40 1001 41 959 43 920 876 832
0803B` F02^ 1391 43 1352 44 1314 45 1278 46 1241 48 1209 1175 1140 30-60
W2 F04 AA 1138 N/A 1091 N/A 104S N/A 1001 N/A 959 N/A 920 876 832
FOS 1209 49 1166 51 1124 53 1083 55 1045 57 1005 964 923
FO1^ 1104 38 1056 39 1010 41 968 43 925 45 880 831 784
W/W1 F03"^ 841 N/A 657 N/A 595 N/A S22 N/A 439 N/A 367 315 N/A
AM9C80 F04 1311 32 1267 33 1226 34 1189 35 1150 36 1114 1072 1034
0804B' F02^ 1395 42 1347 44 1309 45 1270 47 1233 48 1199 1164 1125 30-60
W2 F04 1311 45 1267 47 1226 48 1189 50 1150 52 1114 1072 1034
F05 1490 40 1447 41 1407 42 1373 43 1336 44 1303 1 1269 1237
FO1^ 1214 34 1158 36 1103 38 104S 40 989 42 936 883 823
W/W1 F03^^ 831 N/A 750 N/A 671 N/A 588 N/A 501 N/A 405 348 300
AM9C80 F04 1303 32 1249 33 1191 35 1136 37 1081 38 1028 974 928
0804C. F02^ 1518 39 1465 40 1418 42 1372 43 1328 4S 1284 1237 1195 25-SS
W2 F04 1303 45 1249 1 47 1 1191 50 1136 52 1081 55 1028 1 974 928
F05 1588 37 1539 39 1494 40 1447 41 1401 42 1358 1313 1267
FO1^ 1420 29 1359 31 1301 32 1254 33 1206 34 1152 1100 1044
W/W1 F03^^ 826 N/A 744 N/A 661 N/A 573 N/A 485 N/A 399 339 N/A
AM9C80 F04^^ 1623 N/A 1567 N/A 1516 N/A 1468 N/A 1423 N/A 1374 1328 1281
0805C' F02^ 1825 1 32 1769 33 1718 34 1673 35 1629 36 1584 1540 1497 25-55
W2 F04 1623 37 1567 38 1516 39 1468 40 1423 42 1374 1328 1281
FOS 1697 1 35 1644 36 1596 37 1SS1 38 1SOS 39 1457 1 1413 1367
Note:^DEFAULTSPEED
AA NOT RECOMMENDED FOR HEATING
SS-AM9C80/AC9C80 www.amana-hac.com 13
AM9C80 HEATING AIRFLOW DATA (CONT)
HEATING •
EXTERNAL STATIC PRESSURE,(INCHES WATER COLUMN)
TEMP
RANGE
FOl^ 1175 35 1109 37 1044 40 977 42 905 46 830 750 681
W/W 1 F03^^ 972 N/A 899 N/A 822 N/A 741 N/A 659 N/A 574 503 438
A M9C80 F04 1401 30 1338 31 1290 32 1234 34 1179 35 1126 1073 1014
0805D' F02^ 1828 32 1778 33 1731 34 1687 35 1643 36 1597 1556 1512 20-50
W2 F04 1401 42 1338 44 1290 46 1234 48 1179 50 1126 1073 1014
F05 1627 36 1574 38 1526 39 1479 40 1428 41 1370 1326 1285
FO1^ 1589 33 1539 34 1498 35 1459 36 1417 37 1377 1334 1293
W/W1 F03^^ 1034 N/A 745 N/A 642 N/A 550 N/A 462 N/A 374 329 287
A M9C80 F04 1579 33 1525 34 1483 35 1443 36 1400 37 1358 1313 1260
25-
1005Cy F02^ 2153 34 2119 35 2073 36 2044 36 2003 37 1971 1939 1907 55
W2 F04 1579 47 1525 49 1483 50 1443 51 1400 53 1358 1313 1260
F05 1891 39 1843 40 1804 41 1767 42 1730 43 1 1698 1660 1626
Note:A DEFAULT SPEED
A^NOT RECOMMENDED FOR HEATING
14 www.amana-hac.com SS-AM9C80/AC9C80
WIRING DIAGRAM
9
v
r�
L TO
1GND 115 VAC/10 b0 HZ
n r POWER SUPPLY WITH
ID BLOWER TWO-STAGE PRESSURE o OVERCURRENT
HOT SWITCH ASSEMBLY Y �� L PROTECTION DEVICE
SURFACE m
IGNITER OR HIGH FIRE 0 K r POWER GMISSBEFORENNECT
PRESSURE SERVICING.WIRING
LOW FIRE C c SWITCH W N TO UNIT MUST BE
PRESSURE
SWITCH DISCONNECT PROPERLY POLARIZED
2 CIRCUIT AND GROUNDED.
CONNECTOR
OR TO 115V ER 10 RI HZ POWER SUPPLY WITH
11+ HI a PU OVERCURREN7 PROTECTION DEVICE
FERRITE WARNING: L GND i
C a Gv SENSOR DISCONNECT POWER r1
TWO STAGE
GAS VALVE LO I BR BEFORE SERVICING.
(WHITE ROIXiERS) WIRING TO UNIT
MUST BE PROPERLY
POLARIZED AND
SOME UNITS MY HAVE GROUNDED '�coNNFCT \.
t ROLL OUT SWITCH -`
P PK �/ c
CN lJ LJ L J D Gl
UTO RESET PRIMARY �.NCTION eOx 2
LIMIT CONTROL N O
—RD ry A
INDUCED INDOOR I
WH—��/^J /I1 DRAFT
RD BLOWEH
BK CmCNuWlaRt Ox Gx LY
'p1C2
aURNERCOMPARTMEN\v �\1 70 W
URCL
BLOWERCOMPARTMENT RD
m
AUTORFSFT
I IM n=TRa �7/ n {rDxER rwuiwu ' = E
v
g ELECT aROMNFn E
CIF
xE�TRAL F m Q
NOT SLmFACE y �
N NNER N U
fi f Fsl
to >
1 EIAME SFNswR O E
e A �j Its vac n O
uRSForMF `m vO
T.nl as vac 00 0
a y
m M
x y oIN
0 O C m R MANVAL SET R0.LOJT LIMB 5 p1
RD BL D ilral AUTO RESET y tl
TO I AVTORESETAUx LIMIT PRMARY LIMIT C
OR
VI "00 n
RN Z N d
an rl I I NLo II _ n
OW FI
RE
RE S SWRpR �
LO O O O WI R
Psz lvl > E
� � u
HGH nRE
II
Fa1COOFSFROM LEFT iORiGNT RE555WRCH = O
G
F 1 N
0 MVL l l01 �j
O OIU MVN HI M G_
� 4VC II
t C 2
GAS �
= VA E
W2WMJRG CYNIY2 I•i 'n'"
Rt
V VTR
HARNESS u
NAIR a
�T TG O
ryryry��� ` RK MICRO r pR�lpi GND
BK 1 p INTEGGRATED CONTROL MODULE
//17 EG S
NOTES
ru GrvO £ SET HFAT URIERs W ON ROOM ACEW STAT AT a T AMPS T Y OU
2 ;SET
SCTWERS SPECIFEO RE0.ACEMEM PMTS M1bT ff USEn N C
CHASSIS 90wEn WHEN OF ME ORIGINAL
RI 3 �_
GIRGULATOR BLOWER COwN1r1E ]m ANY 0.T1f Or111 IAIS7BE AS SUPPLIEDT.ATIR &LATERE
GROUND OOORSyrtCN MUSTBEXEPUC®nMVSTBENERALEASTNWUSFeoFFRIN a 3
IOPFNwNFx NOUCTO MPEMTURE ruiINOOF AT LEAST rpS'C USF COPPER E W
[xIpR OPFNr cONDII-SF.(r m N A
R UNrt MUST BE F9tlMAENtLY OfpMROED AND CpFgiM TO N F C
C �
Seven SOment Dl la '+TTRSOALL THE o4a E FAULTS.MOST RECENT TO LE AST RECENT U O
Status Se #3 SB N2 S N7 IONEo�T1EESSRMosiAATT lw�ursl AADRE TMµaSECONDS WIRE IN STalloer O m
c Internal Faults or IRO Loss E OLOR LADES: EQUIPMENT GND /�f
Lockout Due Io Excessive Retries Rec cle E E D K PINK FIELD GND + at3 O
Low Stage Pressure Switch Stuck Closed E E 1 R BROWN FIELD SPLICE v E
Low Sta a ressure Switch O n E E 2 H WHITE <�J- N
0 en Hi,
i h imlt SwitC EE 9 L BLUE SWITCH(TEMP.)
lame etect en no amB u e E 4 Y GRAY IGNITER wv eI 0
Open Fuse E 1 RED O
6 LYELLOW SWITCH(PRESS.) _
Low Flame S- nal E E 6 RORANGE OVERCURRENT
I nitor Bela Fault E L U PURPLE PROT.DEVICE 3 v
HI h Sta a Pre55Ure Switch Stuck Closed E 6 N GREEN JUNCTION �.
Hi h Sta a Pressure$WRCh O en E 9 K BLACK
TERMINAL O
Reversed Line Polaris or Grounding Error - E A INTERNAL TO
Internal Gas Valve Error E E b INTEGRATED CONTROL
External Gas Valve Error E E C PLUG CONNECTION
Open Rollout Switch E 1 1 {;� LOW VOLTAGE(24V) —
rNor O en E E N LOW VOLTAGE FIELD — —
InduCer ela trot E •M� Tf HI VOLTAGE(I 15V)
Twin Error E
GrDundln trot � 1 p 0140F02fiGB-A HI VOLTAGE FIELD
SS-AM9C80/AC9C80 www.amana-hac.com 23
ACCESSORIES
AFE18-60A Fossil Fuel(Dual Fuel)Kit d d V J d V J
HA-02 High-Altitude Natural Gas Kit J V d d J V d
LPLP03 Low LP Gas Pressure Switch V d V V V V d V
LPM-06 LP Conversion Kits d d V V V d d
SBT14 Downflow Sub-Base 14" V d — — — —
SBT17 Downflow Sub-Base 17.5" — — V V — —
SBT21 Downflow Sub-Base 21" — — — — d V
AFE18-60A Fossil Fuel(Dual Fuel)Kit V J d J d
HA-02 High-Altitude Natural Gas Kit V V V V d
LPLP03 Low LP Gas Pressure Switch V J V d J
LPM-06 LP Conversion Kits d J J J V V
Amana•is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company,L.P. All rights reserved.Our continuing
commitment to quality products may mean a change in specifications without notice.®2021 Goodman Company,L.P. • Houston,Texas • Printed in the USA.
24 www.amana-hac.com SS-AM9C80/AC9C80
(a C
Project Name: Andrew Laterza
Address: 8 Country Ridge Drive, Rye Brook, NY
OUTDOOR DESIGN CONDITIONS
Weather station: White Plains, Westchester Co.AP
Summer Outdoor F: Summer Indoor F: Design Grains: c� Daily Range:
Winter Outdoor F: Winter Indoor F Cooling RH: Elevation (Ft):
LOAD CALCULATION TOTALS
HVAC System: 2@ 80,000 furnaces
Heated square footage: Heating BTUH:
Cooled square footage: Cooling BTUH:
Heated volume(above grade CF): 11 CFM:
Cooled volume(above grade CF): Sensible cooling: .• ,
Exposed wall area(SF): Latent cooling:
SHR: 1
Load Calculation
Cooling
Heating
0 50,000 100,000 150,000 200,000
BTUH
Approved ACCA MJ8 Calculations
d
Calculations are based on the ACCA Manual J 8th Edition and are approved by ACCA.
All computed calculations are estimates on building use, weather data, and inputted
values such a R-Values, window types, duct loss, etc. Equipment selections should
meet both the latent and sensible gain as well as building heat loss.
HEATING AND COOLING LOADS
HEATING LOADS Heating Loads
SECTIONAREA HEATLOSSwindows
aboveGradeWalls
aboveGradeWalls 2,687.3 36,658 18.3°le
belowGradeWalls 1,004 3,261
belowGradeWalls
infiftration &'
ceilings 1,645.5 38,939
ducts 0 22.579
floors y H ,
floors 1,636.7 1,899 ceilings
infiltration 0 26,736 ducts
_...._...._..._..........
skylights 0 0
windows 576 29.065
Totals 159,137
COOLING LOADS Cooling Loads
windows aboveGradeWalls
SECTION - SENSIBLE LATENT
AEDExcursion 0 0 0 plants appliances
aboveGradeWalls 2,687.3 7,456 0 ''
occupants
appliances 0 1,200 0
belowGradeWalls 1,004 0 0 infiltration ceilings
ceilings 1,645.5 30,211 0 9 4 '
ducts 0 12,045 653 ducts
floors 1,636.7 0 0 16 7.`.
infiltration 0 2,653 4,510
occupants 0 920 800
plants 0 0 300
skylights 0 0 0
windows 576 15,191 0
Totals 69,675 6,262
FENESTRATION LOADS
AED Graph(mid-summer)
20,000 .,
2
10,000
Co
0
8 9 10 11 12 13 14 15 16 17 18 19
--- BTUH --- Average Average 1.3
This graph represents hourly aggregrate fenestration loads in mid-summer.
AED graph(fall)
20,000
2
ti 10,000
a0
0
8 9 10 11 12 13 14 15 16 17 18 19
-- BTUH — Average - Average`1.3
This graph represents hourly aggregrate fenestration loads in October.
COMPONENT LOADS
ABOVE GRADE WALLS
Map trace wall
8 inch brick, stone or concrete,Wood framing, Construction nr: 15B114Ow-x Exposure: N Heating BTUH: 332
R-11 cavity insulation, None board insulation. U Value: 0.099 Area: 57.9 Cooling BTUH: 0
Map trace wall
8 inch brick, stone or concrete,Woad framing, Construction nr: 15B114Uw-x Exposure: SE Heating BTUH: 546
R-11 cavity insulation, None board insulation. U Value: 0,099 Area: 95.1 Cooling BTUH: 0
Map trace wall
8 inch brick, stone or concrete,Wood framing, Construction nr: 15B11-0w-x Exposure: S Heating BTUH: 339
R-11 cavity insulation, None board insulation. U Value: 0.099 Area: 59.1 Cooling BTUH: 0
Map trace wall
8 inch brick, stone or concrete,Wood framing, Construction nr: 15B11-0w-x Exposure: NW Heating BTUH: 566
R-11 cavity insulation, None board insulation. U Value: 0.099 Area: 98.6 Cooling BTUH: 0
Map trace wall
Frame Wall,Wood framing, None cavity Construction nr: 12A-Ob w Exposure: N Heating BTUH: 3,195
insulation, Brick Veneer. U Value: 0,253 Area: 217.7 Cooling BTUH: 683
Map trace wall
Frame Wall,Woad framing, None cavity Construction nr. 12A-Ob w Exposure: E Heating BTUH: 5,626
insulation, Brick Veneer. U Value: 0.253 Area: 383.4 Cooling BTUH: 1,203
Map trace wall
Frame Wall,Woad framing, None cavity Construction nr: 12A-Ob w Exposure: S Heating BTUH: 3,195
insulation, Brick Veneer. U Value: 0.253 Area: 217.7 Cooling BTUH: 683
Map trace wall
Frame Wall,Wood framing, None cavity Construction nr: 12A-Ob w Exposure: NW Heating BTUH: 5,335
insulation, Brick Veneer, U Value: 0.253 Area: 363.6 Cooling BTUH: 1,141
Map trace wall
Frame Wall,Wood framing, None cavity Construction nr. 12A-Ob w Exposure: N Heating BTUH: 3,501
insulation, Brick Veneer. U Value: 0.253 Area: 238.6 Cooling BTUH: 749
Map trace wall
Frame Wall,Wood framing, None cavity Construction nr: 12A-Ob w Exposure: SE Heating BTUH: 5,404
insulation, Brick Veneer. U Value: 0.253 Area: 368.3 Cooling BTUH: 1,155
Map trace wall
Frame Wall, Wood framing, None cavity Construction nr: 12A-Ob w Exposure: S Heating BTUH: 3,441
insulation, Brick Veneer. U Value: 0.253 Area: 234.5 Cooling BTUH: 736
Map trace wall
Frame Wail,Wood framing, None cavity Construction nr: 12A-Ob w Exposure: NW Heating BTUH: 5,177
insulation, Brick Veneer. U Value: 0,253 Area: 352.8 Cooling BTUH: 1,107
BELOW GRADE WALLS
Map trace wall
8 inch brick,stone or concrete,Wood framing, Construction nr. 15B11-Ow-x Area: 185.8 Heating: 603
U Value: 0.056
R-11 cavity insulation, None board insulation.
BELOW
Map trace wall
8 inch brick, stone or concrete,Wood framing, Construction nr: 151311-Ow-x Area: 309.3 Heating: 1,005
U Value: 0.056
R-11 cavity insulation, None board insulation.
Map trace wall
8 inch brick, stone or concrete,Wood framing, Construction nr: 151311-0w-x Area: 189.2 Heating: 615
U Value: 0.056
R-11 cavity insulation, None board insulation.
Map trace wall
8 inch brick, stone or concrete,Wood framing, Construction nr: 15B11-0w-x Area: 319.7 Heating: 1,038
U Value: 0.056
R-11 cavity insulation, None board insulation.
Default small windows for wall Id 6235081 Construction nr. 1G
U Value: 0.87 Heating BTUH: 202
Window, NFRC rated, Clear glass. Area:
pasure: N SHGC: 0.67 Cooling BTUH: 0
Default small windows for wall Id 6235082 Construction nr: 1 G
U Value: 0.87 Heating BTUH: 404
Window, NFRC rated, Clear glass. Exposure; 8 SHGC: 0.67 Cooling BTUH: 0
Default small windows for wall Id 6235083 Construction nr: 1 G
U Value: 0.87 Heating BTUH: 202
Window, NFRC rated, Clear glass. E posure: 4 SHGC: 0.67 Cooling BTUH: 0
Default small windows for wall id 6235080 Construction nr: 1 G
U Value: 0.87 Heating BTUH: 404
Window, NFRC rated, Clear glass, Exposure: 8 SHGC: 0.67 Cooling BTUH: 0
Default small windows for wall Id 6235087 Construction nr: 1 G
U Value: 0.87 Heating BTUH: 606
Window, NFRC rated, Clear glass. Exposure: 1 SHGC: 0.67 Cooling BTUH: 195
Default large windows for wall id 6235087 Construction nr: 1 G U Value: 0.87 Heating BTUH: 1,817
Window, NFRC rated, Clear glass. Exposure: 3 SHGC: 0.67 Cooling BTUH: 584
Default small windows for wall Id 6235088 Construction nr: 1G
U Value: 0.87 Heating BTUH: 303
Window, NFRC rated, Clear glass. Area: re: E SHGC: 0.67 Cooling BTUH: 199
Default medium windows for wall id 6235088 Construction nr: 1G
U Value: 0.87 Heating BTUH: 2,422
Window, NFRC rated, Clear glass. Exposure: E8 SHGC: 0.67 Cooling BTUH: 1,591
Default large windows for wall id 6235088 Construction nr: 1G
U Value: 0.87 Heating BTUH: 1,817
Window, NFRC rated, Clear glass. Area: 36 Exposure: E SHGC: 0.67 Cooling BTUH: 1,193
Default small windows for wall Id 6235089 Construction nr. 1 G
U Value: 0.87 Heating BTUH: 303
Window, NFRC rated, Clear glass. Exposure: 6 SHGC: 0.67 Cooling BTUH: 195
Default medium windows for wall Id 6235089 Construction nr: 1 G
U Value: 0,87 Heating BTUH: 606
Window, NFRC rated, Clear glass. Exposure: 1 SHGC: 0.67 Cooling BTUH: 391
Default large windows for wall id 6235089 Construction nr: 1 G
U Value: 0.87 Heating BTUH: 1,817
Window, NFRC rated, Clear glass. Exposure: 36 SHGC: 0.67 Cooling BTUH: 1,172
Default small windows for wall id 6235086 Construction nr: 1 G
U Value: 0.87 Heating BTUH: 606
Window, NFRC rated, Clear glass. Exposure: 12 SHGC: 0.67 Cooling BTUH: 294
Default medium windows for wall id 6235086 Construction nr: 1G
U Value: 0.87 Heating BTUH: 1,817
Window, NFRC rated, Clear glass. Exposure: 36 SHGC: 0.67 Cooling BTUH: 883
Default large windows for wall id 6235086 Construction nr: 1 G U Value: 0.87 Heating BTUH: 1,817
Window, NFRC rated, Clear glass. Exposure: 36 SHGC: 0,67 Cooling BTUH: 883
Default small windows for wall Id 6235091 Construction nr: 1 G
A-,,,,, c U Value: 0,87 Heating BTUH: 303
WINDOWS7.
Default medium windows for wall id 6235091 Construction nr: 1G
U Value: 0.87 Heating BTUH: 606
Window, NFRC rated, C lear glass. Exposure: N SHGC: 0,67 Cooling BTUH: 195
Default large windows for wall id 6235091 Construction nr: 1G
Area: 36 U Value: 0.87 Heating BTUH: 1,817
Window, NFRC rated, Clear glass. Exposure: N SHGC: 0.67 Cooling BTUH: 584
Default small windows for wall id 6235092 Construction nr: 1G
Window, NFRC rated, Clear glass.
Area: 12 U Value: 0.87 Heating BTUH: 606
Exposure: SE SHGC: 0.67 Cooling BTUH: 413
Default medium windows for wall id 6235092 Construction nr: 1G
Area: � U Value: 0.87 Heating BTUH: 1,$17
Window, NFRC rated, Clear glass. Exposure: SE SHGC: 0.67 Cooling BTUH: 1,278
Default large windows for wall id 6235092 Construction nr: 1G
U Value: 0.87 Heating BTUH: 1,817
Window, NFRC rated, Clear glass. Exposure: SE SHGC: 0.67 Cooling BTUH: 1,292
Default small windows for wall id 6235093 Construction nr: 1G
U Value: 0.87 Heating BTUH: 303
Window, NFRC rated,Clear glass. Exposure: S SHGC: 0.67 Cooling BTUH: 189
Default medium windows for wall id 6235093 Construction nr: 1 G
U Value: 0.87 Heating BTUH: 606
Window, NFRC rated, Clear glass. E posure: 1 SHGC: 0.67 Cooling BTUH: 385
Default large windows for wall id 6235093 Construction nr: 1G
U Value: 0.87 Heating BTUH: 1,$17
Window, NFRC rated, Clear glass. Exposure: 3 SHGC: 0.67 Cooling BTUH: 1,160
Default small windows for wall id 6235090 Construction nr: 1G
U Value: 0.87 Heating BTUH: 606
Window, NFRC rated, Clear glass. Exposure: 12 SHGC: 0.67 Cooling BTUH: 283
Default medium windows for wall Id 6235090 Construction nr: 1 G
U Value: 0.87 Heating BTUH: 1,817
Window, NFRC rated, Clear glass. Exposure: NW SHGC: 0.67 Cooling BTUH: 865
Default large windows for wall id 6235090 Construction nr: 113
U Value: 0.87 Heating BTUH: 1,817
Window, NFRC rated, Clear glass. Exposure: N y SHGC: 0.67 Cooling BTUH: 871
Window cooling BTUHs shown here are daily average values. See AED graphs for details of fenestration loads during the day.
CEILINGS
Map trace generated ceiling
Ceiling under attic or attic knee wall,Asphalt Construction nr: 1613-0 ad Are : 57 Heating BTUH: 1,351
shingles, Dark, None.
U Value: 0.408 a .1 Cooling BTUH: 1,048
Map trace generated ceiling
Ceiling under attic or attic knee wall,Asphalt Construction nr: 16B-0 ad Area: 1,588.4 Heating BTUH: 37,588
shingles, Dark, None. U Value: 0.408 Cooling BTUH: 29,163
SKYLIGHTS i
There are no components for this section.
Skylight cooling BTUHs shown here are daily average values. See AED graphs for details of fenestration loads during the day.
There are no components for this section.
Map trace generated floor
Construction nr: 21A Heating U Value:0.02 Heating BTUH: 1,899
Basement floor, no floor insulation. Area: 1,636.7 Cooling U Value:0 Cooling BTUH: 0
F Value: N/A
HOT WATER PIPING
There are no components for this section.
System generated ducts(above conditioned space) EHLF: 0.165 Heating BTUH: 22,579
Attic-Radial ESGF: 0.209 Sensible BTUH: 12,045
ELG: 653 Latent BTUH: 653
INFILTRATION
NCFM Heating: 424 Heating BTUH: 26,736
Leakage Category: Loose NCFM Cooling: 203 Sensible BTUH: 2,653
Latent BTUH: 4,510
BLOWER • ••
There are no components for this section.
HUMIDIFICATIONWINTER
There are no components for this section.
OCCUPANTS
Nr.Occupants: 4 Sensible BTUH: 920 Latent BTUH: 600
APPLIANCES
Small kitchen: 1,200 BTUH Quantity: Sensible BTUH: 1,200
Latent BTUH:
Plant Size: small Quantity: 5 Latent BTUH: 50
Plant Size: medium Quantity: 5 Latent BTUH: 100
Plant Size: large Quantity: 5 Latent BTUH: 150
46
ROOM DETAIL
Room name: basement
Heated square footage: Total Cooling BTUH:
Cooled square footage: Total Heating BTUH:
Heated volume(above grade CF): CFM:
Cooled volume(above grade CF):
Exposed wall area(SF):
Load Calculation
Cooling
Heating
0 5,000 10,000 15,000
BTUH
AED Graph(mid-summer)
1
2
0 —
m
-1
8 9 10 11 12 13 14 15 16 17 18 19
-- BTUH --qe Average Average" 1.3
AED graph(fall)
1
0 _
m
-1
8 9 10 11 12 13 14 15 16 17 18 19
— BTUH — Average 11 1 Average* 1.3
ROOM DETAIL
Room name: 1 st floor
Heated square footage: NK&N Total Cooling BTUH: Rom
Cooled square footage: Total Heating BTUH: LUM
Heated volume(above grade CF): ® CFM: OEM
Cooled volume(above grade CF):
Exposed wall area(SF):
Load Calculation
Cooling
Heating
0 20,000 40,000 60,000
BTUH
AED Graph(mid-summer)
10,000 - gin
ti 5,000
m
0
8 9 10 11 12 13 14 15 16 17 18 19
--- BTUH — Average -- Average' 1.3
AED graph(fall)
7,500
= 5,000
m
2,500
0
8 9 10 11 12 13 14 15 16 17 18 19
— BTUH — Average 11 Average 1.3
ROOM DETAIL
Room name:2 nd floor
Heated square footage: SEEM Total Cooling BTUH:
Cooled square footage: 10MAI Total Heating BTUH:
Heated volume(above grade CF): 10,1M CFM:
Cooled volume(above grade CF):
Exposed wall area(SF): NUMMI
Load Calculation
Cooling
Heating
0 20,000 40,000 60,000 80,000 100,000
BTUH
AED Graph(mid-summer)
10,000
5,000
m
0
8 9 10 11 12 13 14 15 16 17 18 19
— BTUH — Average Average* 1.3
AED graph(fall)
10,000
2
5,000
m
0
8 9 10 11 12 13 14 15 16 17 18 19
--- BTUH — Average Average*1.3
1 �..: ;£l�A'' .;111' f�,l,N:''•-:\; ,t A�1� �{' ' :N 1 , '! L
.1 �,",r �1��� '+ ,•, '�u` `� � r0i`i'7ii )yt �• v .5�•,: F y a'.'' •f. fii..
.:i:✓c„ii^i•,{A i ti..... rs ?n: .0,G nl!'~ \�. �' .t•t` A r :i.%' r..;t� < 3 f�i y���Lk..Yv ,. •,f..:J• (�4
J:?`.•� �;� ��Q.i;�:t� `Y':�.:� F::L�'... �.il� a.:}=;: � r;d., ..C.;-a,. c�,r r{.. �'.:=:'o �.f•:��14i9{.� �ia:�. fir"..v'Nirv?-+„�:t: '>�7
rJ .i;y. i 1 +.>\p,�,.'.:. "� ,.�:,•:1:, T,...�� '.,r._ t fl �+, R"• -;Y ��•� r7••'4a:�] i�. .•.
C�% y °' Ra."'r � 'L.W q< �1��9 hl ''� v~ b i yj' .1( i1{� }t' ri'•'' ?1'a
^"\��y 3 •y�1' l G- j . \;�10;
VfL� rea-, b..4 a IJ•�'t� .r4 "' '.:.,.;ter..:
tgo`�.4 ♦� � f'�4� fiu r A!� •♦ 6 s ��`;
'�'•',r^.� � r d°� 19����i4.) �f 4/�./�� Y�q� �- �1 19 rr)P i +,k,. V \
wa , � ri.�;4a4i rt+%.r�..' • ,,;. �4 �:�3�+y.s`:•.;a,;e„rr109t >;�.t;F. .>' h !"it :..j 5s:.+`ill r3�.��1 �41/1i�I{��{� �.���{k/ 11�+�, t..;��.
t:..,,.pall
lv)
SI61 {7
O
' a
r O o t2Q1o4A
` ' :r ({��(6•'`.'^.« ti ,.� U O 'L7 i ..+r'`+? •♦1.
a I " D•
LU y
n:rlt3t. Z LnIL
CD
Mp
.:tit:ti'v,�••4 i CI"t �'�,{ Ur � '� N � d( -.,`gg _,':'j4ri�;,�rr�3'
D r N o `
fly" N 2
oj
m
�.
Coco Cd
': Yea
(ar ivSD t a o 40 Z � i wo4�
o
V
hrnDAQ I n j C.9
c'
• � r -,�;-- ."��•'- rr.tr. 'm +• _fiMki
—
�•
><:':� .,-f:':>� .:c.7:r •� :t:� -uL-.y:: �'a�J�, �'..t.;• �, ..1',•/�. -v',-�' •-r -a 1 {ni✓"� ��'rr ,::%% 'r• S !j =c s';t,,-,+s t •r• v. �',.� .
tr''M'\lii:. ohs. y�i{tt+;s%���,3•.• \ Ki iiyr; ,�a 1t1, \r `�%a7.2:i !, v+, ,:J`.;,: ,��"'�'•M o7:c,.,,. br r:7�
�.•-�r., > t-.. �� !� Y �i, � r-t•'r gyp,i � 1{}�� \4
y lye .d.url' -G��ft IA,V'y`� ,�.•, "'�. \::�.'i� „i , +5 �,77 7} r '?�. yb 7i.�,-•
rfi��l�cS, f�� � Jq �••�. ��i'.�. ..`s"-rilyr• `y��' t rfi�F�� 0'r�i• �•eYv<�,,,,�,e?.t ro\ � .....���•.R�i,,;Iic�,..
�� � :�/—' ����.. i•��_1'••�•�_�...%'••� `''`._�—�..'��\ ice^ � <Y' / . d�
AC" DATE(MM/DD/YYYY)
1%. , CERTIFICATE OF LIABILITY INSURANCE 11/01/2023
THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE
DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW.THIS CERTIFICATE OF
INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE
CERTIFICATE HOLDER.
IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed. If
SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this
certificate does not confer rights to the certificate holder in lieu of such endorsement(s).
PRODUCER NAME CT CLIENT CONTACT CENTER
FEDERATED MUTUAL INSURANCE COMPANY -
HOME OFFICE: P.O.BOX 328 A/C,No,Ext):888-333-4949 jla,c,No):507-446-4664
OWATONNA, MN 55060 AIL
ADDRESS:CLIENTCONTACTCENTER FEDINS.COM
INSURERS AFFORDING COVERAGE NAIC#
INSURER A:FEDERATED MUTUAL INSURANCE COMPANY 13935
INSURED 287-972-4 INSURER B:
BRUNI AND CAMPISI PLUMBING AND HEATING, INC. INSURER C:
100 GRASSLANDS RD
ELMSFORD,NY 10523-1110 INSURER D:
INSURER E:
INSURER F:
COVERAGES CERTIFICATE NUMBER:37 REVISION NUMBER:0
THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED.
NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE
ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF
SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS.
INSR TYPE OF INSURANCE ADDL SUER POLICY NUMBER POLICY EFF POLICY EXP LIMITS
X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $1,000,000
CLAIMS-MADE ❑X OCCUR DAMAGE TO RENTED PREMISES $100,000
MED EXP(Any one person) $5,000
A Y N 6119957 01/01/2024 01/01/2025 PERSONAL&ADV INJURY $1,000,000
MoAGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE 00O 000
OLICYSECT ❑LOC PRODUCTS B COMPIOP AGG $2,000,000
THER:
AUTOMOBILE LIABILITY COMBINEBINEnD SINGLE LIMIT
Ea $1,000,000
X ANY AUTO BODILY INJURY(Per Person)
A OWNED AUTOS ONLY AUTESULED N N 6119957 01/01/2024 01/01/202$ BODILY INJURY(Per Accident)
HIRED AUTOS ONLY NON-OWNED
AUTOS PROPERTY DAMAGE
ONLYPar
X UMBRELLA LIAB ICLAIMS-MADE
OCCUR EACH OCCURRENCE $5,000,000
A EXCESSLIAB N N 6119958 01/01/2024 01/01/2025 AGGREGATE $5,000,000
DED I X IRETENTICN$10,000
WORKERS COMPENSATION
AND EMPLOYERS'LIABILITY YIN PER STATUTE THER
ANY PROPRIETORIPARTNERI EXECUTIVE E.L EACH ACCIDENT
OFFICERIMEMBER EXCLUDED? N/A
(Mandatory in NH)It yes,describe under E.L DISEASE CA EMPLOYEE
DESCRIPTION OF OPERATIONS below E.L DISEASE•POLICY LIMIT
DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached if more space is required)
THE CERTIFICATE HOLDER IS AN ADDITIONAL INSURED SUBJECT TO THE CONDITIONS OF THE ADDITIONAL INSURED - OWNERS, LESSEES OR
CONTRACTORS - AUTOMATIC STATUS WHEN REQUIRED IN CONSTRUCTION AGREEMENT WITH YOU ENDORSEMENT FOR GENERAL LIABILITY.
CERTIFICATE HOLDER CANCELLATION
287-972-4
VILLAGE OF RYEBROOK 37 0 SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED
938 KING ST BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN
RYE BROOK, NY 10573-1226 ACCORDANCE WITH THE POLICY PROVISIONS.
AUTHORIZED REPRESENTATIVE
O 1988-2015 ACORD CORPORATION.All rights reserved.
ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD
DocuSign Envelope ID: BD8FC9E8-8002-4969-9451-8A6A276DBD51
YOW Workers' CERTIFICATE OF
STATE Compensation NYS WORKERS' COMPENSATION INSURANCE COVERAGE
Board
1 a. Legal Name&Address of Insured(use street address only) 1 b. Business Telephone Number of Insured
BRUNI AND CAMPISI PLUMBING AND HEATING,
100 GRASSLANDS RD 1 c. NYS Unemployment Insurance Employer Registration Number of
ELMSFORD, NY 10523-1110 Insured
Work Location of Insured(Only required if coverage is specifically limited to 1d. Federal Employer Identification Number of Insured or Social Security
certain locations in New York State, i.e., a Wrap-Up Policy) Number
13-2999646
2. Name and Address of Entity Requesting Proof of Coverage 3a. Name of Insurance Carrier
(Entity Being Listed as the Certificate Holder) Indemnity Insurance Co.of North America
VILLAGE OF RYE BROOK 3b. Policy Number of Entity Listed in Box"1a"
938 KING STREET C5595771A
RYE BROOK,NY 10573
3c. Policy effective period
10/01/2023 to 10/01/2024
3d.The Proprietor,Partners or Executive Officers are
❑X included.(Only check box if all partners/officers included)
❑ all excluded or certain partners/officers excluded.
This certifies that the insurance carrier indicated above in box '3"insures the business referenced above in box"l a"for workers'
compensation under the New York State Workers'Compensation Law. (To use this form, New York(NY)must be listed under Item 3A
on the INFORMATION PAGE of the workers'compensation insurance policy).The Insurance Carrier or its licensed agent will send
this Certificate of Insurance to the entity listed above as the certificate holder in box"2"
The insurance carrier must notify the above certificate holder and the Workers' Compensation Board within 10 days IF a policy is canceled
due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or
eliminate the insured from the coverage indicated on this Certificate. (These notices may be sent by regular mail.) Otherwise,this
Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent,or until the policy
expiration date listed in box"3c",whichever is earlier.
This certificate is issued as a matter of information only and confers no rights upon the certificate holder. This certificate does not amend,
extend or alter the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond those contained in the
referenced policy.
This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect.
Please Note: Upon cancellation of the workers'compensation policy indicated on this form, if the business continues to be
named on a permit, license or contract issued by a certificate holder,the business must provide that certificate holder with a
new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the
mandatory coverage requirements of the New York State Workers' Compensation Law.
Under penalty of perjury, I certify that I am an authorized representative or licensed agent of the insurance carrier referenced
above and that the named insured has the coverage as depicted on this form.
Approved by: Lex Smith
oocu10ryV4 h»me of authorized representative or licensed agent of insurance carrier)
Approved by: '�° 9/8/2023
(Signature) (Date)
Title: Assistant Program Manager
Telephone Number of authorized representative or licensed agent of insurance carrier. 214-721-6248
Please Note: Only insurance carriers and their licensed agents are authorized to issue Form C-105.2. Insurance brokers are NOT
authorized to issue it.
C-105.2 (9-17) www.wcb.ny.gov
Acct# 2809046