Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
MP23-131
QyE BR � 19 t VILLAGE OF RYE BROOK MAYOR 938 King Street, Rye Brook,N.Y. 10573 ADMINISTRATOR Jason A. Klein (914) 939-0668 Christopher J. Bradbury www.ryebrook.org TRUSTEES BUILDING& FIRE INSPECTOR Susan R. Epstein Steven E. Fews Stephanie J. Fischer David M. Heiser Salvatore W. Morlino CERTIFICATE OF COMPLIANCE October 11,2023 Garfield Maitland&Jill Maitland 10 Old Orchard Road Rye Brook,New York 10573 Re: 10 Old Orchard Road,Rye Brook,New York 10573 Parcel ID#: 135.26-1-59 This document certifies that the work done under Mechanical Permit #23-131 issued on 8/29/2023 for the installation of a new heat pump and ductless unit,and to legalize condenser,air handler and ductwork has been satisfactorily completed. Sincerely, *; 4 1 Steven E. Fews Building&Fire Inspector /to E BRC�k. 1982 BUILDING DEPARTMENT ❑"BUILDING INSPECTOR ❑ASSISTANT BUILDING INSPECTOR VILLAGE OF RYE BROOK r ❑CODE ENFORCEMENT OFFICER 938 King Street• Rye Brook,NY 10573 r" (914) 939-0668 FAx (914) 939-5801 www ryebrook.org ,3 - - - - - - - - - - - - - - - - - - - - INSPECTION REPORT - - - - - - - - - - - - - - - - - - - - ADDRESS: C \ 6 �.-� �'�. DATE: PERMIT# l `� l ISSUED: ��,-W-IISECT: 1 �" BLOCK: ' LOT: LOCATION: �' J`T` ' ' / OCCUPANCY: j11 y� ❑ Violation Noted ( THE WORK IS... [J PASSED ❑ FAILED REINSPECTION ❑ SITE INSPECTION REQUIRED ❑ FOOTING ❑ FOOTING DRAINAGE ❑ FOUNDATION ❑ UNDERGROUND PLUMBING NOTES ON INSPECTION: ❑ ROUGH PLUMBING ❑ ROUGH FRAMING ; ❑ INSULATION ❑ Natural Gas ❑ L.P. Gas ❑ FUEL TANK ❑ FIRE SPRINKLER ❑ FINAL PLUMBING ❑ CROSS CONNECTION FINAL ❑ OTHER _ _ : W C O O W •� h \ \ u14 A. a a o W 3 Q F-� • Ln W a �, c Gr1 au W _ Z ►n z v .xc Z O al o 0 14) Z ca o 8 o ; w °apk►—� a A N " '-�' ' u a b Q oen 0 :� I--i Q oo Cn z ... w v S - o Ono C7 � Q H oo - vU a o z H z u z ;> o � vCN W o � 8 � - gip F v a " W zga,� � O u V� 1- .a R,� .. Q wio !d od .� H � � 9 4 4141414;41 4 4141-0 6 4 49 9 414 414141414141414 4 41414 4 4 44444141414141441.14 BUILD ( &A-R 'MENT Q VIL , E OF RY9,� OOK AUG 2 8 2023 938 KING ET RYE;BR ,NY 10573 VILLAGE OF RYE BROOK d BUILDING DEPARTMENT APPLICATION FOR PERMIT TO INSTALL AND/OR REMOVE HEATING VENTILATION AND/OR AIR CONDITIONING E UIPM/ENTj FOR OFFICE USE QN1, * PERMIT#: M �3 Approval Date: _ Permit Fee:$ Approval Signature: Other: Disapproved: (fees are non-refundable) REQUIREMENTS FOR RELEASE OF PERMIT&CERTIFICATE OF COMPLIANCE: I, Properly completed& Signed Application, 2. Site/Staging Plan if Required by the Building Inspector. 3. Copy of Licensed Contractor's Liability Insurance. (Village of Rye Brook must be listed as certificate holder)&Workers Compensation Insurance on a NYS Board form(Form q C105.2 or Form#U26.3'or NY State Workers Compensation Waiver) 4. Payment of Fees/Unit: RESIDENTIAL =$100.00/unit•COMMERCIAL= $350.00/unit. 5. Complete specifications for each unit being installed. 6. Inspection by the Building Department for removal and/or installation,(48 hour notice required) 7. Electrical work requires a separate Flectrical Permit&Electrical Inspection. 8. Plumbing/Gas work requires a separate Plumbing Permit&Plumbing Inspection. Application dated, p,):;9—t=) is hereby made to the Building Inspector of the Village of Rye Brook for a permit for the installation and or removal of the HVAC equipment as listed below.The applicant and property owner,by signing this document agrees that said equipment will be installed and/or removed in conformance with all applicable Local,County,State& Federal laws, codes,rules and regulations. I. Address: 10 Old Orchard Road SBL:/3.5-i YO—/— Zone: 2. Property Owner: Garfield Maitland Address: 10 Old Orchard Road Phone#: 917-535-7321 Cell#: 917-535-7321 email: mrgeeman@optonline.net 3. Contractor: Arctic Mechanical/Jhc Bravo Address:460 North Main Street,Port Chester,NY 10573 Phone#: 914-830-938 Cell#: 914-830-938 email: bravojr@arctic-mechanical.com 4. Scope of Work:New Installation( )•Replacement( )•Removal( )•Other*: New Installation and legalization 5. List Equipment: Install Mitsubishi m#MUZ-WR18NA- 1 heit temp and Mitsubishi m#MSZ-WR18N_A-U1 fan coil for Sunroom. Legalize existing ductwork for home. Guardian m#GCGD42S21 S2C condenser and Guardian m#RFCX42CP14MP21A air handler located in attic. 6. Localion rat'Equipmenl: Mitsubishi m#MUZ-WRI8NA-U1 heat pump and Guardian m#GCG©42S21 S2C condeoser on left side of house. Mitsubishi m#MSZ-WR18NA-U1 fan coil for Sunroom. Guardian m#RFCX42CP14MP21A air handler located in attic. 7. Method of Installation/Removal(list all equipment needed to perform job): t 3l32023 STATE OF NEW YORK,COUNTY OF WESTCHESTER ) as: Jhonny Bravo ,being duly sworn,deposes and states that he/she is the applicant above named, (print name of individual signing as the applicant) and further states that(s)he is the Heating,Ventilation and/or Air Conditioning Contractor for the legal owner and is duly authorized to make and file this application. That all statements contained herein are true to the best of his/her knowledge and belief,and that any work performed,or use conducted at the above captioned property will be in conformance with the details as set forth and contained in this application and in any accompanying approved plans and specifications,as well as in accordance with the New York State Uniform Fire Prevention& Building Code,the Code of the Village of Rye Brook and all other applicable laws,ordinances hand regulations. Sworn to before me this o�Q Sworn to fore me this d day of ,20� day of �)�5) ,243 )- 447 igof Property Owner Signature of Applicant Chi etJ Jhonny Bravo Print Name of Ppperty-Owner Print Name o Applicant Notary Publ Notary Public STEPHANIE VARGA NOTARY PUBLIC,STATE OF NEW YORK MAURICIO REDONDO -state of Registration No. 01 VA0002757 Notary No 1ic 01 RE640542 New York Qualified in Westchester County Qualified in westches!ar County Commiccinn Expires 03/13/2027 My Commission Expires Mar 4,2024 This application must be properly completed in its entirety and must include the notarized signature(s)of the legal owner(s)of the subject property, and the applicant of record in the spaces provided. Any application not properly completed in its entirety and/or not properly signed shall be deemed null and void and will be returned to the applicant. 2 313/2023 i M O O W i N � W x H v a K r � W Ln °; n a :c7 c z z x � x N � en M Q a o Q F e Q w o � H a N M i O Q enLn co a C41, a ; cam�o ON OS Lt, Z w v U z ' w F � M , ,� z w � �, z rr rr�� O u WO 11 os • O u. cs: U a d z FO W v, w F' taa w O Z a , Ln U s O o w z u � x w -- � lCj to �Q3 4 4 4i M i,C 4;tC;4i(i4iA»474t. t�����j �i� �i���Ti��� D E- C� � 'Y/I -,� aye- aR��� jD BUILP1NG ISE�VR MENT VILPE OF RYE OK �SEP 2 0 2023 938 KIN"�REET RYE B ,NY 10573 VILLAGE--- OF RYE BROOK BUILDING DEPARTMENT .or ELECTRICAL PERMIT APPLICATION Westchester County Master Electricians License Required FOR OFFICE USE ONLY -f��3—I3 EP#: Approval Date: SEP Permit Fee: $ CD Approval Signature: Other: Application dated, g—c-;>0'_d3 is hereby made to the Building Inspector of the Village of Rye Brook NY, for the issuance of a Permit to install and/or remove electrical equipment,wiring, fixtures, or to perform other high or low voltage electrical work as per the detailed statement described below. By signing this document, the applicant & property owner agree that all electrical work performed will be in conformance with all applicable Federal,State,County and Local Codes. 1.Address:I7 NA Y[�/l�l)/a hpac!I SBL:1&G.Zro Zone:�C-/5 2.Property Owner: 6ayR_, 16 on4,T kk "A'4j&j A Address: Phone#: Cell#: email:3.Master Electrician/Licensed Installer: Address: (Dc1 4laoho, A-\Atnuc 'n�t� Lic.#: 55 Phone#: q[c�, 3 �3 4, #: IR 14 Sim email: Me(.CrQ td. � `L ®QO�.C�Y" Company Name: V)V- ,:p� ��'Y1[. RsAr Address: lQrl ��)' J ?e-- l� 4.Proposed Electrical Work/Fixture Count:_ rr�-yy� Sj _U \L, fdS L �C jJkcT S �J 5.3`d Party Electrical Inspection Agency: w i of STATE OF nNEW YORK,COUNTY OF WESTCHESTER ) as: hi�� 1 L*� ,being duly sworn,deposes and states that he/she is the applicant above named,and does further (print name of in ual si Wing as the applicant) ` state that(s)he is the�i`,�1 _�Z�dn for the legal owner and is duly authorized to make and file this application. (Master Electrician/Licensed Installer) The undersigned further states that all statements contained herein are true to the best of his/her knowledge and belief,and that any work performed,or use conducted at the above captioned property will be in conformance with the details as set forth and contained in this application and in any accompanying approved plans and specifications,as well as in accordance with the New York State Uniform Fire Prevention&Building Code,the Code of the Village of Rye Brook and all other applicable laws,ordinances,and regulations. Sworn to before me t is Sworn to before me this X f 114 3 day of fh 0 2 3 Sign e o P operty Ow er ignature of Applicant Natfira44d Na=krp Print Name of Prope y Owner ',-ffffiFNqme of pp ica Nota o DARLING ALDANA DAR G ALDANA Notary Public-State of New York Notary Pu c-State of New York No.01AL6425946 No.01AL6425946 Qualified in Westchester County Qualified in Westchester County hty commission Expires sty Commission Expires 11IM02`� 3/2023 STATE WIDE INSPECTION SERVICES, INC.!, CAO Service With lntegri�v •:0 • • SWIS • : APPLICATION tel 845.202.7224 •. • Office Use Elect.Permit# P�3 - Q J Date X-- J \ Sci Ft d Plumbing Permit# Final Certificate# City/Village Zip j 1 Building Dept. County Address - tc— ross Street Section Block Lot Owner Name/Address(If different than above) Contact Number ❑Basement ❑1st FI. ❑2nd FI. ❑3rd FI. ❑More Than 3 FI. ❑Garage ❑Attic ❑Outside Residential ❑Commercial Receptacles Special Recept GFCI AFCI Switches Dimmers Smoke Alarms C/0 Detector Hood Trash Compact Amt Amps Range(s) Cooktop(s) Oven(s) Dishwashers Refrigerator Disposal Microwave Luminaires Generator Transfer Switch SERVICE Amperage #Panels 1P 3P #Meters #Disconnect ❑Underground ❑New ❑ Reconnect ❑Repair ❑Overhead ❑Upgrade ❑ Disconnect Utility ID# ❑Con Ed ❑ NYSEG ❑Central Hudson ❑ Orange/Rockland PHOTOVOLTAIC SYSTEM PV Modules Inverters AC Disconnect Junction Box Combiner Box Load Center PV Monitor Energy Storage System DC Disconnect ❑Legalization ❑ Safety Inspection ❑Consultation i J SEP 2 0 2023 VILLAGE OF RYE BROOK BUILDING DEPARTMENT This application is valid for one(1)year from the date received by SWIS.This application is intended to cover the above listed items to be inspected,if at anytime of inspection additional items have been installed,you are authorized to make the inspection and adjust the fee for the additional items inspected.The applicant declares that there is no open applications for the above address with any other inspection company.The applicant, owner or authorized agent agrees to all the above terms and conditions asset forth for the application. Email Address �� { F-�L_ ,�_ _ I 1 Name / I i L oI - License# — Date �. j Signature _ Address I City/State i� I Zip Code Company s Ph ne# D FC MWF DD State Wide Inspection Services SEP 2 8 2023 1080 Main Street Fishkill, NY 12524 845 202 7224 Phone VILLAGE OF RYE BROOK 914-219-1062 Fax STATE WIDE INSPECTION SERVICES BUILDING DEPARTMENT Email: office@swisny.com Service With integrity Website: www.swisny.com BY THIS CERTIFICATE OF COMPLIANCE STATE WIDE INSPECTION SERVICES CERTIFIES THAT: Upon the application of: Upon Premises Owned by: Mecca Electric of Rye, Inc. Garfield&Jill Maitland Anthony Nostro 10 Old Orchard Road 109 Maple Avenue Rye Brook, NY 10573 Rye, NY 10580 Located at: 10 Old Orchard Road, Rye Brook, NY 10573 Section: Block: Lot: Electrical Permit Number: EP23-205 135.26 1 59 Certificate Number: 2023-7034 Building Permit Number: MP23-131 A visual inspection of the electrical system was conducted at the Residential occupancy described below.The electrical system consisting of electrical devices and wiring is located in/on the premises at: 10 Old Orchard Road, Rye Brook, NY 10573 The Sunroom,Attic, and Exterior were inspected in accordance with the NYS and NFPA 70-2017 and the detail of the installation, as set forth below,was found to be in compliance on the 27th day of September 2023. Name Quantity Rating Circuit Type HVAC Systems 02 officer: Frank J. Farina This certificate may not be altered in any way and is validated only by the presence of a seal at the location indicated.This certificate is valid for work performed on the date of inspection only. i I i I I of 3 I "t A t 33.5a' N 1744'19" , J ) Lit a " AREA. M,tg�h,5ti: N U r�- newt P�.Mr I�, M fer �vnroDf►� Mini SFi,tLot 9 Mat P��aU' f�lr � / flog Patlo I tC_ 7WrCJl .. t twy F "S ro .tkny v vn�er lot'o°c No /0 '�601f252—W D fJ 1 3' g tl�/Jl Lot 7 >r Air • qovj 860h haute, S \ � W N O O � N o t0 0 g 0 4II 1 �-- R-629.9r' L-107.98' �1 - - V i FILE COPY OLD ORCHARD ROAD N --1- I Ricn� �® ' gyp`NE(✓y . Spinelli c",PAP O A SPA�P� Survey of Lot 8, Section E_, as shown 650 Halstead Avenue on "Map of Lots A & B, Rye Acres, Mamaroneck, N. Y. 10543 * ay `' * the Property of the Rye Acres (914) 381-2357 j Company" in the Town of Rye, Village N.Y.S. Lic. Land Surveyor / of Rye Brook, Westchester County, NY. No. 49240 �� 49240 Filed April 26. 1950 as Map No. 7050. —Unauthorized additions to or alterations of this LA�� � t plan is a violation of Section 7209 of the N.Y.S. Scale 1"=20' Juiy 14, 2021 Education Law. E/ "RYEACRES" C C Project Name: 10 Old Orchard Road Address: 10 Old Orchard Road,Rye Brook,NY OUTDOOR DESIGN CONDITIONS Weather station White Plairs,Westchester Co.AP Summer Outdoor F: 11� Summer Indoor F: Design Grains: ® Daily Range: F Winter Outdoor F: JJJM Winter Indoor F: Cooling RH: ®i Elevation(Ft): LOAD CALCULATION TOTALS HVAC System: 10 Old Orchard Road Heated square footage: NOR-Tom Heating BTUH: ETIXM Cooled square footage: ®s e Coding BTUH: Heated volume(above grade CF): CFM: Cooled volume(above grade CF): Sensible cooling Exposed wall area(SF): Latent cooling: Elm SHR: Load Calculation Coobng Heating 20.000 40,000 60,000 80,000 100,000 BTUH Approved ACCA MJ8 Calculations Calculations are based on the ACCA Manual J 8th Edition and are approved by ACCA. All computed calculations are estimates on building use, weather data, and inputted values such a R-Values, window types, duct loss, etc. Equipment selections should meet both the latent and sensible gain as well as building heat loss. HEATING AND COOLING LOADS HEATING LOADS Heating Loads aboveGradeWalls aboveGradeWalls 2,389.3 13,442 windows ceilings 3,073.8 6,775 ceilings ducts 0 10,235 ducts Doors 2,003.1 13,296 11 infiltration 0 18,537 nfillration floors skylights 0 0 *tip windows 564 28,459 Totals 90,744 COOLING LOADS Cooling Loads I aboveGradeWalls SECTION AEL)Eacurslon 0 0 0 windows appliances aboveGradeWalls 2,389.3 6,744 0 appliances 0 3,400 0 ceilings ceilings 3,073.8 6,424 0 occupants ducts ducts 0 7,845 433 floors 2.003.1 4,432 0 infiltration floors infiltration 0 3,307 3,066 occupants 0 1,150 1.000 plants 0 0 300 skylights 0 0 0 windows 564 21,354 0 Totals 54,657 4,799 FENESTRATION LOADS AED Graph(mid-summer) 30,000 = 20,000 m 10.000 0 8 9 10 11 12 13 14 15 16 17 18 19 — BTUH —Average --- Average 1.3 This graph represents hourly aggregrate fenestration bads in mid-summer. AED graph(fall) 30,000 = 20,000 ti oa 10,000 0 8 9 10 11 12 13 14 15 16 17 18 19 — BTUH —Average Average'1.3 This graph represents hourly aggregrate fenestration bads in October. COMPONENT LOADS ABOVE Map trace wall Frame Wall,Wood framing, R-11 cavity Construction nr 12B-Os w Fxpusurc N Healing BTUH 459 insulation,Stucco or Siding. U Value: 0.097 Area 81.5 Cooling BTUH: 230 Map trace wary Frame`Nall,Wood framing,R-11 cavity construction nr: 12B-Os w Exposure: N Heating BTUH: 1.397 insulation, Stucco or Siding. U Value: 0.097 Area 248.3 Cooling BTUH: 701 Map trace wan Frame Wall,Wood framing, R-11 cavity construction nr 126-0s w Exposure E Healing BTUH 2,092 insulation, Stucco or Siding. U Value: 0.097 Area: 371.9 Cooling BTUH: 1,050 Map trace wall Frame Wall,Wood framing, R-11 cavity Construction nr: 126-0s w Exposure: S Healing BTUH: 1,831 insulation,Stucco or Siding. U Value: 0.097 Area: 325.4 Coding BTUH: 919 Map trace wan Frame Wall,Wood framing, R-11 cavity Construction rr. 12B-Os w Exposure: W Heating BTUH: 1,079 insulation, Stucco or Siding. u Value: 0.097 Area: 191.7 Cooling BTUH: 541 Map trice was Frame Wall,Wood framing, R-11 cavity Construction nr 12B-Os w Exposure: W Heating BTUH: 984 insulation, Stucco or Siding. U Value: 0.097 Area: 174.9 Cooling BTUH: 494 Map trace wall Frame Wall,Wood framing, R-11 cavity Construction nr 128-0s w Exposure: N Heating BTUH: 1,424 insulation, Stucco or Siding. U Value: 0.097 Area: 253.1 Coding BTUH: 714 Map trace wall Frame Wall,Wood framing, R-11 cavity construction nr 12B-Os w Exposure: E Heating BTUH: 1,375 insulation, Stucco or Siding. U Value: 0.097 Area: 244.4 Cooling BTUH: 690 Map trace wary Frame Wall,Wood framing, R-11 cavity Construction nr: 12B-Os w Exposure: S Heating BTUH: 1.442 insulation.Stucco or Siding. U Value: 0.097 Area: 256.3 Coding BTUH: 723 Map trace wall Frame Wall,Wood framing, R-11 cavity construction nr. 12B-Os w Exposure: w Healing BTUH: 1,360 insulation, Stucco or Siding. U Value: 0.097 Area: 241.8 Cooling BTUH: 683 BELOW There are no components for this section. Default small windows for wary id 5478900 Construction rn I G U Value: 0.87 Heating BTUH: 303 Window NFRC rated. Clear glass. Are sure N SHGC 0.67 Cooling BTUH: 144 Default medium windows for wall id 5478900 Construction nr 1G U Value: 0.87 Heating BTUH: 606 Window, NFRC rated,Clear glass. Area: 12Exposure: N SHGC. 0.67 Cooling BTUH: 289 Default smart windows for waN Id 5478902 Construction nr: i G U Value: 0.87 Healing BTUH. 606 Window, NFRC rated,Clear glass. Area: 12 Exposure: N SHGC 0.67 Coding BTUH: 289 Default medium windows for waN id 5478902 Construction or 1 G U Value: 0.87 Heating BTUH: 606 Window, NFRC rated,Clear glass. Exrposure: N SHGC. 0.67 Coding BTUH: 289 Default large windows for wall id 5478902 Construction nr. 1 G 36 U Value: 0.87 Healing BTUH 1,817 Window, NFRC rated,Clear glass. AreExposure: N SHGC: 0.67 Cooling BTUH: 866 Default small windows for wall Id 5478983 Construction nr 1 G U Value 0.87 Heating BTUH 606 Window, NFRC rated.Clear glass. Exposure E2 SHGC 0.67 Cooling BTUH: 492 Default medium windows for wall id 5478903 Construction nr. 1G U Value: 0.87 Healing BTUH: 1,817 Window. NFRC rated.Clear glass Area: 36 Exposure* E SHGC 0.67 Coding BTUH: 1,475 Default large windows for wall id 5478903 Construction nr 1G Area 36 U Value: 0.87 Heating BTUH: 1,817 Window. NFRC rated,Clear glas• Exposure: E SHGC 0.67 Coding BTUH: 1.475 Default small windows for wall id 5478904 Construction nr 1 G U Value 0.87 Healing BTUH 606 Window. NFRC rated,CICar glass Exposure: S2 SHGC 0.67 Cooling BTUH: 485 Default medium windows for wall id 5478904 Construction nr 1 G U Value: 0.87 Heating BTUH: 1,211 Window, NFRC rated,Clear glass. Exposure S4 SHGC 0.67 Cooling BTUH: 969 Default large windows for wall Id 5478904 Construction nr 1G U Value: 0.87 Heating BTUH: 1,817 Window, NFRC rated,Clear glass. Exposure: S SHGC 0.67 Cooling BTUH: 1,454 Default smaill windows for wait Id 5478899 Construction nr 1 G Area 12 U Value: 0.87 Heating BTUH: 606 Window. NFRC rated,Clear glass. Exposure: W SHGC: 0.67 Cooling BTUH: 547 Default medium windows for wal Id S478899 Construction nr 1 G U Value 0.87 Heating BTUH 1,817 Window, NFRC rated,Clear glass. Exposure: Vy SHGC 0.67 Cooling BTUH: 1.640 Default small windows for wall Id 5478901 Construction nr 1 G U Value: 0.87 Heating BTUH: 303 Window, NFRC rated,Clear glass. Area: 6 Exposure W SHGC: 0.67 Cooling BTUH: 273 Default medium windows for wall id 5478901 Construction nr 1 G U Value: 0.87 Heating BTUH: 1.817 Window, NFRC rated,Clear g18S5. Exposure: W SHGC 0.67 Cooling BTUH: 1,640 Default small windows for wall id 5478920 Construction nr iG U Value: 0.87 Heating BTUH: 606 WuidUw, NFRC rated, lleatglaSS' Area 12Exposure: N SHGC 0.67 Cooling BTUH: 289 Default medium windows for wall id 5478920 Construction nr 1G U Value: 0.87 Heating BTUH 606 Win NFRC rated,Clear glass. Area: 12Exposure: N SHGC: 0.67 Coding BTUH: 289 Default large windows for wall id 5478920 Construction nr 1G U Value: 0.87 Heating BTUH: 1,817 Window, NFRC rated,Clear glass. Area, 36 Exposure: N SHGC 0.67 Cooling BTUH: 866 Default small windows for wall id 5478921 Construction nr 1G U Value: 0.87 Heating BTUH: 606 Window, NFRC rated.Clear glass. Exposure: E2 SHGC 0.67 Cooling BTUH: 492 Default medium windows for wall id 5478921 Construction nr 1G U Value: 0.87 Heating BTUH. 606 Window, NFRC rated.Clear glass. Eripo 2 sure: E SHGC 0.67 Cooling BTUH: 492 Default large windows for wall id 5478921 Construction nr 1G U Value 0.87 Heating BTUH 1,817 Window, NFRC rated,Clear glass. Area: 36 Exposure. E SHGC 0.67 Coding BTUH: 1,475 Default small windows for wall id 5478922 Construction nr 1 G U Value: 0.87 Healing BTUH 606 Window, NFRC rated.Clear glass. Exposure g2 SHGC 0.67 Coding BTUH: 473 Default medium windows for wall id 5478922 Construction nr 1G U Value: 0.67 Heating BTUH: 606 Window. NFRC rated. Clear glass. Exposure: S2 SHGC 0.67 Coding BTUH: 479 Default large windows for wall id 5478922 Construction nr 1G U Value: 0.87 Heating BTUH. 1,817 Window, NFRC rated,Clear glass. Epo36 sure: S SHGC 0.67 Coding BTUH: 1,442 Default small windows fo►wap Id 5478919 Construction nr 1 G U Value 0.87 Healing BTUH 606 Window, NFRC rated,Clear glass. Exposure: W SHGC 0.67 Cooling BTUH: 547 Default medium windows for wall id 5478919 uchon nr: 1G U Value 0.87 Heating BTUH 606 Window,NFRC rated,Clear glass. Exposure: w SHGC: 0.67 Cooling BTUH: 547 Default large windows for wall id 5478919 Construction nr 1 GU Value' 0.87 Heating BTUH 1,817 Window, NFRC rated,Clear glass. Area: posure ti SHGC 0.67 Coding BTUH 1.640 Window cooling BTUHs shown here are daily average values.See AED graphs for details of fenestration loads during the day. Map trace generated ceiling Ceiling under attic or attic knee wall,Asphalt Construction nr: 16B-25 ad Area: 1,896.6 Heating BTUH: 4,180 shingles, Dark, R-25. ding BTUH 3,964 Map trace generated ceiling Ceiling under attic or attic knee wall,Asphalt Construction nr 168-25 ad Heating BTUH 2,595 shingles,Dark, R-25. U Value: 0.038 Area: 1,177.2 Coding BTUH: 2,460 SKYLIGHTS There are no components for this section Skylight cooling BTU Hs shown here are daily average values.See AED graphs for details of fenestration loads during the day. There are no components for this section. Map trace generated floor Floor over enclosed unconditioned crawl space Heating BTUH: 13,296 Construction nr 2,003.1 Healing U Value.0.295 Coding BTUH: 4,432 or basement,no floor insulation,Carpet or area: z,003.1 Coding U Velue:0.295 F Value: WA hardwood. VENTILATION There are no components for this section. HOT WATER PIPING There are no components for this section. System generated ducts(above conditioned space) EHLF 0,127 Heating BTUH 10.235 Attic-Radial ESGF: 0.168 Sensible BTUH: 7,845 ELG 433 Latent BTUH 433 INFILTRATION NUM Heating 294 Healing BTUH: 18.537 Leakage Category: Semi Loose NCFM Coofmg 138 Sensible BTUH: 3,307 Latenl BTUH 3,066 BLOWER • •• There are no components for this section. HUMIDIFICATIONWINTER There are no components for this section. �- •'�4•£ssm..5s����g �P� S-=.�".. ^��: t di'��V•9Y� ! ;U�..- b�:,`s � AN •�'� .:w._ .i: is- Ao`. �#;$#".►� :�. ... �# .•4--. �t. �rl�`.fF ?k`a. k"•"''� x -: ... r .' ., t�'["�FlaR� :fi�.�S!e _ "�J6` �F� -„��'�� '•fta Ao 17,74 r • �e OCCUPANTS Nr.Occupants: 5 Sensible BTUH: 1,150 Latent BTUH: 1,000 APPLIANCES Kitchen,utility room.additional fridge,lighting:3.400 BTUH Quantity: Sensible BTUH: 3,400 Latent BTUH. Plant Size: small Quantity: 5 Latent BTUH: 50 Plant Size medium Quantity: 5 Latent BTUH 100 Plant Size: large Quantity: 5 Latent BTUH: 150 ROOM DETAIL Room name:First floor Heated square footage: r r Total Cooling BTUH: Cooled square footage: Total Heating BTUH: Heated volume(above grade CF): s®i CFM: Cooled volume(above grade CF): Exposed wall area(SF): Load Calculation Cooling Heating 0 20.000 40,000 60,000 BTUH AED Graph(mid-summer) 20.000 2 10,000 m 0 8 9 10 11 12 13 14 15 16 17 18 19 — BTUH —Average -- Average 1.3 AED graph(fall) 15,000 = 10,000 ti m 5,000 0 8 9 10 11 12 13 14 15 16 17 18 19 — BTUH — Average Average'1.3 ROOM DETAIL Room name:Second Floor Heated square footage: ® Total Cooling BTUH: Cooled square footage: ® Total Heating BTUH: Heated volume(above grade CF): � CFM: Cooled volume(above grade CF): Exposed wall area(SF): Load Calculation Cooling Heating 0 10,000 20.000 30,000 40,000 BTUH AED Graph(mid-summer) 15,000 = 10,000 ti Co 5.000 0 8 9 10 11 12 13 14 15 16 17 18 19 — BTUH —Average — Average 1.3 AED graph(fall) 15,000 10,000 ti co 5,000 0 8 9 10 11 12 13 14 15 16 17 18 19 — BTUH —Average Average'1.3 r SUBMITTAL DATA: 111WALL-MOUNTED System Reference: --- -------_-- Date ----------- Yrdoor Unit: Outdoor Unit: _—Wireless Remote control" MSZ-WRIBNA .,MUZ-WRI8NA-W MUZ-WRI8NA-U2 GENERAL FEATURES • Single-zone heat pump systems • Blue Fin anti-wnosion treatment applied to the outdoor unit heal exchanger for increased cod protection and longer He • Four fan speeds-Low Medium.High,Super-high • Anti-mold fillor • INVERTER-driven heal pump • Coding operation range:32'F to 1t 5°F • Heating operation range:5"F to 75'F • Multiple control options available. -Hand-held Remote Controller(provided with unit) kumo cloud"smart device app for remote access -Third-party interface options -Wired or wireless controllers • 12-hour timer • ECONO COOL mode • AUTO restart • The outdoor unit powers the indoor unit and should a power adage occur,the system is automatically restarted when the power returns. Specifications are subject to change without notice. c,2022 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. SPECIFICATIONS: - ; - Maximum Capacity BTUIH 18,000 Rated Capacity BTU/H 17.200 Minimum Capacity -- _ BTUM 5,8W Maximum Power Input w 2,170 Coding at 95°F Rated Power Input w 1.720 Moisture Removal Pints/h 2.1 Sensible Heat Factor 0.86 Power Factor(208/230V) — —_—T % gglgg _---- Maximum Capacity BTU/H 19A72 Rated Capacity BTU/H 18.700 Coding at 82"F Minimum Capacity BTU/H 6,404 Maximum Power Input w 1,955 Rated Power Input W 1,548 Maximum Capacity BTU/H 2O,900 Rated Capacity —— ------ BTII/H 18.000 Minimum Capacity BTU/H 5,400 Heating at 47`F= --- — Maximum Power Input w 2,360 Rated Power Input w 1,670 Power Factor --- — -- % 97197 Maximum Capacity BTUtH 15,000 Rated Capacity BTU/H 11,500 Hooting at 17°F3 L---- ---- Maximum Power Input w 2.040 Rated Power Input w 1,360 Maximum Capacity BTU/H 12,730 Hosting at 5'Fr Maximum Power Input w 1.770 SEER I SEER2 16.0 1 18.0 EER'i EER2' 10.01 10.0 NSPF(IV)I HSPF2(IV) 8.518.5 Efficiency, COP at 47°F2 3.16 COP at 17'F In Maximum Capacity3 2.16 COP at 5`F in Maximum Capacity' 2.12 ENERGY STAR®certified units(ENERGY STAR products are third-party certified by an EPA-recognized Certification Body.) NO Voltage.Phase,Frequency 2D8/230V.1 phase,80Hz Guaranteed Voltage Range VAC 187.253 Voltage Indoor-Outdoor,S1-82 VAC 208231) Electrical V age:Indoor-Outdoor,S2S3 V DC 24 Short-circuit Current Rating(SCCR) kA 5 Recommended /Breaker Size(Outdoor) -._... A 15 Recommended Wire Sin(indoor-Outdoor) AWG 14 MCA A 1 �I glower Motor Full Load Amperage A 0.67 Blower Motor Output -... - - w 30 Airflow Rate at Cooling,Dry CFM 625-530-431-328 Aidbw Rate at Coding,Wet-- -_.... CFM 562.47738&295 Airflow Rate at Heating,Dry CFM 625530.431307 Indoor Unit - Sound Pressure Level(Cooling) dB(A) 47-423730 -Sound Pressure Level(Heating) dB(A) 47-4237-30 '.,Drarn Pipo Sizo In.(mm) 5/8(15.88) Heat Exchanger Type - - -- - -- Plate fin coil External Finish Color Munsep 1.OY 9202 Unit Dimensions - ?—W In.(mm) 36-5116(923) Specifications are subject to change without notice. n 2022 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. SPECIFICATIONS: - - i D:In.(mm) 9-13/16(250) H:In.(mm) 12(305) W-In.(mm) 39 ON) Package Dimensions D:In.(mm) 13(330) H:In.(mm) 15(380) Unit Weight — - -- Lbs.(kg) 28(13) Package Weight Lbs.(kg) 33(15) Indoor Unit Oparahng I Cooing Intake Air Temp,(MaxMkan/Minimum)'_ - -- _-- °F 90F D.B/73F WB//67F DB 57F W.B --- ------------------ Temperature Range Heating Intake Air Temp(Maximum,Minimum) 'F 80F DB//70F D.B ------- MCA A 10 MOCP A 15 Fan Motor Full Load Amperage A OS Fan Motor Output W 55 Airflow Rate CFM 1,243/1,229 Refrigerant Control LEV Defrost Method Reverse cycle Heat Exchanger Type Plate fin cell Blue Fin Coating on Heat Exchanger Yes Sound Pressure Level,Cooling' dB(A) 53 Sound Pressure Level.Hooi dB(A) 51 i Conviessor Type DC INVERTER-driven Twin Rotary Compressor Model SN8130FQBMT Outdoor Unit — Compressor Rated Load Amps A 7A Compressor Locked Rotor Amps A 9.3 Compressor Oil Type 1/Charge oz. FV50S//11.8 External Finish Color Ivory Munsell 3Y 701.1 Base Pan Heater_—_ - ---Option W:In.(mm) 31-1112(800) Unit Dimensions D:in.(mm) 11-114(285) H:In.(mm) 21-518(550) W:In.Ilion) 38-9/16(980) Package Dimensions D:In.(mm) 16-9/16(420) H:M.(mm) 39(990) Unit Weight Lbs.(kg) 81(37) Package Weight Los.(kg) 88(40) Cooing Air Temp(Maximum/Minimum)' °F 115,32 Outdoor Unit Operating Cooing Thermal Lode-out/Restart Temperatures- °F -1/3 Temperature Range Healing Air Temp(Maximum i Minimum) °F 75/5 Heating Thermal Lockout/Re-start Temperatures— 'F .9/.4 --- — Type R410A Refrigerant -- Charge Los,oz 2,10 ------ Gas Pipe Size O.D.(Flared) _--- — In.(mm) 1/2(12.7) Liquid Pipe Size O.D.(Flared) In.(mm) 1/4(6.35) Prying Maximum Piping Length Ft.(m) 65(20) Maximum Height Difference — FL(m) 40(12) -- Maximum Number of Bends ----__ 10 Notes 'Cooling(Indoor//Outdoor) -- °F 80 DB.67 WB H 95 DB,75 WB AHRI Rated Conditions(Rated data is determined at a fixed 'Heating at 47'F(Indoor//Outdoor) °F 70 DB,60 We//47 DB,43 WB compressor Wood) -- "Heating at 17'F(Indoor 11 Outdoor) -F 70 DS,60 WB 1117 DB,15 WB Conditions_---- 41-loating at 5°F(Indoor it Outdoor) °F 70 DB,60 WB 115 D8,4 WB °Appications should be restricted to comfort cooling only:equipment:cooling applications are not recommended for low ambient temperature conditions. "System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. Specifications are subject to change without notice. ©2022 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. ACCESSORIES: - Anti-allergy Enzyme Filter - -- --- -------- - o MAC-408FT-E Renate Controller Holder a U01A01083 kumo touch-RedUNKTM Wireless Controller ❑MHK2 Deluxe MA Remote Controller' ❑PAR-40MAAU Simple MA Controller' - - ---- ❑PAC-YT53CRAl1J Touch MA Controller' ---- - - ----- --- u PAR-CT01 MAU-SB Wireless Temperature and Humidity Sensor n PAC-USWHS003-TK1 System Control Inlerface7 a MAC-334IF-E Wireless Interface 2 ❑PAC-USWHS002-WF-2 -------------------------------------- Thermostat Interface a PAC-US444CN-1 Thermostat Interface o PAC-US445CN-1 kumo station''for kumo doude o PAC-WHSOIHC-E USNAP Interface ❑PAC-WHS01UP-E IT Extender o PAC•WHS011E-E BACraP°and MODBUSe Interface a PAC-UKPRC001-Cf4.1 Lockdown Bracket for Hand-held Renate Controllers u RCMKPICB Blue Diamond Sensor Extension Cable-15 Ft. n C13-103 Blue Diamond Alarm Extension Cable-6.5 Ft. o C13-192 Blue Diamond Mukr rank-collection tank for use with multiple pumps a C21-014 Blue Diamond Rubber Foot Pads o F10-010 Mini Condensate Pump-230 vole application o S130.230 MegaBlue Advanced Blue Diamond Condensate Pump w/Reservoir 3 Sensor a X87-835-110 to 250V MexiBlue Advanced Blue Diamond Mini Condensate Pump w/Reservoir 8 Sensor(110V)up to 48,000 BTU/H[recommended[ u X87-711-110V Advanced Blue Diamond Mini Condensate Pump w/Reservoir 8 Sensor(208/230V)[recommended] o X87-721-208/230V MicroBlue Blue Diamond Mini Condensate Pump(110/208/230V)up to 18,000 BTU/H ❑XW. W3 Fascia Kit for MlcroBlue Pump-mounts the MicroBlue and sensor directly beneath the Indoor unit u T18-016 Refco Condensate Pump(100.240 VAC)up to 120,000 BTUM a COMBI Refoo Condonsate Pump II DO-240 VAC)up to 120,ODO BTUM a G08141 Dram Pan Level Sensor o SS610E (30A1600VrULf(Ms 2'X 4'utility box]-Black a TAZ-MS303 (30A/6600VA)L)(fits 2'X 4'utility box]-While a TAZ-MS303W Flexible Mlni•Splil in Hose ❑M-16 'Requires MAC-3341F-E Allows indoor units to connect to an MA Controller Specifications are subject to change without notice. O 2022 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. ACCESSORIES: Air Outlet Guide c MAC-88ISG Drain Socket o MAC-860DS Optional Defrost Heater --- -- -- c MAC 640BH-U Hai Guard c HG-B4 Outdoor Unit 3-1/4 inch Mounting Base(Pair)-Plastic DSO-400P Condensing Unit Mounting Pad 16"x 36"x 3" ULTRIUTEI Outdoor Unit Stand—12"High ---_ n.QSMS1201M Outdoor Unit Stand—18"High u QSMS1801M Outdoor Unit Stand—24"High a OSMS2401M Heavy Duty Wal Mounting Bracket—Coated Steel_-_--- — --_-_— - -----—_-- ❑QSWB2000M-1—_ Heavy Duly Wel Mounting Bracket-316 Series Stainless Steel c QSWBSS 15'x 1/4"x 15' 122-Lineset(Twin-Tube Insulation) o MLS141212T-15 30'x 1%4"x NT 112"Lineset(Twin-Tube Insulation) ❑MLS141212T-30 50'x 1/4"x 50',1;2"Lineset(Twin•Tube Insulation) ❑MLS141212T-50 65'x 1/4"x 65'i 17 Lineset(Turin-Tuba Insulation) u MLS141212T-65 100'x 1/4'x 100'i 1 iY Lineset(Twin-Tube Insulation) MLS141212T-100 Specifications are subject to change without notice. ©2022 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. DIMENSIONS: MSZ-WR18NA 7116x13116 Installation plate Obb Indoorurit Ix7116 Oblong hole 3-11!16 36-5116 3.11!16 8.7/8 8-7/8 35.13116 1/44 o m '— F I I I I Io c cl rn 9.13116 B-11/16 a 3116 2S116 IS718 15.3/16 A3 Air in Wall hole 03 Installation plate a 2-1/2 2-1116 27-1516 6 5116 tV O \ Drain hose 2r� O SEE& 2- 4-121/2 � Air out 5,314 2.9l16 2-9116 N � 3-11/16 �s N (y N 18 KBTU/H 24 KBTU/H om ion 02 O.D o Insulation 02 O.D ine 05116 15-318 Flared connection 01/4 a Liquid line 05/16 15-3/8 (Flared connection 0318) ane 015l32 13-3l8 Flared connection 01/2 a Gas ine 015/32 13 3I8 Flared connection 0518 Drain hose Insulation 01-1/8 Connected part 05/8 0.1) Drain hose Insulation 01-1/8 Connected Dart 05/8 O.D Specifications are subject to change without notice. 0 2022 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. DIMENSIONS: MUZ-WR18NA Unit: inch REQUIRED SPACE `1 4 in. (100 mm) or more when front and sides of the unit are clear �o m q/�r1� 0.`�o< ce 15-3/4 At n Dron hole 01-21/32 Ar n c m 6\n.�20c6 Z or sO� o oc \ $� '2 When any 2 sides of left, right 1-9/16o and rear of the unit are Gear At oul 2-holes 3/8x13/16 Service anal 7/8 11/16 Handle Liquid refrigerant pipe joint Refrigerant pipe(flared)a 1/4 � N N m m Gas refrigerant pipe joint rn n ry ^ Refrigerant pipe(flared)a 3/8(09/12 KBTU/H Nv n n 0 1!2 18 KBTUlH) ry m m 1-29/3 5-1v 32 -15/1 19-11/16 6-23/32 Bolf pdch for nslallahan 31-1/2 2-3/4 1340 SAMll t�El wl—rd.S.—n ,GA 30024 Toll Fro 800-433-4822.nw—hvgc— oOw FORW MSZ-WR18KA/MU7-WR18RA-202200 YNertdl Specifications are subject to change without notice. ©2022 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. 810765-UTG-A-0313 TECHNICAL DESCRIPTION The Air Handler line offers the ultimate in comfort, sound and application flexibility. The air handler is shipped ready to be GUIDE installed in upflow, horizontal left or right position, with minor adjustments. No special kits are required to install this deluxe product. All JCI Unitary Products air handlers and coils use a TXV to pro- vide our customers with the optimum performance and refriger- SINGLE PIECE 4 POSITION ant control. Air handlers are shipped with "Flex-coils" without a AIR HANDLERS factory installed metering device. For added flexibility. an R-22 or R-410A TXV or orifice can be field installed to meet your STANDARD PSC refrigerant choice. MODELS: RFCX*P SERIES FEATURES Thermal Expansion Valve - Provides the ultimate refrigerant control required for today's high efficient product.The UPG bolt- on TXV provides the added flexibility to convert the air handler to the required refrigerant.The UPG TXV is a true bolt-on which does not require brazing to replace or install. Insulated Cabinet-All air handler cabinets are thermally insu- lated with 3/4"foil faced insulation to prevent sweating. Factory Sealed-Achieves 2%or less total airflow leakage rate at duct blaster field test conditions for system airflow verifica- tion. Durable Finish Inside and Out-Air handier casings are made of pre-painted galvanized steel which provides a better paint to steel bond that resists corrosion and rust creep.All internal coil sheet metal parts are made of G60 galvanized or prepainted G30 galvanized. Filters -All models have internal filter racks provided for use with 1"thick standard size filters. Electric Heat Kits - New 6HK series of field installed electric heat kits are available for installation friendly and easy service applications.These 6HK kits are unique to these new models. C U(.) L us ISO 9001 LISTED Certified Quality Management System Due to continuous product improvement, specifications are subject to change without notice. Visit us on the web at: www.upgnet.com Additional rating information can be found at: www.ahridirectory.org WARRANTY Standard 5-year limited parts warranty. Extended 10-year limited parts warranty when product is registered online within 90 days of purchase for replace- ment or closing for new home construction. FOR DISTRIBUTION USE ONLY-NOT TO BE USED AT POINT OF RETAIL SALE 810765-UTG-A-0313 DIMENSIONS S DUCT CONNECTION DIMENSIONS J ey i e K �h i Blower Compartment Top Outlet Dimensions A Circuit Breaker Panel Refrigerant D Drain connections Connections for upflow Applications 7-11132' � 1 8� E 1-1+z c Bottom Inlet Dimensions e Filter Drain Pan Connections Access for Horizontal Applications Dimensions'! Dimensions Wiring Knockouts Refrigerant Connections Models A 8 C J K D E F Line Size Height Width Depth Power Control Liquid Vapor RFCX18BP/RFCX24BP/ 46 17112 161/2 13-29/32 161/2 7/g 112 RFCX30BPIRFCX36BP ( ) 3/4 21 1/2 1-3/8(1) 7l8(1/2) 3/8 RFCX42CP 52 21 21 112 17-13/32 20 1-23/32(1-1/4) RFCX48DP/RFCX60DP 57 24112 26 20-29/32 23-1/2 7/8 1. All dimensions are in inches. 2. Actual size(conduit size). COIL TECHNICAL DATA Models Application Refrig. Face Area Rows Fins Coil Size Tube Tube Fin Conn.Types (Sq.Ft.) Deep Per In. Geometry Dia. Type RFCX186P Cooling Meat Pump Sweat 3.4 2 14 (2)14 x 17.5 1 x 0.866 3/8 Enhanced RFCX24BP Cooling/Heat Pump Sweat 3.9 3 12 (2)16 x 17.5 1 x 0.866 3/8 Enhanced RFCX30BP Cooling/Heal Pump Sweat 3.9 3 12 (2)16 x 17.5 1 x 0.866 3/8 Enhanced RFCX36BP Cooling/Heat Pump Sweat 4.9 3 12 (2)20 x 17.5 1 x 0.866 3!8 Enhanced RFCX42CP Cooling/Heat Pump Sweat 5.4 3 12 (2)22 x 17.5 1 x 0.866 3/8 Enhanced HFCX48UP Cooling/Heat Pump Sweat 5.8 3 11 (2)24 x 17.5 1 x 0.866 3/8 Enhanced RFCX60DP Cooling/Heat Pump Sweat 6.8 3 12 (2)28 x 17.5 1 1 x 0.866 3/8 Enhanced 2 Johnson Controls Unitary Products 810765-UTG-A-0313 COOLING CAPACITY' Models Rated CFM2 Entering Air MBH@ Evap.Temp.and Corresponding R-410A Pressure('F/PSIG) DryMet Bulb('F) 351107.9 1 40/118.9 451130.7 50/143.3 FULL-CASED"A"TYPE MULTI-POSITION 85/72 40.7 35.6 30.5 24.1 RFCX18BP 665 80/67 35.0 29.5 23.9 18.6 75/62 27.9 22.7 18.1 12.4 70/57 22.1 19.8 16.9 14.1 85/72 47.9 42.4 36.8 29.9 RFCX24BP 740 80/67 40.9 35.2 29.0 22.6 75/62 33.6 28.0 21.7 15.5 70/57 26.2 23.0 19.9 16.9 85/72 65.8 60.4 50.7 41.5 RFCX30BP 1115 80/67 58.0 49.5 39.9 31.2 75/62 47.1 38.9 30.4 21.1 70/57 37.1 33.1 28.2 23.9 85/72 71.1 62.4 51.5 44.3 1060 80/67 592 51.0 42.0 32.7 75/62 48.0 39.6 30.8 21.8 RFCX36BP 70/57 37.3 32.8 28.3 24.0 85/72 83.2 66.7 60.1 48.9 1245 80/67 66.0 59.5 47.8 37.1 75/62 55.0 45.2 35.5 24.8 70/57 42.9 38.1 32.6 27.6 85172 68.2 72.9 62.8 51.6 1230 80/67 66.3 59.7 48.6 38.4 75/62 56.4 45.4 36.1 25.5 RFCX42CP ' 70/57 43.7 38.3 33.3 28.3 85/72 69.8 86.0 74.0 59.1 1485 I 80/67 68.5 69.5 56.6 44.2 75/62 65.3 54,1 42.0 29.8 70/57 51.0 45.4 39.1 32.8 85/72 87.5 75.9 64.4 51.7 1320 80/67 71.2 59.9 49.8 37.2 75/62 56.5 46.6 35.4 23.3 RFCX48DP 70/57 43.5 39.5 34.0 28.4 85/72 102.3 90.1 76.1 60.5 1610 80/67 83.7 71.5 57.3 43.6 75/62 67.0 54.0 41.2 27.0 70/57 50.9 46.6 39.8 33.4 85/72 93.7 82.0 70.0 57.4 1350 80/67 76.5 65.5 54.1 41.4 75/62 60.9 50.3 38.4 26.2 70/57 46.6 41.6 35.5 29.8 85/72 70.8 96.4 82.4 66.2 RFCX60DP 1620 80/67 89.9 76.0 62.8 47.3 75/62 71.4 58.3 44.8 29.9 70/57 55.0 48.4 41.9 34.9 85172 126.4 110.6 92.8 74.5 1870 80/67 102.1 86.3 70.0 53.1 75/62 81.5 65.6 50.0 34.1 70/57 62.1 55.3 47.1 39.4 1. Actual capacity varies with the outdoor AC or HP that is used with the system. 2. Airflow is calculated for each system tonnage. Johnson Controls Unitary Products 3 810765-UTG-A-0313 APPLICATION FACTORS-RATED CFM VS.ACTUAL CFM %.Of Rated Airflow(CFM) 80% 90% 100% 110% 120% Capacity Factor 0.96 0.98 1.00 1.02 1.03 PHYSICAL&ELECTRICAL DATA-COOLING ONLY Models RFCX18BP RFCX24BP RFCX30BP RFCX36BP RFCX42CP RFCX48DP RFCX60DP Blower-Diameter x Width 10 x 8 10 x 8 10 x 8 10 x 8 10 x 10 10X10 10X10 Motor HP 1/4 HP 114 HP 3/4 HP 3/4 HP 3/4 HP 3!4 HP 3/4 HP Nominal RPM 1075 1075 1075 1075 1075 1075 1075 Voltage 208/230 208/230 208/230 208/230 2081230 2081230 208/230 Full Load Amps @230V 1.4 1.4 3.0 3.0 3.0 3.0 3.0 Type DISPOSABLE OR PERMANENT Filterl Size 16x20x1 16x20xl 16x20x1 16x20x1 20x20x1 22x20xl 22x20x1 Permanent Type Kit lPF0601BK lPF0601BK lPF0601BK IPF0601BK lPF0602BK IPF0603BK IPF0603BK Shipping/Operating Weight(lbs.) 112/100 117/1 D2 117/105 1221110 148/133 1651147 168l150 1. Field Supplied. KW&MBH CONVERSIONS-FOR TOTAL POWER INPUT REQUIREMENT For a power distribution voltage that is different than the provided nominal voltage, multiply the kW and MBH data from the table by the conversion factor in the following table. DISTRIBUTION POWER NOMINAL VOLTAGE CONVERSION FACTOR 220V 240V 0.84 ELECTRICAL DATA-COOLING ONLY Models Minimum Circuit Motor FL Al Ampacity MOPZ Minimum Wire Size(AWG)3 RFCXI8BP/RFCX248P 1.4 1.8 15 14 RFCX30BP/RFCX36BP/JFQII#2CP/ " RFCX48DP/RFCX60DP 3.0 3.8 15 14 1. FLA=Full Load Amps 2. MOP=Maximum Overcurrent Protection device;must be HACR type circuit breaker or time delay fuse. 3. 75C,copper wire only. If wire other than non-plated.75°C ambient,copper wire Is used,consult applicable tables of the NEC and local codes.. ELECTRICAL HEAT.MINIMUM FAN SPEED Nom.kW Air Handler Models Heater Kit Modelsl 2 @240V RFCX18BP RFCX24BP RFCX30BP RFCX36BP RFCX48DP RFCX60DP 6HK(0,1)6500206 2.4kW Low Low Low Low EQ Low Low 6HK(0,1)6500506 4.8kW Med Low Low Low Low Low 6HK(0,1)6500806 7.7kW Med Med Med Med Maidif Low Low 6HK(0,1)6501006 9.6kW Med High Med High Maid! Med Med 6HKO6501025 6HK(1,2)6501306 12.5kW High High High Hip Med Med 6HK(1,2)6501506 14.4kW - High High High High Med Med 6HKO6501525 6HK(1,2)6501806 17 3kW - - High Med Med 6HKO6501825 6HK(1,2)6502006 192kW - High - High High 6HK16502025 6HK(1,2)6502506 24kW -6HK16502525 - High 1. (0,1)-0=no circuit breaker OR 1=with circuit breaker. 2. (1,2)-1=with circuit breaker,no breaker jumper bar OR 2=with circuit breaker&breaker jumper bar. 4 Johnson Controls Unitary Products 810765-UTG-A-0313 ELECTRIC HEAT PERFORMANCE DATA: 208/230-1-60&208/230-3.60 Total Heat3 kW Staging Heater Nominal kW Models � @ t z 240V kW MSH W1 Only W1 +W2 208V 230V 208V 230V 208V 230V 208V 230V 6HK(0,1)6500206 2.4 1.8 2.2 6.2 7.5 1.8 2.2 1.8 2.2 6HK(0,1)6500506 4.8 3.6 4.4 12.3 15.0 3.6 4.4 3.6 4.4 6HK(0,1)6500806 7.7 5.8 7.1 19.7 24.1 5.8 7.1 5.8 7.1 6HK(0.1)6501006 9.6 7.2 8.8 24.6 30.1 7.2 8.8 7.2 8.8 1PH 6HK(1,2)6501306 12.5 9.4 11.5 32.0 39.2 3.1 3.8 9.4 11.5 6HK(1.2)6501506 14.4 10.8 13.2 36.9 45.1 3.6 4.4 10.8 13.2 6HK(1,2)6501806 17.3 13.0 15.9 44.3 54.2 6.5 7.9 13.0 15.9 6HK(1,2)6502006 19.2 14.4 17.6 49.2 60.2 7.2 8.8 14.4 17.6 6HK(1,2)6502506 24.0 18.0 22.0 61.5 75.2 7.2 8.8 18.0 22.0 6HKO6501025 9.6 7.2 8.8 24.6 30.1 7.2 8.8 7.2 8.8 6HKO6501525 14.4 10.8 13.2 36.9 45.1 10.8 13.2 10.8 13.2 3PH 6HKO6501825 17.3 13.0 15.9 44.3 54.2 13.0 15.9 13.0 15.9 6HK16502025 19.2 14.4 17.6 49.2 60.2 7.2 8.8 14.4 17.6 6HK16502525 24.0 18.0 22.0 61.5 75.2 9.0 11.0 18.0 22.0 1. (0,1)-0=no circuit breaker OR 1=with circuit breaker. 2. (1,2)-1=with circuit breaker,no breaker jumper bar OR 2=with circuit breaker 8 breaker jumper bar. 3. For different power distributions,see conversion table on Page 4. ELECTRICAL DATA FOR SINGLE SOURCE POWER SUPPLY: 2081230-1-60 Heater Heater Field Wiring Air Handler Models Amps Min.Circuit Ampacity MOP.3 Min Wire Size AWG 4 Modelst�z @240V ( ) 208V 230V 208V 230V 208V 230V 6HK(0,1)6500206 10.0 12,6 14.3 15 15 12 12 RFCX18BP 6HK(0,1)6500506 20.0 23A 26.8 25 30 10 10 6HK(0,1)6500806 32.0 36.4 41.8 40 45 8 8 6HK(0,1)6501006 40.0 45.1 51.8 50 60 8 6 6HK(0,1)6500206 10.0 12.6 14.3 15 15 12 12 6HK(0,1)6500506 20.0 23.4 26.8 25 30 10 10 RFCX24BP 6HK(0,1)6500806 32.0 36.4 41.8 40 45 8 8 6HK(0,1)6501006 40.0 45.1 51.8 50 60 8 6 6HK(1,2)6501306 52.0 58.1 66.8 60 70 6 4 6HK(1,2)6501506 60.0 66.8 76.8 70 80 4 4 6HK(0,1)6500206 10.0 14.6 16.3 15 20 12 12 6HK(0,1)6500506 20.0 25.4 28.8 30 30 10 10 RFCX30BP 6HK(0,1)6500806 32.0 38.4 43.8 40 45 8 8 RFCX42CP 6HK(0,1)6501006 40.0 47.1 53.8 50 60 6 6 6HK(1,2)6501306 52.0 60.1 68.8 70 70 6 4 6HK(1,2)6501506 60.0 68.8 78.8 70 80 4 4 6HK(0,1)6500206 10.0 14.6 16.3 15 20 12 12 6HK(0,1)6500506 20.0 25.4 28.8 30 30 10 10 6HK(0,1)6500806 32.0 38.4 43.8 40 45 8 8 RFCX38BP 6HK(0,1)6501006 40.0 47.1 53.8 50 60 8 6 RFCX48DP 6HK(1,2)6501306 52.0 60.1 68.8 70 70 6 4 6HK(1,2)6501506 60.0 68.8 78.8 70 80 4 4 6HK(1,2)6501806 72.0 81.8 93.8 90 100 4 3 6HK(1,2)6502006 80.0 90.4 103.8 100 110 3 2 Continuation on Page 6. Johnson Controls Unitary Products 5 810765-UTG-A-0313 ELECTRICAL DATA FOR SINGLE SOURCE POWER SUPPLY: 208/230-1-60(Continued) Heater Heater Field Wiring Air Handler Models 1 2 Amps Min.Circuit Ampacity MOP.3 Min Wire Size(AWG)4 Models • @240V 208V 230V 208V 230V 208V 230V 6HK(0,1)6500206 10.0 14.6 16.3 15 20 12 12 6HK(0,1)6500506 20.0 25.4 28.8 30 30 10 10 6HK(0,1)6500806 32.0 38.4 43.8 40 45 8 8 6HK(0,1)6501006 40.0 47.1 53.8 50 60 8 6 RFCX60DP 6HK(1,2)6501306 52.0 60.1 68.8 70 70 6 4 6HK(1,2)6501506 60.0 68.8 78.8 70 80 4 4 6HK(1,2)6501806 72.0 81.8 93.8 90 100 4 3 6HK(1,2)6502006 80.0 90.4 103.8 100 110 3 2 6HK(1,2)6502506 100.0 112.1 128.8 125 150 2 1 1. (0,1)-maybe 0(no circuit breaker)or 1(with circuit breaker). 2. (1,2)maybe 1(with circuit breaker,no breaker jumper bar)or 2(with circuit breaker&breaker jumper bar). 3. MOP=Maximum Overcurrent Protection device;must be HACR type circuit breaker or time delay fuse. 4. Stated sizes are for 75'C.copper wire only. If wire other than non-plated.75°C ambient.copper wire is used,consult applicable tables of the NEC and local codes. ELECTRICAL DATA FOR MULTI-SOURCE POWER SUPPLY: 2081230-1-60 Min.Circuit Ampacity MOP, Min.Wire Size(AWG)2 Air Total Heater Heater 208V 230V 208V 230V 208V 230V Handlers Models Amps Models p Circuit Circuit Circuit @240V 1st3 2nd 3rd 1st3 2nd 3rd 1st3 2nd 3rd 1st3 2nd 3rd 1st3 2nd 3rd 1st3 2nd 3rd RFCX24BP 6HK16501306 52.0 20.6 37.6 23.4 43.3 25 40 25 45 10 8 10 8 6HK16501506 60.0 23.5 43.3 26.8 50.0 25 45 30 50 10 8 10 8 RFCX30Bp 6HK16501306 52.0 22.6 37.6 25.4 43.3 25 40 - 30 45 10 8 - 10 8 RFCX42CP 6HK16501506 60.0 25.5 43.3 - 28.8 50.0 - 30 45 30 50 - 10 8 - 10 8 6HK16501306 52.0 22.6 37.6 - 25.4 43.3 - 25 40 30 45 10 8 10 8 RFCX36BP 6HK16501506 60.0 25.5 43.3 - 28.8 50.0 - 30 45 30 50 10 8 10 8 RFCX48DP 6HK16501806 72.0 42.8 39.0 - 48.8 45.0 - 45 40 50 45 8 8 8 8 6HK16502006 80.0 47.1 43.3 - 53.8 50.0 - 50 45 60 50 8 8 6 8 6HK16501306 52.0 22.6 37.6 - 25.4 43.3 - 25 40 30 45 10 8 10 8 6HK16501506 60.0 25.5 43.3 28.8 50.0 30 45 30 50 10 8 10 8 RFCX60DP 6HK16501806 72.0 42.8 39.0 - 48.8 45.0 - 45 40 50 45 8 8 8 8 6HK16502006 80.0 47.1 43.3 53.8 50.0 - 50 45 60 50 8 8 6 8 6HK16502506 100 47.1 43.3 121.7 53.8 50.0 25.0 50 45 25 60 50 25 6 6 10 6 8 10 1. MOP=Maximum Overcurrent Protection device;must be HACR type circuit breaker or time delay fuse. 2. Stated sizes are for 75'C,copper wire only. If wire other than non-plated,75'C ambient,copper wire is used.consult applicable tables of the NEC and local codes. 3. 1st Circuit includes the blower motor amps. 6 Johnson Controls Unitary Products 810765-UTG-A-0313 ELECTRICAL DATA FOR SINGLE SOURCE POWER SUPPLY-208/230-3-60 Heater Field Wiring Air Handler Models Heater Amps Min.Circuit Am ci Models p � tY MOP, Min.Wire Size(AWG)2 @ 240V 208V 230V 208V 230V 208V 230V RFCX18BP 6HKO6501025 23.1 26.8 30.7 30 35 10 10 RFCX24BP 6HKO6501025 23.1 26.8 30.7 30 35 10 10 6HKO6501525 34.6 39.2 45.0 40 45 8 8 RFCX30BP 6HKO6501025 23.1 28.8 32.7 30 35 10 8 RFCX42CP 6HKO6501525 34.6 41.2 47.0 45 50 8 8 6HKO6501025 23.1 28.8 32.7 30 35 10 8 RFCX36BP 6HKO6501525 34.6 41.2 47.0 45 50 8 8 RFCX48DP 6HKO6501825 41.6 48.8 55.8 50 60 8 6 6HK165020253 46.2 53.8 61.5 60 70 6 6 6HKO6501025 23.1 28.8 32.7 30 35 10 8 6HK06501525 34.6 41.2 47.0 45 50 8 8 RFCX60DP 6HKO6501825 41.6 48.8 55.8 50 60 8 6 6HK165020253 46.2 53.8 61.5 60 70 6 6 6HK165025253 57.7 66.3 75.9 70 80 4 4 1. MOP=Maximum Overcurrenl Protection device,must be HACR type circuit breaker or time delay fuse. 2. Stated sizes are for 75"C,copper wire only. If wire other than non-plated,75'C ambient,copper wire is used,consult applicable tables of the NEC and local codes. 3. The 20kW and 25kW heater models(6HK16502025 and 6HK16502525)come with circuit breakers standard.Single source power MCA and MOP requirements are given here only for reference if used with field installed single point power modification. ELECTRICAL DATA FOR MULTI-SOURCE POWER SUPPLY:208/230-3-60 Min.Circuit Ampacity MOP, Min.Wire Size(AWG)2 Heater Total Heater 208V 230V 208V 230V 208V 230V Air Handler Models Models Amps @ 240V Circuit Circuit Circuit 1st3 2nd 1st3 2nd 1st3 2nd 1st3 2nd 1st3 2nd ist3 2nd RFCX36BP 6HK16502025 46.2 28.8 25.0 32.6 28.9 30 25 35 30 10 10 8 10 RFCX48DP RFCX60DP 6HK16502025 j 46.2 28.8 25.0 32.6 28.9 30 25 35 30 10 10 8 10 6HK16502525 1 57.7 35.0 31.3 39.8 36.1 35 35 40 40 8 8 8 8 1. MOP=Maximum Overcurrent Protection device.must be HACR type circuit breaker or time delay fuse. 2. Stated sizes are for 75'C,copper wire only. If wire other than non-plated,75 C ambient,copper wire is used,consult applicable tables of the NEC and local codes. 3. 1st Circuit includes the blower motor amps. ACCESSORIES TYPICAL APPLICATIONS Refer to Price Manual for specific model numbers. TXV Kits-TXV kits are available for"Flex-coil"applications and converting R22 to R410A or as a service replacement. All kits are bolt-on and require no brazing to install. Electric Heaters - 6HK models shown under electrical data include sequential operation and temperature dual limit switches for safe, efficient operation. Circuit breakers are pro- vided where shown. HORI70NTAi RIGHT LIMITATIONS These units must be wired and installed in accordance with all national and local safety codes. Voltage limits are as follows: Air Handier Voltage Normal Operating Voltage code Voltage Range, �HORIzoNrAl uEFr 208/230-1-60 06 187-253 1. Rated in accordance with ARI Standard 110.utilization range W. Airflow must be within the minimum and maximum limits approved for electric heat,evaporator coils and outdoor units. Johnson Controls Unitary Products 7 810765-UTG-A-0313 TYPICAL THERMOSTAT CONNECTIONS THERMOSTAT AIR AIR � HANDLER HEAT THERMOSTAT HANDLER R R LIMP R G G rn n CONDENSING C C UNIT C -"� •Xt II{ COOLING ONLY v 1NsiE C C LLED n JUMPER IT C AEOUTAED n AIR v V THERMOSTAT HANDLER R R OY Y SINGLE STAGE HEAT PUMP AND ELECTRIC HEAT ( 10 KW AND BELOW) C CONDENSING UNIT C THERMOSTAT XAN Al LEA NEAT R rvZ �V1 ' R R PUMP COOLING WITH ELECTRIC HEAT n ( 10 KW AND BELOW) G G yll r"T Illff AIR THERMOS7Ar HANDLER;-- w _ AN E I E L o INSTALLED R IF JUMPER W - UMPER(p BaN n n v C � CONUNNTING O C I t ><1 �Y1 �V1 SINGLE STAGE HEAT PUMP AND COOLING WITH ELECTRIC HEAT ELECTRIC HEAT ( 13 KW AND ABOVE) ( 13 KW AND ABOVE) F 1 S Hf3 EL Ell NEI LS g 9_ - cr L ■f? rL t■ Bi [a tE0 / INI tNl D[LAT EODIPMEtT RED WHY P 6■M■B LU BtuI►R O■.0. ■ SEO? " I " Pat L? I ■ 3 x z z REDINEI Sf01 IILK LU NNl U ? Btu rrot■ER tC pT�a Lt LI to1■N 6HK16501506 HEAT BIT SHM TO CHANGE THE QUANTITY OF HEAT DURING HEAT PUMP DEFROST CYCLE(i; REVERSE THE BROWN AND WHITE WIRE CONNECTIONS ON THE SEOUENCERS IN THE HEATER KIT. ? THE PURPLE WIRE MUST BE MOVED FROM •1 ON SEOUENCER I TO $3 ON SEOUENCER 2 8 Johnson Controls Unitary Products 810765-UTG-A-0313 AIR FLOW DATA(CFM)1 Models Blower External Static Pressure(in.wc.) Motor Speed 0.10 0.20 0.30 0.40 0.50 0.60 0.70 208 Volt High 1024 1000 970 930 860 810 NA RFCX18BP08MP21 Medium 756 731 700 670 620 550 NA Low 557 531 495 445 375 315 195 High 995 970 935 900 925 795 645 RFCX24BP08MP21 Medium 820 810 780 745 695 545 485 Low 715 695 640 405 370 375 220 High 1380 1315 1245 1160 1075 990 885 RFCX30BP10MP21 Medium 1060 1040 1005 955 890 860 820 Low 1035 980 910 825 770 685 485 High 1410 1335 1270 1190 1110 990 820 RFCX36BP12MP21 Medium 1215 1170 1115 1050 935 850 740 Low 950 935 895 855 NA NA NA High 1800 1725 1645 1545 1360 1200 1050 RFCX42CP14MP21 Medium 1535 1480 1415 1280 1155 1010 870 Low 1225 1195 1095 1025 925 825 680 High 1890 1830 1755 1650 1565 1450 1285 RFCX48DP16MP21 Medium 1515 1480 1450 1380 1295 1115 985 Low 1170 1165 1140 1100 965 860 745 High 1911 1841 1757 1668 1564 1439 1233 RFCX60DP20MP21 Medium 1556 1507 1450 1388 1266 1246 989 Low 1211 1181 1 1151 1062 992 911 827 230 Volt High 1145 1100 1055 1005 930 845 725 RFCX18BP08MP21 Medium 755 750 725 665 605 485 435 Low 680 655 625 585 540 395 300 High 1305 1285 1225 1175 920 915 835 RFCX24BP08MP21 Medium 930 920 890 845 705 760 505 Low 735 730 700 670 545 470 NA High 1450 1380 1300 1215 1130 1030 910 RFCX30BP10MP21 Medium 1330 1280 1205 1135 1 1050 975 780 Low 1160 1120 1065 1005 930 825 635 High 1470 1390 1325 1245 1155 1045 880 RFCX36BP12MP21 Medium 1325 1265 1205 1125 1025 965 840 Low 1115 1075 1025 950 NA NA NA High 1750 1670 1570 1477 1260 1125 935 RFCX42CP14MP21 Medium 1590 1520 1435 1277 1150 1010 870 Low 1330 1280 1200 1083 980 850 NA High 2005 1940 1850 1755 1650 1530 1405 RFCX48DP16MP21 Medium 1705 1665 1605 1510 1425 1340 1185 Low 1355 1330 1300 1245 1170 990 980 High 2034 1955 1858 1753 1640 1522 1296 RFCX60DP20MP21 Medium 1733 1672 1609 1527 1431 1272 1220 Low 1388 1359 1 1313 1255 1133 1004 912 1. Air handler units have been tested to LIL 19951 CSA 22.2 standards up to 0.30"wc.external static pressure. Dry coil conditions only,tested without filters. For optimal performance,external static pressures of 0.2"to 0.5'are recommended. Applications above 0.6"are not recommended. Airflow data shown is from testing performed at 230V. AHE units use a X13 motor,and there is minimal variation of airflow at other distribution voltage values. The above data can be used for airflow at other distribution voltages. Johnson Controls Unitary Products 9 400038-UTG-B-0708 TECHNICAL DESCRIPTION The 13 SEER Series condensing unit is the outdoor part of a versatile system of air conditioning. It is designed to be cus- tom-matched with one of UPG's complete line of evaporator sections, with each serving a specific function. Matching Air GUIDE Handlers are available for upflow, downflow, or horizontal applications to provide a complete system. Electric Heaters are available, if required. Add-On coils are available for use with upflow, downflow, or horizontal furnaces and air han- dlers. SPLIT-SYSTEM WARRANTY AIR CONDITIONERS Single Phase Units: 5-year limited parts warranty. 13 SEER - R-22 5-year limited compressor warranty. MODELS: FEATURES GCGD12 THRU 60 QUALITY CONDENSER COILS -The coil is constructed of aluminum microchannel tubing and enhanced aluminum (1 THRU 5 NOMINAL TONS, 1 PHASE) fins for increased efficiency and corrosion protection. • PROTECTED COMPRESSOR -The compressor is inter- nally protected against high pressure and temperature. This is accomplished by the simultaneous operation of high pressure relief valve and a temperature sensor which protects the compressor if undesirable o p p Aerating condi- tions occur. A liquid line filter-drier further protects the compressor. DURABLE FINISH - The cabinet is made of pre-painted steel. The pre-treated galvanized steel provides a better 1 paint to steel bond,which resists corrosion and rust creep. Special primer formulas and matted-textured finish insure less fading when exposed to sunlight. LOWER INSTALLED COST - Installation time and costs are reduced easy power and control wiring connec- tions. Available in sweat connect models only. Thehe unit contains enough refrigerant for matching indoor coils and 15 feet of interconnecting piping. The small base dimen- sion means less space is required on the ground or roof. TOP DISCHARGE -The warm air from the top mounted fan is blown up away from the structure and any landscap- ing. This allows compact location on multi-unit applica- tions. • LOW OPERATING SOUND LEVEL -The upward air flow carries the normal operating noise away from the living \ area. The rigid top panel effectively isolates any motor ;.•, ' 't; �, \�"; sound. Isolator mounted compressor and the rippled fins ISS0 9001 of the condenser coil muffle the normal fan motor and r�c1 rart� o�o" „gay compressor operating sounds. us K13nagemeM$ystem LOW MAINTENANCE - Long life permanently lubricated motor-bearings need no annual servicing. LISTED • EASY SERVICE ACCESS-Fully exposed refrigerant con- nections, and a single panel covering the electrical con- trols make for easy servicing of the unit. • SECURED SERVICE VALVES - Secured re-usable ser- Due to continuous product improvement,specifications vice valves are provided on both the liquid and vapor are subject to change without notice. sweat connections for ease of evacuating and charging. • U.L.and C.U.L.listed-approved for outdoor application. Visit us on the web at www.york.com Certified in accordance with the Unitary Small Equipment cer- Additional rating information can be found at tification program,which is based on ARI Standard 210/240. www.ahridirectory.org FOR DISTRIBUTION USE ONLY-NOT TO BE USED AT POINT OF RETAIL SALE 400038-UTG-B-0708 Physical and Electrical Data MODEL GCGO12 GCGD18 GCG024 GCGD30 I GCGD36 GCGD42 GCGD48 GCGD60 S21S2 S21S2 S21S2 S21S2 S21S2 S21S2 S21S2 S21S2 Unit Supply Voltage 208-230V,1�.60Hz Normal Voltage Range 187 to 252 Minimum Circuit Ampac+ty 6.2 9.5 11.3 14.0 18.2 19.9 22.7 33.5 Max.Overcurrent Device Amps 2 15 15 15 20 30 30 35 50 Min,Overcurrent Device Amps b 15 15 15 15 20 20 25 35 Compressor Type Rotary Rotary Rotary Recip Recip Recip Recip Scroll Compressor Amps Rated Load 4.5 7.2 8.4 10.6 13A 14.7 17.0 25.6 Locked Rotor 26.0 40.0 47.0 61.0 78.0 78.0 86.0 150.0 Crankcase Heater No No No No No No No No Fan Motor Amps Rated Load 0.50 0.50 0.80 0.80 1.4 1.5 1.5 1.5 Fan Diameter Inches 18 18 18 18 18 22 22 22 Rated HP 1112 1112 1/8 1/8 1/4 1/4 1/4 1/4 Fan Motor Nominal RPM 1100 1100 1075 1075 1100 850 850 850 Nominal CFM 1350 1550 1850 1950 2400 3000 3000 3300 Face Area Sq.Ft. 8.1 9.7 9.7 11.3 12.1 16.5 16.5 19.75 Coil Rows Deep 1 1 1 1 1 1 1 1 Fin/Inches 23 23 23 23 23 23 23 23 Liquid Line Set OD(Field Installed) 3/8 3/8 318 3/8 3/8 3/8 3/8 3/8 Vapor Line Set OD(Field Installed) 5/8 5/8 3/4 3/4 3/4 7/8 7/8 1-1/8 Unit Charge(Lbs.-Oz.)4 3-2 3-0 3-13 3-7 3-15 4-2 4-5 5-4 Charge Per Foot,Oz. 0.66 0.66 0.68 0.68 0.68 0.70 0.70 0.76 Operating Weight Lbs. 96 110 130 150 160 175 176 200 1.Rated in accordance with ARI Standard 110,utilization range"A". 2.Dual element fuses or HACR circuit breaker.Maximum allowable overcurrent protection. 3.Dual element fuses or HACR circuit breaker.Minimum recommended overcurrent protection. 4.The Unit Charge is correct for the outdoor unit,matched indoor coil and 15 feet of refrigerant tubing.For tubing lengths other than 15 feet.add or subtract the amount of refrigerant,using the difference in length multiplied by the per foot value. All dimensions are in inches.They are subject to change without notice.Certified dimensions will be provided upon C, request. DIMENSIONS Unit Dimensions Refrigerant Connection J Model (Inches) Service Valve Size A' B C Liqu d Vapor 12 24 23-112 23-1/2 18 28 23-1/2 23-1/2 24 28 23-1/2 23-1/2 314" 30 32 23-1/2 23-1/2 3/8" 36 34 23-1/2 23-1/2 t 42 34 29 29 B �\ 7/8" 48 34 29 29 60 40 29 29 1-1/8- 1. Including Fan Guard. 2 Johnson Controls Unitary Products 400038-UTG-B-0708 Additional R-22 Charge/Orifice Size for Various Matched Systems Outdoor Unit GCGD12 GCGD18 GCGD24 GCGD30 GCGD36 GCGD48 GCGD60 S21S2 S21S2 S21S2 S21S2 S21S2 S21S2 S21S2 Required Orifice or TXV 1,2 0.041/2A 0.052/2A 0.059/0.061/2A 0.065/2A 0.073/2A 0.081/2CM 0.084/2C 0.096 12C Factory R-22 Charge,Ibs-oz 3-2 3-0 3-13 3-7 3-15 4-1- 4-5 5-4 Indoor C0113,4 Additional Charge,Oz FC/MC/PC/UC18A2A 0 0 - - - - - - FC/MC/PC/UC18B2A 0 0 - - - - - - FC/MC/PC/UC24A2A - 0 - FC/MC/PC/UC24B2A - 0 - - - - - - FC/MC/PC32A2A - - +3 +4 _ _ - _ FC/MC/PC35B2A - - +3 +4 - - - _ FC/MC/PC35C2A - - +3 +4 - - - - FC/MC/PC/UC36A2A - - 0 - - - - - FC/MC/PC/UC36B2A - - 0 FC/MC/PC/UC36C2A - - 0 - - - - - FC/MC/PC37A2A - - +7 +12 +4 FC/MC/PC43B2C - - - - - 0 FC/MC/PC43C2C - - - - - 0 _ _ FC/MC/PC/UC48C2C - - - - _ +5 +2 _ FC/MC/PC/UC48D2C - - - - - +5 +2 _ FC/MC62D2C - - - - - _ - 0 HC18A2A 0 0 - - - - HC30A2A - - 0 _ _ _ HC36132A - - +3 +4 - _ HC42C2C - - - +12 +4 0 AHP1862A 0 0 - - - - AHP24B2A - 0 - - AHP3062A - - +3 +4 _ AHP36C2A - - _ +12 +4 _ AHP42C2C - - - _ _ 0 AHP/SHP60D2C - - - _ _ _ 0 _ FC/MC/PC/UC18A3X 41 +0 52+0 - _ _ _ _ _ FC/MC/PC/UC18B3X 41 +0 52+0 - - - FC/MC/PC/UC24A3X - 52+2 - FC/MC/PC/UC24B3X - 52+2 - - - FC/MC/PC32A3X - - 61 +3 65+4 - - - - FC/MC/PC35B3X - - 61+3 65+4 - - - - FC/MC/PC35C3X - - 61+3 65+4 - FC/MC/PC/UC36A3X - - 59+0 - - FC/MC/PC/UC36B3X - - 59+0 FC/MC/PC/UC36C3X - - 59+0 - - - - - FC/MC/PC37A3X - - 61 +7 65+ 12 73+4 - - - FC/MC/PC43B3X - - 61 +7 65+ 12 73+4 81 +0 - - FC/MC/PC43C3X - - 61 +7 65+12 73+4 81 +0 - - FC/MC/PC/UC48C3X - - - _ 73+4 81 +5 84+2 _ FC/MC/PC/UC48D3X - - - - 73+4 81 +5 84+2 - FC/MC62D3X - - - _ _ _ _ 96+0 HC18A3X 41 +0 52+0 - - - _ _ _ HC30A3X - - 59+0 - - HC36B3X - - 61 +3 65+4 - - HC42C3X 1 - - 61 +7 65+ 12 73+4 81 +0 -For Notes See Page 4. Johnson Controls Unitary Products 3 400038-UTG-B-0708 Additional R-22 Charge/Orifice Size for Various Matched Systems (Continued) Outdoor Unit GCGD12 GCGD18 GCGD24 GCGD30 GCGD36 GCGD42 GCGD48 GCGD60 S21S2 S21S2 S21S2 S21S2 S21S2 S21S2 S21S2 S21S2 Required Orifice or TXV 1.2 0.041/2A 0.052/2A 0.059/0.061 12A 0.065/2A 0.073 12A 0.081/2C 0.08412C 0.096/2C Factory R-22 Charge,Ibs-oz 3-2 3-0 3-13 3-7 3-15 4-2 4-5 5-4 Indoor Coi13 4 Additional Charge,Oz AHP18B3X 41 +0 52+0 — — — — — — AHP24B3X — 52+0 — — — — — — AHP30B3X — — 61 +3 65+4 — — — — AHP36C3X — — — — 73+4 — — — AHP42C3X — — — — 73+4 81 +0 — — AHP/SHP60D3X — — — — — — 84+0 F4FP024 — — 52+0 — — — — — — SeeCautionbebw — 2A+0 — — — — — — F4FP036 See autlon ebw — 61 +1 2A+2 — — — — — F4FP040 ee Caution — — 65+0 — — — — 2A+0 — — — — F5FP048 rn auhon — — — — 73+0 81 +5 84+2 - - — — — 2A+0 2C+5 2C+2 - - — — — — —F5FP060 84+0 — See Cauuonbelow — — — ZC+0 _ FOOTNOTES: 1. For applications requiring a TXV use 1TVM series kit. 2.Approved orifice shipped with outdoor unit. 3.Systems matched with furnace or air handlers not equipped with blower-off delays may require blower Time Delay Kit 2FD06700224. 4.PC coils cannot be used in downflow or horizontal applications.FC coils cannot be used in horizontal applications. PROCEDURES: 1.Unit factory charge listed on the unit nameplate includes refrigerant for the condenser,the smallest evaporator and 15 feet of inter- connecting line tubing. 2.Verify the TXV or orifice and additional charge required for specific evaporator coil in the system using the above table. 3.Additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in Physical and Electrical Data Table. 4.For TXV match charge weight needs to be weighed in for specififc coil match and lineset length. 5.Permanently mark the unit nameplate with the total system charge.Total System Charge=Base Charge(as shipped)+adder for evaporator+adder for line set. IMPORTANT ModMrequireits for TXV matches.Models with"H"on the end of the model number have factory installed start kits. For models without an"H"refer to tech guide for kit number reference. A CAUTION F'FP Air Handlers come with a factory installed R-22 TXV. Please note that some models may take a different TXV then what is factory installed. fhe proper TXV must be installed for system reliability and performance.Also note. TXV must be removed for orifice match. 4 Johnson Controls Unitary Products 400038-UTG-B-0708 COOLING CAPACITY-With Air Handler Coils UNIT AIR HANDLER COIL COOLING MODEL MODEL W MODEL' RATED NET MBH SEER EER CFM TOTAL SENS. 13 SEER AC WITH MA GCGD18S21S2 MA08B 17 FC/MC18B 600 18.0 12.6 13.00 11.00 MA08B 17 FC/MC2413 600 18.0 12.6 13.00 11.00 MA08B 17 FC/MC35B 800 24.0 17.2 13.00 11.00 GCGD24S21S2 MA08B 17 FC/MC36B 800 24.0 17.2 13.00 11.00 MA08B 17 FC/MC43B 800 24.0 17.2 13.00 11.00 GCGD30S21S2 MA126 17 FC/MC35B 1000 29.0 21.2 13.00 11.00 MA12B 17 FC/MC43B 1000 29.0 21.2 13.00 11.00 GCGD36S21S2 MA12B 17 FC/MC4313 1200 35.0 24.4 13.00 11.00 MA14D 24 FC/MC48D 12n0 35.0 24.4 13.00 11.00 MA16C 21 FC/MC43C 1400 42.0 29.4 13.00 11.00 GCGD42S21S2 MA14D 24 FC/MC48D 1400 42.0 29.4 13.00 11.00 MA16C 21 FC/MC48C 1400 42.0 29.4 13.00 11.00 GCGD48S21S2 MA16C 21 FC/MC48C 1600 46.0 32.6 13.00 11.00 MA20D 24 FC/MC48D 1600 46.0 32.6 13.00 11.00 GCGD60S21S2 MA20D 24 FC/MC62D 1800 54.0 41.5 13.00 11.00 13 SEER AC WITH AHP I SHP/F*FP GCGD12S21S2 AHP18 17 - 450 12.0 8.9 13.00 11.00 AHP18 17 - 650 18.0 12.6 13.00 11.00 GCGD18S21S2 AHP24 17 - 650 18.0 12.6 13.00 11.00 F4FP024 18 - 600 18.0 12.6 1300 11.00 GCGD24S21S2 AHP30 17 - 795 24.0 17.3 13.00 11.00 F4FP036 21.5 - 860 24.0 17.3 13.00 11.00 AHP30 17 - 1015 29.0 21.2 13.00 11.00 GCGD30S21S2 AHP36 21 - 1015 29.0 21.2 13.00 11.00 F4FP040 21.5 - 1000 29.0 21.2 13.00 11.00 GCGD36S21S2 AHP36 21 - 1235 35.0 24.4 13.00 11.00 F5FP048 24 - 1235 35.0 24.4 13.00 11.00 GCGD42S21S2 AHP42 21 - 1485 42.0 29.4 13.00 11.00 F51FP048 24 - 1455 42.0 29.4 13.00 11.00 AHP/SHP60 24 - 1600 46.0 33.0 13.00 11.00 GCGD48S21S2 F5FP048 24 - 1690 46.0 33.0 13.00 11.00 F5FP060 24 - 1680 46.0 33.0 13.00 11.00 Rated in accordance with DOE test procedures(Federal Register 12-27-79 and 3-18-88)and ARI Standards 210. Coding MBH based on 80'F entering air temperature,50%RH,and rated air now. EER(Energy Efficiency Ratio)is the total cooling output in BTU's at 95"F outdoor ambient divided by the total electric power in watt-hours at those conditions. SEER(Seasonal Energy Efficiency Ratio)is the total cooling output in BTU's during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period. 1. MC coils available with a factory installed horizontal drain pan.See price pages for specific model number. -=Not applicable. Johnson Controls Unitary Products 5 400038-UTG-B-0708 COOLING CAPACITY -Upflow, Downflow& Horizontal Furnaces and Coils FURNACE" COOLING UNIT MODEL CFM RANGE COIL RATED NET MBH (Min.-max.) W MODEL CFM TOTAL SENS. SEER' EER 450-750 14,17 FC/MC/PC18 450 12.0 9.1 13.00 11.00 GCGD12S21 S2 450-750 14 HC18 450 12.0 9.1 13.00 11.00 450-750 14,17 UC18 450 12.0 9.1 13.00 11.00 450-750 14,17 FC/MC/PC18 600 18.0 12.6 13.00 11.00 450-750 14,17 FC/MC/PC24 600 18.0 12.6 13.00 11.00 GCGD18S21S2 450-750 14 HC18 600 18.0 12.6 13.00 11.00 450-750 14,17 UC18 600 18.0 12,6 13.00 11.00 450-750 14,17 UC24 600 18.0 12.6 13.00 11.00 600-1000 14 FC/MC/PC32 800 24.0 17.2 13.00 11.00 600-1000 17,21 FC/MC/PC35 800 24.0 17.2 13.00 11.00 600-1000 14,17,21 FC/MC/PC36 800 24.0 17.2 13.00 11.00 600-1000 14 FC/MC/PC37 800 24.0 17.2 13.00 11.00 GCGD24S21 S2 600-1000 17,21 FC/MC/PC43 800 24.0 17.2 13.00 11.00 600-1000 14 HC30 800 24.0 17.2 13.00 11.00 600-1000 17 HC36 800 24.0 17.2 13.00 11.00 600-1000 21 HC42 800 24.0 17.2 13.00 11.00 600-1000 14,17,21 UC36 800 24.0 17.2 13.00 11.00 800-1200 14 FC/MC/PC32 1000 29.0 21.2 13.00 11.00 800-1200 17,21 FC/MC/PC35 1000 29.0 21.2 13.00 11.00 GCGD30S21 S2 800-1200 14 FC/MC/PC37 1000 29.0 21.2 13.00 11.00 800-1200 17,21 FC/MC/PC43 1000 29.0 21.2 13.00 11.00 800-1200 17 HC36 1000 29.0 21.2 13.00 11.00 800-1200 21 HC42 1000 29.0 21.2 13.00 11.00 1000-1400 14 FC/MC/PC37 1200 35.0 24.4 13.00 11.00 1000-1400 17,21 FC/MC/PC43 1200 35.0 24.4 13.00 11.00 GCGD36S21S2 1000-1400 21,24 FC/MC/PC48 1200 35.0 24.4 13.00 11.00 1000-1400 21 HC42 1200 35.0 24.4 13.00 11.00 1000-1400 21,24 UC48 1200 35.0 24.4 13.00 11.00 1200-1600 17,21 FC/MC/PC43 1400 42.0 29.4 13.00 11.00 GCGD42S21 S2 1200-1600 21,24 FC/MC/PC48 1400 42.0 29.4 13.00 11.00 1200-1600 21 HC42 1400 42.0 29.4 13.00 11.00 1200-1600 21.24 UC48 1400 42.0 29.4 13.00 11.00 GCGD48S21S2 1400-1800 21,24 FC/MC/PC48 1550 46.0 32.6 13.00 11.00 1400-1800 21,24 UC48 1550 46.0 32.6 13.00 11.00 GCGD60S21 S2 1600-2000 24 FC/MC62 2000 55.0 41.0 13.00 11.00 1. Requires a 2FDO6700224 Blower Time Delay unless a standard furnace is equipped with one. "Refer to Quick Selection Chart for specific furnace match-up. 6 Johnson Controls Unitary Products 400038-UTG-B-0708 CONDENSER ONLY DATA SUCT.TIP @ COMPR AIR TEMP ON CONDENSER MODEL 75"F 95°F 115°F Temp. PSIG MBH KW MBH KW MBH KW GCGD12S21S2 40 68.6 11.81 0.73 8.15 0.85 5.29 1.01 SH 11 /SC 13 @ 45 76.1 12.65 0.73 10.15 0.86 7.21 1.02 95 OD Temp 50 84.1 13.55 0.74 12.29 0.87 9.26 1.04 GCGD18S21S2 40 68.6 17.53 1.07 15.03 1.29 11.98 1.57 SH 11/SC 10 @ 45 76.1 18.63 1.07 17.25 1.30 14.07 1,59 95 OD Temp 50 84.1 19.80 1.08 19.61 1.31 16.30 1.61 GCGD24S21S2 40 68.6 22.88 1.42 19.07 1.70 13.99 2.02 SH 10/SC 12 @ 45 76.1 24.93 1.44 22,25 1.72 17.25 2.07 95 OD Temp 50 84.1 27.12 1.47 25.63 1.75 20.72 2.12 GCGD30S21S2 40 68.6 28.77 1.75 23.85 2.01 17.06 2.21 SH 12/SC 10 @ 45 76.1 30.28 1.80 26.56 2.07 19.76 2.31 95 OD Temp 50 84.1 31.89 1.86 29.45 2.13 22.64 2.40 GCGD36S21S2 40 68.6 31.46 2.16 18.41 2.37 13.42 2.78 SH 10/SC 11 @ 45 76.1 36.54 2.20 25.84 2.47 18.88 2.85 95 OD Temp 50 84.1 41.95 2.24 33.77 2.58 24.71 2.91 GCGD42S21S2 40 68.6 40.44 2.46 28.86 2.83 21.78 3.21 SH 10/SC 9 @ 45 76.1 45.28 2.52 36.10 2.91 27.55 3.30 95 OD Temp 50 84.1 50.44 2.59 43.82 3.00 33.70 3.41 GCGD48S21S2 40 68.6 42.04 2.70 26.14 3.03 21.19 3.49 SH 10/SC 12 @ 45 76.1 46.86 2.77 35.10 3.16 27.59 3.60 95 OD Temp 50 84.1 52.00 2.85 44.65 3.30 34.43 3.73 GCGD60S21S2 40 68.6 52.76 3.40 46.38 4.04 36.26 5.08 SH 10/SC 9 @ 45 76.1 j 59.98 3.41 53.35 4.14 42.46 5.15 95 OD Temp 50 84.1 67.69 3.41 60.79 4.25 49.07 5.22 ACCESSORIES ROOM THERMOSTATS - A wide selection of compatible Refer to Price Manual for specific model numbers. thermosets are available to provide optimum performance HARD START KIT - Required when using TXV indoor coil. and features for any installation. Also, provides increased starting torque for areas with low 1H/1C, manual changeover electronic non-programmable voltage. thermostat. 1 H/1 C. auto/manual changeover, electronic programmable, Model Source 1 Kit numbers deluxe 7-day,thermostat. 12 S1-2SA067086D6 1H11C, auto/manual changeover, electronic programmable. 18 S1-2SA06708606 ' For the most current accessory information. refer to the 24 S1-2SA06708706 price book or consult factory. 30 S1-2SA06705906 36 31-2SA06708106 SOUND POWER RATINGS" 42 S1-2SA06708106 UNIT MODEL (dBA) 48 S1-2SA06708806 12 72 18 75 OFF CYCLE TIMER DELAY- Provides a 5-minute off cycle 24 76 to prevent rapid recycling of the compressor. 30 75 36 76 42 75 48 76 60 78 Rated in accordance with ARI 270-95 Standards. Johnson Controls Unitary Products 7 400038-UTG-B-0708 TYPICAL INSTALLATION MINIMUM 18'SERVICE 60'OVERHEAD ACCE CLEARCE THE RMOSTAT CLFARANCF ON ONESS S AN IDE WEATHERPROOF DISCONNECT SWITCH NEC CLASS 1 WIRING 6"CLEARANCE TO FURNACE OR AROUND PERIMETER _ -' AIR HANDLER �. TERMINAL BLOCK NEC CLASS 2 WIRING TO INDOOR COIL r NOTE: ALL OUTDOOR WIRING CONTROL MUST BE WEATHERPROOF. ACCESS SEAL OPENING(S)WITH PANEL PERMAGUM OR EQUIVALENT TYPICAL FIELD WIRING ALL FELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE(NEC) AND/OR LOCAL CODES POWER WIRING 24 VOLT C - - - POWER WIRING CONTROL WIRING 208/230-1-60 MINIMUM WIRE - - - - - • CONTROL WIRING (NEC CLASS 2) FACTORY WIRING i i I FURNACE OR AIR HANDLER TERMINAL BLOCK C Y R '; G; 'W` `' 1 I / 1 I I 1 •TERMINAL W IS ONLY CONTACTOR � I NTQH UIRED HEAT.ON SYSTEMS TERMINALS I I LUG COIL Y CONDENSING UNIT - J ROOM THERMOSTAT ALL OUTDOOR WIRING MUST BE WEATHERPROOF. USE COPPER CONDUCTORS ONLY. 8 Johnson Controls Unitary Products 400038-UTG-B-0708 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. GCGD42S21S2 INDOOR COIL MODEL NO. FC/MCIPC43 CONDENSING IDCFM 1200 1400 1600 ENTERING AIR ID DB ff) 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 TEMPERATURE ID WB("F) 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72 T.C. 39.7 42.3 41.6 45.1 46.3 41.4 43.5 42.3 45.7 46.7 43.1 44.7 43.0 46.2 47.0 65 S.C. 38.2 34.5 28.8 27.9 21.2 39.3 36.8 30.2 29.0 21.5 40.4 39.0 31.6 30.0 21.9 KW 2.2 2.3 2.2 2.3 2.3 2.2 2.3 2.3 2.3 2.3 2.2 2.3 2.3 2.3 2.3 T.C. 38.1 40.6 39.7 43.7 45.1 140.1 42.0 40.5 44.4 45.5 42.0 43.4 41.3 45.2 45.9 75 S.C. 36.8 34.3 28.4 27.9 21.0 38.0 36.5 30.0 29.2 21.6 39.3 38.7 31.7 30.6 22.1 KW 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.6 T.C. 36.5 38.9 37.7 42.3 43.9 38.7 40.5 38.6 43.2 44.4 40.9 42.0 39.5 44.1 44.9 85 S.C. 35.4 34.1 27.9 27.8 20.8 36.8 36.3 29.8 29.5 21.6 38.2 38.5 31.7 31.2 22.4 KW 2.7 2.7 2.7 2.7 2.8 2.7 2.7 2.7 2.8 2.8 2.7 2.7 2.7 2.8 2.8 T.C. 35.0 1 37.2 135.8 40.9 42.7 37.4 39.0 1 36.8 42.0 43.3 39.8 40.7 37.8 43.1 143.8 95 S.C. 33.9 33.8 27.4 27.7 20.7 35.5 36.0 29.6 29.8 21.6 37.1 38.2 1 31.8 31.8 22.6 KW 2.9 2.9 2.9 3.0 3.1 2.9 2.9 2.9 3.0 3.1 3.0 3.0 3.0 3.0 3.1 T.C. 33.7 34.8 32.6 38.0 39.5 35.6 36.4 33.7 38.9 40.1 37.5 38.0 34.8 39.8 40.7 105 S.C. 31.9 31.9 26.1 26.5 19.4 33.2 33.7 28.2 28.5 20.6 34.6 35.5 30.3 30.6 21.7 KW 3.2 3.2 3.2 3.2 3.3 3.2 3.2 3.2 3.2 3.3 3.2 3.2 3.2 3.3 3.3 T.C. 32.4 32.5 29.5 35.1 36.5 33.8 33.9 30.7 35.9 37.1 35.1 35.4 31.8 36.6 37.7 115 S.C. 29.9 130.0 124.8 25.3 118.2 131.0 31.5 26.8 27.3 19.5 32.1 33.0 128.8 129.4 20.8 KW 3.4 3.4 3.4 3.5 3.6 3.4 3.4 3.4 3.5 3.6 3.5 3.5 3.4 3.5 3.6 T.C. 31.1 30.1 26.4 32.3 33.4 32.0 31.4 27.6 32.81 34.01 32.8 32.8 28.91 33.4 34.7 125 S.C. 27.9 28.1 23.5 24.1 17.0 28.8 29.2 25.4 26.1 18.5 29.7 30.4 27.41 28.2 20.0 KW 3.7 3.6 3.6 3.7 3.8 3.7 3.7 3.6 3.7 1 3.8 1 3.7 3.7 3.7 3.7 3.9 NOTE:ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections. NOTE:For dry bulb temperatures different than those listed(between 73-87 F).sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the fisted temperature. Air Handler Coil T.C. S.C. KW FC/MC/PClUC48 1.00 1.00 1.00 HC42 1.00 1.00 1.00 AHP42 - 1.00 1.00 1.00 F5FP048 - 1.00 1.00 1.00 MA16C FC/MC43C 1.00 1.00 1.00 MA14D FC/MC48D 1.00 1.00 1.00 MA16C FC/MC48C 1.00 1.00 1.00 14 Johnson Controls Unitary Products /ir xr•7•w'r2y, '!'.wr r r 1 .!•1'! r ti.. 4} 'Y t Y'�i 4t4 .- - 'h 7 t , A r �'�••� A':NN.�,,�i3 r,�v'h Ar y�"y" `�Qf�t� w Wy �'�,y. �A 1r t A T/ � �� v Ai �f � vy�+� �y �• ��'��rrr� 6' titif rrp... Q :.,;:� �t��'}¢s^� �J -., '�rrf a+' tif�`v t O• ,�'`�4 U a;}},4*0&°s r! ,��. r J• lti�n:. r � �N" /,?;,'. ,,,, �fir, -. v �'•. v 1t d.f•\.1r .131'" ! �• '. �t iat '�'t�1 '_ ct.vf � •� .r+m. `. '�', .. �v�+};, �/�'�j';•1. '1�'"e4i 1 •i��+�11, ;iig�'v3Frtl1 •1�►1'1�11�1';lli!�v��1�! '11'f'/i+�, ���4s.$itlJ,':��i11�f�1i�/ 3i�z'sew :�.5 ! .,-s,,,,"���tr '+�y)i+'��� + i1d " �1'►i'i';, �ti�,,�F7� `;Ih'11,1, ;_:� r �,f)/�, . 111/ ,1� 1 _I�.O�f.:,...-:�_.. %�i�I► ;ttZ lam. ;�� T�aT_t +'tea s' yi�11.�.41._ �c`-%s�i �►i�.xf f..:L. '�} -_. a�i+.��r_.�... c=i s. f(0)11 S'ACV ^yam jL > r.... Q. N '=7 a ° LLJ to : O N it ' a : acu �- 6m a ) r� H °c j O � Q O •y ction Z U ` a �Q`Ote W i O Z 2 w �. LLJ Z X ._� •� 6. o 0 x o •J� �' 4 Lr�r d..i O Q '• �~�; .� Mil _ v�i `�_;• ; Q cu LO • I )t R R � a � o • r U> 1r_ ICE I* a • :i 1<l0) :.^I+Im1�•- R , '- , 1 1+ ' 11 11�s. '-� 1 �1 s� yir s !•�� .���/�f111 � `-��°9��t';I►N't gg ry� �/I/fc►J��'F9fs�! ¢ z,�ffN, �]pp t e�11)i�J aj 1/1)i 1� ♦R A � `�•1�i' �1��PA1�1 G���J i�SPAi��� ♦• iS�t4A��Ir, •♦ `t�7yA, ♦• A tO A � �p{�A - A $'�l^���"'• :J��t '\ 'v�` �. ram'. �/�` .�. �•. �6��5'n'� "`'v''�' v`r� �•�v-'• ,aco CERTIFICATE OF LIABILITY INSURANCE DAT�IMM�,YYYYI � 12/152022 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsements . PRODUCER CONTACT NAME FEDERATED MUTUAL INSURANCE COMPANY ' NNo Ext:888-333-4949CONTACTCENT Fnic No:507 44Cr4664 HOME OFFICE: P.O.BOX 328 A C OWATONNA, MN 55060 rADMAIL DRESS:CLIENTCONTACTCENTER DFEDINS.COM INSURER(S)AFFORDING COVERAGE _ NAIC# INSURER A:FEDERATED MUTUAL INSURANCE COMPANY 13935 INSURED 286-468-4 INSURER B:FEDERATED RESERVE INSURANCE COMPANY 16024 ARCTIC MECHANICAL INCORPORATED INSURER C: 460 N MAIN ST — -- - - - -- -- PORT CHESTER, NY 10573-3310 INSURER D: INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER:90 REVISION NUMBER:0 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN.THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS,EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE DL SUBR POLICY NUMBER POLICY EFF POLICY EXP LIMITS LTR INSR WVD MMI IYYYY MMIDDIYYY X j COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $1,000,000 IX AGE TO RENTDCLAIMS-MADE L_J OCCUR REMISES Ea occurrence $100,� MED EXP(Any am person) EXCLUDED A N N 9907993 01/18/2023 01/18/2024 PERSONAL&ADV INJURY $1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $2,000,000 X POLICY O- ❑LOC PRODUCTS-COMPIOP AGO $2,000,000 OTHER. AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $1 O�O� a accident X ANY AAJTO BODILY INJURY(Per person) SCHEDULED -- A OWNED AUTOS ONLY AUTOS N N 9907993 01/18/2023 01/18/2024 BODILY INJURY(Per accident) HIRED AUTOS ONLY NON-OWNED PROPERTY DAMAGE AUTOS ONLY (Per acci X UMBRELLA LIAB X OCCUR EACH OCCURRENCE $5,000,000 A EXCESS LIAB CLAIMS-MADE N N 9907994 01/18/2023 01/18/2024 AGGREGATE $5,000,000 DED I X I RETENTION$10.000 WORKERS COMPENSATION OTH- AND EMPLOYERS'LIABILITY Y/N X PER STATUTE ER ANY PROPRIETOR/PARTNER/EXECUTIVE E.L.EACH ACCIDENT $1 OOO OOO B OFFICER/MEMBER EXCLUDED? N/A N 9298530 01/18/2023 01/18/2024 (Manciatory in NH) E.L.DISEASE-EA EMPLOYEE $1 000 000 If yes,describe under DESCRIPTION OF OPERATIONS below E.L DISEASE-POLICY LIMIT $1 000 000 DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached it more space is required) CERTIFICATE HOLDER CANCELLATION 286-4684 90 0 VILLAGE OF RYE BROOK SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 938 KING ST THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN RYE BROOK, NY 10573-1226 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE © 1988-2015 ACORD CORPORATION.All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD YORK Workers' CERTIFICATE OF STATE Compensation NYS WORKERS' COMPENSATION INSURANCE COVERAGE Board 1a.Legal Name&Address of Insured(use street address only) 1b. Business Telephone Number of Insured ARCTIC MECHANICAL INCORPORATED 914-934-8301 460 N MAIN ST PORT CHESTER,NY 10573-3310 1 c NYS Unemployment Insurance Employer Registration Number of Insured Work Location of Insured(Only required if coverage is specifically limited to 1 d Federal Employer Identification Number of Insured or Social Security certain locations in New York State,i.e.,a Wrap-Up Policy) Number 06-1596446 2.Name and Address of Entity Requesting Proof of Coverage 3a. Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) Federated Reserve Insurance Company Village of Rye Brook #90 3b Policy Number of Entity Listed in Box"la" 9298530 938 King St Rye Brook.NY 10573-1226 3c.Policy effective period 01/18/2023 to 01/18/2024 3d The Proprietor,Partners or Executive Officers are 0 included.(Only check box if all partners/officers included) all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box°3"insures the business referenced above in box 1 a"for workers' compensation under the New York State Workers'Compensation Law. (To use this form, New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate (These notices may be sent by regular mail.)Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent,or until the policy expiration date listed in box"3c",whichever is earlier. This certificate is issued as a matter of information only and confers no rights upon the certificate holder. This certificate does not amend, extend or alter the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect Please Note: Upon cancellation of the workers'compensation policy indicated on this form,if the business continues to be named on a permit, license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury, I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Jean Newkirk (Print name of authorized representative or licensed agent of insurance carrier) Approved by' (Signature) (bate) Title: AUTHORIZED REPRESENTATIVE Telephone Number of authorized representative or licensed agent of insurance carrier: 888-333-4949 Please Note: Only insurance carriers and their licensed agents are authorized to issue Form C-105.2. Insurance brokers are NOT authorized to issue it. C-105.2 (9-17) www.wcb.ny.gov