No preview available
HomeMy WebLinkAboutEP23-136 t , N ■ PLO00 � y w w P0 •r. 3 ti CIO ­Q W a o D x O � C� d ., O w l o Z Q Q R+ oo � z a -� O p qC4 CA o i ^ NrA < 00 E r�C ^ U v� a. O � � `o w Z z O °M° m z a CA CA Ln� a I, V °� C�7 a o w M ° U U oC z E w O !A w V g o x w z CF x i c U � Q w � Z � W = v<i • �E [3RCw ECENE BUIL \MENT RVIL E OF RYE OK MAY 2 3 1023 .1 938 KrN , ET RYE B NY 10573 VILLAGE OF RYE BROOK wwwa'yebrook.org BUILDING DEPARTMENT ELECTRICAL PERMIT APPLICATION Westchester County Master Electricians License Required FOR OFFICE USE ONLY BP#: EP#: d r /36 Approval Date: �- Permit Fee: $ ��695ai IF roval Si nature: I Other: ***************** **** ***************** * ** Appg ************************************************** Application dated 0 5 is hereby made to the Building Inspector of the Village of Rye Brook NY, for the issuance of a Permit to install and/or remove electrical equipment,wiring, fixtures, or to perform other high or low voltage electrical work as per the detailed statement described below. By signing this document, the applicant & property owner agree that all electrical work performed will be in conformance with all applicable Federal, State,County and Local Codes. /_ 1.Address: ! 4P E ti R�E 62°CK SBL: I4/•�7 I�� Zone: 2.Property Owner: W l 1 ro E /QER�-�-/ Address: d4 �&�E /19/4)6 E )04 A'2 A Phone#: n Cell#: email: 3.Master Electrician/Licensed Installer: LA4 ✓/A R a--t-2 6-'kl Address- O N ,A DO O o�/f e email: s4ix-s SeQ r'loye .� Lic.#: Phone#: 92?i22odCell#: '� � WZOL) Company Name: ..SL_"S 0 4Zlt- aS-5, 84 Address: A AWO Al 7-64 x-14- 4.Proposed Electrical Work/Fixture Count: .(,� >C—✓/ C a<S 20A.1 A1Ce7rd rD ay tLD o��-J /14-14 7 &1. SetoXcS ! Ac.Z -T q 4-t—S72Q 770 Al .2- s o B & 5.3`d Party Electrical Inspection Agency: v� S6;oe✓1� STATE OF NEW YORK,COUNTY OF WESTCHESTER ) as: d�l/ ilY sworn,deposes and states that he/she is the applicant above named,and does further (p ut name of individual signing as the a ica state that(s)he is the � 0` ��� for the legal owner and is duly authorized to make and file this application. (Master Electrician/Licensed Installer) The undersigned further states that all statements contained herein are true to the best of his/her knowledge and belief,and that any work performed,or use conducted at the above captioned property will be in conformance with the details as set forth and contained in this application and in any accompanying approved plans and specifications,as well as in accordance with the New York State Uniform Fire Prevention&Building Code,the Code of the Village of Rye Brook and all other applicable laws,ordinances,and regulations. Sworn to before me this Sworn to before me this 93 day of 20 day, 4 0 cam-- Signature of Property Owner Signature o �fi� Print Name of Property Owner n ame of Applicant Notary Public NOt§MR11WkJLL0 Notary Public,State of New York No.01ME6160063 Qualified In Westchester County-Z 7 Commission Expires January 291 20-_ 1 3/3/2023 • STATEWIDE INSPECTION 1:1 Main Street,Fishkill, NY 12524 1 email:office@swisny.com SWIS JOBAPPLICATION84 12.7224 fax914.219.1062 • • • Office Use Elect.Permit# Date Bldg Permit# Utility ID# Final Certificate# City/Village Zip , - Township County Address \ Cross Street Section Block dot S ��� C" Owner Name/Address(If different than above) Contact Number Basement ❑1st FI. ❑2nd FI. 3rd FI. More Than 3 FI. Garage Attic Outside Residential Commercial Receptacles Special Recept GFCI AFCI Switches Dimmers Smoke Alarms Carbon Monox Hood Trash Compact Amt Amps Range(s) Cooktop(s) Oven(s) Dishwashers Refrigerator Disposal Microwave Warm Draw Incandescent Fluorescent SERVICE Amperage Voltage 1P 3P #Meters #Disconnect Underground New Reconnect ❑Overhead ❑Change Visual Re-Inspection Safety Re-Inspection Re-Inspection Additional Information N��+-� c�� �- 1���1�C�E.� LC�►J t..l l:L'7 t� �U I '1 S?t V[� S� `__~�',�, ID MAY 2 3 2023 VILLAGE OF RYE BROOK BUILDING DEPARTMENT This application is valid for one(1)year from the date received by SMS.This application is intended to cover the above listed items to be Inspected,if at any time of inspection additional items have been installed,you are audwrized to make the inspection and adjust the fee for the additional items inspected.The applicant declares that there is no open applications for the above address wit h any or her inspect ion company The applicant,owner or authorized agent agrees to all the above terms and conditions as set forth for the application. Inspector Date Finalized Inspector# Company Name �- Date , `- Signature _ Address - _ City/State Zip Code i License# Phone# Arcuri Alarm Systems, Inc. PROPOSAL 81 Sterling Ave PROPOSAL No. 4855 Harrison, NY 10528 Proposal Date 10/13122 914-381-5747 Fax Salesperson GUY License# 12000042641 Site Contact FRANCISCO CANO Telephone 732-485-7388 Fax Number Prepared For Job Site FOUNDERS TABLE RESTAURANT GROUP CHOP'T 800 WESTCHESTER AVE. 116 SOUTH RIDGE STREET RYE BROOK, NY 10573 RYE BROOK, NY 10573 Page 1 - — -- Overview — - FIRE ALARM PROPOSAL ALL NEW DEVICES WILL BE CONNECTED TO MAIN BUILDING FIRE ALARM SYSTEM. 7-PHOTOELECTRIC SMOKE DETECTOR. 1-HEAT DETECTOR 2-MANUAL FIRE PULL STATIONS. 2-CARBON MONOXIDE DETECTORS. 4-STROBElHORNS. 2-STROBE LITES. TOTAL COST.....5150.00 IF PLANS ARE REQUIRED ADD ADDITIONAL 2500.00 81 Sterling Ave Harrison NY 10528 Tel914-381-5747 Fax guya@arcurialarms.com hvw.arcunalarms.com Arcuri Alarm Systems, Inc. PROPOSAL 81 Sterling Ave PROPOSAL No. 4855 Harrison, NY 10528 Proposal Date 10113122 914-381-5747 Fax SalesPerson GUY License# 12000042641 Site Contact FRANCISCO CANO Telephone 732-485-7388 Fax Number Prepared For Job Site FOUNDERS TABLE RESTAURANT GROUP CHOP`T 800 WESTCHESTER AVE. 116 SOUTH RIDGE STREET RYE BROOK, NY 10573 RYE BROOK, NY 10573 Page 2 Pricing We Propose Hereby to fumish this PROTECTION All material is guaranteed to be completed in SYSTEM including material and labor complete a workman like manner according to standard in accordance with above specifications for: practices. Any alteration or deviation from the Total Parts And Labor 5,150.00 above specifications involving extra cost will be done only upon written orders, and will Sales Tax 431.31 become an extra charge over and above the Total Job Price 5,581.31 estimate. Payment Schedule Initial Deposit 2,790.66 Second Payment 2,790.66 Third Payment I I [ This proposal may be withdrawn by us if not accepted within 90 Days INITIAL DEPOSIT IS DUE AT THE TIME OF ACCEPTANCE OF THIS PROPOSAL PLEASE SIGN BELOW AND RETURN YOUR PAYMENT TO OUR OFFICE. Signature (Title) Date Signed 81 Sterling Ave Harrison NY 10528 Tel914-381-5747 Fax guya@arcurialafms.com .w w.arcurialarms.com PROJECT: SEQUENCE OF OPERATION FIRE ALARM RISER NOTES FIRE ALARM GENERAL NOTES CHOPT (INTERNAL FIRE ALARM SYSTEM) MAIN SERVICE SWITCH 116 South Ridge St. 1 EACH FA RELAY SHALL HAVE MINIMUM OF THREE SETS OF 1.FOR LOCATIONS AND QUANTITIES OF DEVICES REFER TO FLOOR PLANS AND OPSOERVCREET SIDE FOR BUILDING Rye Brook,NY CONTACT 10A RATED 0 120V.(TYPICAL) RISER DIAGRAMS. WHERE THERE ARE DISCREPANCIES BETWEEN THE PLANS 2 ALL STROBES,&STROBE/HORNS SHALL BE FLUSH WALL AND RISER,THE GREATER QUANTITY SHALL BE USED. (AFTER METER) A. THE SYSTEM SHALL IDENTIFY ANY OFF NORMAL CONDITION AND LOG EACH MOUNTED FINISH BY ARCHITECT,OR AS APPROVED. 2.DEVICES AND CONNECTIONS SHOWN ARE FOR INFORMATION ONLY. IT IS THE FROM TO BLDG.LOADS CONDITION INTO THE SYSTEM DATABASE AS AN EVENT. RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO FIELD VERIFY THE FLOOR FUSES(TYP.) 1.THE SYSTEM SHALL AUTOMATICALLY DISPLAY ON THE CONTROL PANEL LIQUID 3 ALL DUCT SMOKE DETECTORS INSTALLED IN HUNG CEILING CONDITIONS PRIOR TO THE START OF ANY WORK. UTILITY CRYSTAL DISPLAY THE FIRST EVENT OF THE HIGHEST PRIORITY BY TYPE. AREA AND IN OUT OF SIGHT AREA SHALL HAVE REMOTELY M .� , F\f S N THE PRIORITIES AND TYPES SHALL BE ALARM,SUPERVISORY,TROUBLE,AND INSTALLED STATUS INDICATOR LAMPS.COORDINATE EXACT LOCATION WITH ARCHITECT AND GENERAL CONTRACTOR. 3.CONTRACTOR SHALL VERIFY ALL WIRING WITH FIRE ALARM VENDOR AND TO S.D.SYSTEM C.P.U. 309 Lexington Ave.,Ste.309 MONITOR. OBTAIN WIRING DIAGRAMS BEFORE PROCEEDING WITH THE START OF ANY g 2.THE SYSTEM SHALL HAVE A QUEUE OPERATION,AND SHALL NOT REQUIRE WORK. New York,NY 10017 EVENT ACKNOWLEDGMENT BY THE SYSTEM OPERATOR. THE SYSTEM SHALL 4 FOR WALL MOUNTED F.A.DEVICES PROVIDE 3/4"CONDUIT 2 1 2 687 3 0 5 0: hone HAVE A LABELED COLOR CODED INDICATOR FOR EACH TYPE OF EVENT; TERMINATED IN NEAREST ACCESSIBLE CEILING. 4.DO NOT SPLICE FIRE ALARM CONDUCTORS. P ALARM-RED,SUPERVISORY-YELLOW,TROUBLE-YELLOW,MONITOR- 212 687 3053:f a X YELLOW. WHEN AN UNSEEN EVENT EXISTS FOR A GIVEN TYPE,THE 5 COORDINATE WIRING DIAGRAM WITH FIRE ALARM VENDOR SHOP 5.FINAL CONNECTIONS ARE TO BE DONE BY ELECTRICAL CONTRACTOR UNDER THE GROUNDING SOLID NEUTRAL INDICATOR SHALL BE LIT. DRAWINGS,FOR STROBES MAXIMUM CURRENT PER ZONE SHALL SUPERVISION OF MANUFACTURER. PIPE CLAMP 3,FOR EACH EVENT,THE DISPLAY SHALL INCLUDE THE CURRENT TIME,THE NOT EXCEED 1.5A.ZONES FOR STROBES&STROBE/HORNS GROUND TO COLD WATER SERVICE TOTAL NUMBER OF EVENTS,THE TYPE OF EVENT,THE TIME THE EVENT AS PER FIRE ALARM VENDOR SHOP DRAWINGS,(TYPICAL) 6.PROVIDE FAN SHUT DOWN CAPABILITY FOR FANS WITH A RATING LARGER THAN OCCURRED AND UP TO A 42 CHARACTER CUSTOM USER DESCRIPTION. 2,000 CFM. SHUT DOWN SHALL BE ACCOMPLISHED BY ONE OR MORE 4.THE USER SHALL BE ABLE TO REVIEW EACH EVENT BY SIMPLY SELECTING 6 ALL FIRE ALARM WIRING SHALL BE TEFLON"RED". OUTPUT CONTROL POINTS FROM THE FIRE ALARM SYSTEM TO RELAYS FOR FROM STREET O TO BUILDING r SCROLLING KEYS(UP-DOWN)FOR EACH EVENT TYPE. WIRING INSTALLED IN NON ACCESSIBLE CEILING,EXPOSED BELOW 8' SHUTDOWN. PROVIDE CONTROL AND MONITORING FOR ALL RELAYS.PROVIDE DISTRIBUTION DISTRIBUTION FILE COPY 5.NEW ALARM,SUPERVISORY,OR TROUBLE EVENTS SHALL SOUND A SILENCING OR IN MECHANICAL ROOM AREA(NO CEILING)ROUTE IN CONDUIT. POWER,CONTROL RELAYS,MONITORING AND WIRING FOR ALL FIRE/SMOKE AUDIBLE SIGNAL AT THE CONTROL PANEL. DAMPERS, DAMPER MONITORING SHALL BE FROM AN END SWITCH ON THE - DAMPER VIA A RELAY. REFER TO HVAC PLANS AND SPECIFICATIONS FOR 7 THIS RISER DIAGRAM IS A SCHEMATIC REPRESENTATION OF REQUIRED FIRE MODE OPERATION OF ASSOCIATED DAMPERS AND FANS. B. OPERATION OF ANY MANUAL FIRE ALARM STATION OR ALARM ACTIVATION OF THE FIRE ALARM SYSTEM.REFER TO FLOOR PLANS FOR EXACT FIRE ALARM CONTROL PANEL ANY AREA SMOKE DETECT/SENSOR,DUCT SMOKE DETECT/SENSOR,AND QUANTITY OF DEVICES. 7.DUCT DETECTORS SHALL BE FURNISHED AND INSTALLED BY THE ELECTRICAL SPRINKLER WATERFLOW SWITCHES SHALL AUTOMATICALLY CONTRACTOR ALONG WITH FURNISHING OF THE SAMPLING TUBES, DUCTWORK MODIFICATIONS AND INSTALLATION OF SAMPLING TUBES SHALL BE BY THE ELECTRICAL SERVICE DETAIL 1,UPDATE THE CONTROL/DISPLAY AS DESCRIBED ABOVE(A.1.) BEACH FIRE ALARM INDICATING DEVICES CIRCUIT TO HAVE A MECHANICAL CONTRACTOR. FOR FANS RATED LARGER THAN 2,000 CFM N.T.S. / MAXIMUM OF 14 DEVICES PER CIRCUIT.CONTRACTOR TO PROVIDE DUCT DETECTOR IN SUPPLY DUCT;FOR FANS RATED LARGER THAN PERMIT* / SUPPLY REQUIRING NUMBER OF INDICATING CIRCUIT TO 15,000 CFM PROVIDE DUCT DETECTORS IN SUPPLY AND RETURN DUCTWORK. 2.SOUND A PULSING AUDIBLE SIGNAL AND FLASH THE GENERAL ALARM LED PROVIDE REDUNTANT CIRCUITING(A,B)SCHEME. SBL# INDICATOR AT THE FACP. PRESSING THE ALARM ACKNOWLEDGE KEY ON THE B.PROVIDE ALL REQUIRED EXPANSION PANELS,PC BOARDS,POWER SUPPLIES, NOTE: DATEAPPR 2023 FACP SHALL SILENCE THE AUDIBLE SIGNAL AND CONTINUOUSLY LIGHT THE BATTERIES,FUSE CUTOUTS AND BRANCH CIRCUITS,ETC, FOR A COMPLETE 1. ALL CONDUCTORS(INCLUDING SERVICE TAP) LED,DURING THE ALARM CONDITION. SUBSEQUENT ALARM CONDITIONS 9 PARTIAL RISER IS DIAGRAMMATIC AND FOR INTENT ONLY.PRIOR TO BID AND OPERATIONAL FIRE ALARM SYSTEM. MUST BE IN RIGID CONDUIT. SHALL RESOUND THE AUDIBLE SIGNAL AND AGAIN FLASH THE LED. EACH SUBMISSION COORDINATE WITH BUILDING FIRE ALARM VENDOR FOR THE -- -- ALARM CONDITION MUST BE INDIVIDUALLY ACKNOWLEDGED. FOLLOWING: 9.HORNS AND STROBES SHALL BE WIRED ON ALTERNATING A-B CIRCUITING IN 2. PROVIDE ENGRAVED LABELS FOR ALL EQUIPMENT. EUILOfNr.IN, • SCOPE OF WORK TO BE PERFORMED BY THE FIRE ALARM VENDOR ALL AREAS. 3.DISPLAY A GENERAL ALARM INDICATION AND SYSTEM STATUS SUMMARY AND THE ELECTRICAL CONTRACTOR. (NUMBERS OF ALARM,SUPERVISORY AND/OR TROUBLE CONDITIONS)ON THE • EXACT LOCATION OF EXISTING DGP PANEL,TERMINAL BOXES FACP ALPHANUMERIC,LIQUID CRYSTAL DISPLAY(LCD).THE LCD DISPLAY ETC. DWG LIST SINGLE TERMINAL SHALL AUTOMATICALLY DISPLAY THE DEVICE/CIRCUIT TYPE AND THE CUSTOM • SCOPE OF WORK TO BE PERFORMED WITHIN BASE BUILDING SYSTEM DUPLICATE DUPLICATE NOTCHED CLAMPING DUPLICATE 42-CHARACTER MESSAGE WITHOUT ANY OPERATOR INTERVENTION. AS REQUIRED TO ACCOMODATE ADDED DEVICES.NEW EXPANSION FA-100.00 FIRE ALARM SYMBOLS,NOTES,PLAN TERMINALS LEADS PLATE TERMINALS COUNTY LICENSED BOARDS,TERMINAL BOXES,STROBE POWER SUPPLY,REPROGRAMMING AND RISER DIAGRAM ELEOMCIAN 4.ENTER THE CUSTOM LABEL FOR THE DEVICE OR CIRCUIT REPORTING THE ETC).THE VENDORS COST OF THE UPGRADING SHALL BE INCLUDED IN CONTROL UNIT WDTOFILE ALARM CONDITION WITH THE TIME AND DATE OF ALARM ACTIVATION INTO THE BID PROPOSAL. FA-200.00 FIRE ALARM SPECIFICATIONS-1 INITIATING 0 R6QUI FACP HISTORICAL ALARM LOG FOR FUTURE RECALL/REVIEW. FA-201.00 FIRE ALARM SPECIFICATIONS-2 DEVICE p SPLICE CIRCUIT 5.SOUND AN AUDIBLE SIGNAL AT THE REMOTE ANNUNCIATOR PANEL. THE H� FA-203.00 FIRE ALARM SPECIFICATIONS-3 AUDIBLE SIGNAL MAY BE SILENCED DURING THE ALARM CONDITION. I I CIRCUIT WIRING ONE SPLICE LEAD CIRCUIT WIRING BENT CIRCUIT WIRING LOOPED SUBSEQUENT ALARM CONDITIONS SHALL RESOUND THE AUDIBLE SIGNAL. END OF LOOPED UNDER CONNECTED,OTHER BACK ON ITSELF AND UNDER TERMINAL.WIRE F FIRE ALARM SYMBOL LIST LINE ESISTOR ONE TERMINAL. TAPED AND NOT USED, SECURED IN ONE NOTCH. RUN NOT BROKEN. 6.VISUALLY ANNUNCIATE THE ALARM-INITIATING DEVICE VIA AN INDIVIDUAL OR u�}u "GROUP"ALARM INDICATOR. UI C FAC FIRE ALARM CONTROL PANEL u 7.DISPLAY A GENERAL ALARM INDICATION AND SYSTEM STATUS SUMMARY T� IN OUT IN OUT (NUMBERS OF ALARM,SUPERVISORY AND/OR TROUBLE CONDITIONS)ON E FFAP REMOTE ANNUNCIATOR THE REMOTE ANNUNCIATOR PANELS(S)ALPHANUMERIC,LIQUID CRYSTAL - --- IMPROPER METHODS-NOT TO BE USED DISPLAY(LED). THE LCD SHALL AUTOMATICALLY DISPLAY THE DEVICE TYPE --- A 0 MANUAL PULL STATION AND CUSTOM 42-CHARACTER DISPLAY WITHOUT OPERATOR INTERVENTION. A --- ACCEPTABLE METHODS-TO BE USED C� CARBON MONOXIDE DETECTOR END OF 8.SOUND THE APPROPRIATE TEMPORAL 3 ALARM CODE ON ALL HORNS --- SINGLE TERMINAL LINE THROUGHOUT THE BUILDING.ACTIVATION OF A SMOKE OR HEAT DETECTOR DUPLICATE DUPLICATE NOTCHED CLAMPING DUPLICATE RESISTOR SHALL ALSO CONTINUOUSLY SOUND THE SMOKE/HEAT ALARM BELL AT THE �H HEAT DETECTOR TERMINALS LEADS PLATE TERMINALS FACP. THE SMOKE/HEAT ALARM BELLS MAY BE SILENCED BY OPERATION OF g THE FACP SIGNAL SILENCE SWITCH. {S SMOKE DETECTOR CONTROL UNIT INITIATING 9.FLASH ALL ALARM STROBE LIGHTS THROUGHOUT THE BUILDING.THE ALARM FIRE COMBINATION ALARM HORN/STROBE DEVICE STROBE LIGHTS MAY BE TURNED OFF DURING THE ALARM CONDITION BY F LIGHT CIRCUIT OPERATION OF THE FACP ALARM SILENCE SWITCH.SUBSEQUENT ALARM FIRE ALARM STROBE LIGHT-NUMERAL D CONDITIONS SHALL AGAIN TURN ON THE ALARM STROBE LIGHTS. THE ALARM } INDICATES CANDELA RATING. � STROBE LIGHTS SHALL BE INHIBITED FROM BEING TURNED OFF FOR A p J SPLICES PERIOD OF ONE/THREE/FIVE(1/3/5)MINUTES AFTER COMMENCING G P$ POWER SUPPLY �} OPERATION. n�Ju JUN-5 2023 VILLAGE OF RYE BROOK 10,EACH ALARM STROBE LIGHT CIRCUIT SHALL BE PROVIDED WITH A CONTROL PANEL FUSED N OUT N OUT BUILDING DEPARTMENT SYNCHRONIZED FLASH MODULE,AT THE FACP,SO THAT ALL ALARM STROBE LIGHTS CONNECTED TO ANY SINGLE ALARM STROBE LIGHT CIRCUIT SHALL CUTOUT DETAIL WIRING TERMINATION METHODS FLASH AT THE SAME TIME AT A RATE OF ONE(1)FLASH PER SECOND. N.T.S. 11.FLASH ALL ALARM STROBE LIGHTS. SUBSEQUENT ALARM CONDITION SHALL AGAIN TURN ON THE ALARM STROBE LIGHTS. THE ALARM STROBE LIGHTS A-FUSE E-KEYED LOCK FOR ENCLOSURE NO: DATE: REVISIONS SHALL BE INHIBITED FROM BEING TURNED OFF FOR A PERIOD OF FIVE(5) B-NEUTRAL(SOLID BAR) F-ENGRAVED NAMEPLATE MINUTES AFTER COMMENCING OPERATION, C-STEEL ENCLOSURE G-TO EMERGENCY POWER D-STEEL DOOR WITH HINGE H-TO FIRE ALARM CPU 12.OPERATE CONTROL RELAY CONTACTS TO SHUTDOWN ALL AIR HANDLING SYSTEMS THAT SERVE THE BUILDING AND CLOSE ANY SMOKE DAMPERS RELATED TO THOSE SYSTEMS. AIR HANDLING SYSTEMS SHALL NOT BE PERMITTED TO RESTART TO NORMAL OPERATION FROM THE SIMPLE OPERATION OF THE SYSTEM RESET SWITCH. A SEPARATE AIR HANDLING SYSTEMS RESTART SWITCH SHALL BE PROVIDED ON THE FACP TO PERMIT AIR HANDLING SYSTEMS TO BE RESTARTED AFTER THE FIRE ALARM SYSTEM HAS i --------'IIF- _, -_-_-- BEEN RESET TO NORMAL I I I ---- EXISTING BLDG.FAR& C. ELEVATOR SMOKE DETECTOR SEQUENCE SHALL COMPLY WITH THE RS 18-1 REQUIREMENTS FOR FLOOR RECALLS. F i i CONNECT T O 1412 x i ,F� I' I EXISTING BLDG. D. OPERATION OF WATERFLOW SWITCH WILL EFFECT THE SAME ACTIONS AS AN FACP I F A C P & :POWER AREA SMOKE DETECTOR IN ALARM PLUS INITIATE ELEVATOR RECALL. $f cN N ANNUNCIATORF F F F F S S 11m �TII PPLY E. ACTIVATION OF A SPRINKLER SUPERVISORY INITIATING DEVICE SHALL: sEWNE 1. 102f1202Y ISSUED FORBID&FILING NE 2.TRANSMIT HA SUPERVISORY CONDITION,VIA NTOEGRAL CENTRAL STATION oININc ogoEu EXISTING CONTROL/DISPLAY ( ) Ji 1#8G-3/a"C(GROUND TO WATER MAIN N0: DATE: REMARKS �I BLDG.FACPi AHEAD OF THE MAIN VALVE-USE ----ter - _ H "' m _ xarloN I� I I i APPROVED GROUND CLAMP) COMMUNICATOR,TO CENTRAL STATION/LOCAL FIRE. 0 3.VISUALLY ANNUNCIATE THE INDIVIDUAL POINT OF ALARM ON ALL REMOTE S a. ® l I, DRAWING TITLE: ANNUNCIATOR PANELS. THE VISUAL INDICATION SHALL REMAIN ON UNTIL THE (2} PAIRS OF#16 FPLP IN EMT TO(2) DEDICATED TELEPHONE LINES AT POINT OF FIRE ALARM SYMBOLS ALARM CONDITION IS RESET TO NORMAL. r( F r ENTRY INTO BLDG.MAIN TELEPHONE BOARD NOTES,PLAN AND RISER F.THE ENTIRE FIRE ALARM SYSTEM WIRING SHALL BE ELECTRICALLY SUPERVISED 4' } i BOND GROUND TO METALLIC HOUSING OF FCS TO AUTOMATICALLY DETECT AND REPORT TROUBLE CONDITIONS TO THE FIRE I f i i i AND CAP WITH APPROVED CLAMP DIAGRAM ALARM CONTROL PANEL. ANY OPENS,GROUNDS OR DISARRANGEMENT OF �- ii L------------------------ SYSTEM WIRING AND SHORTS ACROSS ALARM SIGNALING WIRING SHALL { ____________________________________ 6 2#12,#12G,3/4"C TO EXISTING OWNER PANEL IN AUTOMATICALLY: � D ______________EXISTING MAIN ELECTRIC ROOM ON FLOOR BELOW 1.UPDATE THE CONTROL/DISPLAY AS DESCRIBED ABOVE(A.1.) IDVol 2.TRANSMIT A TROUBLE CONDITION,VIA THE INTEGRAL CENTRAL STATION GROUND FL. SEAL&SIGNATURE: DATE: 01/25/21 PROJECT No: COMMUNICATOR,TO CENTRAL STATION/LOCAL FIRE DEPARTMENT. 6F IV DRAWN BY: DJ 3.VISUALLY AND AUDIBLY ANNUNCIATE A GENERAL TROUBLE CONDITION,ON THE FIRE ALARM RISER DIAGRAM EW CRECK'D BY:SC REMOTE ANNUNCIATOR PANELS, THE VISUAL INDICATION SHALL REMAIN ON DWG.No.: Nr N A E 9 UNTIL THE TROUBLE CONDITION IS REPAIRED. TARBUC"$ NOT TO SCALE a+ a I n e N r `'a�' ti4 s 3 FIRE ALARM(GROUND)FL.PLAN FA100.00 -i, SCALE:Y8"=1'-O" A a{sssloN�` FILEING TYPE I CADO FILE NO: 1 OF 4 PROJECT: CHOPT 116 South Ridge St. TEMPORAL 3 FIRE ALARM SYSTEM A.SECURE PERMITS AND APPROVALS PRIOR TO INSTALLATION. SHALL BE PROVIDED.END-OF-LINE RESISTORS(AND VALUES) EXCLUSIVELY THAT OF THE CONSULTING ENGINEER. VERSION,PROJECT REVISION NUMBER,AND THE TIME AND DATE J.EACH CONTROLLER SHALL CONTAIN A RS232 Rye Brook,NY SHALL BE DEPICTED. FALL PRODUCTS USED SHALL BE OF A SINGLE MANUFACTURER. OF THE HISTORY REPORT. PRINTER/PROGRAMMING PORT FOR PROGRAMMING LOCALLY VIA A PART 1-GENERAL B.PRIOR TO COMMENCEMENT AND AFTER COMPLETION OF WORK SUBMISSION OF NOTIFICATION APPLIANCES,AUXILIARY RELAYS,OR FALLOW THE USER TO DISABLE/ENABLE DEVICES,ZONES,ACTIONS, PC. WHEN OPERATIONAL,EACH CONTROLLER SHALL SUPPORT A NOTIFY AUTHORITIES HAVING JURISDICTION. 12.DEVICE LAYOUT FLOOR PLANS SHALL BE CREATED FOR EVERY DOCUMENTATION FROM OTHER THAN A SINGLE MANUFACTURER TIMERS AND SEQUENCES. PROTECT THE DISABLE FUNCTION WITH PRINTER THROUGH THE RS232 PORT AND BE CAPABLE OF 1.1 DESCRIPTION AREA SERVED BY THE FIRE ALARM SYSTEM.CAD FILES SHALL NOT BE ACCEPTABLE AND WILL BE GROUNDS FOR A PASSWORD. MESSAGE ROUTING. (AUTOCAD-LATEST EDITION SHALL BE PROVIDED BY THE IMMEDIATE DISAPPROVAL WITHOUT COMMENT. K.SYSTEM CIRCUITS SHALL BE CONFIGURED AS FOLLOWS: C.SUBMIT LETTER OF APPROVAL FOR INSTALLATION BEFORE ) G.ALLOW THE USER TO ACTIVATE/RESTORE OUTPUTS,ACTIONS, ADDRESSABLE ANALOG SLC LOOPS CLASS B(STYLE 4); J F N G N E E R N G A.THE REQUIREMENTS OF THE CONTRACT DOCUMENTS,INCLUDING CONSULTING ENGINEER FOR THE USE OF THE FIRE ALARM G.THE FIRE ALARM/LIFE SAFETY SYSTEM SUPPLIED UNDER THIS SEQUENCES,AND SIMULATE DETECTOR SMOKE LEVELS. REQUESTING ACCEPTANCE OF SYSTEM. INITIATING DEVICE CIRCUITS CLASS B; NOTIFICATION APPLIANCE THE GENERAL AND SUPPLEMENTARY GENERAL CONDITION AND SYSTEM EQUIPMENT VENDOR IN THE PREPARATION OF THE SPECIFICATION SHALL BE AMICROPROCESSOR-BASED.ALL DIVISION 1-GENERAL REQUIREMENTS SHALL APPLY TO THE 1.5 RELATED WORK FLOOR PLANS.FLOOR PLANS SHALL INDICATE ACCURATE CONTROL PANEL ASSEMBLIES AND CONNECTED FIELD APPLIANCES HALLOW THE SERVICE USER TO CIRCUITS"SPLIT"CLASS B;NETWORK COMMUNICATIONS CLASS B; WORK OF THIS SECTION, LOCATIONS FOR ALL CONTROL AND PERIPHERAL DEVICES. SHALL BE BOTH DESIGNED AND MANUFACTURED BY THE SAME ENTER TIME AND DATE,RECONFIGURE AN EXTERNAL PORT FOR ANNUNCIATOR COMMUNICATIONS CLASS B. 309 Lexington Ave.,Ste.309 DRAWINGS SHALL BE NO LESS THAN 1/8 INCH SCALE.ALL COMPANY,AND SHALL BE TESTED AND CROSS-LISTED AS DOWNLOAD PROGRAMMING,INITIATE AUTO PROGRAMMING AND L.SINGLE STAGE OPERATION SHALL BE PROVIDED. New York,NY 10017 BAT THE TIME OF BID,ALL EXCEPTIONS TAKEN TO THESE A.THE CONTRACTOR SHALL COORDINATE WORK IN THIS SECTION ADDRESSABLE DEVICES SHALL BE DEPICTED WITH A DISCRETE COMPATIBLE TO ENSURE THAT A FULLY FUNCTIONING LIFE SAFETY CHANGE PASSWORDS. PROTECT THESE FUNCTIONS WITH A SPECIFICATIONS,ALL VARIANCES FROM THESE SPECIFICATION AND PASSWORD. M.THE SYSTEM SHALL HAVE A UL 212 687 3 0 5 0:phone ADDRESS WHICH CORRESPONDS WITH THAT INDICATED ON THE SYSTEM IS DESIGNED AND INSTALLED. ALL SUBSTITUTIONS OF OPERATING CAPABILITIES OR EQUIPMENT WITH ALL RELATED TRADES. WORK AND EQUIPMENT RISER DIAGRAM.ALL NOTIFICATION APPLIANCES SHALL ALSO I.THE END-USER SHALL RETAIN COMPLETE RIGHTS AND LISTED DETECTOR SENSITIVITY TEST FEATURE,WHICH WILL BE A CALLED FOR IN THESE SPECIFICATION SHALL BE LISTED IN PROVIDED IN OTHER SECTIONS AND RELATED TO THE FIRE ALARM FUNCTION OF THE SMOKE DETECTORS AND PERFORMED 2 1 2 687 3053 f a x WRITING AND FORWARDED TO THE ENGINEER. ANY SUCH SYSTEM SHALL INCLUDE,BUT NOT BE LIMITED TO: BE PROVIDED WITH A CIRCUIT ADDRESS WHICH CORRESPONDS 2.2 CIRCUITING GUIDELINES OWNERSHIP TO ALL SOFTWARE RUNNING IN THE SYSTEM.THE AUTOMATICALLY EVERY 4 HOURS. EXCEPTION,VARIANCES OR SUBSTITUTIONS THAT WERE NOT 1.SPRINKLER WATERFLOW AND SUPERVISORY SWITCHES SHALL TO THAT DEPICTED ON THE RISER DIAGRAM.IF IND11VIDUAL FIRE ALARM EQUIPMENT VENDOR SHALL PROVIDE USEABLE HARD LISTED AT THE TIME OF BID AND ARE IDENTIFIED IN THE FLOORS NEED TO BE SEGMENTED TO ACCOMMODATE THE AND SOFT COPIES OF THE SOFTWARE DATABASE TO THE N.THE SYSTEM SHALL SUPPORT SUBMITTAL,SHALL BE GROUNDS FOR IMMEDIATE DISAPPROVAL BE FURNISHED AND INSTALLED BY THE FIRE PROTECTION A.EACH ADDRESSABLE ANALOG LOOP SHALL BE CIRCUITED SO 1/8"SCALE REQUIREMENTS,KEY PLANS AND BREAK-LINES END-USER AT THE END OF THE WARRANTY PERIOD.THE 100%OF ALL REMOTE DEVICES IN ALARM AND PROVIDE SUPPORT CONTRACTOR,BUT WIRED AND CONNECTED BY THE SHALL BE PROVIDED ON THE PLANS IN AN ORDERLY AND DEVICE LOADING IS NOT TO EXCEED 80%OF LOOP CAPACITY IN DATABASE PROVIDED SHALL BE USEABLE BY ANY AUTHORIZED FORA 100%COMPLIMENT OF DETECTOR ISOLATOR BASES. WITHOUT COMMENT. ELECTRICAL CONTRACTOR.MODIFICATION OF EXISTING ORDER TO LEAVE FOR SPACE FOR FUTURE DEVICES. THE LOOP PROFESSIONAL MANNER.END-OF-LINE RESISTORS(AND AND CERTIFIED DISTRIBUTOR OF THE PRODUCT LINE,AND SHALL C.THE P O.ALL PANEL MODULES SHALL BE MIN ENTIRE SYSTEM SHALL BE INSTALLED WITH AESTHETICS IN SPRINKLER DEVICES TO ACCOMMODATE MONITORING BY THE SHALL HAVE CLASS B OPERATION MIND. ALL CONTROL PANELS AND REMOTE ANNUNCIATORS NEW FIRE ALARM SYSTEM SHALL BE THE RESPONSIBILITY OF VALUES)SHALL BE DEPICTED. INCLUDE ALL APPLICABLE PASSWORDS NECESSARY FOR TOTALB.WHERE IT IS NECESSARY TO INTERFACE CONVENTIONAL INITIATING AND UNRESTRICTED USE AND MODIFICATION OF THE DATABASE. SUPERVISED FOR PLACEMENT AND RETURN TROUBLE IF DAMAGED INSTALLED IN PUBLIC SPACES SHALL BE SEMI-FLUSH MOUNTED THE FIRE ALARM SYSTEM INSTALLING CONTRACTOR. DEVICES PROVIDE INTELLIGENT INPUT MODULES TO SUPERVISE THE CONSULTING ENGINEER SHALL DEFINE THE EXTENT OF OR REMOVED. WITH NO EXPOSED CONDUIT OR CABLE TRAYS. 2.DUCT SMOKE DETECTORS SHALL BE FURNISHED,WIRED AND CONTAINED IN THE TITLE BLOCK OF EACH DRAWING SHALL BE CLASS B ZONE WIRING. HARDCOPY DATABASE DOCUMENTATION TO BE PROVIDED. P.THE SYSTEM SHALL HAVE A CPU WATCHDOG CIRCUIT TO INITIATE CONNECTED BY THE ELECTRICAL CONTRACTOR. THE HVAC SYMBOL LEGENDS WITH DEVICE COUNTS,WIRE TAG LEGENDS, C.EACH OF THE FOLLOWING TYPES OF DEVICES OR EQUIPMENT TROUBLE SHOULD THE CPU FAIL. 1.2 WORK INCLUDED CONTRACTOR SHALL FURNISH NECESSARY DUCT OPENING TO CIRCUIT SCHEDULES FOR ALL ADDRESSABLE AND NOTIFICATION 2.5 UL LISTED AND APPROVED EQUIPMENT INSTALL THE DUCT SMOKE DETECTORS. APPLIANCE CIRCUITS,THE PROJECT NAME/ADDRESS,AND A SHALL BE PROVIDED WITH SUPERVISED CIRCUITS AS SHOWN ON Q,THE FIRE ALARM/LIFE SAFETY A.THE WORK COVERED BY DRAWING DESCRIPTION WHICH CORRESPONDS TO THAT THE DRAWINGS BUT SHALL BE TYPICALLY AS FOLLOWS: SYSTEM SHALL CODE THE NOTIFICATION APPLIANCE CIRCUITS WITH SHALL INCLUDE ALL LABOR,THIS SECTION BOR,EQUIPMENT,, THE SPECIFICATION 3.NEW AIR HANDLING AND SMOKE EXHAUST SYSTEM FAN MATERIALS AND CONTROL CIRCUITS AND STATUS CONTACTS TO BE FURNISHED INDICATED IN THE DRAWING INDEX ON THE COVERSHEET 1.SPRINKLER VALVE SUPERVISORY SWITCHES: PROVIDE ONE AFIRE ALARM CONTROL PANEL REQUIREMENTS: THE INDUSTRY STANDARD TEMPORAL 3 PATTERN. SERVICES TO FURNISH AND INSTALL A COMPLETE FIRE ALARM BY THE HVAC CONTROL EQUIPMENT. DRAWING.A SECTION OF EACH DRAWING TITLE BLOCK SHALL (1)SUPERVISORY MODULE CIRCUIT FOR EACH SPRINKLER R.AUDIBLE NOTIFICATION APPLIANCES SHALL BE AFFECTED BY SYSTEM OF THE ADDRESSABLE,NON-CODED TYPE.IT SHALL BE 4.INSTALLING DEDICATED OUTGOING RJ-31X TELEPHONE LINES BE RESERVED FOR REVISION NUMBERS AND NOTES.THE INITIAL VALVE SUPERVISORY SWITCH. THE FIRE ALARM CONTROL PANEL OR PANELS AND ALL SYSTEM SIGNAL SILENCE FEATURES. VISUAL SIGNAL APPLIANCE SHALL COMPLETE WITH ALL NECESSARY HARDWARE,SOFTWARE AND (2)SHALL BE THE RESPONSIBILITY OF THE INSTALLING SUBMISSION SHALL BE REVISION 0,WITH REVISION A,B,OR C DEVICES(HORN-STROBES,STROBES,PULL STATIONS,SMOKE AND NOT BE AFFECTED BY SIGNAL SILENCE FEATURES. MEMORY SPECIFICALLY TAILORED FOR THIS INSTALLATION.IT ELECTRICAL CONTRACTOR.ESTABLISHMENT OF CENTRAL AS PROJECT MODIFICATIONS REQUIRE. 2.WHEN WATERFLOW AND TAMPER SWITCHES EXIST AT THE HEAT DETECTORS,ETC.SHALL BIE EDWARDS SYSTEMS S.USER INTERFACE SHALL BE POSSIBLE TO PERMANENTLY MODIFY THE SOFTWARE ON STATION MONITORING ACCOUNT SHALL BE THE RESPONSIBILITY SAME LOCATION,PROVIDE ONE(1)DUAL INPUT ADDRESSABLE TECHNOLOGY(EST)BY GE SECURITY TYPE EST3 SERIES(OR THE 3-LCDXL DISPLAY MODULE SHALL BE OF MEMBRANE STYLE SITE BY USING A PLUG-IN PROGRAMMER. THE SYSTEM SHALL OF THE FIRE ALARM EQUIPMENT VENDOR. I.BATTERY CALCULATIONS SHALL BE PROVIDED ON A PER POWER MODULE.WHEN ODD NUMBERS OF DEVICES EXIST AT A EQUAL).ALL UNDER ONE LABEL UL LISTED AND APPROVED CONSTRUCTION WITH A 24 LINE BY 40-CHARACTER(960 TOTAL CONSIST OF,BUT NOT BE LIMITED TO,THE FOLLOWING: SUPPLY/CHARGER BASIS BASED ON RS 17-5 REQUIREMENTS. SINGLE LOCATION,PROVIDE ADDITIONAL SINGLE INPUT FOR THE USE OF FIRE ALARM SYSTEMS IN THIS AREA OF THE 1.FIRE ALARM CONTROL PANEL AND RELATED REMOTE DATA CHARACTERS 1.6 SUBMITTALS THESE CALCULATIONS SHALL CLEARLY INDICATE THE QUANTITY OF UNITED STATES OF AMERICA. )LIQUID CRYSTAL DISPLAY(LCD). THE LCD SHALL LCUL ADDRESSABLE MODULES. GATHERING PANELS. DEVICES,THE DEVICE PART NUMBERS,THE SUPERVISORY THE OPERATING CONTROLS SHALL BE LOCATED BEHIND LOCKED USE SUPER-TWIST TECHNOLOGY AND BACKLIGHTING FOR HIGH CURRENT DRAW,THE ALARM CURRENT DRAW,TOTALS FOR ALL DOOR WITH VIEWING WINDOW. ALL CONTROL MODULES SHALL BE CONTRAST VISUAL CLARITY AND A COLORED GRAY/BLACK AND 2.REMOTE ANNUNCIATORS WITH SEMI FLUSH BACKBOX. A.PROVIDE LIST OF ALL TYPES OF EQUIPMENT AND COMPONENTS CATEGORIES,AND THE CALCULATED BATTERY REQUIREMENTS. D.ALARM: THE FACP CENTRAL PROCESSING UNIT(CPU)SHALL LABELED,AND ALL ZONE LOCATIONS SHALL BE IDENTIFIED. WHITE DISPLAY. IN THE NORMAL MODE THE LCD SHALL DISPLAY 3.ADDRESSABLE MANUAL FIRE ALARM STATIONS. PROVIDED.THIS SHALL BE INCORPORATED AS PART OF A TABLE BATTERY CALCULATIONS SHALL ALSO REFLECT ALL CONTROL PROVIDE A GENERAL ALARM TEMPORAL 3-CODE OPERATION. THE TIME,A CUSTOMER FACILITY NAME,AND THE NUMBER OF OF CONTENTS,WHICH WILL ALSO INDICATE THE MANUFACTURER'S PANEL COMPONENT,REMOTE ANNUNCIATOR,AND AUXILIARY RELAY B.SYSTEM CONTROLLERS HISTORY EVENTS. IN THE ALARM MODE THE LCD DISPLAY THE 4.ADDRESSABLE ANALOG AREA SMOKE DETECTORS. PART NUMBER,THE DESCRIPTION OF THE PART,AND THE PART E.EACH OF THE FOLLOWING TYPES OF ALARM NOTIFICATION TOTAL NUMBER OF EVENTS AND THE TYPE OF EVENT ON 5.ADDRESSABLE ANALOG DUCT SMOKE DETECTORS. CURRENT DRAWS.FAILURE TO PROVIDE THESE CALCULATIONS APPLIANCES SHALL BE CIRCUITED AS SHOWN ON THE DRAWINGS THE MAIN CONTROLLER 3-CPU SHALL BE SUPERVISED,SITE NUMBER OF THE MANUFACTURER'S PRODUCT DATASHEET ON SHALL BE GROUNDS FOR THE COMPLETE REJECTION OF THE PROGRAMMABLE,AND OF MODULAR DESIGN SUPPORTING UP TO DISPLAY. THE LCD SHALL RESERVE 42 CHARACTERS OF DISPLAY 6.ADDRESSABLE ANALOG HEAT DETECTORS. WHICH THE INFORMATION CAN BE FOUND. BUT SHALL BE TYPICALLY AS FOLLOWS: SUBMITTAL PACKAGE. 125 DETECTORS AND 125 REMOTE MODULES PER ADDRESSABLE SPACE FOR EACH USER CUSTOM MESSAGE BY ADDRESSABLE 1.AUDIBLE SIGNALS: PROVIDE SUFFICIENT SPARE CAPACITY TO SIGNALING LINE CIRCUIT(SLC). THE CPU SHALL SUPPORT UP DEVICE, THE MODULE SHALL HAVE VISUAL INDICATORS FOR THE 7.MAGNETIC DOOR\CARD ACCESS RELEASE OVERRIDE CONTROL. B.PROVIDE DESCRIPTION OF OPERATION OF THE SYSTEM(SEQUENCE ASSURE THAT THE ADDITION OF FIVE(5)AUDIBLE DEVICES TO 10 SLC'S PER PANEL FOR A TOTAL SYSTEM CAPACITY OF FOLLOWING COMMON CONTROL FUNCTIONS;POWER,ALARM, 8.AUDIBLE NOTIFICATION APPLIANCES-HORNS. OF OPERATION),SIMILAR TO THAT PROVIDED IN PART 2 OF THIS J.TABLE OF CONTENTS,PRODUCT DATA SHEETS,SEQUENCES OF CAN BE SUPPORTED WITHOUT THE NEED FOR ADDITION SUPERVISORY,MONITOR,TROUBLE,DISABLE,GROUND FAULT,CPU SECTION OF THE SPECIFICATIONS,TO INCLUDE ANY AND ALL 2500 INTELLIGENT ADDRESSABLE POINTS. THE SYSTEM SHALL 9.VISUAL NOTIFICATION APPLIANCES-STROBES. OPERATION,BATTERY CALCULATIONS,INSTALLATION INSTRUCTIONS, CONTROL COMPONENTS(POWER SUPPLIES,SIGNAL CIRCUIT BE DESIGNED WITH PEER-TO-PEER NETWORKING CAPABILITY FOR FAIL,AND TEST. THERE SHALL BE COMMON CONTROL KEYS AND 10.CENTRAL STATION ALARM CONNECTION CONTROL. EXCEPTIONS,VARIANCES OR SUBSTITUTIONS LISTED AT THE TIME LICENSES,NICET CERTIFICATIONS AND B-SIZE(BLACKLINE) MODULES,AMPLIFIERS,BATTERIES,ETC.) ENHANCED SURVIVABILITY,WITH SUPPORT FOR UP TO 64 MODES, VISUAL INDICATORS FOR RESET,ALARM SILENCE,PANEL SILENCE, OF BID. ANY SUCH EXCEPTIONS,VARIANCES OR SUBSTITUTIONS AND DRILL. PROVIDE FOUR PAIRS OF DISPLAY CONTROL KEYS REDUCED SHOP DRAWINGS SHALL BE PROVIDED BY THE FIRE EACH WITH TO 2500 POINTS AND AN OVERALL CAPACITY 11.AIR HANDLING SYSTEMS SHUTDOWN CONTROL. THAT WERE NOT LISTED AT THE TIME OF BID AND ARE IDENTIFIED ALARM VENDOR AS PART OF A SINGLE,SPIRAL BOUND SUBMITTAL 2.VISUAL SIGNALS PROVIDE SUFFICIENT SPARE CAPACITY TO 160,000 POINTS.THE CABINETS SHALL BE STEEL,WITH A REDD FOR SELECTION OF EVENT DISPLAY BY TYPE(ALARM, 12.MAGNETIC DOOR HOLDER RELEASE. IN THE SUBMITTAL,SHALL BE GROUNDS FOR IMMEDIATE BOOK.THE SUBMITTAL BOOK SHALL HAVE LAMINATED COVERS ASSURE THAT THE ADDITION OF THREE(3)VISUAL DEVICES FINISH. SUPERVISORY,MONITOR AND TROUBLE)AND FORWARD/ 13.SPRINKLER SUPERVISORY SWITCHES AND TAMPER SWITCH DISAPPROVAL WITHOUT COMMENT.THE SEQUENCE OF OPERATION INDICATING THE PROJECT ADDRESS,SED NUMBER,SYSTEM TYPE, CAN BE SUPPORTED WITHOUT THE NEED FOR ADDITION BACKWARD SCROLLING THROUGH EVENT LISTINGS, THE SHALL BE PROJECT SPECIFIC,AND SHALL PROVIDE INDIVIDUAL CONTROL COMPONENTS POWER SUPPLIES,SIGNAL CIRCUIT C.THE SYSTEM SHALL STORE ALL BASIC SYSTEM FUNCTIONALITY SUPERVISION. SEQUENCES FOR EVERY TYPE OF ALARM,SUPERVISORY,OR AND CONTRACTOR.THE BOOK SHALL CONSIST OF LABELED ( AND JOB SPECIFIC DATA IN NON-VOLATILE MEMORY. ALL SITE OPERATION OF THESE KEYS SHALL BE INTEGRATED WITH THE 14.BATTERY STANDBY. TROUBLE CONDITION THAT MAY OCCUR AS PART OF NORMAL OR DIVIDERS,AND SHALL NOT EXCEED 9%"IN WIDTH,AND 11'{2" MODULES,BATTERIES,ETC.) SPECIFIC AND OPERATING DATA!SHALL SURVIVE A COMPLETE RELATED COMMON CONTROL INDICATORS TO FLASH THE OFF-NORMAL SYSTEM USE. IN HEIGHT.NO LESS THAN THREE(3)SETS OF SUBMITTAL POWER FAILURE INTACT. PASSWORDS SHALL PROTECT ANY INDICATORS WHEN UNDISPLAYED EVENTS ARE AVAILABLE FOR BOOKLETS SHALL BE PROVIDED TO THE CONSULTING ENGINEER DISPLAY AND TURN ON STEADY WHEN ALL EVENTS HAVE BEEN ALL RYE BROOK FIRE ALARM PERIPHERALS,SUCH AS C.PROVIDE MANUFACTURER'S ORIGINAL PRINTED PRODUCT DATA, FOR REVIEW AND COMMENT.ADDITIONAL COPIES MAY BE 3.SMOKE ALARM BELL(AT FACP):PROVIDE ONE(1)ALARM CHANGES TO SYSTEM OPERATIONS. DISPLAYED. THE LCD SHALL DISPLAY THE FIRST EVENT OF THE CODE CARDS,PLACARDS,RISER DIAGRAM,NECESSARY SWITCHES, CATALOG CUTS AND DESCRIPTION OF ANY SPECIAL INSTALLATION REQUIRED AT NO ADDITIONAL COST TO THE PROJECT. BELL CIRCUIT,WATERFLOW ALARM BELL(AT PANEL): D.THE MAIN CONTROLLER MODULE SHALL CONTROL AND MONITOR HIGHEST PRIORITY AS WELL AS THE PREVIOUS SEVEN(7)ALARM LED'S,CLOCK,FIRE SIGN,MANUAL CENTRAL OFFICE TRIP,FUSE PROCEDURES.PHOTOCOPIED AND/OR ILLEGIBLE PRODUCT DATA PROVIDE ONE(1)WATERFLOW BELL CIRCUIT,SYSTEM ALL LOCAL OR REMOTE PERIPHERALS. IT SHALL SUPPORT A EVENTS?HANDS FREE?IN CHRONOLOGICAL ORDER SO THAT THE CUTOUT,FIRE DEPT.OF RYE BROOK APPROVED LOCKS,WITH SHEETS SHALL NOT BE ACCEPTABLE.ALL PRODUCT DATASHEETS TROUBLE BELL(AT FACP): PROVIDE ONE(1)BELL CIRCUIT, LARGE 960 CHARACTER LCD,POWER SUPPLY,REMOTE LCD AND ARRIVING FIREFIGHTER MAY TRACK THE FIRES PROGRESSION. ENCLOSED PURGE SWITCHES SHALL BE INCLUDED IN THE SYSTEM SHALL BE HIGHLIGHTED OR STAMPED WITH ARROWS TO INDICATE K.SCALE DRAWING SETS SHALL BE SUBMITTED ALONG WNTH THE ZONE DISPLAY ANNUNCIATORS,PRINTERS,AND SUPPORT PROVIDE SYSTEM FUNCTION KEYS;STATUS,REPORTS,ENABLE, PRICE. DATA GATHERING PANELS SHALL BE CONNECTED TO A THE SPECIFIC COMPONENTS BEING SUBMITTED FOR APPROVAL, SUBMITTAL BOOKLETS.THESE DRAWINGS MAY BE EITHER D-SIZE COMMUNICATION INTERFACE STANDARD PROTOCOL(CSI)DEVICES DISABLE,ACTIVATE,RESTORE,PROGRAM,AND TEST. THE MODULE OR E-SIZE BLUELINE DRAWINGS AND OF A SUFFICIENT F.EACH OF THE FOLLOWING TYPES OF REMOTE EQUIPMENT POWER RISER WITH A FUSE CUTOUT CONNECTION OR FUSED SUCH AS COLOR COMPUTER ANNUNCIATORS AND COLOR GRAPHIC SHALL HAVE A NUMERIC KEYPAD,ZERO THROUGH NINE WITH D.PROVIDE MANUFACTURER'S INSTALLATION INSTRUCTION MANUAL RESOLUTION TO BE COMPLETELY READ.SETS SHALL BE BOUND ASSOCIATED WITH THE FIRE ALARM SYSTEM SHALL BE PROVIDED DISCONNECT. A COMMON GROUND SHALL BE INCLUDED IN THE WITH A FORM'C'CONTROL RELAY CONTACT AS SHOWN ON THE DISPLAYS.REMOTE LCD ANNUNCIATORS SHALL ALSO DISPLAY DELETE AND ENTER KEYS. POWER RISER, FOR SPECIFIED SYSTEM. AND FOLDED SO AS TO NOT TAKE UP MORE THAN 100 SQUARE EACH AND EVERY POINT IN THE SYSTEM AND BE SIZED WITH AS AN ALTERNATE IF THE ABOVE CANNOT BE PROVIDED,PROVIDE E.PROVIDE SAMPLES OF VARIOUS ITEMS WHEN REQUESTED. INCHES OF SPACE.NO LESS THAN THREE(3)SETS OF SCALE DRAWINGS,BUT SHALL BE TYPICALLY AS FOLLOWS: THE SAME NUMBER OF CHARACTERS AS IN THE MAIN FACP UL-LISTED 864 PC GRAPHICS DISPLAY. 1.3 APPLICABLE CODES AND STANDARDS F.PROVIDE COPY OF NYS LICENSE TO PERFORM SUCH WORK. DRAWING SETS SHALL BE PROVIDED TO THE CONSULTING DISPLAY. ENGINEER FOR REVIEW AND COMMENT.ADDITIONAL COPIES MAY 1.HVAC FAN SYSTEMS: PROVIDE ONE(1)SHUTDOWN CONTROL E.THE PANEL SHALL HAVE AN INTERFACE MODULE FOR REMOTE A.ALL EQUIPMENT SHALL BE UL LISTED FOR ITS INTENDED USE G.PROVIDE COPIES OF NICET LEVEL II FIRE ALARM CERTIFICATIONS BE REQUIRED AT NO ADDITIONAL COST TO THE PROJECT. RELAY CONTACT FOR EACH HVAC FAN SYSTEM. SITE MONITORING. THE MODULE SHALL HAVE A DIALER(ALARM AND CONFORM TO THE LATEST UL STANDARDS. FOR THE TWO(2)TECHNICIANS ASSIGNED TO THIS PROJECT. 1.7 WARRANTY COMMUNICATOR TRANSMITTER(DACT)}MODULE TO TRANSMIT BANDERWRITERS LABORATORIES INC.: THE SYSTEM AND ALL H.PROVIDE SHOP DRAWINGS AS ALARM,SUPERVISORY AND TROUBLE SIGNALS TO A CENTRAL MONITORING STATION FOLLOWS: 2.HVAC SUPPLY FANS: PROVIDE ONE(1)SHUTDOWN CONTROL ) THE DACT SHALL SUPPORT DUAL COMPONENTS SHALL BE LISTED BY UNDERWRITERS LABORATORIES RELAY CONTACT FOR EACH HVAC SUPPLY FAN. (CMS. INC.FOR USE IN FIRE PROTECTIVE SIGNALING SYSTEM UNDER 6.COVERSHEET WITH PROJECT NAME,ADDRESS AND DRAWING A.ALL WORK PERFORMED AND ALL MATERIAL AND EQUIPMENT TELEPHONES LINES,CONTACT I.D.COMMUNICATIONS,AND THE FOLLOWING STANDARDS AS APPLICABLE: INDEX. FURNISHED UNDER THIS CONTRACT SHALL BE FREE FROM CONFIGURED FOR DUAL TONE MULTI-FREQUENCY(DTMF)OR DEFECTS AND SHALL REMAIN SO FOR A PERIOD OF AT LEAST 3.HVAC RETURN FANS: PROVIDE ONE(1)SHUTDOWN CONTROL PULSE MODES, IT SHALL BE POSSIBLE TO DELAY AC POWER UL 864/UOJZ,APOU CONTROL UNITS FOR FIRE PROTECTIVE ONE(1)YEAR FROM THE DATE OF ACCEPTANCE OR APPROVAL RELAY CONTACT FOR EACH HVAC RETURN FAN. FAILURE REPORTS,AUTO TEST CALL,AND BE SITE SIGNALING SYSTEMS. 7.GENERAL NOTES DRAWING WITH PERIPHERAL DEVICE BACKBOX BY AHJ.THE FULL COST OF MAINTENANCE,LABOR AND PROGRAMMABLE.THE DIALER SHALL BE CAPABLE OF UL 268 SMOKE DETECTORS FOR FIRE PROTECTIVE SIGNALING SIZE INFORMATION,PART NUMBERS,DEVICE MOUNTING HEIGHT MATERIALS REQUIRED TO CORRECT ANY DEFECT DURING THIS TRANSMITTING EVERY INDIVIDUAL ALARM CONDITION TO THE INFORMATION,AND THE NAMES,ADDRESSES,POINT OF ONE YEAR PERIOD SHALL BE INCLUDED IN THE SUBMITTAL BID. &PROVIDE A DEDICATED 24VDC CIRCUIT TO FEED ALL AUXILIARY SYSTEMS. CENTRAL STATION, UL 268A SMOKE DETECTORS FOR DUCT APPLICATIONS. CONTACT,AND TELEPHONE NUMBERS OF ALL CONTRACT RELAYS REQUIRED FOR INDUCTIVE LOADS.CIRCUITS SHALL BE PROJECT TEAM MEMBERS. PART II-PRODUCTS SUPERVISED VIA AN END-OF-LINE RELAY AND ADDRESSABLE F.THE SYSTEM SHALL HAVE BUILT-IN AUTOMATIC SYSTEM UL 217 SMOKE DETECTORS SINGLE STATION. INPUT MODULE.AUXILIARY RELAYS SHALL NOT DERIVE THEIR PROGRAMMING TO AUTOMATICALLY ADDRESS AND MAP ALL SYSTEM UL 521 HEAT DETECTORS FOR FIRE PROTECTIVE SIGNALING 2.1 ACCEPTABLE MANUFACTURERS POWER FROM THE STARTER OR LOAD BEING CONTROLLED. DEVICES ATTACHED TO THE MAIN CONTROLLER. A MINIMUM SYSTEMS. 8.DEVICE RISER DIAGRAM THAT INDIVIDUALLY DEPICTS ALL DEFAULT SINGLE STAGE ALARM SYSTEM OPERATION SHALL BE UL 228 DOOR HOLDERS FOR FIRE PROTECTIVE SIGNALING CONTROL PANELS,ANNUNCIATORS,ADDRESSABLE DEVICES, SUPPORTED WITH ALARM SILENCE,EVENT SILENCE,DRILL,LAMP AND NOTIFICATION APPLIANCES.SHALL INCLUDE A SPECIFIC, A.THE CATALOG NUMBERS USED ARE THOSE OF THE PREFERRED REACH CONTROL OR DATA TEST,AND RESET COMMON CONTROLS, SYSTEMS. PROPOSED POINT DESCRIPTOR ABOVE EACH ADDRESSABLE FIRE ALARM MANUFACTURER EDWARDS SYSTEMS TECHNOLOGY GATHERING PANEL SHALL HAVE A DEDICATED 20AMP-120VAC UL 464 AUDIBLE SIGNALING APPLIANCES. DEVICE.SHALL INCLUDE A SPECIFIC,DISCRETE POINT (EST)BY GE SECURITY?OR EQUAL?,AND CONSTITUTE THE TYPE FEED.AN APPROPRIATE FUSE CUT OUT SHALL BE INCLUDED, G.ADVANCED WINDOWS-BASED SYSTEM DEFINITION UTILITY WITH ADDRESS THAT SHALL CORRESPOND TO ADDRESSES DEPICTED AND QUALITY OF EQUIPMENT TO BE FURNISHED. WIRED AS INDICATED IN THE BUILDING CODE FOR THE CITY OF PROGRAM VERSION REPORTING TO DOCUMENT ANY AND ALL UL 1638 VISUAL SIGNALING APPLIANCES. ON THE DEVICE LAYOUT FLOOR PLANS.DRAWING SHALL NY. CHANGES MADE DURING SYSTEM START-UP OR SYSTEM UL 38 MANUALLY ACTIVATED SIGNALING BOXES. PROVIDE WIRE SPECIFICATIONS,AND WIRE TAGS SHOWN ON B.IF EQUIPMENT OF ANOTHER MANUFACTURER IS TO BE SUBMITTED COMMISSIONING SHALL BE USED TO MAINTAIN SITE SPECIFIC UL 346 WATERFLOW INDICATORS FOR FIRE PROTECTIVE ALL CONDUCTORS DEPICTED ON THE RISER DIAGRAM.ALL FOR APPROVAL AS EQUAL,THE CONTRACTOR SHALL,AT THE TIME 2.4 SUPPORT FOR INSTALLER AND OWNER MAINTENANCE PROGRAMMING. TIME AND DATE STAMPS OF ALL MODIFICATIONS SIGNALING SYSTEMS. CIRCUITS SHALL HAVE DESIGNATIONS THAT SHALL OF BID,LIST ALL EXCEPTIONS TAKEN TO THESE SPECIFICATIONS, MADE TO THE PROGRAM MUST BE INCLUDED TO ALLOW FULL CORRESPOND WITH THOSE REQUIRE ON THE CONTROL PANEL ALL VARIANCES FROM THESE SPECIFICATIONS AND ALL RETENTION OF ALL PREVIOUS PROGRAM VERSION DATA. IT NO: DATE: REVISIONS UL 1971 STANDARD FOR SIGNALING DEVICES FOR THE HEARING SUBSTITUTIONS OF OPERATING CAPABILITIES OR EQUIPMENT A.PROVIDE A CODED ONE-MAN WALK TEST FEATURE. ALLOW SHALL SUPPORT PROGRAMMING OF ANY INPUT POINT TO ANY IMPAIRED AND FLOOR PLAN DRAWINGS.END-OF-LINE RESISTORS(AND CALLED FOR IN THESE SPECIFICATIONS AND FORWARD SAID LIST AUDIBLE OR SILENT TESTING. SIGNAL ALARMS AND TROUBLES OUTPUT POINT. THE SYSTEM SMALL SUPPORT THE USE OF BAR UL 1481 POWER SUPPLIES FOR FIRE PROTECTIVE SIGNALING VALUES)SHALL BE DEPICTED. TO THE ENGINEER. ANY SUCH EXCEPTIONS,VARIANCES OR DURING TEST. ALLOW RECEIPT OF ALARMS AND PROGRAMMED CODE READERS TO ASSIST CUSTOM PROGRAMMING FUNCTIONS. SYSTEMS. SUBSTITUTIONS THAT WERE NOT LISTED AT THE TIME OF BID AND OPERATIONS FOR ALARMS FROM AREAS NOT UNDER TEST. IT SHALL ALLOW AUTHORIZED CUSTOMIZATION OF FUNDAMENTAL UL 1711 AMPLIFIERS FOR FIRE PROTECTIVE SIGNALING 9.CONTROL PANEL TERMINATION DRAWINGS.SHALL DEPICT ARE IDENTIFIED IN THE SUBMITTAL,SHALL BE GROUNDS FOR SYSTEM OPERATIONS USING INITIATING EVENTS TO START ACTIONS, (} IMMEDIATE DISAPPROVAL WITHOUT COMMENT. FINAL B.PROVIDE INTERNAL SYSTEM DIAGNOSTICS AND MAINTENANCE USER TIMERS,SEQUENCES AND LOGICAL ALGORITHMS. THE SYSTEM SYSTEMS. INTERNAL COMPONENT PLACEMENT AND ALL INTERNAL AND DETERMINATION OF COMPLIANCE WITH THESE SPECIFICATIONS INTERFACE CONTROLS TO REPORT THE POWER, , UUKL THE FIRE ALARM SYSTEM SHALL BE UUKL FOR FIELD TERMINATION POINTS.DRAWING SHALL PROVIDE A / PROGRAM SHALL MEET THE REQUIREMENTS THIS PROJECT, SHALL REST WITH THE ENGINEER,WHO,AT HIS DISCRETION,MAY COMMUNICATION,AND GENERAL STATUS OF SPECIFIC PANEL CURRENT CODES AND STANDARDS,AND SATISFY THE LOCAL SMOKE CONTROL. DETAIL INDICATING WHERE CONDUIT PENETRATIONS SHALL BE MADE,SO AS TO AVOID CONFLICTS WITH INTERNALLY REQUIRE PROOF OF PERFORMANCE. COMPONENTS,DETECTORS,AND MODULES. AUTHORITY HAVING JURISDICTION. C.THIS INSTALLATION SHALL COMPLY WITH: MOUNTED BATTERIES.FOR EACH ADDITIONAL DATA GATHERING CALTERNATE PRODUCT SUBMISSIONS MADE WITHOUT PROOF OF NO C.PROVIDE LOOP CONTROLLER DIAGNOSTICS TO IDENTIFY COMMON DISTRIBUTED ALARM,TROUBLE,GROUND FAULT,CLASS A FAULT,AND MAP H. SYSTEM SHALL SUPPORT i.AMERICANS WITH DISABILITIES ACT(ADO) PANEL,A SEPARATE CONTROL PANEL DRAWING SHALL BE LESS THAN THREE(3)FACTORY AUTHORIZED AND CERTIFIEDDISTRIBUTED PROCESSOR INTELLIGENT DETECTORS WITH THE 2.NATIONAL ELECTRIC CODE,ARTICLE 760 WITH RYE BROOK PROVIDED,WHICH CLEARLY INDICATED THE DESIGNATION, FAULTS. MAP FAULTS INCLUDE WIRE CHANGES,DEVICE TYPE MANUFACTURER'S DISTRIBUTORS RESIDING WITHIN 50 MILES OF FOLLOWING OPERATIONAL ATTRIBUTES;INTEGRAL MULTIPLE AMENDMENTS. SERVICE AND LOCATION OF THE CONTROL ENCLOSURE. THE PROJECT JOB SITE SHALL BE REJECTED.THESE CHANGES BY LOCATION,DEVICE ADDITIONS/DELETIONS AND DIFFERENTIAL SENSORS,AUTOMATIC DEVICE MAPPING,ELECTRONIC END-OF-LINE RESISTORS(AND VALUES)SHALL BE DEPICTED. DISTRIBUTORS MUST NOT ONLY PROVIDE INSTALLATION SUPPORT, CONVENTIONAL OPEN,SHORT,AND GROUND CONDITIONS. ADDRESSING,ENVIRONMENTAL COMPENSATION,PRE-ALARM,DIRTY 3.NATIONAL FIRE PROTECTION ASSOCIATION STANDARDS:NFPA72 BUT MUST HAVE A SERVICE ORGANIZATION CAPABLE OF 24 HOUR GROUND FAULTS ON THE CIRCUIT WIRING OF REMOTE MODULE DETECTOR IDENTIFICATION,AUTOMATIC DAY/NIGHT SENSITIVITY 4,LOCAL AND STATE BUILDING CODES AND THE LOCAL EMERGENCY CALL SERVICE AND MUST HAVE BEEN CONTRACTED SHALL BE IDENTIFIED BY DEVICE ADDRESS. ADJUSTMENT,NORMAL/ALARM LEDS,RELAY BASES,SOUNDER AUTHORITIES HAVING JURISDICTION, 10.SEE SECTION 3.4 DOCUMENTATION AND TRAINING FOR OTHER AND DELIVERED NO LESS THAN FIVE(5)ACCEPTED PROJECTS CALLOW THE USER TO DISPLAY/REPORT THE CONDITION OF BASES AND ISOLATOR BASES. ISO:ISO-9001 5.INTERNATIONAL STANDARDS ORGANIZATION DOCUMENTS RELATING TO THIS SECTION. USING THE SUBMITTED PRODUCT OVER THE PAST YEAR. ADDRESSABLE ANALOG DETECTORS. INCLUDE DEVICE ADDRESS, (ISO): I.THE SYSTEM SHALL USE FULL DIGITAL COMMUNICATIONS TO 6.UTILIZE MEA/BSA APPROVED FIRE ALARM EQUIPMENT D.ALTERNATE PRODUCT SUBMISSIONS BASED UPON USE OF A DEVICE TYPE,PERCENT OBSCURATION,AND MAINTENANCE SUPERVISE ALL ADDRESSABLE LOOP DEVICES FOR PLACEMENT, 7.THE REQUIREMENTS OF THE RYE BROOK BUILDING 11.DEVICE TYPICAL WIRING DIAGRAM DRAWINGS)SHALL BE PRODUCT LINE CONSIDERED PROPRIETARY IN ITS DISTRIBUTION, INDICATOR. THE MAINTENANCE INDICATOR SHALL PROVIDE THE CORRECT LOCATION,AND OPERATION. IT SHALL ALLOW SWAPPING PROVIDED WHICH DEPICT ALL SYSTEM COMPONENTS,AND DESIGN,APPLICATION SOFTWARE,OR ONGOING MAINTENANCE AND USER WITH A MEASURE OF CONTAMINATION OF A DEVICE UPON OF SAME TYPE DEVICES WITHOUT THE NEED OF ADDRESSING DEPARTMENT AND THE RYE BROOK FIRE THEIR RESPECTIVE FIELD WIRING TERMINATION POINTS.WIRE WHICH CLEANING DECISIONS CAN CONFIDENTLY BE MADE. 1. 10.20.2022 ISSUED FORBID&FILING DEPARTMENT. TYPE,GAUGE,AND JACKET SHALL ALSO BE INDICATED.WHEN REPAIR SHALL NOT ACCEPTABLE.PROOF OF A PRODUCT'S AND IMPOSE THE LOCATION PARAMETERS ON REPLACEMENT AN ADDRESSABLE MODULE IS USED IN MULTIPLE NON-PROPRIETARY NATURE SHALL BE THE BURDEN OF THE E.ALLOW THE USER TO REPORT HISTORY FOR ALARM, DEVICE. IT SHALL INITIATE AND MAINTAIN A TROUBLE IF A NO: DATE: REMARKS: 1.4 RELATED DOCUMENTS CONTRACTOR AT THE TIME OF BID,AND SHALL BE IN!THE FORM SUPERVISORY,MONITOR,TROUBLE,SMOKE VERIFICATION, DEVICE IS ADDED TO A LOOP AND CLEAR THE TROUBLE WHEN CONFIGURATIONS FOR MONITORING OR CONTROLLING VARIOUS OF WRITTEN DOCUMENTATION.THE DETERMINATION OF A WATCHDOG,AND RESTORE ACTIVITY. INCLUDE FACILITY NAME, THE NEW DEVICE IS MAPPED AND DEFINED INTO THE SYSTEM. TYPES OF EQUIPMENT,DIFFERENT DEVICE TYPICAL DIAGRAMS PRODUCT'S COMPLIANCE TO THIS REQUIREMENT SHALL BE LICENSEE,PROJECT PROGRAM COMPILATION DATE,COMPILER DRAWING TITLE: FIRE ALARM SPECIFICATIONS-1 SEAL&SIGNATURE: DATE: p IWI PROJECT No: DRAWN BY: DJ OF NEy �2 v CHECK'D BY:SC DWG.No.: � 9 s" FA200.00 a�FESSIO�P� FILEING TYPE I CADO FILE NO: 20F4 PROJECT: CHOPT 116 South Ridge St. Rye Brook,NY T.POWER SUPPLIES ENVIRONMENTAL COMPENSATION ALGORITHM WHICH IDENTIFIES AND SURROUNDING AIR AND INPUT AN ALARM WHEN THERE IS A (64MM)DEEP i-GANG BOXES AND i%"(38MM)DEEP INTENSITY LEVELS;15/75,15CD,30CD,75CD OR 11OCD*.LOW CONDUIT,WIRING,OUTLET BOXES,JUNCTION BOXES,CABINETS AND THE POWER SUPPLY SHALL BE A HIGH EFFICIENCY SWITCH MODE SETS AMBIENT"ENVIRONMENTAL THRESHOLDS"APPROXIMATELY CHANGE OF 65OF(350C)IN AMBIENT TEMPERATURE. SYSTEMS 4"SQUARE BOXES WITH 1-GANG COVERS. THE DUAL INPUT PROFILE STROBES SHALL MOUNT IN A NORTH AMERICAN 1-GANG SIMILAR DEVICES NECESSARY FOR THE COMPLETE INSTALLATION. ALL TYPE WITH LINE MONITORING TO AUTOMATICALLY SWITCH TO SIX TIMES AN HOUR, THE MICROPROCESSOR SHALL CONTINUALLY USING CENTRAL INTELLIGENCE FOR ALARM DECISIONS',SHALL NOT MODULE SHALL SUPPORT THE FOLLOWING CIRCUIT TYPES: BOX OR SURFACE MOUNTED ON A MATCHING BACK BOX WIRING SHALL BE OF THE TYPE RECOMMENDED BY THE BATTERIES FOR POWER FAILURE OR BROWN OUT CONDITIONS. MONITOR THE ENVIRONMENTAL IMPACT OF TEMPERATURE, BE ACCEPTABLE. THE DETECTOR SHALL CONTINUALLY MONITOR . NORMALLY-OPEN ALARM LATCHING MANUAL STATIONS,HEAT PROVIDED BY THE MANUFACTURER,AS DIRECTED IN THE FIELD. MANUFACTURER,APPROVED BY THE LOCAL FIRE DEPARTMENT AND HUMIDITY,OTHER CONTAMINATES AS WELL AS DETECTOR AGING. ANY CHANGES IN SENSITIVITY DUE TO THE ENVIRONMIENTAL ( * THE FIRE ALARM VENDOR WAY SELECT BELOW 75 CANDELA SPECIFIED WITH IN. .d E N Cj N E E R N C� THE AUTOMATIC BATTERY CHARGER SHALL HAVE LOW BATTERY THE PROCESS SHALL EMPLOY DIGITAL COMPENSATION TO ADAPT AFFECTS OF DIRT,SMOKE,TEMPERATURE,AGE AND(HUMIDITY. DETECTORS,ETC.) DISCHARGE PROTECTION. THE POWER SUPPLY SHALL PROVIDE THE DETECTOR TO BOTH 24 HOUR LONG TERM AND 4 HOUR THE INFORMATION SHALL BE STORED IN THE INTEGRAL . NORMALLY-OPEN ALARM DELAYED LATCHING(WATERFLOW WHERE ALLOWED BY THE APPROPRIATE RELEASE OF ADA. 15/75 ALL PENETRATION OF FLOOR SLABS AND FIREWALLS SHALL BE INTERNAL POWER AND 24 VDC AT 7.OA CONTINUOUS FOR SHORT TERM ENVIRONMENTAL CHANGES, THE MICROPROCESSOR PROCESSOR AND TRANSFERRED TO THE ANALOG LOOP STROBES MAY BE USED IN CORRIDORS AND IN LOCATIONS WHERE 309 Lexing�t}on Ave.,Ste.309 NOTIFICATION APPLIANCE CIRCUITS. THE POWER SUPPLY SHALL SHALL MONITOR THE ENVIRONMENTAL COMPENSATION VALUE AND CONTROLLER FOR RETRIEVAL USING A LAPTOP PC OR THE SWITCHES) 15 CANDELA IS REQUIRED PER NFPA WALL AND CEILING TABLES SLEEVED (1"CONDUIT MINIMUM)FIRE STOPPED IN ACCORDANCE b` BE CAPABLE OF PROVIDING 7A TO OUTPUT CIRCUITS FOR A ALERT THE SYSTEM OPERATOR WHEN THE DETECTOR APPROACHES • NORMALLY-OPEN ACTIVE NON-LATCHING(MONITOR,FANS, SEE NFPA 72). WITH ALL LOCAL FIRE CODES. New York,NY 10017 SIGH-PRO SIGNATURE PROGRAM/SERVICE TOOL. SEPARATELY MAXIMUM PERIOD OF 100 MS.ALL OUTPUTS SHALL BE POWER 80%AND 100%OF THE ALLOWABLE ENVIRONMENTAL MOUNTED PHOTOELECTRIC DETECTORS,IONIZATION DETECTORS DAMPERS,DOORS,ETC.) END TI LINE RESISTORS SHALL BE FURNISHED AS REQUIRED FOR 2 1 Z 687 3 0 5 0:phone LIMITED.THE BATTERY SHALL BE SIZED TO SUPPORT THE SYSTEM COMPENSATION VALUE. DIFFERENTIAL SENSING ALGORITHMS R.TEMPORAL HORN STROBES,G1RF-HDVM SERIES MOUNTING AS DIRECTED BY THE MANUFACTURER.DEVICES CONTAINING 212 687 3053 f a x FOR 24 HOURS OF SUPERVISORY AND TROUBLE SIGNAL CURRENT AND HEAT DETECTORS IN THE SAME LOCATION ARE NOT * NORMALLY-OPEN ACTIVE LATCHING(SUPERVISORY,TAMPER PROVIDE EST SERIES GiRF-HD'VM LOW PROFILE WALL MOUNT END-OF-LINE RESISTORS SHALL BE APPROPRIATELY LABELED. PLUS GENERAL ALARM FOR 15 MINUTES. 'SHALL MAINTAIN A CONSTANT DIFFERENTIAL BETWEEN SELECTED ACCEPTABLE ALTERNATIVES. THE 4D MULTISENSOR SMOKE SWITCHES) DETECTOR SENSITIVITY AND THE"LEARNED"BASE LINE DETECTOR SHALL BE RATED FOR CEILING INSTALLATION AT A HORN/STROBES AT THE LOCATIONS SHOWN ON THE DRAWINGS. DEVICES SHOULD BE LABELED SO REMOVAL OF THE DEVICE IS NOT U.AUXILIARY POWER SUPPLIES SHALL BE A HIGH EFFICIENCY SWITCH 'SENSITIVITY. THE BASE LINE SENSITIVITY INFORMATION SHALL BE MINIMUM OF 30 FT(9.1M)CENTERS AND SUITABLE FOR WALL L.WATERFLOW/TAMPER MODULE,SIGA-WTM: PROVIDE INTELLIGENT THE HORN/STROBE SHALL PROVIDE AN AUDIBLE OUTPUT OF 84.4 REQUIRED TO IDENTIFY THE EOL DEVICE. UPDATED AND PERMANENTLY STORED AT THE DETECTOR MOUNT APPLICATIONS. THE 4D MULTISENSOR SHALL BE SUITABLE WATERFLOW TAMPER MODULES SIGA-WTM.THE DBA AT 10 FT AT THE HIGH SETTING AND FOR SMALLER ROOM MODE TYPE WITH LINE MONITORING TO AUTOMATICALLY SWITCH TO APPROXIMATELY ONCE EVERY HOUR. / ALL MANUAL PULL STATIONS SHALL BE MOUNTED 48 INCHES ABOVE BATTERIES FOR POWER FAILURE OR BROWN OUT CONDITIONS. FOR DIRECT INSERTION INTO AIR DUCTS UP TO 3 FT(0.91M) WATERFLOW/TAMPER MODULE SHALL BE FACTORY SET TO SIZE LOCATIONS(AS INDICATED ON THE PLANS)A LOW DB THE FINISHED FLOOR,AS MEASURED TO THE HANDLE.ALL MANUAL THE AUTOMATIC BATTERY CHARGER SHALL HAVE LOW BATTERY THE INTELLIGENT ANALOG DETECTORS SHALL BE SUITABLE FOR HIGH AND 3 FT(0.91M)WIDE AND AIR VELOCITIES UP TO 500 SUPPORT TWO(2)SUPERVISED CLASS B INPUT CIRCUITS. SETTING(FIELD SELECTABLE)OF 79.4 DB AT 10 FT.WHEN PULL STATIONS THAT PROVIDE CENTRAL STATION CONNECTION SHALL DISCHARGE PROTECTION. THE POWER SUPPLY SHALL PROVIDE MOUNTING ON ANY SIGNATURE SERIES DETECTOR MOUNTING BASE. FT/MIN.(0-2.54 M/SEC)WITHOUT REQUIRING SPECIFIC DUCT CHANNEL A SHALL SUPPORT A NORMALLY-OPEN ALARM DELAYED MEASURED IN REVERBERATION(ROOM PER UL-464.STROBES INCLUDE A WHITE STRIP PER RYE BROOK CODE REQUIREMENTS. INTERNAL POWER AND 24 VDC AT 7.OA CONTINUOUS FOR THE FIRE ALARM SYSTEM SHALL HAVE THE ABILITY TO SET DETECTOR HOUSINGS OR SUPPLY TUBES. LATCHING WATERFLOW SWITCH CIRCUIT. CHANNEL B SHALL SHALL PROVIDE SYNCHRONIZED FLASH OUTPUTS.THE STROBE NOTIFICATION APPLIANCE CIRCUITS, THE POWER SUPPLY SHALL ELEVATOR LOBBY IONIZATION OR MULTI SENSING SMOKE SUPPORT A NORMALLY-OPEN ACTIVE LATCHING TAMPER SWITCH, OUTPUT SHALL BE AS INDICATED ON THE DRAWINGS 1N ONE OF ALL AUDIO/VISUAL DEVICES SHALL BE MOUNTED 80 INCHES ABOVE BE CAPABLE OF PROVIDING 7A TO OUTPUT CIRCUITS FOR A DETECTORS FOR ALARM VERIFICATION. DETECTOR IN THE ALARM THE WATERFLOW/TAMPER MODULE SHALL BE SUITABLE FOR THE FOLLOWING FIELD SELECTABLE INTENSITY LEVELS*;15/75, THE FINISHED FLOOR,AS MEASURED TO THE LENS.DEVICES SHALL MAXIMUM PERIOD OF 100 MS. ALL OUTPUTS SHALL BE POWER THE PERCENT SMOKE OBSCURATION PER FOOT ALARM SET PITY OINT MOUNTING ON NORTH AMERICAN 2 s„(64MM)DEEP i-GANG 15CO,30CD,75CD&110CD DEVICES.THE HORN SHALL HAVE A BE MOUNTED NO LESS THAN 6 INCHES FROM THE CEILING. VERIFICATION MODE SHALL INDICATE,BY POINT IN A TEXT FORMAT SHALL BE FIELD SELECTABLE TO ANY OF FIVE SENSITIVITY LIMITED. THE BATTERY SHALL BE SIZED TO SUPPORT THE AT THE MAIN CONTROL AND AT THE REMOTE LCD ANNUNCIATORS. SETTINGS RANGING FROM 10%TO 3.5%. THE INTEGRAL HEAT BOXES AND 1�"(38MM)DEEP 4"SQUARE BOXES WITH SELECTABLE STEADY OR SYNCHRONIZED TEMPORAL OUTPUT.LOW . SYSTEM FOR 24 HOURS OF SUPERVISORY AND TROUBLE SIGNAL 1-GANG COVERS. PROFILE HORN/STROBES SHALL MOUNT IN A NORTH AMERICAN NO AREA SMOKE DETECTORS SHALL BE MOUNTED WITHIN 36 INCHES CURRENT PLUS GENERAL ALARM FOR 15 MINUTES. C.FIXED TEMPERATURE/RATE OF RISE HEAT DETECTOR,SIGA-HRS SENSOR SHALL CAUSE AN ALARM WHEN IT SENSES A CHANGE IN 1-GANG BOX OR SURFACE MOUNTED ON A MATCHING BACK BOX OF ANY HVAC SUPPLY,RETURN AIR REGISTER OR LIGHTING FIXTURE. AMBIENT TEMPERATURE OF 650F(350C)OR REACHES IT FIXED M.SINGLE INPUT SIGNAL MODULE,SIGA-CC1 PROVIDED BY THE MANUFACTURER,AS DIRECTED IN THE FIELD. V.NETWORK ALPHA-NUMERIC ANNUNCIATORS SHALL BE LOCATED PROVIDE INTELLIGENT COMBINATION FIXED TEMPERATURE ALARM SET POINT OF 1350F(570C)NOMINAL NO AREA SMOKE OR HEAT DETECTOR SHALL BE MOUNTED WITHIN 12 THROUGHOUT THE FACILITY AS INDICATED ON THE PLANS.THE TEMPERATURE/RATE-OF-RISE HEAT DETECTORS SIGA-HRS. THE THE 4D MULTISENSOR DETECTOR SHALL BE SUITABLE FOR PROVIDE INTELLIGENT SINGLE INPUT SIGNAL MODULES SIGA-CC1 *THE FIRE ALARM VENDOR MAY SELECT BELOW 75 CANDELA INCHES OF ANY WALL.ALL DETECTORS SHALL BE INSTALLED IN SYSTEM SHALL HAVE THE CAPACITY TO SUPPORT 64 NETWORK HEAT DETECTOR SHALL HAVE A LOW MASS THERMISTOR HEAT OPERATION IN THE FOLLOWING ENVIRONMENT: FOR ACTIVATING NOTIFICATION APPLIANCE(HORN,STROBE AND WHERE ALLOWED BY THE APPROPRIATE RELEASE OF ADA. 15/75 STRICT ACCORDANCE WITH NFPA 72. ANNUNCIATORS OR EST3 NETWORK PANEL NODES. EACH SENSOR AND OPERATE AT A FIXED TEMPERATURE AND AT A HORN STROBE)CIRCUITS. THE SINGLE INPUT(SINGLE RISER STROBES MAY BE USED IN CORRIDORS AND IN LOCATIONS WHERE ANNUNCIATOR SHALL CONTAIN A SUPERVISED,BACK LIT,LIQUID TEMPERATURE RATE-OF-RISE. IT SHALL CONTINUALLY MONITOR • TEMPERATURE:320F TO 1000F(DOC TO 380C) SELECT)SIGNAL MODULE SHALL PROVIDE ONE(1)SUPERVISED 15 CANDELA IS REQUIRED PER NFPA WALL AND CEILING TABLES ALL MECHANICAL ROOMS,BOILER ROOMS,GYMNASIUMS,WIRING CRYSTAL WITH A MINIMUM OF 8 LINE WITH 21 CHARACTERS PER THE TEMPERATURE OF THE AIR IN ITS SURROUNDINGS TO • HUMIDITY:0-93%RH,NON CONDENSING CLASS B OUTPUT CIRCUIT.THE MODULE SHALL BE SUITABLE FOR (SEE NFPA 72). CLOSETS,CUSTODIAN ROOMS,ATTIC SPACES,ETC.OR AREAS WITH LINE.WHERE REQUIRED,THE ANNUNCIATOR SHALL INCLUDE MINIMIZE THERMAL LAG TO THE TIME REQUIRED TO PROCESS AN . ELEVATION:UP TO 6,000 FT(1828 M) MOUNTING ON NORTH AMERICAN 2%"(64MM)DEEP 2-GANG NO HUNG CEILINGS SHALL BE PIPED WITH 3/4"CONDUIT AND ADDITIONAL ZONAL ANNUNCIATION AND MANUAL CONTROL WITHOUT ALARM. THE INTEGRAL MICROPROCESSOR SHALL DETERMINE IF BOXES AND 1%-(38MM)DEEP 4"SQUARE BOXES WITH INSTALLED AS NECESSARY.ALL AREAS IN PUBLIC VIEW SHALL BE IN ADDITIONAL ENCLOSURES. THE ANNUNCIATOR SHALL SUPPORT AN ALARM CONDITION EXISTS AND INITIATE AN ALARM BASED ON G.STANDARD DETECTOR MOUNTING BASES,SIGA-SB SIGA-S84 2-GANG COVERS,OR EUROPEAN t00MM SQUARE BOXES. THE METAL CONDUIT. ALL BOXES MUST BE PAINTED RED AND LABELED FULL ABILITY TO SERVE AS THE OPERATING INTERFACE TO THE THE ANALYSIS OF THE DATA. SYSTEMS USING CENTRAL / S.REMOTE RELAYS "INTERIOR FIRE ALARM". SYSTEM AND SHALL INCLUDE THE FOLLOWING FEATURES; INTELLIGENCE FOR ALARM DECISIONS SHALL NOT BE ACCEPTABLE. PROVIDE STANDARD DEFECTOR MOUNTING BASES SIGANG, SINGLE INPUT SIGNAL MODULE SHALL SUPPORT THE FOLLOWING MULTI-VOLTAGE CONTROL RELAYS,MR-100 SERIES THE INTELLIGENT HEAT DETECTOR SHALL HAVE A NOMINAL FIXED SUITABLE FOR MOUNTING ON NORTH AMERICAN 1-GANG,3�"OR OPERATIONS: PROVIDE REMOTE CONTROL RELAYS CONNECTED TO SUPERVISED ALL ADDRESSABLE MODULES SHALL BE MOUNTED WITHIN 36 INCHES MATCHED APPEARANCE WITH OTHER SYSTEM DISPLAYS 4"OCTAGON BOX AND 4"SQUARE BOX. THE BASE SHALL, AUDIBLE/VISIBLE SIGNAL POWER SELECTOR(POLARIZED 24 ANCILLARY CIRCUITS FOR CONTROL OF FANS,DAMPERS,DOOR OF THE MONITORED OR CONTROLLED POINT OF TERMINATION.THIS TEMPERATURE ALARM POINT RATING OF 1350E(570C)AND A VDC®2A) RELEASES,ETC. RELAY CONTACT RATINGS SHALL BE SPDT AND EACH LCD DISPLAY ON EACH NODE(CABINET)IN THE SYSTEM CONTAIN NO ELECTRONICS,SUPPORT ALL SIGNATURE SERIES SHALL INCLUDE,BUT IS NOT NECESSARILY LIMITED TO,FAN SHALL BE CONFIGURABLE TO SHOW THE STATUS OF ANY OR ALL RATE-OF-RISE ALARM POINT OF 15OF(90C)PER MINUTE. THE DETECTOR TYPES AND HAVE THE FOLLOWING MINIMUM SHUTDOWN,ELEVATOR RECALL,SHUNT TRIP,SPRINKLER STATUS OF THE FOLLOWING FUNCTIONS ANYWHERE IN THE SYSTEM: HEAT DETECTOR SHALL BE RATED FOR CEILING INSTALLATION AT REQUIREMENTS: N.CONTROL RELAY MODULE,SIGA-CR RATED FOR 10 AMPERES AT 115 VAC.A SINGLE RELAY MAY BE POINTS OR DOOR RELEASE.LABEL ALL ADDRESSABLE MODULES AS A MINIMUM OF 70 FT(21.3M)CENTERS AND BE SUITABLE FOR ENERGIZED FROM A VOLTAGE SOURCE OF 24 VDC,24 VAC,115 TO THEIR FUNCTION. WALL MOUNT APPLICATIONS. • REMOVAL OF THE RESPECTIVE DETECTOR SHALL NOT AFFECT PROVIDE INTELLIGENT CONTROL RELAY MODULES SIGA-CR. THE VAC,OR 230 VAC.A RED LED SHALL INDICATE THE RELAY IS ALARM COMMUNICATIONS WITH OTHER DETECTORS, CONTROL RELAY MODULE SHALL PROVIDE ONE FORM"R"DRY ENERGIZED.A METAL ENCLOSURE SHALL BE PROVIDED. SUPERVISORY DJONIZATION SMOKE DETECTOR,SIGA-IS . TERMINAL CONNECTIONS SHALL BE MADE ON THE ROOM SIDE RELAY CONTACT RATED AT 2 AMPS 0 24 VDC TO CONTROL TROUBLE PROVIDE INTELLIGENT IONIZATION SMOKE DETECTORS SIGA-IS. OF THE BASE. BASES WHICH MUST BE REMOVED TO GAIN EXTERNAL APPLIANCES OR EQUIPMENT SHUTDOWN. THE CONTROL T. MULTI-VOLTAGE CONTROL RELAYS,MR-200 SERIES THE ANALOG IONIZATION DETECTOR SHALL UTILIZE A UNIPOLAR ACCESS TO THE TERMINALS SHALL NOT BE ACCEPTABLE. RELAY SHALL BE RATED FOR PILOT DUTY AND RELEASING PROVIDE REMOTE CONTROL RELAYS CONNECTED TO SUPERVISED MONITOR IONIZATION SMOKE SENSOR TO SENSE CHANGES IN AIR SAMPLES SYSTEMS. THE POSITION OF THE RELAY CONTACT SHALL BE ANCILLARY CIRCUITS FOR CONTROL OF FANS,DAMPERS,DOOR • THE BASE SHALL BE CAPABLE OF SUPPORTING ONE(1) CONFIRMED BY THE SYSTEM FIRMWARE. THE CONTROL RELAY RELEASES,ETC. RELAY CONTACT RATINGS SHALL BE DPDT AND FROM ITS SURROUNDINGS. THE INTEGRAL MICROPROCESSOR SIGNATURE SERIES SIGA-LED REMOTE ALARM LED INDICATOR. MODULE SHALL BE SUITABLE FOR MOUNTING ON NORTH RATED FOR 10 AMPERES AT 115 VAC.A SINGLE RELAY MAY BE SHALL DYNAMICALLY EXAMINE VALUES FROM THE SENSOR AND PROVIDE REMOTE LED ALARM INDICATORS WHERE SHOWN ON AMERICAN 2 h"(64MM)DEEP 1-GANG BOXES AND 1 ENERGIZED FROM A VOLTAGE SOURCE OF 24 VDC,24 VAC,115 !INITIATE AN ALARM BASED ON THE ANALYSIS OF DATA, SYSTEMS THE PLANS. W.EACH ANNUNCIATOR MUST BE CAPABLE OF SUPPORTING CUSTOM USING CENTRAL INTELLIGENCE FOR ALARM DECISIONS SHALL NOT fe"(38MM)DEEP 4"SQUARE BOXES WITH 1-GANG COVERS. VAC,OR 230 VAC.A RED LED SHALL INDICATE THE RELAY IS MESSAGES AS WELL AS SYSTEM EVENT ANNUNCIATION.IT MUST BE ACCEPTABLE. THE DETECTOR SHALL CONTINUALLY MONITOR H.DUCT DETECTOR,MODEL SIGA-SD ENERGIZED.A METAL ENCLOSURE SHALL BE PROVIDED. BE POSSIBLE TO FILTER UNWANTED ANNUNCIATION OF TROUBLE, ANY CHANGES IN SENSITIVITY DUE TO THE ENVIRONMENTAL PROVIDE MODEL SIGA-SD LOW PROFILE INTELLIGENT 0.INTELLIGENT MANUAL PULL STATIONS-GENERAL ALARM OR SUPERVISORY FUNCTIONS ON A BY POINT OR BY AFFECTS OF DIRT,SMOKE,TEMPERATURE,AGING AND HUMIDITY. ADDRESSABLE DUCT SMOKE DETECTOR AS INDICATED ON THE IT SHALL BE POSSIBLE TO ADDRESS EACH SIGNATURE SERIES U.ELECTROMAGNETIC DOORHOLDERS-GENERAL GEOGRAPHIC AREA.THE ANNUNCIATORS SHALL BE MOUNTED IN THE INFORMATION SHALL BE STORED IN THE INTEGRAL PROJECT PLANS.PROVIDE FOR VARIATIONS IN DUCT AIR VELOCITY FIRE ALARM PULL STATION WITHOUT THE USE OF DIP OR ROTARY ELECTROMAGNETIC DOORHOLDERS SUBMITTED FOR USE MUST STAND-ALONE ENCLOSURES OR INTEGRATED INTO THE NETWORK PROCESSOR AND TRANSFERRED TO THE ANALOG LOOP BETWEEN 100 AND 4,000 FEET PER MINUTE AND INCLUDE A SWITCHES. DEVICES USING DIP SWITCHES FOR ADDRESSING HAVE WRITTEN PROOF OF THEIR COMPATIBILITY FOR THE PANELS AS INDICATED ON THE PLANS. CONTROLLER FOR RETRIEVAL USING A LAPTOP PC OR THE WIDE SENSITIVITY RANGE OF.79 TO 2.46%/FT.OBSCURATION. SHALL NOT BE ACCEPTABLE. THE MANUAL STATIONS SHALL HAVE PURPOSES INTENDED. SUCH PROOF SHALL BE IN THE FORM OF SIGA-PRO SIGNATURE PROGRAM/SERVICE TOOL. THE ION INCLUDE ONE FORM-C SHUT DOWN RELAY RATED 2.,0 AMPS® A MINIMUM OF 2 DIAGNOSTIC LEDS MOUNTED ON THEIR INTEGRAL, DOCUMENTATION FROM ALL MANUFACTURERS THAT CLEARLY 2.6 COMPONENTS DETECTOR SHALL BE RATED FOR CEILING INSTALLATION AT A 30 VDC AND ALSO INCLUDE SLAVE HIGH CONTACT RELAYS IF FACTORY ASSEMBLED SINGLE OR TWO STAGE INPUT MODULE. A STATES THAT THEIR EQUIPMENT(AS SUBMITTED)IS 100% MINIMUM OF 30 FT(9.1 M)CENTERS AND BE SUITABLE FOR WALL REQUIRED. PROVIDE AN AIR EXHAUST TUBE AND AN AIR GREEN LED SHALL FLASH TO CONFIRM COMMUNICATION WITH THE COMPATIBLE WITH EACH OTHER FOR THE PURPOSES INTENDED. MOUNT APPLICATIONS. THE ION SMOKE DETECTOR SHALL BE SAMPLING INLET TUBE THAT EXTENDS INTO THE DUCT AIR STREAM LOOP CONTROLLER, A RED LED SHALL FLASH TO DISPLAY A.INTELLIGENT DEVICES--GENERAL RATED FOR OPERATION IN CONSTANT AIR VELOCITIES FROM 0 TO UP TO TEN FEET. THE ADDRESSABLE DUCT HOUSING SHALL BE ALARM STATUS. THE STATION SHALL BE CAPABLE OF STORING V.WALL MOUNTED,1504/1505/1508/1509 SERIES UP TO 24 DIAGNOSTIC CODES WHICH CAN BE RETRIEVED FOR EACH REMOTE DEVICE SHALL HAVE A MICROPROCESSOR WITH 75 FT/MIN.(0-0.38 M/SEC)AND WITH INTERMITTENT AIR GUSTS SUITABLE FOR EXTREME ENVIRONMENTS,INCLUDING A PROVIDE FLUSH,SEMI-FLUSH OR SURFACE WALL MOUNTED TROUBLESHOOTING ASSISTANCE. INPUT CIRCUIT WIRING SHALL BE NON-VOLATILE MEMORY TO SUPPORT ITS FUNCTIONALITY AND UP TO 300 FT/MIN.(1.52M/SEC)FOR UP TO 1 HOUR, TEMPERATURE RANGE OF-20 TO 158 DEGREES F(-29 TO 70 SUPERVISED FOR OPEN AND GROUND FAULTS. THE FIRE ALARM ELECTROMAGNETIC DOORHOLDER/RELEASES RATED AT 24 VAC/DC SERVICEABILITY. EACH DEVICE SHALL STORE AS REQUIRED FOR THE PERCENT SMOKE OBSCURATION PER FOOT ALARM SET POINT DEGREES CELSIUS)AND OFFER A HARSH ENVIRONMENT GASKET AS DIRECTED BY THE CONSULTING ENGINEER. FINISH SHALL BE FIVE SENSITIVITY ITS FUNCTIONALITY THE FOLLOWING DATA:DEVICE SERIAL NUMBER, PULL STATION SHALL BE SUITABLE FOR OPERATION IN THE BRUSHED ZINC. DEVICE ADDRESS,DEVICE TYPE,PERSONALITY CODE,DATE OF SHALL BE FIELD SELECTABLE TO ANY%. OPTION. PROVIDE REMOTE ALARM LED INDICATORS SIGA-LED FOLLOWING ENVIRONMENT: SETTINGS RANGING FROM THE ION DETECTOR AND/OR REMOTE TEST STATION MODEL SD-TRK AS(INDICATED ON MANUFACTURE,HOURS IN USE,TIME AND DATE OF LAST ALARM, SHALL BE SUITABLE FOR OPERATION TO 1.RATION IN IN THE FOLLOWING THE PROJECT PLANS. • TEMPERATURE:320E TO 1200E(OOC TO 490C) W.CODE CARDS AND HOLDERS: SHALL BE RED PAINTED,STEEL, AMOUNT OF ENVIRONMENTAL COMPENSATION LEFT/USED,LAST ENVIRONMENT: • HUMIDITY:0-93%RH,NON-CONDENSING FRAME CODE CARD HOLDER WITH CLEAR,ACRYLIC WINDOW AND A MAINTENANCE DATE,JOB/PROJECT NUMBER,CURRENT DETECTOR I. INTELLIGENT MODULES--GENERAL MINIMUM FIVE INCH WIDE BY EIGHT INCH HIGH(5"W.X 8"H.) SEN • TEMPERATURE:320F TO 120OF(DOC TO 490C) CODE CARD. EACH CODE CARD SHALL BE OF ADEQUATE SIZE AND ND ALGORITHMS VALUES,DIAGNOSTIC INFORMATION(TROUBLE CODES) T SHALL BE POSSIBLE TO ADDRESS EACH INTELLIGENT THE MANUAL STATION SHALL BE PAINTED WITH A ONE INCH WIDE TO LIST THE ALL THE ALARM CODES AND AREA DESCRIPTIONS A ARITHMS REQUIRED TO PROCESS SENSOR DATA AND HUMIDITY:0-93%RH,NON-CONDENSING SIGNATURE SERIES MODULE WITHOUT THE USE OF DIP OR PERFORM COMMUNICATIONS WITH THE LOOP CONTROLLER. • ELEVATION:UP TO 6,000 FT.(182B M) ROTARY SWITCHES. DEVICES USING DIP SWITCHES FOR LEFT W.)WHITE STRIPE RUNNING DIAGONALLY FROM THE UPPER SERVED BY EACH ALARM INITIATING CIRCUIT IN THE BUILDING. EACH DEVICE SHALL BE CAPABLE OF ELECTRONIC ADDRESSING, ADDRESSING SHALL NOT BE ACCEPTABLE. THE PERSONALITY OF LEFT CORNER TO THE LOWER RIGHT CORNER. PROVIDE ONE(1)CODE CARD AND HOLDER AT EACH MANUAL EITHER AUTOMATICALLY OR APPLICATION PROGRAMMED ASSIGNED, E. PHOTOELECTRIC SMOKE DETECTOR,SIGA-PS MULTIFUNCTION MODULES SHALL BE PROGRAMMABLE AT SITE TO FIRE ALARM STATION IN THE BUILDING,AT THE REMOTE TO SUPPORT PHYSICAL/ELECTRICAL MAPPING AND SUPERVISION PROVIDE INTELLIGENT PHOTOELECTRIC SMOKE DETECTORS SUIT CONDITIONS AND MAY BE CHANGED AT ANY TIME USING A MANUAL PULL STATION,SIGA-270 ANNUNCIATOR PANEL AND AT THE FACP. SIGA-PS. THE ANALOG PHOTOELECTRIC DETECTOR SHALL UTILIZE PERSONALITY CODE DOWNLOADED FROM THE ANALOG LOOP OPERATING INSTRUCTION/RISER DIAGRAM HOLDERS: SHALL BE ME LOCATION. SETTING A DEVICE'S ADDRESS BY PHYSICAL A LIGHT SCATTERING TYPE PHOTOELECTRIC SMOKE SENSOR TO CONTROLLER, MODULES REQUIRING EPROM,PROM,ROM PROVIDE INTELLIGENT SINGLE ACTION,SINGLE STAGE FIRE ALARM RED PAINTED STEEL,FRAME HOLDER WITH CLEAR,ACRYLIC MEANS SHALL NOT BE NECESSARY. SENSE CHANGES IN AIR SAMPLES FROM ITS SURROUNDINGS. CHANGES OR DIP SWITCH AND/OR JUMPER CHANGES SHALL NOT STATIONS SIGA-270. THE FIRE ALARM STATION SHALL BE OF WINDOW WITH NINE INCH BY TWELVE INCH(9"X 12") B.INTELLIGENT DETECTORS-GENERAL THE INTEGRAL MICROPROCESSOR SHALL DYNAMICALLY EXAMINE BE ACCEPTABLE. THE MODULES SHALL HAVE A MINIMUM OF 2 METAL CONSTRUCTION WITH AN INTERNAL TOGGLE SWITCH. DIMENSIONS. ONE(1)HOLDER SHALL BE PROVIDED FOR THE VALUES FROM THE SENSOR AND INITIATE AN ALARM BASED ON DIAGNOSTIC LEDS MOUNTED BEHIND A FINISHED COVER PLATE. PROVIDE A LOCKED TEST FEATURE. FINISH THE STATION IN RED FIRE ALARM CONTROL PANEL FACP SYSTEM OPERATING THE SYSTEM INTELLIGENT DETECTORS SHALL BE CAPABLE OF WITH SILVER"PULL IN CASE OF FIRE"ENGLISH LETTERING, THE )/ THE ANALYSIS CI DATA. SYSTEMS USING CENTRAL INTELLIGENCE A GREEN LED SHALL FLASH TO CONFIRM COMMUNICATION WITH FULL DIGITAL COMMUNICATIONS USING BOTH BROADCAST AND FOR ALARM DECISIONS SHALL NOT BE ACCEPTABLE. THE THE LOOP CONTROLLER, A RED LED SHALL FLASH TO DISPLAY MANUAL STATION SHALL BE SUITABLE FOR MOUNTING ON NORTH INSTRUCTIONS AND ONE(1)HOLDER SHALL BE PROVIDED FOR A POLLING PROTOCOL. EACH DETECTOR SHALL BE CAPABLE OF AMERICAN 2%-(64MM)DEEP 1-GANG BOXES AND 1 REDUCED COPY(8-1/2"X 11")OF THE FIRE ALARM SYSTEM DETECTOR SHALL CONTINUALLY MONITOR ANY CHANGES IN ALARM STATUS. THE MODULE SHALL BE CAPABLE OF STORING PERFORMING INDEPENDENT FIRE DETECTION ALGORITHMS. THE RISER DIAGRAM. THE OPERATING INSTRUCTION AND RISER SENSITIVITY DUE TO THE ENVIRONMENTAL AFFECTS OF DIRT, UP TO 24 DIAGNOSTIC CODES WHICH CAN BE RETRIEVED FOR /i"(38MM)DEEP 4"SQUARE BOXES WITH 1-GANG COVERS. FIRE DETECTION ALGORITHM SHALL MEASURE SENSOR SIGNAL DIAGRAM HOLDERS SHALL BE MOUNTED ADJACENT TO THE FIRE SMOKE,TEMPERATURE,AGING AND HUMIDITY. THE INFORMATION TROUBLESHOOTING ASSISTANCE. INPUT AND OUTPUT CIRCUIT ALL MANUAL STATIONS WHICH,WHEN ACTIVATED DIAL THE DIMENSIONS,TIME PATTERNS AND COMBINE DIFFERENT FIRE ALARM CONTROL PANEL FACP. PARAMETERS TO INCREASE RELIABILITY AND DISTINGUISH REAL SHALL BE STORED IN THE INTEGRAL PROCESSOR AND WIRING SHALL BE SUPERVISED FOR OPEN AND GROUND FAULTS. CENTRAL STATION,SHALL BE MECHANICALLY IDENTIFIED WITH A FIRE CONDITIONS FROM UNWANTED DECEPTIVE NUISANCE ALARMS. TRANSFERRED TO THE ANALOG LOOP CONTROLLER FOR RETRIEVAL THE MODULE SHALL BE SUITABLE FOR OPERATION IN THE WHITE STRIPE PER CITY OF GREENWICH CODE. Y.FIRE ALARM SYSTEM FUSED CUT-OUT: USING A LAPTOP PC OR THE SIGA-PRO SIGNATURE FOLLOWING ENVIRONMENT: SIGNAL PATTERNS THAT ARE NOT TYPICAL OF FIRES SHALL BE PROGRAM/SERVICE TOOL. THE PHOTO DETECTOR SHALL BE P.NOTIFICATION APPLIANCES-GENERAL ELIMINATED BY DIGITAL FILTERS. DEVICES NOT CAPABLE OF RATED FOR CEILING INSTALLATION AT A MINIMUM OF 30 FT • TEMPERATURE:320F TO 120OF(DOC TO 490C) ALL APPLIANCES SHALL BE UL LISTED FOR FIRE PROTECTIVE THE CONTRACTOR SHALL PROVIDE AN INDIVIDUAL CARTRIDGE NO: DATE: REVISIONS COMBINING DIFFERENT FIRE PARAMETERS OR EMPLOYING DIGITAL g 11A CENTERS AND BE SUITABLE FOR WALL MOUNT HUMIDITY:0-93%RH,NON-CONDENSING SERVICE. FUSED CUT-OUT PANEL WITH THREE(3)POLES AND A FILTERS SHALL NOT BE ACCEPTABLE. APPLICATIONS. THE PHOTOELECTRIC SMOKE DETECTOR SHALL BE J.SINGLE INPUT MODULE,SIGA-CT1 ALL STROBE APPLIANCES OR COMBINATION APPLIANCES WITH REMOVABLE,SOLID COPPER,NEUTRAL BAR IN FUSE GAP FOR EACH DETECTOR SHALL HAVE AN INTEGRAL MICROPROCESSOR SUITABLE FOR DIRECT INSERTION INTO AIR DUCTS UP TO 3 FT STROBES SHALL BE CAPABLE OF PROVIDING THE"EQUIVALENT THE FCS AND REMOTE TRANSPONDERS. CAPABLE OF MAKING ALARM DECISIONS BASED ON FIRE (0.91M)HIGH AND 3 FT(0.91M)WIDE WITH AIR VELOCITIES UP PROVIDE INTELLIGENT SINGLE INPUT MODULES SIGA-ICT1. THE FACILITATION"WHICH IS ALLOWED UNDER THE AMERICANS WITH FUSED CUT-OUTS SHALL BE PROVIDED WITH SILVER SAND FUSES, PARAMETER INFORMATION STORED IN THE DETECTOR HEAD. TO 5,000 FT/MIN.(0-25.39 M/SEC)WITHOUT REQUIRING SINGLE INPUT MODULE SHALL PROVIDE ONE(1)SUPERVISED DISABILITIES ACT ACCESSIBILITY GUIDELINES(ADA(AG)),AND SHALL CURRENT LIMITING TYPE WITH AN INTERRUPTING CAPACITY RATING DISTRIBUTED INTELLIGENCE SHALL IMPROVE RESPONSE TIME BY SPECIFIC DUCT DETECTOR HOUSINGS OR SUPPLY TUBES. CLASS B INPUT CIRCUIT CAPABLE OF A MINIMUM 4 BE UL 1971,ARRANGED PER CITY OF GREENWICH BUILDING OF 200,000 AMPS(R.M.S.SYMMETRICAL). THE SIZE OF THE DECREASING THE DATA FLOW BETWEEN DETECTOR AND ANALOG PERSONALITIES,EACH WITH A DISTINCT OPERATION.. THE MODULE 30 FUSES SHALL BE THIRTY LOOP CONTROLLER. DETECTORS NOT CAPABLE OF MAKING THE PERCENT SMOKE OBSCURATION PER FOOT ALARM SET POINT SHALL BE SUITABLE FOR MOUNTING ON NORTH AMERICAN 2 CODE. ( )AMPERES. INDEPENDENT ALARM DECISIONS SHALL NOT BE ACCEPTABLE. SHALL BE FIELD SELECTABLE TO ANY OF FIVE SENSITIVITY %"(64MM)DEEP 1-GANG BOXES AND 1%"(38MIM)DEEP ALL APPLIANCES SHALL BE OF THE SAME MANUFACTURER AS THE MAXIMUM TOTAL ANALOG LOOP RESPONSE TIME FOR DETECTORS SETTINGS RANGING FROM 1.0%TO 3.5%. THE PHOTO DETECTOR 4"SQUARE BOXES WITH 1-GANG COVERS. THE SINGLE INPUT FIRE ALARM CONTROL PANEL SPECIFIED TO INSURE ABSOLUTE CHANGING STATE SHALL BE 0.5 SECONDS. SHALL BE SUITABLE FOR OPERATION IN THE FOLLOWING MODULE SHALL SUPPORT THE FOLLOWING CIRCUIT TYPES: COMPATIBILITY BETWEEN THE APPLIANCES AND THE CONTROL THE FUSED CUT-OUT PANEL SHALL BEAR AN ENGRAVED ENVIRONMENT: PANELS,AND TO INSURE THAT THE APPLICATION OF THE WHITE-CORE PHENOLIC OR BAKELITE IDENTIFICATION NAMEPLATE MANUAL STATIONS,HEAT EACH DETECTOR SHALL HAVE A SEPARATE MEANS OF DISPLAYING NORMALLY-OPEN ALARM LATCHING STATING IN MINIMUM ONE-QUARTER INCH(1/4")HIGH WHITE ( COMMUNICATION AND ALARM STATUS. A GREEN LED SHALL + TEMPERATURE:320E TO 1200E(OOC TO 490C) APPLIANCES ARE DONE IN ACCORDANCE WITH THE SINGLE LETTERS ON A RED BACKGROUND"FIRE ALARM FUSED DETECTORS,ETC.) MANUFACTURERS'INSTRUCTIONS. FLASH TO CONFIRM COMMUNICATION WITH THE ANALOG LOOP CUT-OUT". • HUMIDITY;0-93%RH,NON-CONDENSING CONTROLLER. A RED LED SHALL FLASH TO DISPLAY ALARM • NORMALLY-OPEN ALARM DELAYED LATCHING(WATERFLOW ANY APPLIANCES WHICH DO NOT MEET THE ABOVE STATUS. • ELEVATION:NO LIMIT SWITCHES) REQUIREMENTS,AND ARE SUBMITTED FOR USE MUST SHOW THE DETECTOR SHALL BE CAPABLE OF IDENTIFYING UP TO 32 F. 4D MULTISENSOR DETECTOR,SIGA-IPHS NORMALLY-OPEN ACTIVE NON-LATCHING(MONITOR,FANS, WRITTEN PROOF OF THEIR COMPATIBILITY FOR THE PURPOSES A FOUR(4)WIRE FEEDER SHALL BRING THREE PHASE N VOLT SERVICE TO THE FUSED CUT-OUT. THE FEEDER SHALL BE B BE DIAGNOSTIC CODES. THIS INFORMATION SHALL BE AVAILABLE FOR PROVIDE INTELLIGENT 4D MULTISENSOR SMOKE DETECTORS DAMPERS,DOORS,ETC.) TENDED. SUCH PROOF SHALL BE IN THE FORM OF TAPPED OFF THE MAIN BUILDING SERVICE AHEAD OF THE MAIN SYSTEM MAINTENANCE. THE DIAGNOSTIC CODE SHALL BE STORED SIGA-IPHS. THE MULTISENSOR ANALOG DETECTOR SHALL USE A DOCUMENTATION FROM ALL MANUFACTURERS WHICH CLEARLY AT THE DETECTOR. LIGHT SCATTERING TYPE PHOTOELECTRIC SMOKE SENSOR,A NORMALLY-OPEN ACTIVE LATCHING(SUPERVISOR(,TAMPER STATES THAT THEIR EQUIPMENT(AS SUBMITTED)ARE 100% SERVICE SWITCH BUT AFTER THE CURRENT TRANSFORMERS UNIPOLAR IONIZATION SMOKE SENSOR AND AN AMBIENT SWITCHES) COMPATIBLE WITH EACH OTHER FOR THE PURPOSES INTENDED. (METERING TRANSFORMERS). EACH SMOKE DEFECTOR SHALL BE CAPABLE OF TRANSMITTING TEMPERATURE SENSOR TO SENSE CHANGES IN AIR SAMPLES K.DUAL INPUT MODULE,SIGA-CT2 PART III-EXECUTION 1. 10.202022 ISSUED FOR BID&FILING PRE-ALARM AND ALARM SIGNALS IN ADDITION TO THE NORMAL, Q.STROBES,GiRF-VM SERIES TROUBLE AND NEED CLEANING INFORMATION. IT SHALL BE FROM ITS SURROUNDINGS. THE INTEGRAL MICROPROCESSOR PROVIDE INTELLIGENT DUAL INPUT MODULES SIGA-C72. THE POSSIBLE TO PROGRAM CONTROL PANEL ACTIVITY TO EACH LEVEL. SHALL EMPLOY TIME BASED ALGORITHMS TO DYNAMICALLY PROVIDE EST SERIES HE LOCATIONS SERIES LOW PROFILE WALL 1.1 INSTALLATION NO: DATE: REMARKS: T EACH SMOKE DETECTOR MAY BE INDIVIDUALLY PROGRAMMED TO EXAMINE VALUES FROM THE THREE SENSORS SIMULTANEOUSLY DUAL INPUT MODULE SHALL PROVIDE TWO(2)SUPERVISED GLASS MOUNTED STROBES AT THE LOCATIONS SHOWN NI THE B INPUT CIRCUITS EACH CAPABLE OF A MINIMUM OF 4 AND INITIATE AN ALARM BASED ON THAT DATA THE 4D DRAWINGS. STROBES SHALL PROVIDE SYNCHRONIZED FLASH . OPERATE AT ANY ONE OF FIVE(5)SENSITIVITY SETTINGS. PERSONALITIES,EACH WITH A DISTINCT OPERATION. THE MODULE MULTISENSOR SHALL BE CAPABLE OF ADAPTING TO AMBIENT SHALL BE SUITABLE FOR MOUNTING ON NORTH AMERICAN 2�{�" OUTPUTS.STROBE OUTPUT SHALL BE FIELD SELECTABLE AS A.THE ENTIRE SYSTEM SHALL BE INSTALLED IN A WORKMANLIKE DRAWING TITLE: EACH DETECTOR MICROPROCESSOR SHALL CONTAIN AN ENVIRONMENTAL CONDITIONS. THE TEMPERATURE SENSOR SHALL INDICATED ON THE DRAWINGS IN ONE OF THE FOLLOWING MANNER,IN ACCORDANCE WITH APPROVED MANUFACTURER'S SELF-ADJUST TO THE AMBIENT TEMPERATURE OF THE WIRING DIAGRAM. THE CONTRACTOR SHALL FURNISH ALL FIRE ALARM SPECIFICATIONS-2 SEAL&SIGNATURE: DATE: 01/25/21 PROJECT No: pF NE IV DRAWN BY: DJ � a CHECK'D BY:SC DWG.No.: ark,_ y 2" FA201.00 a OFESSOA FILEING TYPE I CADO FILE NO: 30F4 PROJECT: CHOPT 116 South Ridge St. NEW DOOR HOLDERS SHALL DERIVE THEIR 24YAC/VDC POWER FROM OPERATING AND MAINTENANCE INSTRUCTION,CATALOG CUTS OF ALL Rye Brook,NY A SEPARATE POWER SUPPLY HOUSED IN A DEDICATED,METAL EQUIPMENT AND COMPONENTS,AS-BUILT WIRING DIAGRAMS AND A ENCLOSURE.THE POWER SUPPLY SHALL HAVE A 120VAC FEED,AND MANUFACTURER'S SUGGESTED SPARE PARTS LIST,AND AN END USER IS TO BE CENTRALLY LOCATED TO SERVE DOOR HOLDERS ON A TRAINING VIDEO ON DVD DISK. PER FLOOR OR AREA BASIS.ALL EXISTING DOOR HOLDERS SHALL BE CONNECTED TO NEW FACP.E.C.SHALL EXTEND ALL EXISTING IN ADDITION TO THE ABOVE MANUALS,THE ELECTRICAL CONTRACTOR f ENGINE E RN WIRING IN ORDER TO MAKE THIS WORK.LOCATIONS AND QUANTITIES SHALL PROVIDE THE SERVICES OF THE MANUFACTURER'S TRAINED 9 OF DOOR HOLDER POWER SUPPLIES SHALL BE REFERENCED AND REPRESENTATIVE FOR TWO(2)SEPARATE CALENDAR DAYS FOR A SUBMITTED IN THE SUBMISSION PACKAGE FOR APPROVAL BY THE PERIOD OF FOUR(4)HOURS PER DAY TO INSTRUCT THE OWNERS' 309 Lexington Ave.,Ste.309 CONSULTING ENGINEER. DESIGNATED PERSONNEL ON THE OPERATION AND MAINTENANCE OF ALL LOW VOLTAGE WIRING TERMINATED TO THE FIRE ALARM SYSTEM THE ENTIRE SYSTEM. New York,NY 10017 SHALL BE PLENUM RATED WITH NO EXCEPTIONS AND NO LESS AS-BUILT DRAWINGS SHALL CONSIST OF THE FOLLOWING: 212 687 3 0 5 0:phone THAN NO.12 AWG IN SIZE FOR NAC CIRCUITS AND 16 AWG FOR INITIATING CIRCUITS,AND SOLID COPPER PER.EXPOSED WIRE ABOVE COMPLETE REVISION OF ALL PREVIOUSLY SUBMITTED DRAWINGS 2 1 2 687 3053 f a x 8FT AFF SHALL BE 150 DEGREES C. POINT-TO-POINT DEPICTION OF ALL DEVICE WIRING ON THE ALL LINE VOLTAGE(120VAC)WIRING SHALL BE NO LESS THAN NO. DEVICE LAYOUT FLOOR PLANS. 12 AWG IN SIZE,AND SOLID COPPER.THIS SHALL INCLUDE ALL ONE(1)SET OF B-SIZE,LAMINATED AS-BUILT DRAWINGS. SYSTEM GROUNDING.FACP MUST HAVE A DEDICATED FUSE CUT OUT TWO(2)SETS OF 30"X42"INCH 1\16"=1'SCALE DRAWINGS ARRANGED PER RYE BROOK CODE. SHOWING ALL POINTS OF FIRE ALARM.ONE SET SHALL BE ALL WIRING SHALL BE COLOR-CODED THROUGHOUT,TO NATIONAL SUBMITTED WITH THE CLOSE-OUT DOCUMENTS.SECOND SET SHALL ELECTRICAL CODE STANDARDS. BE MOUNTED IN FRAME WITH A LEXAN COVER.THESE DRAWING POWER-LIMITED/NON-POWER-LIMITED NEC WIRING STANDARDS MUST BE SUBMITTED TO PROJECT ENGINEER OR APPROVAL. SHALL BE OBSERVED. TURNOVER OF ALL SOFTWARE DATABASE HARD/SOFT COPIES SHALL ALL JUNCTION BOX COVERS SHALL BE PAINTED RED AND LABELED BE REQUIRED.THIS SHALL INCLUDE ALL POSSIBLE PROGRAMMING SOFTWARE LOGS,DISKETTES OR CDS CONTAINING EXPORTED PROJECT INTERIOR FIRE ALARM SYSTEM. FILES,HARD COPIES OF ALL DEVICE MAPS,THE REVISION NUMBER FIRE ALARM SYSTEM WIRING SHALL NOT CO-MINGLE WITH ANY OF THE VERSION OF PROGRAMMING UTILITY USED,AND ALL REQUIRED PASSWORDS.THE TURNOVER OF ALL DATABASE INFORMATION SHALL OTHER SYSTEM WIRING IN THE FACILITY.CONDUITS SHALL NOT BE SHARED UNDER ANY CIRCUMSTANCE.ONLY WHEN FIRE ALARM OCCUR PRIOR TO THE END OF THE ONE(1)WARRANTY PERIOD(OR WIRING ENTERS THE ENCLOSURE OF A MONITORED OR CONTROLLED PERIOD AS AMENDED EARLIER IN THIS SPECIFICATION). SYSTEM WILL CO-HABITATION BE PERMITTED(I.E.AT FAN STARTERS OR ELEVATOR CONTROLLERS).THIS WILL BE FIELD INSPECTED BY THE PROJECT ENGINEER. FIRE ALARM CONTROL PANEL ENCLOSURES SHALL HAVE ENGRAVED LABELS INDICATING,"INTERIOR FIRE ALARM SYSTEM",AND THE AREAS OF THE BUILDING SERVED BY THAT PANEL. AUXILIARY RELAYS SHALL BE APPROPRIATELY LABELED TO INDICATE "FIRE ALARM SYSTEM"AND THEIR SPECIFIC FUNCTION(I.E.FAN S-1 SHUTDOWN). ALL FIRE ALARM WIRING SHALL BE CONTINUOUS AND UNSPLICED. TERMINATIONS SHALL ONLY OCCUR AT FIRE ALARM DEVICES OR CONTROL PANEL ENCLOSURES UNDER TERMINAL SCREWS.ALL OTHER SPLICING METHODS ARE SPECIFICALLY DISALLOWED(I.E. PLASTIC WIRENUTS). ALL FIRE ALARM WIRING SHALL BE INSTALLED USING A DEDICATED SYSTEM OF SUPPORTS(I.E.BRIDLE RINGS).FIRE ALARM WIRING SHALL NOT BE BUNDLED OR STRAPPED TO EXISTING CONDUIT,PIPE OR WIRE IN THE FACILITY.THIS WILL BE FIELD INSPECTED BY THE PROJECT ENGINEER, ALL FIRE ALARM WIRING SHALL BE SLEEVED WHEN PASSING THROUGH ANY WALL,USING CONDUIT SLEEVES(1"MIN.)WITH BUSHINGS,AND FIRE STOPPED IN ACCORDANCE WITH CODE. THE SYSTEM SHALL BE ARRANGED TO RECEIVE POWER FROM ONE THREE WIRE 120 VAC,20 A SUPPLY. ALL LOW VOLTAGE OPERATION SHALL BE PROVIDED FROM THE FIRE ALARM CONTROL PANEL. ALL FIRE ALARM DEVICES SHALL BE ACCESSIBLE FOR PERIODIC MAINTENANCE.SHOULD A DEVICE LOCATION INDICATED ON THE CONTRACT DRAWINGS NOT MEET THIS REQUIREMENT,IT SHALL BE THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO BRING IT, IN WRITING,TO THE ATTENTION OF THE PROJECT ENGINEER,FAILURE TO BRING SUCH ISSUES TO THE ATTENTION OF THE PROJECT ENGINEER SHALL BE THE EXCLUSIVE LIABILITY OF THE INSTALLING ELECTRICAL CONTRACTOR. THE INSTALLING ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL OF ENTIRE EXISTING FIRE ALARM SYSTEM COMPONENTS AND CONTROLS ON THE DEMOLITION DRAWING SHOWN OR NOT,UPON APPROVAL OF THE AHJ AND THE CONSULTING ENGINEER,THE END-USER RESERVES THE RIGHT TO RETAIN ANY EXISTING FIRE ALARM SYSTEM COMPONENTS,UPON THEIR REQUEST. ALL EXISTING FIRE ALARM SYSTEM COMPONENTS REQUIRING SPECIAL HANDLING FOR DISPOSAL(DUE TO RADIOACTIVITY)SHALL BE THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR.WRITTEN PROOF OF PROPER DISPOSAL BY THE INSTALLING CONTRACTOR SHALL BE REQUIRED PRIOR TO RELEASE OF OUTSTANDING RETAINAGE. 3.2 FIELD QUALITY CONTROL THE SYSTEM SHALL BE INSTALLED AND FULLY TESTED UNDER THE SUPERVISION OF A TRAINED MANUFACTURER'S REPRESENTATIVE. THE SYSTEM SHALL BE DEMONSTRATED TO PERFORM ALL OF THE FUNCTION AS SPECIFIED. THE INSTALLING CONTRACTOR OR FIRE ALARM EQUIPMENT VENDOR SHALL HAVE NO LESS THAN TWO(2)NICET LEVEL II FIRE ALARM TECHNICIANS DEDICATED TO THIS PROJECT. THE INSTALLING CONTRACT AND THE FIRE ALARM SYSTEM VENDOR SHALL,UPON THE REQUEST OF THE CONSULTING ENGINEER OR END-USER,ATTEND ANY AND ALL PROJECT MEETINGS FOR THE NO: DATE: REVISIONS PURPOSE OF ACCURATELY DETERMINING PROGRESS. IT SHALL BE THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO ASSURE THAT CONSTRUCTION DEBRIS DOES NOT ADVERSELY AFFECT ANY SENSING DEVICES INSTALLED AS PART OF THIS PROJECT.SHOULD IT BE DEEMED NECESSARY BY THE CONSULTING ENGINEER,END-USER OR AHJ,THE INSTALLING CONTRACTOR SHALL BE RESPONSIBLE FOR THE CLEANING OF ALL SMOKE DETECTORS PRIOR TO FINAL ACCEPTANCE. 3.3 TESTS THE FIRE ALARM SYSTEM VENDOR SHALL TEST THE SYSTEM IN ACCORDANCE WITH THE MANUFACTURER'S REQUIREMENTS AND NFPA 72 AS AMENDED BY THE RYE BROOK BUILDING CODE.THE VENDOR SHALL PROVIDE COMPLETED REPORTS TO THE CONSULTING ENGINEER FOR REVIEW AND APPROVAL PRIOR TO FINAL ACCEPTANCE. EACH INDIVIDUAL SYSTEM OPERATION ON A CIRCUIT-BY-CIRCUIT BASIS SHALL BE TESTED FOR ITS COMPLETE OPERATION. THE PROCEDURE FOR TESTING THE ENTIRE FIRE ALARM SYSTEM SHALL BE SET FORTH WITH THE CONSENT OF THE CODE ENFORCEMENT OFFICIAL,THE ENGINEER AND THE MANUFACTURER. 1. 10.20.2022 ISSUED FORBID&FILING NO: DATE: REMARKS: 3.4 DOCUMENTATION AND TRAINING THE CONTRACTOR SHALL COMPILE AND PROVIDE TO THE OWNERS THREE(3)COMPLETE MANUAL ON THE COMPLETED SYSTEM TO INCLUDE SITE SPECIFIC 16720-24 DRAIIING TITLE: FIRE ALARM SPECIFICATIONS-3 SEAL&SIGNATURE: DATE: PROJECT No: Of NE y DRAWN BY: DJ CNECK'D BY:SC a roL* DWG.No.: FA202.00 JF 0 pp90 �C^ A O'ESS FILEING TYPE I CADO PILE NO: 40F4