HomeMy WebLinkAboutMP23-112 DRn /JV,�VyW V �OY VILLAGE OF RYE BROOK MAYOR 938 King Street, Rye Brook,N.Y. 10573 ADMINISTRATOR Jason A. Klein (914) 939-0668 Christopher J.Bradbury www.ryebrook.org TRUSTEES BUILDING& FIRE INSPECTOR Susan R. Epstein Steven E. Fews Stephanie J. Fischer David M. Heiser Salvatore W. Morlino CERTIFICATE OF COMPLIANCE November 22,2023 Tracy Davis 44 Greenway Lane Rye Brook,New York 10573 Re: 44 Greenway Lane, Rye Brook,New York 10573 Parcel ID#: 129.84-2-33 This document certifies that the work done under Mechanical Permit #23-112 issued on 7/14/2023 for the installation of a new condenser and air handler has been satisfactorily completed. Sincerely, Steven E. Fews Building&Fire Inspector /to �E BRC�k• o`` tim 1982 BUILDING DEPARTMENT UILDING INSPECTOR ❑ASSISTANT BUILDING INSPECTOR VILLAGE OF RYE BROOK ❑CODE ENFORCEMENT OFFICER 938 King Street. Rye Brook,NY 10573 (914) 939-0668 FAx (914) 939-5801 www ryebrook.org - - - - - - - - - - - - -- -I- - - - - - INSPECTION REPORT - - - - - - - - - - - - - - - - - - - - ADDRESS : l �I �J , U � DATE: PERMIT# - , ISSUED: ` SECT: BLOCK: LOT: LOCATION: N� 1 CP �1 ' C `� OCCUPANCY: [ f ❑ Violation Noted THE WORK IS... ZPASSED ❑ FAILED /REINSPECTION ❑ SITE INSPECTION \ _ y ; REQUIRED ❑ FOOTING ❑ FOOTING DRAINAGE ❑ FOUNDATION ❑ UNDERGROUND PLUMBING NOTES ON INSPECTION: ❑ ROUGH PLUMBING ❑ ROUGH FRAMING ❑ INSULATION 1 \ 1 — ❑ Natural Gas 1 �- U `y— ❑ L.P. Gas � � A ❑ FUEL TANK ❑ FIRE SPRINKLER ❑ FINAL PLUMBING ❑ CROSS CONNECTION ❑ FINAL ❑ OTHER _ s o ■ mo h : c�' aw 4 z s N v ■ F-I Lin O u R S Q.w° � 0 w = s �© 0 W W oo ♦,,.,� a oCL a en 0 00 � o : f1 O v �. CD a « � a 0 V ►.� U W c Mr-a W �- u > ■ ON xZ z 14 � 4-, v ,° o N w 2111 uo AQ: O z a`� A u4' _ z o o � a -E.— U. a w C) � � cab BUILDI NkRTMENT D� E T E J W E VIL ' E OF RYE OOK JUL 14 2023 938 KING E,r Rv�.BR NY 10573 4 -0668`, VILLAGE OF RYE BROOK rook.ore BUILDING DEPARTMENT APPLICATION FOR PERMIT TO INSTALL AND/OR REMOVE HEATING, VENTILATION AND/OR AIR CONDITIONING EQUIPMENT FOR OFFICE USE ONLY: PERMIT#: 4 Z� Approval Date: �u Permit Fee.$ Approval Signature: Other: Disapproved: Ifecs are non-rei'undahlel *xx,r**xxxxxxxxxxxxxxxxxx�**:rvrxxxxxxxxxxxxxxxxxxxxtrxxa,�,t*x*x***,r,r�x*,rx,r*r�x,t,t*xxx�r,k,kxxrr**irrr**,k*.�x�*x** REoutRENIENTS FOR RELEASE OF PERMIT&CERTIFICATE OF COMPLI&NCE: I, Properly completed& Signed Application. 2. Site/Staging Plan if Required by the Building Inspector. 3. Copy of Licensed Contractor's Liability Insurance. (village of Rye Brook must be listed as certificate holder)&Workers Compensation Insurance on a NYS Board form(norm*C 105.2 or Form>#U26.3:or NY State workers Compensation Waiver) 4. Payment of Fees/Unit: RESIDENTIAL=$100.00/unit-COMMERCIAL=$350.00/unit. 5. Complete specifications for each unit being installed. 6. Inspection by the Building Department for removal and/or installation.(48 hour notice required) 7. Electrical work requires a separate Electrical Pen-nit&Electrical Inspection. 8. Plumbing/Gas work requires a separate Plumbing Permit& Plumbing Inspection. Application dated, Dais hereby made to the Building Inspector of the Village of Rye Brook for a permit for the installation and or removal of the HVAC equipment as listed below.The applicant and property owner,by signing this document agrees that said equipment will be installed and/or removed in conformance with all applicable Local,County,State&Federal taws, codes,rules and regulations. I. Address: 44 Greenway Lane SBL:/c3�/S7-3-33 zone: 2. Property Owner: Tracy Davis Address: 44 Greenway Lane Phone#: 646-548-8910 Cell#: 646-548-8910 email: traday590(dclmaii.eom 3. Contractor: Arctic Mechanical / Jhonny Bravo Address:460 North Main street, Port Chester, NY Phone#: 914-830-9318 Cell#: 914-830-9318 email:bravoirl_arctio-mechanical.eom 4. Scope of Work:New Installation{ )•Replacement 0-Removal( )-Other( ): 5. List Equipment: Replace old condenser and air handler with a Trane m#4TTR5036N1000A condenser and Trane m#TEM6AOC36H31SC air handler. 6. Location of Equipment: In place of respedve old units, 7. Method of Installation/Removal(list all equipment needed to perform job): t 3/3/2023 STATE OF NEW YORK,COUNTY OF WESTCHESTER ) as: Jhonny Bravo ,being duly sworn,deposes and states that he/she is the applicant above named, (print name of individual signing as the applicant) and further states that(s)he is the Heating,Ventilation and/or Air Conditioning Contractor for the legal owner and is duly authorized to make and file this application. That all statements contained herein are true to the best of his/her knowledge and belief,and that any work performed,or use conducted at the above captioned property will be in conformance with the details as set forth and contained in this application and in any accompanying approved plans and specifications,as well as in accordance with the New York State Uniform Fire Prevention&Building Code,the Code of the Village of Rye Brook and all other applicable laws,ordinances and regulations. Sworn bef re me this v ''7 Sworn to before me this `"J day ofto g 20 day of `J U 20 ,:2 �Q tgnature if Property Owner ignature o Applicant ))A VI Print ame of Pm Owne % Print ame o p t Public Public ==mber s cticut pires 4 This application must be properly completed in its entirety and must include the notarized signature(s) of the legal owner(s) of the subject property, and the applicant of record in the spaces provided. Any application not properly completed in its entirety and/or not properly signed shall be deemed null and void and will be returned to the applicant. 2 3/3/2023 STATE OF NEW YORK,COUNTY OF WESTCHESTER ) as: Ik o n n X $r qV t8 ,being duly sworn,deposes and states that he/she is the applicant above named, (print name of�d vidual signing as the applicant) and further states that(s)he is the Heating,Ventilation and/or Air Conditioning Contractor for the legal owner and is duly authorized to make and file this application. That all statements contained herein are true to the best of his/her knowledge and belief,and that any work performed,or use conducted at the above captioned property will be in conformance with the details as set forth and contained in this application and in any accompanying approved plans and specifications,as well as in accordance with the New York State Uniform Fire Prevention&Building Code,the Code of the Village of Rye Brook and all other applicable laws,ordinances and regulations. Sworn to before me this Sworn to before me this day of 20 day of-31X 20 Signature of Property Owner Signature of Applicant Print Name of Property Owner Print Na e of Applicant Lk-IAdli, Notary Public ry Pub is Una Whalen Notary Public,State of New York No.01 WH6394580 Qualified in Westchester County Commission Expires July 8,20£3 This application must be properly completed in its entirety and must include the notarized signature(s) of the legal owner(s) of the subject property, and the applicant of record in the spaces provided. Any application not properly completed in its entirety and/or not properly signed shall be deemed null and void and will be returned to the applicant. 2 3/3/2023 P (ool (alc Project Name: 44 Greenway Lane Address: 44 Greenway Lane,Rye Brook,NY OUTDOOR DESIGN CONDITIONS Weather station White Plains,Westchester Co.AP Summer Outdoor F: Summer Indoor F: 0i Design Grains: ® Daily Ranger Winter Outdoor F: e Winter Indoor F: i Cooling RH: Elevation(Ft): LOAD CALCULATION TOTALS HVAC System:44 Greenway Lane Heated square footage: 0 Heating BTUH: 0 Cooled square footage: Cooling BTUH: Heated volume(above grade CF): 0 CFM: Cooled volume(above grade CF): Sensible cooling: Exposed wall area(SF): Latent cooling: SHR: Load Calculation Cooking Heat rig 0 10,000 20,000 30,000 40,000 BTUH Approved ACCA MJ8 Calculations Calculations are based on the ACCA Manual J 8th Edition and are approved by ACCA. All computed calculations are estimates on building use, weather data, and inputted values such a R-Values, window types, duct loss, etc. Equipment selections should meet both the latent and sensible gain as well as building heat loss. HEATING AND COOLING LOADS HEATING LOADS Heating Loads aboveGradeWalls 1,756.6 D ceilings 859.2 ducts 0 No data floors 850.3 infiltration 0 skylights 0 windows 432 Totals COOLING LOADS Cooling Loads SECTION AREA SENSIBLE LATENT aboveGradeWalls AbUExcursion 0 0 0 appliances aboveGradeWalls 1,756.6 4,106 0 vr)dows appliances 0 3,400 0 PA ceilings ceilings 859.2 1,632 0 plants ducts ducts 0 3,094 204 floors 850.3 0 0 occupants infiltration infiltration 0 1,784 2,140 occupants 0 690 600 plants 0 0 300 skylights 0 0 0 windows 432 14,244 0 Totals 28.951 3.245 FENESTRATION LOADS AED Graph(mid-summer) 20,000 2 �? 10.000 no 0 8 9 10 11 12 13 14 15 16 17 18 19 — BTUH —Average ---- Average 1.3 This graph represents hourly aggregrate fenestration bads in mid-summer. AED graph(fall) 20,000 10,000 Ca 0 8 9 10 11 12 13 14 15 16 17 18 19 — BTUH —Average ----- Average'1.3 This graph represents hourly aggregrate fenestration bads in October. COMPONENT LOADS ABOVE Map trace was Frame Wall,Wood framing, R-11 cavity Construction nr 12B-Os w Exposure N Healing BTUH 0 insulation,Stucco or Siding. U Value: 0.097 Area: 90.5 Cooling BTUH: 212 Map trace was Frame Wall,Wood framing,R-11 cavity Construction nr 12B-Os w Exposure: NE Heating BTUH: 0 insulation,Stucco or Siding. U Value 0.097 Area: 81.1 Cooling BTUH 190 Map trace was Frame Wall,Wood framing, R-11 cavity Construction nr 128-Os w Exposure: SE Healing BTUH 0 insulation,Stucco or Siding. U Value: 0.097 Area: 89.1 Cooling BTUH: 208 Map trace was Frame Wall,Wood framing, R-11 cavity Construction nr: 128-Os w Exposure: SE Heating BTUH: 0 insulation, Stucco or Siding. U Value: 0.097 Area: 190.2 Cooling BTUH: 445 Map trace was Frame Wall.Wood framing, R-11 cavity Construction nr. 12B-Os w Exposure: S Heating BTUH 0 insulation, Stucco or Siding. U Value: 0.097 Area: 24.3 Cooling BTUH: 57 Map trace was Frame Wall,Wood framing, R-11 cavity Construction nr 12B-Os w Exposure: SW Heating BTUH: 0 insulation, Stucco or Siding. U Value: 0.097 Area: 162.1 Cooling BTUH: 379 Map trace was Frame Wall,Wood framing, R-11 cavity Construction nr: 12B-Os w Exposure: NW Heating BTUH: 0 insulation, Stucco or Siding. U Value: 0.097 Area: 269.2 Coding BTUH: 629 Map trace was Frame Wall,Wood framing,R-11 cavity Construction nr 12B-Os w Exposure: NW Heating BTUH: 0 insulation, Stucco or Siding. U Value: 0.097 Aroa: 19 Coding BTUH: 44 Map trace was Frame Wall,Wood framing, R-11 cavity Construction nr: 128-Os w Exposure: NE Heating BTUH: 0 insulation, Stucco or Siding. U Value: 0.097 Area: 134.1 Coding BTUH: 313 Map trace wall Frame Wall,Wood framing,R-11 cavity Construction nr. 12B-Os w Exposure: SE Heating BTUH: 0 insulation,Stucco or Siding. U Value: 0.097 Area: 268.8 Cooling BTUH: 628 Map trace was Frame Wall,Wood framing, R-11 cavity Construction nr: 128-Os w Exposure: S Heating BTUH: 0 insulation, Stucco or Siding. U Value: 0.097 Area: 159 Coding BTUH: 372 Map trace wall Frame Wall,Wood framing,R-11 cavity Constructon nr 128-Os w Exposure NW Heating BTUH 0 insulation,Stucco or Siding. U Value: 0.097 Area: 269.2 Coding BTUH: 629 BELOW There are no components for this section. Default small windows for wall id 5136984 Construction nr 1 G U Value: O.87 Heating BTUH: 0 Window,NFRC rated,Clear glass. Exposure N SHGC 0.67 Cooling BTUH: 242 Default medium windows for wall id 5136984 Construction nr 1G U Value 0.87 Healing BTUH. 0 Window,NFRC rated,Clear glass. Area: 12 e: N SHGC 0.67 Coding BTUH: 242 ExposurDefault small windows for wall id 5136982 Construction nr 1 G U Value: 0.87 Heating BTUH* 0 Window, NFRC rated,Clear glass. Exposure: NE SHGC 0.67 Cooling BTUH: 149 Default medium windows for wall id 5136982 Construction nr: 1G U Value: 0.87 Heating BTUH: 0 Window,NFRC rated,Clear glass. Areposure NE 12 SHGC 0.67 Cooling BTUH 299 Default small windows for wall id 5136985 Construction nr iG U Value: 0.87 Heating BTUH: 0 Window, NFRC rated,Clear glass. Area: 12Exposure: SE SHGC 0.67 Coding BTUH: 487 Default medium windows for wall id 513698S Construction nr 1 G U Value: 0.87 Heating BTUH 0 Window, NFRC rated,Clear glass. Area: 12Exposure: SE SHGC: 0.67 Coding BTUH: 487 Default small windows for wall id 5136987 Construction nr 1 G 12 U Value: 0.87 Heating BTUH: 0 Window, NFRC rated,Clear glass. Exposure: SE SHGC: 0.67 Coding BTUH: 487 Default medium windows for well!Id 5136987 Construction nr: 1 G U Value: 0.67 Heating BTUH: 0 Window, NFRC rated,Clear glass. Area: 36 Exposure: SE SHGC 0.67 Coding BTUH: 1,460 Default small windows for wall Id 5136986 Construction nr: 1 G U Value: 0.87 Heating BTUH: 0 Window, NFRC rated, Clear glass. Area S SHGC: 0.67 Coding BTUH: 219 Default smal windows for wap id 5138M Construction nr 1 G U Value: 0.87 Heating BTUH. 0 Window, NFRC rated,Clear glass. Exposure: 12 SHGC: 0.67 Cooling BTUH: 512 Sw Default medium windows for wal Id 5136988 Construction nr 1 G U Value: 0.87 Heating BTUH: 0 Window,NFRC rated,Clear glass. Exposure 24 SHGC 0.67 Coding BTUH: 1,023 Default small windows for wall id 5136981 Construction nr 1G U Value: 0.87 Heating BTUH 0 Window, NrtZU rated, Clear glass. Exposure: 6 SHGC 0.67 Coding BTUH: 171 Default medium windows for wal id 513MI Construction nr. 1 G U Value: 0.87 Heating BTUH: 0 Window, NFRC rated,Clear glass. Exposure: NW SHGC 0.67 Coding BTUH: 682 Default large windows for wall id 5136981 Construction nr 1G U Value: 0.87 Healing BTUH: 0 Window,NFRC rated,Clear glass. Areposure: 336 SHGC: 0.67 Coding BTUH: 1,023 NW Default small windows for wall id 5136M Construction nr. 1 G U Value: 0.87 Heating BTUH: 0 Window, NFRC rated,Clear glass. Area:sure: NW SHGC. 0.67 Cooling BTUH: 171 ExpoDefault small!windows for wall Id 51369M Construction nr: 1 G U Value: 0.87 Heating BTUH: 0 Window, NFRC rated,Clear glass. Area: 12 SHGC. 0.67 Cooling BTUH: 286 Exposure: NE Default medium windows for wall id 5136990 Construction nr 1G Area: 24 U Value: 0.87 Heating BTUH: 0 Window, NFRC rated,Clear glass. Exposure: NE SHGC 0.67 Cooling BTUH: 585 Default small windows for wall id 5136991 Construction nr. 1 G U Value: 0.87 Healing BTUH: 0 Window,NFRC rated,Clear glass. Exposure: 2 SHGC 0.67 Cooling BTUH: 460 Default medium windows for wall id 5136991 Construction nr I U Value: 0.87 Heating BTUH 0 Window, NFRC rated,Clear glass. Area: 12 Exposure: SE SHGC 0.67 Coding BTUH: 473 Default large windows for wall id 5136991 Construction nr 1 G U Value: 0.87 Healing BTUH: 0 Window. NFRC rated. Clear glass. Area: 36 Exposure SE SHGC 0.67 Coding BTUH: 1.433 Default small windows for wall id 5136992 Construction nr: 1 G U Value. 0.87 Heating BTUH. 0 Window. NFRC fated.Clear glaSS. Area:sure: g SHGC' 0.67 Coding BTUH: 213 ExpoDefault medium windows for wall id 5136992 Construction nr. 1 G U Value: 0.87 Heating BTUH: 0 Window, NFRC rated,Clear glass. Exposure: S SHGC 0.67 Coding BTUH: 1,295 Default small windows for wall id 5136989 Construction nr 1G Area- 6 U Value 0.87 Heating BTUH 0 Window, NFRC rated,Clear glass. Exposure: NW SHGC 0.67 Cooling BTUH: 165 Default medium windows for wall id 5136989 Construction nr I U Value: 0.87 Heating BTUH 0 Window, NFRC rated,Clear glass. Area: posure: NW SHGC 0.67 Cooling BTUH: 671 Defatit large wlndews for wall id$130999 Construction nr 1 G U Value: 0.87 Heating BTUH 0 Window,NFRC rated,Clear glass. Area: 36 SHGC 0.67 Cooling BTUH 1.012 Fxp,,,,­ NW Window cooling BTUHs shown here are daily average values.See AED graphs for details of fenestration loads during the day. Map trace generated ceiling Ceiling under attic or attic knee wall.Asphalt Construction nr 16B-25 ad Area: 82.5 Heating BTUH 0 shingles, Dark. R-25. ding BTUH: 157 Map trace generated ceiling Ceiling under attic or attic knee wall,Asphalt Construction nr 16B-25 ad Area: 17.7 Heating BTUH 0 shingles, Dark, R-25. U Value: 0.038 Cooling BTUH: 34 Map trace generated ce" Ceiling under attic or attic knee wall,Asphalt Construction nr. 16B-25 ad Heating BTUH 0 shingles, Dark, R-25. U Value 0.038 Area: 759 Coding BTUH: 1,442 There are no components for this section. Skylight cooling BTUHs shown here are daily average values.See AED graphs for details of fenestration loads during the day. •ee' There are no components for this section. Map trace generated floor Concrete slab on grade floor, R-10 slab Construction nr 22C-10ph Heating U Value:0 Heating BTUH 0 Area. 850.3 Coding U Value 0 Cooling BTUH: 0 insulation. F Value: 1.221 VENTILATION There are no components for this section. HOT WATER PIPING There are no components for this section. System generated ducts(above conditioned space) EHLF 0.098 Heating BTUH: 0 Attic-Radial ESGF. 0.12 Sensible BTUH. 3,094 ELG 204 Latent BTUH: 204 INFILTRATION NCFM Heating: 186 Heating BTUH: 0 Leakage Category: Semi-Loose NCFM Cooling 97 Sensible BTUH: 1,784 Latent BTUH: 2,140 BLOWER • • There are no components for this section. HUMIDIFICATIONWINTER There are no components for this section. OCCUPANTS Nr.Occupants 3 Sensible BTUH 690 Latent BTUH 600 APPLIANCES Kitchen,utility room.additional fridge.lighting:3,400 BTUH Quantity Sensible BTUH 3,400 Latent BTUH. Plant Size: small Queninv 5 Latent BTUH 50 Plant Size: medium Quantity: 5 Latent BTUH: 100 Plant Size: large Quantity. 5 Latent BTUH: 150 ROOM DETAIL Room name:First floor Heated square footage: 0 Total Cooling BTUH: Cooled square footage: Total Heating BTUH: 0 Heated volume(above grade CF): © CFM: Cooled volume(above grade CF): Exposed wall area(SF): Load Calculation Cooling Heating 0 5,000 10,000 15,000 BTUH AED Graph(mid-summer) 10.000 2 5,000 m 0 8 9 10 11 12 13 14 15 16 17 18 19 — BTUH —Average — Average 1.3 AED graph(fall) 10,000 2 5,000 cc 0 8 9 10 11 12 13 14 15 16 17 18 19 — BTUH —Average --- Average'1.3 ROOM DETAIL Room name:Second Floor Heated square footage: 0 Total Cooling BTUH: Cooled square footage: Total Heating BTUH: 0 Heated volume(above grade CF): 0 CFM: Cooled volume(above grade CF): IVIRM Exposed wall area(SF): Load Calculation Cooling Heating 0 5.000 10,000 15,000 BTUH AED Graph(mid-summer) 10.000 2 5,000 co 0 8 9 10 11 12 13 14 15 16 17 18 19 — BTUH —Average — Average 1.3 AED graph(fall) 10,000 2 ti 5,000 co 0 8 9 10 11 12 13 14 15 16 17 18 19 — BTUH — Average -- Average'1.3 TRANE' Product Data Convertible Air Handlers 1-1/2 — 5 Ton TEM6AOB24H21 SC TEM6AOB3OH21 SC TEM6AOC36H31 SC e TEM6AOC42H41 SC TEM6AOC48H41SC TEM6BOC6OH51 SA D U o O The TEM6 series air handler is designed for installation in a closet, utility room,alcove,basement,crawlspace or attic. These versatile units are applicable to air conditioning and heat pump applications.Several models are available to meet the specific requirements of the outdoor equipment.Field installed electric resistance heaters are available. 1 March 2022 22-1907-1 K-EN N = T E C H N O L O G i . , 0 7MWE* Product Specifications MODEL TEM6A0B24H21SC TEM6AOB3OH21SC TEM6AOC36H31SC RATED VOLTS/PH/HZ 208-230/1/60 208-230/1/60 208-230/1/60 RATINGSW See O.D.Specifications See O.D.Spedfications See O.D.Specifications INDOOR COIL—Type Plate Fin Plate Fin Plate Fin Rows—F.P.I. 4-14 4-14 4-14 Face Area(sq.ft.) 3.44 3.44 4.59 Tube Size(In.) 3/8 3/8 3/8 Refrigerant Control TXV TXV TXV Drain Conn.Size(in.)(b) 3/4 NPT 3/4 NPT 3/4 NPT DUCT CONNECTIONS See Outline Drawing See Outline Drawing See Outline Drawing INDOOR FAN—Type Centrifugal Centrifugal Centrifugal Diameter-Width(In.) 11 X 8 11 X 8 11 X 8 No.Used i 1 1 Drive-No.Speeds Direct-16 Direct-16 Direct-16 CFM vs.in.w.g. See Fan Performance Table See Fan Performance Table See Fan Performance Table No.Motors—H.P. 1-1/3 1-112 1-112 Motor Speed R.P.M. Variable Variable Variable Volts/Ph/Hz 208-23D/1/60 208-230/1/60 208-230/1/60 F.L.Amps 2.5 4.3 4.3 FILTER Filter Furnished?W No No No REFRIGERANT R-410A R-410A R-410A Ref.Line Connections Brazed Brazed Brazed Coupling or Conn.Size—in.Gas 3/4 3/4 7/8 Coupling or Conn.Size—in.Uq. 3/8 3/8 3/8 DIMENSIONS HxWxD HxWxD HxWxD Crated(In.) 48-1/4 x 22-1/2 x 25-1/2 48-1/4 x 22-1/2 x 25-1/2 52-3/4 x 27-1/2 x 25-1/2 Uncrated 46-3/4 x 18-1/2 x 21-1/8 46-3/4 x 18-1/2 x 21-1/8 51-3/8 x 23-112 x 21-1/8 WEIGHT Shipping(Lbs.)/Net(Lbs.) 126/117 126/117 155/144 0) These Air Handlers are A.H.R.I certified with various Split System Air Conditioners and Heat Pumps(AHRI STANDARD 210/240).Refer to the Split System Outdoor Unit Product Data Guides for performance data. W 3/4"Male Plastic Pipe(Ref:ASTM 1785-76) «) Remote filter required. 4 22-1907-1 K-EN s N3-)I I-LO6I-ZZ 6uyyas ilnepa luopej toy £817 b6b 88V E9b OZV SAeM 330 NO 330 d30 u01 H9IH 6VET OSVT SEST S09T 6S91 WAD /W3J ETb E64 b917 9ZV 08E SZ£ SueM 3d0 330 3j0 330 uoI "� b SS£i ZTbT 9SVT 69bT TTST WAD /W3J SL£ 1VW210N OLb STb SSE 66Z 6EZ STTe/yI NO 330 330 330 uoT MO1 60ET 9EEi ESET T9ET 09ET WAD /W3J SEE b6b 19b OZb ZLE 9TE STTe%/1 j30 NO dd0 NO u04 H9IH 9S£T 80K 6bbT still L60T WAD /W3J SZb Ttb Sib SSE OOE ObZ Sue%A 330 jj0 dj0 NO u01 ltlW2ION S'£ OTET LEFT VSEI 79ET 19ET WAD /WdJ 98£ SSE 9EE S8Z ZEZ OST SueM NO 330 330 NO u0T MO-1bLiT OOZT 9IZi bZZT ZZZI W3J /W3J"C 009 Zbb £8£ EZE 09Z sTTeM dd0 NO NO dd0 uoT HJIH LSET bBET TOUT 60Vi 60K WAD /WdJ 99b TZb 89E VTE 6SZ VOZ sUeM 330 jj0 NO d30 u01 IVWMON £ SZZT SSZT ZLZT 6LZT LLZI WAD /WdJ bZb ESE EOE ESZ £OZ vs sueM NO 330 NO 330 uoa MO-1 £ZIT TVTI 6bTT LOTT WAD /W3JI8£ 80£ 6SZ ZTZ 99T ZZT STjeM 330 NO NO NO u0I HOIH 096 STOT 9EOT 9VOT ZbOT WAD /W3J LIb 69Z bZZ OST SET 86 Suem 330 d30 NO NO u04 1tlW210N S'Z ZS8 906 LE6 ES6 6K WAD /W3J 6LE ZEZ E6T bSI SIT LL SpeM NO 330 NO NO u0T MOl LOL 88L 8E8 E98 098 WdJ /WA0IbE 6'0 co S'O E'0 T'o 219MOd bMS EMS ZMS TMS 9NI113S 9NI119S (SNO1) MO13211V MOl3aIV O33dS 3ZIS)INn 3,dnSS321d JI1V1S 1VNIJ X3 9NI113S H31IMS dIO 2I000 Lno V31V314 ON'a311Id ON'3ONVWIi031b3d MO1JbIV 9NI1V3H 9STb14Zt,3OV9W31'OST£H9£3OV9W31 OOUewJoJJad MOy JId '9 elgel 6uillaS Tlnelap Ajo»ej e 884 £8b 99b 901 E6E SI;e/✓+ dd0 NO 330 d30 uoT H91H 9ZET 90VT ELbT sZSI OLSI WAD /W3J 06£ LTS Z9b bob bb£ Z8Z SITeM d30 330 0 330 uoT e> 60£I $LET 86EI OTb 33 T ZIbT WAD /W3J OSE 1VW'dON b SOB LSE 90E £SZ 661 STTeM NO 330 330 330 u04 MOl ZBTT OIZT 6ZZT 8£ZT 8EZT WAD /W3J HE 9TS Z9b 90b LVE 99Z STTeM jj0 NO j30 NO uoT H9IH 817ET 6LET IObi SIbT BTbT WAD /WdJ ZOb TZb 69E LTE E9Z 60Z STTeM 3j0 330 330 NO uol ltlW2fON S'£ TOZT 6ZZT 8bZT 8SZ1 8SZT WAD /W3J LSE EVE £6Z SbZ L61 OST SaTeM NO 3d0 330 NO uoT MOl 6EOT ZLOT V601 SOTT VOTT WAD /W3J Si£ bob ESE TOE 6bZ 96T SueM d30 NO NO d30 uoT H9IH SLIT EOZT IZZT TEZT TEZT WAD /WjJ gob LEE 88Z OVZ Z61 9bi STTeM 3d0 d30 NO d30 uoT 1tlWaON E 9ZOT 090T Z801 £60T Z60T WAD /W3J E9£ 6LZ £EZ 681 ZVT 90T SITeM NO j30 NO jj0 uoI MOl Z98 bT6 LV6 Z96 T96 WAD /W3J 6TE 6LZ b£Z 061 ZVI 90T SueM 330 NO NO NO u01 H9IH £99 ST6 806 E96 Z96 WAD /W3J b8E S£Z 96T 8ST OZI Z8 S»eM dd0 dd0 NO NO uaT 1VW2ION S'Z OOL T8L b£8 T98 Z98 WAD /WADIbE E61 E91 TET 86 £9 ST;eM NO 330 NO NO uaT MOl 09S VS9 61L SSL T91 WAD /W3J 00£ 6'0 L'O S'O E'O T'0 "d3MOd VMS EMS ZMS TMS (SNOl) 9N1113S 9NI113S 3ZIS lIN(I 3?Jf1S53ad J[1tl1S lVN i31X3 MOl3i1IV 9NI113S HJ1IM5 dIO MO l3NIV O33dS MOOOlIln H31V3H ON'1011Id ON'1IOJ 13M'3JNVWTiO=lH3d MO1daIV E)NI1009 7STVHZbJOV9W31'OST£H9£90V9W31 aauewJOIJad MOU HIV 'S elgel e;ea leoijI3913 pue G3UewJ0P8d .BUURK 0 TRAAE' Performance and Electrical Data Table 11. Electrical Data TEM6AOC36H31SC,TEM6AOC42H41SC HEATER DATA 240 Volt 208 Volt No.of Capacity Heater Minimum Maximum Capacity Heater Model No. Circuits/ Ca P P y Heater Minimum Maximum Phases Amps per Circuit Overload Amps per Circuit Overload kW BTUH Circuit Ampacity Protection kW BTUH Circuit Ampacity Protection No Heater 4.3* 5 15 4.3' 5 15 BAYHTR1504BRK 1/1 3.84 13100 16.0 25 25 2.88 9800 13.8 23 25 BAYHTR1504LUG BAYHTR15058RK 1/1 4.80 16400 20.0 30 30 3.60 12300 17.3 27 30 BAYHTR1505LUG BAYHTR1508BRK 1/1 7.68 26200 32.0 45 45 5.76 19700 27.7 40 40 BAYHTR1508LUG BAYHTR1510BRK 1/1 9.60 32800 40.0 55 60 7.20 24600 34.6 49 50 BAYHTR151OLUG BAYHTR1517BRK Circuit 1 0) 9.60 32800 40.0 55 60 7.20 24600 34.6 49 50 211 BAYHTR1517BRK 4.80 16400 20.0 25 25 3.60 12300 17.3 22 25 Circuit 2 BAYH BRK Circuit it 1 1(a(a) 9.60 32800 40.0 55 60 7.20 24600 34.6 49 50 ) 211 BA 236RK Circuitcuit 2 9.60 32800 40.0 s0 50 7.20 24600 34.6 43 45 2 BAYHTR351OLUG 1 1/3 1 9.60 1328001 23.1 34 35 7.20 24600 20.0 30 30 BAYHTR3517LUG 1 1/3 1 14.40 1491001 34.6 48 50 10.80 36900 30.0 42 45 *=Motor Amps (a) MCA and MOP for circuit 1 contains the motor amps 12 22-1907-1 K-EN TRANE Minimum Airflow CFM TEM6AOB24H21SC,TEM6AOB3OH21SC Heater Minimum Heater Airflow CFM With Heat Pump Without Heat Pump BAYHTR15046RK,BAYHTR1504LUG BAYHTR1505BRK,BAYHTR1505LUG 660 600 BAYHTR1508BRK,BAYHTR1508LUG 780 600 BAYHTR1510BRK,BAYHTR1510LUG 780 600 BAYHTR1517BRK 1050 850 BAYHTR351OLUG 780 600 BAYHTR3517LUG 900 850 TEM6AOC36H31SC,TEM6AOC42H41SC Heater Minimum Heater Airflow CFM With Heat Pump Without Heat Pump BAYHTR1504BRK,BAYHTR1504LUG BAYHTR1505BRK,BAYHTR1505LUG 875 675 BAYHTR1508BRK,BAYHTR1508LUG 950 820 BAYHTR1510BRK,BAYHTR151OLUG 1000 820 BAYHTR1517BRK 1000 820 BAYHTR351OLUG 875 820 BAYHTR3517LUG 1000 950 BAYHTR1523BRK 1300 1140 TEM6AOC48H41SC,TEM6BOC60HS1SA Heater Minimum Heater Airflow CFM With Heat Pump Without Heat Pump BAYHTR1504BRK,BAYHTR15D4LUG 1200 975 BAYHTR1505BRK,BAYHTR1505LUG BAYHTR1508BRK,BAYHTR1508LUG 1350 975 BAYHTR1510BRK,BAYHTR1510LUG 1350 975 BAYHTR1517BRK 1365 975 BAYHTR351OLUG 1300 975 BAYHTR3517LUG 1365 1120 BAYHTR1523BRK 1365 1300 BAYHTR1525BRK 1810 1505 14 22-1907-1 K-E N MAW' Minimum Airflow CFM TEM6AOB24H21SC,TEM6A0B30H21SC Airflow Performance with Auxiliary Heat Dip Switch Settings Airflow Settings Nominal Airflow Switch 7 Switch 8 See following tables for heater application: Low ON ON 601 Pressure Drop for Electrical Heaters Med-Lo OFF ON 661 Minimum Heating Airflow Matrix on unit Med-Hi ON OFF 781 nameplates) High OFF OFF 973 TEM6AOC36H31SC,TEM6AOC42H41SC Airflow Performance with Auxiliary Heat Dip Switch Settings Airflow Settings Nominal Airflow Switch 7 Switch 8 See following tables for heater application: Low ON ON 696 Pressure Drop for Electrical Heaters Med-Lo OFF ON 825 Minimum Heating Airflow Matrix on unit Med-Hi ON OFF 1150 nameplates) High OFF OFF 1298 TEM6AOC48H41SC,TEM6BOC60HS1SA Airflow Performance with Auxiliary Heat Dip Switch Settings Airflow Settings Nominal Airflow Switch 7 Switch 8 See following tables for heater application: Low ON ON 1000 -Pressure Drop for Electrical Heaters Med-Lo OFF ON 1130 -Minimum Heating Airflow Matrix(on unit Med-Hi ON OFF 1354 nameplates) High OFF OFF 1596 22-1907-1 K-EN t 5 0 7MME Electrical Data � c a � g< aW sat IS ( ` = aoi � s m a� u- '' a,,,• � �F e"ess Y�oF 3 v g= iy£u W NEW , .� is TO a aaleu o, t 31041 33S r i N I x 1 IA HIIA + vC 11d 10 If A Y 191 n i 1 u II X : s�Eel- =i1 $ cc x U 7TY an 11nd1er� 1111n 111a nus OWd 01 18 22-1907-1 K-E N TRAWE Field Wiring Single Stage, Cooling Only Thermostat Air Handler Outdoor Unit 24 VAC HOT [D - - - -[R - i i FAN [D i i i 24VAC - - - -� ' - � Common i SOV I lJ r J 1sst STAGE COOL/HEAT ly 1 r - ry u i i YZ HEATING 2nd STAGE W 1 Whrtc EMERGENCY HEAT L WVhVite BK 1. * Units with pigtails require wirenuts for connections. 2, Cap all unused wires. 3, For BK enabled comfort control, do not connect Y1 or Y2 at the air handler 4. For BK enabled comfort control, cut the jumper wire between R and BK on the control board. See wiring schematic for details. 5. In AC systems for multiple stages of electric heat,jumper W1 and W2 together if comfort control has only one stage of heat. 22-1907-1 K-EN 17 7WAIIFE. Field Wiring 2 Stage, 2 Step, Cooling Only Thermostat Air Handler Outdoor Unit 24 VAC HOT - - - -[R:l - i FAN E - - - -I' G � i i i Common 16D , i i J SsOtSTAGETEq - - - - Y1 - - - - 19 Y2 - - - - YZ - - - - Y2 HEATING 2nd STAGE W 1 Wh�tc EMERGENCY HEAT White B KK 1. * Units with pigtails require wirenuts for connections. 2. Cap all unused wires. 3. For BK enabled comfort control, do not connect Y1 or Y2 at the air handler 4. For BK enabled comfort control, cut the jumper wire between R and BK on the control board. See wiring schematic for details. 5. In AC systems for multiple stages of electric heat,jumper W1 and W2 together if comfort control has only one stage of heat. 22-1907-1 K-EN is TRANE' TEM Convertibility Figure 1. Multi-Position Air Handler *=No Internal Modifications Required. 0 O D rO o U � O O 0 0 O Refrigerant Connections Downflow ® Condensate � Drains O O a Upflow 0 Condensate 0 a Drains 0 Vertical Upflow* Vertical Downflow 00 C 0 Airflow 00 O O Horizontal Left Refrigerant Horizontal Right Condensate Connections Condensate Drains Drains Horizontal Left* Horizontal Right 22-1907-1 K-EN 21 TREWE° TEM6 Air Handler Dimensional Data vV �I o � o o � � 0 0 0 o O ti 0 lb D Model No. H W p TEM6AOB24H21SC 45.02 18.50 21.13 TEM6AOB3OH21SC 45.02 18.50 21.13 TEM6AOC36H31SC 51.27 23.50 21.13 TEM6AOC42H41SC 51.27 23.50 21.13 TEM6AOC48H41SC 57.40 23.50 21.13 TEM6BOC60HS1SA 57.40 23.50 21.13 22 22-1907-1K-EN 0 TRWE' Outline Drawing ii It MINIMUM UNIT QEAIANCE TABLE SENYICE „ I ECOMMENCE NECOeTMENDEDI SIDES 1' IMONT zI BACK 0' INLET DUCT I' OUTLET DUCT NIA B C NOTE:"UNIT 0 APPROVED FOR NOTALLATION CLEARAMM TO OONMUSYN"MATERIAL AS 0 t« !TINTED ON THE FAIR RATING RAMEPI ATE :se ALL 09001W AFE REFB*NM OffieUM Lee mL la 2It e Se ;,rt ® aE s f 5.« mt ee I� - i' a �I o eon, O i, In I.rS O O La t.LEs O M � 0 I 5 is L Li 11 D — — PRODUCT DIMENSIONS Air Handler Model A B C D E F H Flow Gas Line Control Braze TEM6AOB24,30 46.77 18.50 16.50 16.75 4.68 7.33 20.09 TXV 3/4 TEM6AOC36,42 51.27 23.50 21.50 21.75 7.01 9.66 24.59 TXV 7/8 TEM6AOC48/ 57.40 23.50 21.50 21.75 4.68 9.66 27.19 TXV 7/8 TEM6BOC60 All dimensions are in Inches 22-1907-1 K-EN 23 0 TRAHE' Product Data Split System Cooling 4TTR5018N1000A 4TTR5024N1000A 4TTR503ON1000A - 4TTR5036N1000A 4TTR5042N1000A "'"' 4TTR5048N1000A = 4TTR506ON1000A Note:"Graphics in this document are for representation only.Actual model may differ in appearance." .July 2022 22-1970-1 A-EN 1 -� A N = TECHN0L0GI_5' 0 7MME' Product Specifications Model No.W 4TTR5018N1000A 4TTR5024NIO00A 4TTR5030N1000A 4TTR5036NIO00A POWER CONNS.-V/PH/HZ(b) 208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60 MIN.BRCH.CIR.AMPACITY 12 13 17 18 BR.CIR.PROT.RTG.-MAX.(AMPS) 20 25 25 30 COMPRESSOR CLIMATUFF@-SCROLL CLIMATUFFO-SCROLL CLIMATUFFV-SCROLL CLIMATUFF@)-SCROLL RL AMPS-LR AMPS 9-47.5 10.1-52 12.8-67.8 13.6-79 Outdoor Fan FL AMPS 0.64 0.64 0.64 0.77 Fan HP 1/8 1/8 1/8 1/8 Fan Dla(Inches) 23.02 23.02 23.02 24 Coil SPINE FIN- SPINE FINTM SPINE FIN- SPINE FIN- Refrigerant R-410A 4 LBS.,15 OZ 4 LBS.,11 OZ 5 LBS.,8 OZ 6 LBS.,8 OZ VALVE CONNECTION SIZE-IN.O.D.GAS 3/4 3/4 3/4 3/4 VALVE CONNECTION SIZE-IN.O.D.LIQ. 3/8 3/8 3/8 3/8 LINE SIZE-IN.O.D.GAS to 3/4 3/4 3/4 7/8 LINE SIZE-IN.O.D.LIQ. 3/8 3/8 3/8 3/8 Charge Spec.Subcooling 8°F 80F 8°F 8°F Dimensions H x W X D Crated(IN.) 34 x 30.1 x 33 34 x 30.1 x 33 42 x 30.1 x 33 42 x 35.1 x 38.7 Weight-Shipping(lbs.) 189 190 220 246 Weight-Net(lbs.) 161 162 184 212 Optional Accessories: Anti-short Cycle Timer TAYASCT501A TAYASCT501A TAYASCT501A TAYASCTSOIA Evaporator Defrost Control AY28X079 AY28X079 AY28X079 AY28X079 Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 BAYISLT101 Extreme Condition Mount Kit BAYECMT023 BAYECMT023 BAYECMT023 BAYECMT004 Start Kit BAYKSKT263 BAYKSKT263 BAYKSKT263 BAYKSKT263 Crankcase Heater Kit BAYCCHT302 BAYCCHT302 BAYCCHT302 BAYCCHT302 Seacoast Kit BAYSEAC001 BAYSEAC001 BAYSEAC001 BAYSEAC001 Low Ambient Kit BAYLOAM 103 BAYLOAM 103 BAYLOAM 103 BAYLOAM 103 Service Valve Panel Cover TAYSVPANL0032AA TAYSVPANL0032AA TAYSVPANL0044AA TAYSVPANL0044AA Refrigerant Lineset tat W Certified in accordance with the Unitary Air-conditioner equipment certification program which Is based on AHRI standard 210/240. (b) Calculated in accordance with N.E.C.Only use HACR circuit breakers or fuses. (0 Standard line lengths-60',Standard lift-60'Suction and Liquid line.For Greater lengths and lifts refer to refrigerant piping software P0432-3312-0' ('denotes latest revision). (d) 25,30,35 and 50 foot linesets available.For a complete listing of lineset options available from equipment or supply stores,refer to the Trane Residential and Light Commercial Product Handbook. 2 22-1970-1A-EN MANE Sound Power Level Sound Power Level A-Weighted MODEL Sound Power Full Octave Sound Power(dB) Level[dB(A)] 63 Hz" 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 8000Hz Hz 4TFR5018N 73 79 69 67 70 70 64 59 53 4TTRSD24N 73 79 69 67 70 70 64 59 53 4TTR503ON 73 79 69 67 70 70 64 59 53 4TTR5036N 71 78 72 69 68 66 61 58 53 4TTR5042N 72 81 75 71 70 68 63 58 53 4TTR5048N 72 81 75 71 70 68 63 58 53 4TTR5060N 71 81 75 71 70 68 63 58 53 Note:Rated in accordance with AHRI Standard 270-2008*For Reference Only 4 22-1970-1 A-E N — — rJMME Accessory Description and Usage Anti-Short Cycle Timer— Solid state timing device that prevents compressor recycling until five(5)minutes have elapsed after satisfying call or power interruptions.Use in area with questionable power delivery,commercial applications,long lineset,etc. Evaporation Defrost Control — SPST Temperature actuated switch that cycles the condenser off as indoor coil reaches freeze-up conditions.Used for low ambient cooling to 30°F with TXV. Rubber Isolators— Five(5)large rubber donuts to isolate condensing unit from transmitting energy into mounting frame or pad. Use on any application where sound transmission needs to be minimized. Hard Start Kit— Start capacitor and relay to assist compressor motor startup.Use in areas with marginal power supply,on long linesets, low ambient conditions,etc. Extreme Condition Mount Kit— Bracket kits to securely mount condensing unit to a frame or pad without removing any panels.Use in areas with high winds,or on commercial roof tops,etc. AHRI Standard Capacity Rating Conditions AHRI Standard 210/240 Rating Conditions 1. Cooling 80'F DB,67°F WB air entering indoor coil,95°F DB air entering outdoor coil. 2. High Temperature Heating 47QF DB,43°F WB air entering outdoor coil,70°F DB air entering indoor coil. 3. Low Temperature Heating 17°F DB air entering indoor coil. 4. Rated indoor airflow for heating is the same as for cooling. AHRI Standard 270 Rating Conditions — (Noise rating numbers are determiend with the unit in cooling operations.)Standard Noise Rating number is at 95°F outdoor air. Model Nomenclature Outdoor Units 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 4 T W V 0 0 3 6 A 1 0 0 0 A A Refngeranl Type 2=R-22 4=R-110A TRANE Product Type W=Spilt Heat Pump T-Split Cooling Product Family V=Variable Speed M or B=Basic Z=Leadership-Two Stage A=Light Commercial X=Leadership L=Side Discharge R=ReplacemenVRelail Family SEER 3=13 6=16 0=20 4=14 8=18 5=15 9=19 Split System Connections 1.6 Tons 0=Brazed Nominal Capacity in 000s of BTUs Major Design Modifications Power Supply 1=200-2300160 or 2 0 8-2 3 01116 0 3=200.23013/60 4=4600160 Secondary Function Minor Design Modifications Unit Parts Identifier 22-1970-1 A-E N 5 0 TRWE' Schematic Diagrams Figure 1. 018N—048N Models TO POWER SUPPLY PER UNIT NAMEPLATE AND LOCAL CODES 1 � ¢-----! d SEE PRODUCT DATAFOR OPTIONAL START KIT ACCESSORY - m '• i M, I GCS CSR-I CSR I coo!z ------ RD-----------L4/ f�BR - a---BK/BL---- MS-2 CJ1 1 RD— - -- - -- -- r -- - _ BK/BL CAPACITOR _ 1 FAN APR OR�CR MTR ©K F C H R IGL CPR THERMALLY R D co PROTECTED INTERNALLY � LEGEND TYPICAL HPCO LPCO I TYPICAL I cF rAN CAP"'. A I R HANDLER I THERMOSTAT CN MIRECONNECTOR I b o CPR COMPRCSSOR 0 1 I CR RUN CAPACITOR CS STARTING CAPACITOR Y I Q I I CSR CAPACITOR SNITCHING RELAY u F INDOOR FAN RELAY Y I Y I + O I "RED NIGH PRESSURE CUTOUT Sui[N '� LPCO LON PRESSURE CRIOUT SR17CN IOL INIERRAL OVERLOAD PRO1EC70R B L Y o I SM SYSTEM ON OrF SNITCH 1 - - MS COMPRESSOR MOTOR CONTACTOR NOTES 1&2 I ODA OUTDOOR ANTICIPATOR 1 - - -- �- I W HEAT OFT OUTDOOR TAM 7NTRMDSTAi 101 TIONAL( I NENOTEI 1 CONTROLS' 1 ODS OU7p0oR tE YPC PAIURE SENSOR ODT./B1/�{] X2 I DDT OU DOOR rHERNOS7AT v ]`-U K- - - -1+ --'�_ W� Sc SNITCH OVCR VALVE SOLEN010 _ B K J I L ( INS "ANSTORMEpINF 7N[RMOSTAI ODT-A (OPTIONAL i 1 0-- W I �-COLOR OE HIRE j- o-BK--- - BK/8L i I I ----COLOR OF MARI[R -- ---B K-- ---- -- -1 I (\_ I MR 01 BLUE RIAC. P RED R DRUG[ M M PI YL YELLOW P: 1. LP E�PIN LTRL LISHT SUE _ I IOR CAMADIAY IMSTALLAIIOMS B L '� POUR INSTALLAT10R5 CANADICNNES aB ?NS CAUTION: NOT SUITABLE FOR USE JA 24V STSTEMSEACEEDING (SOY-TO-OROJ��\\ AE TENTI0INE CONVENT PAS AUA —— — -R D T J NS TALI ATI0N5 DE PLUS DE ISO V LA TE RRC I TO POWER SUPPLY PER LOCAL CODES ————L• - . .—-— PRINFED FROM DI57362PO8 REVA L_ 6 22-1970-1 A-E N ram' Schematic Diagrams Figure 2. 018N—048N Models VOTES: /--� LPCO HPCO I. IF OOT-8 IS NOT USED. ADD JUMPFR BETWEEN C \\ — - p K F A N W2 A W3 AT AIR. HANDLER IF USED, ODT-D K BL IOL 1 MUST BE MOUNTED REMOTE Or CONTROL B01t IN OR r_ B R MT R AN APPROVED WEATHER PROOF ENCLOSURE. RD S R / o p THE RMALLI PROTECtED 2. IF ODTA IS NOT USED. ADD JUMPER BETWEEN WEER C PR r WI A W2 AT AIR HANDLER. -- INTF RNALL 3. LOW VOL7AGE !2A V) FIELD WIRING MUST OE 18 AWG MIN - -'--- "—- - - - - ' -—- LEGEND 2A V 1 FACTORY L NE yJ NIR ING I 2A V 1 FIFLD L'RE9!MIRING T,FLD INSTALLED ----- FACTOR,WIRING _ MAGNETIC COIL -L GROUND CAPACITOR JUNCTION -jF- CAPACITOR r � � ���� • �� 1 1 1 F Z:1 WIRE NUT OR TERMINAL + 1 J TRANSFORMER 1 1 I j i 1 1 �r FUSE 1 1 1 F^ TERMINAL BLOCK/BOARD I 1 R L 1 1 �F RELAY C04TACI 49.0) RELAY CONIACI i%-C) I 1 1 1 1 i THERMISTOR 'SEE PRODUCT 1 1 1 DATA FOR 1 I 1 TEMP ACTUATED SWITCH (OPTIONAL START 1 1 1 I KIT AC r: '.'IR j_j 1 1 1 T-0 INTERNAL OVI RL OAC PRO T[C 110N I���+�r �t--------------J I 1 CT—PRESSURE ACTUATED SWITCH ; I ; I ; 1 RESISTER OR HEA7ING ELEMENT RD� 0--0 MOTOR WINDING i.1- '.'SR� i I a -. I !YL 1 POI..PL UG FENALF HOUSING I 1 ' R 3�(MALE TERMINALS) � W r� POE, PL U6 MALE HOUSING ¢ R 3 IFE MALE TERMINALS) LJ 11 ZJ ' 13 m m -- � -BK ---�I----BK Xz I I NOTES IF2 _ (I�.•,T 1 IOPI ZONAL I B o-RL RO i(I L OOT-B 1 �? K B K I �Y 1 OD&t IIOPTIONALI i -- -I B'K ---------' 1 ----------- --------- - - PRINTED FROM D157362PO8 REVA ; --------- - --- _�WL70 POWER SOPPLY PER —_— _JI{OMIT NAODE ATES AMD LOCAL CODES 22-1970-1 A-EN 7 rmwE Outline Drawing B L i C SERVICE PANEL ELECTRICAL AND WRIGERANT CW►ONENT CLURAMCES PER PREVAILING CODES. TOP DISCHARGE AREA SHOULD Of UNRESTRICTED To AT LEAST 1521 IS TEE"ABOVE 14.1. LIMIT SHOULD BE PLACED$0 ROOT RUN-OFF WATER DOES 40T POUR DIRECTLY ON UNIT, AND SHOULD BE AT LUST 305 112'I FROM BALL AND ALL SURROUNDING SHRUBBERY ON TOO SIDES. OTHER 110 SIDES UNRESTRICTED. r- ELECTRICAL SERVICE PANEL K is n I A 22.2 17181 DIA, INR[ LOU vOI TAGE 28.6 11-1181 DIA. 1.0. •IT 22.2 11181 DIA. WILE IN CONTROL 001 BOTTOM FOR ELECTRICAL 'I POSER SUPPLY H F K.O. 101 ALTERNATE O ELEC IRICAL ROUTING UOU1D LINE SERVICE VALVE. 'f' I.D. FEMALE BRAZE CONNECTION 11TH III'SAf GAS LINE 114 TURN BALL BE1VICf VALVE. '0' FLARE PRESSURE RAP fl RINGS. I.D. FEMALE BRAZED COW[C T100 11 TN vA'SAE FLARE PRESSURE TAP FITTING. Model Base A B C 0 E F G H 3 K 4TTR5018N 3 730 829 756 3/4 3/8 127 76 197 60 508 (28-3/4) (32-5/8) (29-3/4) (5) (3) (7-3/4) (2-3/8) (20) 4TTR5024N 3 730 829 756 3/4 3/8 127 76 197 60 508 (28-3/4) (32-5/8) (29-3/4) (5) (3) (7-3/4) (2-3/8) (20) 4TTR5030N 3 933 829 756 3/4 3/8 143 92 210 79 508 (36-3/4) (32-5/8) (29-3/4) (5-5/8) (3-5/8) (8-1/4) (3-1/8) (20) 4TTR5036N q 943 946 870 3/4 3/8 143 98 219 86 508 (37-1/8) (37-1/4) (34-1/4) (5-5/8) (3-7/8) (8-5/8) (3-3/8) (20) 4TTR5042N 4 1147 946 870 7/8 3/8 152 98 219 86 813 (45-1/8) (37-1/4) (34-1/4) (6) (3-7/8) (8-5/8) (3-3/8) (32) 4TTR5048N 4 1147 946 870 7/8 3/8 152 98 219 86 813 (45-1/8) (37-1/4) (34-1/4) (6) (3-7/8) (8-5/8) (3-3/8) (32) 4TTR5060N 4 1147 946 870 7/8 3/8 152 98 219 86 813 (45-1/8) (37-1/4) (34-1/4) (6) (3-7/8) (8-5/8) (3-3/8) (32) 10 22-1970-1 A-E N � �1�rt , (frS{�,,J�A !µ �� �j ��A�� J f�A� M � Y �.. _ 4..CA 1S � �• '. • 1I r a4. (1�1{� �irl i�1/ ,fir e�I,t h. •+ ! f1+1 � ' Y, �_' N �{ a 4C.�+.+. �t Nl,+� f= r. s _+!.�4 1!= ,1/{ �;e vs��•�,1,/ {:n.� t o)i`� _ .s �.....� ._ris-_:�...._._L. .: ._�•_sue.__ ' g v � e C cm sew � ar ••ice > 4. C a y v W (D .� Anit �c. LLI :� }'•` A U z o '� oectionaA», L _ f !_�•� RP _ Lu v p O LLJ H C + ^ z L R SC • i � Ld C 'v � T 1• ��� CS LO 00 ---�- ,�+ !i � 17��--•-.:;--• '(71+'-"i���?3'l``'^� Pr i � ti <(o)► 2 `#E41.' '! +1{•1 .!F#i"k ! .!I�+I+II,ifs o p 4.`• � :!1�{I'/++i! 'i3. 1'• !it�l{'1'+iJ �yj*( 11, '1 �ia. /i{�/ 5... • •, : a ° a . {i •aat /1� 1+1 I J! � a ti '%• �'dICV+'. IWv�fFi v�i v `:.:.5. r.. .�' '�. a -r f.\1• v�C� •',�i., J,✓.• �- "��-� �r'• saew't :�I, ` •r• � •.ti •Y'',� 'v'Y 'tip pfv r Ir v �~ +yf• r;`Y. \.__ice �_ _ �. _.. I - .>x.:c•,``^�" ,����` 1 It), 'a�oRo CERTIFICATE OF LIABILITY INSURANCE 712/15 NYYYI 2o22 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such erxlorsement s. PRODUCER CONTANAME:CT CLIENT CONTACT CENTER - FEDERATED MUTUAL INSURANCE COMPANY -- HOME OFFICE: P.O.BOX 328 A/CNE.No Eid:888-333-4949 Nc No):507-4464664 ONVATONNA,MN 55060 ADMDRESS:CLIENTCONTA TCENTER(tbFEDINS.COM INSURERS)AFFORDING COVERAGE _ NAW# INSURER A:FEDERATED MUTUAL INSURANCE COMPANY 13935 INSURED 286-468.-4 INSURER e:FEDERATED RESERVE INSURANCE COMPANY 16024 ARCTIC MECHANICAL INCORPORATED INSURER C: 460 N MAIN ST PORT CHESTER, NY 10573-3310 INSURER D: INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER:90 REVISION NUMBER:0 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE DL SUBR POLICY NUMBER POLICY EFF POLICY EXP LTR INSR WVD MMIDDIYYYY M IDDIYYY LIMITS X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $1,000,000 CLAIMS-MADE DX OCCUR DAMAGE TOPREMISES LRENT D a —_— $100,000 MED EXP(Any one person( EXCLUDED A N N 9907993 01/18/2023 01/18/2024 PERSONAL B ADV INJURY $1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $jr OQO 0W X PRO POLICY U JECT 71 LOC PRODUCTS-COMPIOP AGO $2,000,000 (OTHER AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT a agadent $1,000,000 X ANY AUTO BODILY INJURY(Per person) OWNED AUTOS ONLY SCHEDULED A AUTOS N N 9907993 01/18/2023 01/18/2024 BODILY INJURY(Per accident) HIRED AUTOS ONLY NON-OWNED AUTOSONLY PROPERTY DAMAGE UTO$ (Per accident) X UMBRELLA LIAB X OCCUR EACH OCCURRENCE $5,000,000 A EXCESS LIAB CLAIMS-MADE N N 9907994 01/18/2023 01/18/2024 AGGREGATE $5,000,000 DEO I X!RETENTION S10,000 WORKERS COMPENSATION AND EMPLOYERS'LIABILITY X PER STATUTE O R YIN ER ANY PRO PR IETORI PART NE R/EXECUTIVE D E.L.EACH ACCIDENT $1,000,000 B OFFICER/MEMBER EXCLUDED? NIA N 9298530 01/18/2023 01/18/2024 (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $1,000,000 17 yes,describe under DESCRIPTION OF OPERATIONS below E.L DISEASE-POLICY LIMIT $1,000,000 DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES(ACORD 101,Additional Remarks Schelde,may be attached if more space is requiredl CERTIFICATE HOLDER CANCELLATION 286-468-4 90 0 VILLAGE OF RYE BROOK SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 938 KING ST THE EXPIRATION DATE THEREOF. NOTICE WILL BE DELIVERED IN RYE BROOK, NY 10573-1226 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE O 1988-2015 ACORD CORPORATION.All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD NEW Workers' YYRK TA E Compensation CERTIFICATE OF Board NYS WORKERS' COMPENSATION INSURANCE COVERAGE 1a.Legal Name&Address of Insured(use street address only) 1 b. Business Telephone Number of Insured ARCTIC MECHANICAL INCORPORATED 914-934-8301 460 N MAIN ST PORT CHESTER,NY 10573-3310 tc NYS Unemployment Insurance Employer Registration Number of Insured Work Location of Insured(Only required if coverage is specifically limited to 1 d. Federal Employer Identification Number of Insured or Social Security certain locations in New York State,i.e.,a Wrap-Up Policy) Number 06-1596446 2.Name and Address of Entity Requesting Proof of Coverage 3a Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) Federated Reserve Insurance Company Village of Rye Brook #90 3b Policy Number of Entity Listed in Box"I a" 9298530 938 King St Rye Brook, NY 10573-1226 3c.Policy effective period 01/18/2023 to 01/18/2024 3d The Proprietor, Partners or Executive Officers are Kincluded.(Only check box if all partners/officers included) ❑ all excluded or certain partners/officers excluded This certifies that the insurance carrier indicated above In box"3"Insures the business referenced above In box"1a"for workers' compensation under the New York State Workers'Compensation Law. (To use this form, New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate (These notices may be sent by regular mail.)Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent, or until the policy expiration date listed in box"3c",whichever is earlier. This certificate is issued as a matter of information only and confers no rights upon the certificate holder. This certificate does not amend. extend or alter the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond those contained In the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note: Upon cancellation of the workers'compensation policy indicated on this form, if the business continues to be named on a permit, license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury, I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by. Jean Newkirk (Print name of authortzed representative or licensed agent of insurance carrier) Approved by: (Signature) (bate) Title AUTHORIZED REPRESENTATIVE Telephone Number of authorized representative or licensed agent of insurance carrier: 888-333-4949 Please Note: Only insurance carriers and their licensed agents are authorized to issue Form C-105.2. Insurance brokers are NOT authorized to issue it. C-105.2 (9-17) www.wcb.ny.gov