HomeMy WebLinkAboutElevator Inspection 2.2021 "El Aul AES�`A Certified C-875 <NAESA Sincel993 Certified Elevator Ins ee J�' 2 6 Z01� CertificdC-875 i ons Inc, Since 1993 7-11 Legion brive. Suite 103. Valhalla. ICY 10595 • Phone: 914 428-3419 Fax: 914 428-3501 • johneeiCa'optonline.net January 26,2021 1100 King Street Associates C/O George Comfort& Sons, Inc. 4 International Drive Rye Brook,NY 10573 Attn: Larry Christ Re: 1100 King Street,Annual Elevator Inspections-Rye Brook New York Dear Sir: On January 22 & 23 2021 I witnessed the code required annual no load hydraulic pressure and safety tests on twelve(12)passenger elevators located at the above referenced address as performed by your elevator maintenance company Liberty Elevator Corp. The elevators were tested to ensure compliance with testing procedures required by ASME A17.1 Safety Code for Elevators and Escalators as referenced by the NYS Building Code, Chapter30 The following violations were revealed that require correction to comply with code: Building#I Elevators# 1&2 1. When cars are on fire recall Phase I and return to lobby the fire buzzers must turn off. 2. Fire recall lights must remain on during Phase I and II operation. Elevator#2 1. Replace 2 missing car platen plate bolts Building#2 Elevator# 1 Fire recall lights must remain on during Phase I and I1 operation and buzzers must turn off. Elevator#2 1. Car does not recall on Phase I 2. Control valve relief is set at 600psi; it must be set to approximately 450 Psi 3. Fire recall lights must remain on during Phase I and II operation. Building#3 Elevators#1 &2 1. When cars on fire recall phase I and return to lobby the fire buzzers must turn off and fire lights must stay on. Elevator#2 1. In-car emergency Phone does not work. 2. Replace broken emergency light lens. "A aul Certified C-875 <IVAESA S `W Certified Elevator Inspections, Inc. `�e199375 7-11 Legion Drive, Suite 103. Valhalla. NY 10595 • Phone: 914 428-3419 Fax: 914 428-5501 • johnceict optonline.net Pe.2 1100 King Street Associates C/O George Comfort& Sons, Inc. 4 International Drive Building#4 Elevators# 1&2 1. When cars are on fire recall and return to lobby the fire buzzers must turn off and lights stay on. Elevators#1 1. In—car emergency phone does not work. Building#S Elevators# 1 &2 1. In—car emergency lights and alarm do not work. Building#6 Elevators# 1 & 2 1. When cars are on fire recall and return to lobby,the fire buzzers must turn off, lights must remain on. Elevator#2 In—car emergency lights and alarm do not work. The violations listed must be corrected in a timely manner as required by the Village of Rye Brook Building Inspector. Elevators are deemed safe to operate, but compliance is mandatory! Please notify this office when all violations have been complied with so that a reinspection can be made and we can provide you with a compliance letter. If you have any questions regarding this report,please feel free to contact my office. Yours truly, l r- ohn G. Boc inis Certified Elevator Inspections NAESA QEI Cert. #C-875 Certified Since 1993 C.c.Michael J. Izzo Village of Rye Brook, Liberty Elevator Corp.