HomeMy WebLinkAboutElevator Compliance Notice 2022-11-16 SEP 3 0 2024 VILLAGE OF RYE BROOK BUILDING DEPARTMENT Hudson Valley Elevation Consultants, Inc. 40 East Main Stieet,Suite 207 P O Box 804 Washingtormile,NY 10992 (845)614-56% Compliance Notice September 26, 2024 Ms_ Alena Hakanjin, Property Manager Win Ridge Realty, LLC 24 Rye Ridge Plaza Rye Brook, NY 10573 RE- Plaza Building 10 & Plaza Building 14 2 Hydraulic Elevators NYS QEI Elevator Inspection Dear Ms. Hakanjin, This is your letter of compliance certifying that on September 25, 2024, the elevators located at the referenced address underwent the NYS mandate Category-1 Q E.I. inspection test, in coordination with your elevator maintenance company, Champion Elevator. The elevators were found to be in good working order and returned to service. The elevators are in compliance as per NYS IBC 3000.1, PM 606.1, and ANSUASME A17.1-3 Codes. This concludes our test/inspection for the year 2024. Yours sincerely, Louis Giovannetti, Chief Inspector QEI #C-59441 NYSBOC #00099770 1 NYS LIC,132-22-06034 Hudson Valley Elevation Consultants, Inc. 90 East Man Street,Sune 207 ?0.Bm 804 WeshNIor 9e,NY 10992 (W)6145856 Compliance Notice November 16, 2022 Ms, Alena Hakanjin, Property Manager Win Ridge Realty, LLC 24 Rye Ridge Plaza Rye Brook, NY 10573 RE, Plaza Building 10 & Plaza Building 14 2 Hydraulic Elevators NYS QEI Elevator Inspection Dear Ms. Hakanjin, This is your letter of compliance certifying that the elevators located at the referenced address underwent the NYS mandate Category-1 Q.E.I. inspection test, in coordination with your elevator maintenance company, Champion Elevator. The violations noted during the initial inspection date of September 28, 2022, have been remedied. The elevators are now in compliance as of this date. This inspection test has been conducted according to NYS IBC 3000.1, PM 606.1, and ANSVASME A17.1-3 Codes. This concludes our testfinspection for the year 2022. Yours sincerely, Louis Giovannetti, Chief Inspector - — QEI #C-5944, New York State CEO # 00099770 - - iJ Hudson Valley Elevation Consultants, Inc. 90 East Mein Street Suite 207 P O.Flux 004 Wash'nptormile,NY 10992 (545)61 a-5656 VIOLATION NOTICE September 29, 2022 Ms. Alena Hakanjin, Property Manager Win Ridge Realty, LLC 24 Rye Ridge Plaza Rye Brook, NY 10573 RE: Plaza Building 10 & Plaza Building 14 2 Hydraulic Elevators NYS QEI Elevator Inspection Dear Ms. Hakanjin, The NYS mandated Q.E.I. Inspection/Test, with a complete test of the smoke recall system, was performed in coordination with Champion Elevator and the buildings contracted Alarm Company on September 28, 2022. The elevators located at the referenced address were found to contain violations and unsatisfactory conditions as listed below: Plaza Building 10 1. Render the smoke recall system operational to the NFPA 72 code. The fire hat in the cab shall be flashing when a smoke condition is detected in the hoistway and machine room and full on for all other detectors outside the hoistway and machine room. Page i of 2 2. Render the smoke hatch to open automatically when the hoistway smoke detector is activated to allow the smoke to be vented out. Plaza Building 14 1. Render the car door electronic safety edge to be inoperative when in fire service phase 1 and 2 mode. ( the car door shall be allowed to keep closing when in fire service) 2. Provide a shunt trip system to be activated by the machine room heat detector. 3. Render the smoke hatch to open automatically when the hoistway smoke detector is activated to allow the smoke to be vented out. 4. Render the smoke recall system operational to the NFPA 72 code. The elevator does not respond to the proper floors and alternate floor. Also the fire hat bezel does not light up when in fire service. It shall be necessary to perform a re-inspection when all of the above listed violations/deficiencies are removed. Have your elevator maintenance company and alarm company present for the smoke recall test to be performed during this re- inspection. As that we are not an enforcement agent, we can only bring to your attention the deficiencies or violations found during our tesVnspection of your elevator as of September 28, 2022. it is your responsibility to remedy such deficiencies and or violations in the set required 30 day allotment. Notify this office when the above has been taken care of, so we can perform a re-inspection and issue a violation clearance letter. This Test/Inspection is in accordance with NYS IBC Section 3000.1 PM 606.1 and the ANSI/ASME Al7.1- 3 Safety Code for Elevators and Escalators. Sincerely, Louis Giovannetti, Chief Inspector Q.E.I. #C-5944, NYSBOC # 0009970 NYS Elevator License#132-22-06034 Page 2 of 2