Loading...
HomeMy WebLinkAboutMP22-086 �yE DR � y . 190 "•,�-a VILLAGE OF RYE BROOK MAYOR 938 King Street, Rye Brook,N.Y. 10573 ADMINISTRATOR Jason A.Klein (914) 939-0668 Christopher J.Bradbury www.ryebrook.org TRUSTEES BUILDING&FIRE INSPECTOR Susan R.Epstein Steven E.Fews Stephanie J. Fischer David M. Heiser Salvatore W.Morlino CERTIFICATE OF COMPLIANCE December 11,2023 Matthew Wiener&Erica Wiener 18 Boxwood Place Rye Brook,New York 10573 Re: 18 Boxwood Place,Rye Brook,New York 10573 Parcel ID#: 129.67-1-20 This document certifies that the work done under Mechanical Permit #22-086 issued on 5/27/2022 for the installation of a new Navian combo water heater/boiler has been satisfactorily completed. Sincerely, Steven E. Fews Building&Fire Inspector /to �E BR(��. O� 2m BUILDING DEPARTMENT ,❑BUILDING INSPECTOR pdASSISTANT BUILDING INSPECTOR VILLAGE OF RYE BROOK ❑CODE ENFORCEMENT OFFICER 938 King Street• Rye Brook,NY 10573 (914) 939-0668 FAx (914) 939-5801 www ryebrook.org - - - - - - - - - - - - - - - - - - - - INSPECTION REPORT - - - - - - - - - - - - - - - - - - - - ADDRESS:- / 00X 1*00 C 10L- DATE: 12 1 o4 j PERMIT# I nQ 7 - Qq� ISSUED: S"Z J'ZZ- SECT: BLOCK: LOT: 2 O LOCATION: se M W�- OCCUPANCY: ❑ Violation Noted THE WORK IS... 9 PASSED ❑ FAILED REINSPECTION ❑ SITE INSPECTION REQUIRED ❑ FOOTING ❑ FOOTING DRAINAGE ❑ FOUNDATION ❑ UNDERGROUND PLUMBING NOTES ON INSPECTION: ❑ ROUGH PLUMBING ❑ ROUGH FRAMING ❑ INSULATION ❑ Natural Gas ❑ L.P.Gas ❑ FUEL TANK ❑ FIRE SPRINKLER ❑ FINAL PLUMBING ❑ CROSS CONNECTION 3-TINAL ❑ OTHER _ _ 00 W _ C N Lin kjn F, m H N CA O ai v a7 " r- Wy a rj A p ° a 4 i a+ m did i OW ,�,+ .� G5 4 Lr u V ■ CD Lin m W o cq o © b 1�4 O 4 ^ 00 Q o v C Q Ir N00 F Vzvv Fl- ON 00 �j b O do I--� O A oc G "ate"0 lug �c d '1.1�4 w 0 C oCA 0 o+ ti A x �Q V VJ CFI 0.0 O - O �I PQ a w a w ■ BUILDtNq tRTMENT R CIE ME " �`k MAY 2 6 2022 VILLAE OF RY OOK 938 KING"ET RYE 131110614,NY 10573 VILLAGE OF RYE BROOK ���� t �rr�ok,�►t� BUILDING DEPARTMENT APPLICATION FOR PERMIT TO INSTALL AND/OR REMOVE HEATING, VENTILATION AND/OR AIR CONDITIONING EQUIPMENT FOR OFFICE USE ONLY: PERMIT#: �/P —0 � Approval Date: MAY 27 2022 Permit Fee: $ Approval Signature: Other: Disapproved: (fees are non-refundable) *#***�*t*��,�*r*�**����**�,t*�t**,r*.r,t**�***r****�***,r,t*****,►*tt*****:****�*,►t***�**�*,�,�,t*�**art*�********� REQUIREMENTS FOR RELEASE OF PERMIT&CERTIFICATE OF COMPLIANCE: 1. Properly completed& Signed Application. 2. Site/Staging Plan if Required by the Building Inspector. 3. Copy of Licensed Contractor's Liability Insurance. (Village of Rye Brook must be listed as certificate holder)& Workers Compensation Insurance on a NYS Board form (Form#C105.2 or Form#U26.3/or NY State Workers Compensation Waiver) 4. Payment of Fees/Unit: RESIDENTIAL =$100.00/unit • COMMERCIAL =$350.00/unit. S. Inspection by the Building Department for removal and/or installation. (48 hour notice required) 6. Electrical work requires a separate Electrical Permit& Electrical Inspection. 7. Plumbing/Gas work requires a separate Plumbing Permit& Plumbing Inspection. Application dated, 5126M is hereby made to the Building Inspector of the Village of Rye Brook for a permit for the installation and or removal of the HVAC equipment as listed below.The applicant and property owner,by signing this document agrees that said equipment will be installed and/or removed in conformance with all applicable Local,County,State&Federal laws, codes,rules and regulations. r I. Address: 18 Boxwood PI SBL: /1319•(V 71/—S�0 Zone: 2. Property Owner: Mat Wiener Address: 18 Boxwood PI Phone#: Cell#: 516-456-9053 email: matthew.wiener@gmail.eom 3. Contractor: Salvatore W Morlino Address: 1 Bonwit Road Rye Brook NY 10573 Phone#: Cell#: 914-260-1592 email: salvatoreserious@gmail.com 4. Applicant: Salvatore W Morlino Address: 1 Bonwit Road Rye Brook NY 10573 Phone#: Cell#: 914-260-1592 email: salvatoreserious@gmail.eom 5. Scope of Work:New Installation Od•Replacement( )•Removal( )•Other( ): 6. List Equipment: NFB-200 Navian Fire Tub Boiler, NPE-240A2 Navian Tankless Hot Water Heater 7. Location of Equipment: Basement mechanical room. 8. Method of Instal lation/Removal(list all equipment needed to perform job): HAND TRUCK, REQUIERD PLUMBING t an 2/202 t STATE OF NEW YORK,COUNTY OF WESTCHESTER ) as: 54'1 /tJ UIL 4-k9 ,being duly sworn,deposes and states that he/she is the applicant above named, (print name of individual signing as the applicant) and further states that(s)he is the legal owner of the property to which this application pertains,or that(s)he is the CUti for the legal owner and is duly authorized to make and file this application. (indicate architect,contractor,agent,attorney,etc.) That all statements contained herein are true to the best of his/her knowledge and belief,and that any work performed,or use conducted at the above captioned property will be in conformance with the details as set forth and contained in this application and in any accompanying approved plans and specifications,as well as in accordance with the New York State Uniform Fire Prevention&Building Code,the Code of the Village of Rye Brook and all other applicable laws,ordinances and regulations. Sworn to before me this 2-3 Sworn to before me this � ? day of N✓lk ,2072 day of ,20 7-2- Ile / Signatdre of Property Owner Signature of Applicant PrinLName of Property Owner Print Name of Applicant Notary Public + t+ Notary Publi %0FLW Y 15`��Go��� p tat0 VAQVII WIN OA NOW DAM tc�jqeoor(; age This app)Wion must be properly completed in its entirety and m&?�include the notarized signature(s) of the legal owner(s) of the subject property, and the applicant of record in the spaces provided. Any application not properly completed in its entirety and/or not properly signed shall be deemed null and void and will be returned to the applicant. z 8/12/2021 0 t i N PLO CJ. • it ■ uj k ~ 3 z �., o v F" _ es • L� to oLn Ln CO v H x v � It ►n w=n • w z r A 30 z w a O QU V • o Z O � 3 ,� vw, z z • rr rh� d W z00 A M aj �J U w N w o 04 r 0. U4LQ Ln w • • �o v p w o � � i °` x aN H oo z <114 yE t3RC�v� RAPR IE V� E � W FEBUIL MENTfVu, 'E F:.RVE OK 10 2023 n •. - I 938KINq rRY>✓B NY 105731 VILLAGE OF RYE BROOK \ r I or BUILDING DEPARTMENT w�v . ELECTRICAL PERMIT APPLICATION Westchester County MasterElectricians License Required FOR OFFICE USE ONLY 1�F-#�/� L! d O CS & EP#: 3—( A Approval Date: APR 1 1 2023 Permit Fee: S Approval Signature: Other: Application dated, 4/10/23 is hereby made to the Building Inspector of the Village of Rye Brook NY,for the issuance of a Permit to install and/or remove electrical equipment,wiring,fixtures,or to perform other high or low voltage electrical work as per the detailed statement described below. By signing this document, the applicant & property owner agree that all electrical work performed will be in conformance with all applicable Federal,State,County and Local Codes. 1.Address: 18 Boxwood Place SBL: 129.67-1-20 Zone: 2.Property Owner: Matt Wiener Address: Same Phone#: 914-260-1592 Cell#: email: SalvatoreSerious@gmad.com 3.Master Electrician: Angelo 7.accagninn Address: 81 Maple Ave, Rye NY 10580 Lic.#: 755 Phone#: 914-921-3244 Cell#: email: Office@zaccagnino.net Company Name: Zaccagnino Electric Address: 4.Proposed Electrical Work/Fixture Count: Wiring of Navien boiler replacement 5.31 Party Electrical Inspection Agency: CWIC ***t,r*,t*tr******#•,r****,t«*a,ew****************#*************,t***rr,r*t**t*t,t**t**:**t****,rt**,t*tr**,t*,�,t*,t*#*,t* STATE OF NEW YOM COUNTY OF WESTCHESTER ) as: Angelo Zaccagnino ,being duly swom,deposes and states that he/she is the applicant above named,and does further (print name of individual signing as the applicant) state that(s)he is the legal owner of the property to which this application pertains,or that(s)he is the Electrician for the legal owner and is drily authorized to make and file this application. (indicate architect,contractor,agent,attorney,etc.) The undersigned further states that all statements contained herein are true to the best of his/her knowledge and belief,and that any work performed,or use conducted at the above captioned property will be in conformance with the details as set forth and contained in this application and in any accompanying approved plans and specifications,as well as in accordance with the New York State Uniform Fire Prevention&Building Code,the Code of the Village of Rye Brook and all other applicable laws,ordinances,and regulations. Sworn to Wore me this Sworn to befo me this /C day of 20�_ day of ,20 2-o Z Signature o Property Owner Signa^ e /1141- tlr elves Print Name eG O e Print Name of Applicant STEVE GAGNON TRW Notary PukV 0 1 238 No Qualified in estch ter County No. 01G 238 My Commissl Expires October 14, � _ Qualified in s e r County My Commission xpires October 14, 20 k-19 6/232022 ► STATEWIDE INSPECTION 1:1 Main Street, Fishkill, NY 12524 1 email:office@swisny.com SWIS JOBAPPLICATION tel845.202.72241 • • 1•2 SWISNY.com I SWISTraining.com Office Use Elect Permit# Date Bldg Permit# Utility ID# Final Certificate# ! , , — City/Village Zip _ Township County Address , - L Cross Street Section Block Lot-G i Owner Name/Address(If different than above) Contact Number 13�asement ❑1st Fl. ❑2nd Fl. ❑3rd Fl. ❑More Than 3 Fl. ❑Garage ❑Attic ❑Outside ❑Residential ❑Commercial Receptacles Special Recept GFCI AFCI Switches Dimmers Smoke Alarms Carbon Monox Hood Trash Compact Amt Amps Range(s) Cooktop(s) Oven(s) Dishwashers Refrigerator Disposal Microwave Warm Draw Incandescent Fluorescent SERVICE Amperage Voltage 1 P 3P #Meters #Disconnect ❑Underground ❑New ❑Reconnect ❑Overhead ❑Change ❑Visual Re-Inspection ❑ Safety Re-Inspection ❑ Re-Inspection Additional Information i F, APR 10 2023 3 VILLAGE OF RYE BROOK BUILDING DEPARTMENT This application is valid for one(1)year from the date received by SMS.This application Is intended to cover the above listed items to be Inspected,if at any time of Inspection additional items have been installed,you are authorfttd to make the inspection and adjust the fee for the additional items inspected.The applicant declares that there Is no open application for the above address with any other Inspection company.The applicant,owner or authortzed agent agrees to all the above terms and conditions as set forth for the application. Inspector Date Finalized Inspector# Company Name Date Signature Address City/State Zip e License# Phone# DE C E � V E State Wide Inspection Services cr" 1080 Main Street 3D Fishkill, NY 12524 APR 2 7 2023 845 202-7224 Phone VV a 5 914-219-1062 Fax STATE WIDE INSPECTION SERVICES VILLAGE OF RYE BROOK Email: office@swisny.com BUILDING DEPARTMENT Website: www.swisny.com Service With Integrity —'—' BY THIS CERTIFICATE OF COMPLIANCE STATE WIDE INSPECTION SERVICES CERTIFIES THAT: Upon the application of: Upon Premises Owned by: Zaccagnino Electric Matthew& Erica Wiener Angelo P. Zaccagnino 18 Boxwood Place 81 Maple Avenue Rye Brook, NY 10573 Rye, NY 10580 Located at: 18 Boxwood Place, Rye Brook, NY 10573 Section: Block: Lot: Electrical Permit Number: EP 23-085 129.67 � 20 Certificate Number: 2023-2964 Building Permit Number: MP 22-086 A visual inspection of the electrical system was conducted at the Residential occupancy described below.The electrical system consisting of electrical devices and wiring is located in/on the premises at: 18 Boxwood Place, Rye Brook, NY 10573 The Basement was inspected in accordance with the NYS and NFPA 70-2017 and the detail of the installation, as set forth below,was found to be in compliance on the 261h day of April 2023. Name Quantity Rating Circuit Type Boiler 01 J Officer: Frank 1. Farina This certificate may not be altered in any way and is validated only by the presence of a seal at the location indicated.This certificate is valid for work performed on the date of inspection only. • Dimensions Ratings & specifications Overhead View Navien Condensing Boiler Space Heating Ratings Other Spec'dicatiorm Model Heating input(STU/H) Heating Net AHRI AFUWater Num � Min Max at Capacity2 Rating Water' % rePressssure Connection Size olu o ¢ (BTU/H) (BTU/H) (Supply,Return) 5 - NFB-175H 13,300 175,000 160.000 139,000 95.0 6-80 psi 1-I/4"NPT 4.5 gallons 13,300 1 199,900 182,000 158,000 95.0 A 1 Ratings are the same for natural gas models converted to propane use. z Based on U.S.Department of Energy(DOE)test procedures. 3 The net AHRI water ratings shown are based on a piping and pickup allowance of 1.15. Consult Navien before selecting a boiler for installations having unusual piping and pickup requirements,such as intermittent system operation, -� extensive piping systems,etc. F—t View Model Item -- NFB475H NFB-200H Dimensions 17.3'W x 17.3'D x 27.6'H Boiler weight 121 lb(55 kg) Boiler weight with water 148 lb(67 kg) Installation type Indoor wall-hung Venting type Forced draft direct vent ® Ignition Electronic ignition Natural Gas supply pressure(from source) 3.5'to 10.5'WC Propane Gas supply pressure(from source) 8.0'to 13.0'WC Natural Gas manifold pressure -0.03'to-0.70'WC -0A3'to-0.85'WC Propane Gas manifold pressure -0.02'to-0.68'WC -0.02'to-0.75"WC Supply Corneco•ns Gas connection size 3/4'NPT Power supply Main supply 120V AC,60Hz .0 171Maximum power consumption Less than 15 amperes 0 0 0 0 0 Casing Cold-rolled carbon steel F Y p Materials Heat exchanger Stainless steel 2"or 3"PVC,CPVC,approved polypropylene a Exhaust 2'or 3"special gas vent type BH(Gass III,A/B/C) 2'or 3"stainless steel Venting 2"or 3"PVC,CPVC,polypropylene Intake 2"or 3"special gas vent type BH(Class III,A/B/C) c. sn. 2'or 3"stainless steel ®Aeu,uae mr ®Ea.OG.sven mz' Vent clearance 0"to combustibles ®A4vm COnMR10n Ovr ®1 4N pph, m1•vr Safety devices Flame rod,APS,ignition operation detector,water temperature high limit switch, ®limner— m1-1a exhaust temperature high limit sensor,water pressure sensor,vent installation detector(VID) o G"c01N1 avz" O o yr Ca,dmswe ovum Navien reserves the right to change specifications at any time without prior notice. ® Please refer to Navieninc.com to verify you have the most current information. Gas input ranges Warranty Model Range(13TU/H) TDR Type Residential* Commercial NFB-175H 13,300-175,000 13.2:1 Heat exchanger 15 year limited warranty 10 years NFB-200H 13,300-199,900 15:1 Parts 5 years 3 years ® � ^ ® Labor 1 year 1 year `Appl'res to single family residential locations. " For complete details please refer to the full warranty at Navieninc.com. Navien Inc., 20 Goodyear, Irvine, CA 92618 800-519-8794 Navieninc.com MNavieN T H E L E A D E R 1 N C O N D E N S 1 N G T E C H N O L O G Y NFBH-BRO01-2201 (02022 Navien Inc. 2.3 Specifications The following table lists the specifications for the water heater.Additional specifications about water,gas,electric,and air supplies(venting) appear in the Installation section. Item NPE-1505 NPE-180(A) NPE-1805 NPE-210(A) NPE-2105 PE-2405 Heat Natural Gas 18,000- 15,000-150,000 BTU/H 19,900-180,000 BTU/H 19,900-199,900 BTU/H Capacity 120,000 (Input) Propane Gas BTU/H 15,000-150,000 BTU/H 19,900-180,000 BTU/H 19,900-199,900 BTU/H Energy UEF(for NG&LP) 0.96 0.96 0.97 0.96 0.97 0.96 0.97 Factor EF(Canada)(for NG&LP) 0.97 0.97 0.99 0.97 0.99 0.97 10.99 35°F(19°C)Temp Rise Vm PM(25.8 8.4 GPM(32 Um) 10.1 GPM(38 Um) 11.2 GPM(42 Um) Flow Rate 45°F(25°C)Temp Rise 5.3 GPM 6.5 GPM(25 Um) 7.8 GPM(30 Um) 8.7 GPM(33 Um) (DHW) (20 Um) 67°F(36°C)Temp Rise 3.2 GPM 4.3 GPM 4.2 GPM 5.0 GPM 5.2 GPM 5.6 GPM 5.7 GPM (12 Um) (16 Um) 06 Um) 09 Um) (20 Um) (21 Um) (22 Um) Dimensions 17.3 in(W)x 27.4 in(H)x 13.2 in(D) Weight 62lbs 75lbs 67lbs 82lbs 75lbs 82lbs 75lbs (28 kg) (34 kg) (30 kg) (37 kg) (34 kg) (37 kg) (34 kg) Installation Type Indoor or Outdoor Wall-Hung Venting Type Forced Draft Direct Vent Ignition Electronic Ignition Water Pressure 15-150 PSI Natural Gas Supply Pressure 3.5 in WC-10.5 in WC (from source) Propane Gas Supply Pressure 8 in WC-13in WC (from source) Natural Gas Manifold Pressure -0.04 in WC- -0.04 in WC--0.84 in WC -0.05 in WC--0.36 in WC -0.05 in WC--0.58 in WC (min-max) -0.40 in WC Propane Gas Manifold Pressure -0.05 in WC- -0.05 in WC--0.50 in WC -0.10 in WC--0.66 in WC -0.10 in WC--0.78 in WC (min-max) -0.42 in WC Minimum Flow Rate 0.5 GPM(1.9 Um),<0.01 GPM(0.04 Um)option for"A"models* Cold Water Inlet 3/4 in NPT Connection Hot Water Outlet 3/4 in NPT Sizes Gas Inlet 3/4 in NPT Power Main Supply 120 V AC,60 Hz Maximum Power Supply Consumption 200 W(max 2 A),350 W(max 4 A)with external pump connected Casing Cold Rolled Carbon Steel Materials Primary Heat Exchanger:Stainless Steel Heat Exchangers Secondary Heat Exchanger:Stainless Steel Exhaust 2 in or 3 in PVC,CPVC,Approved Polypropylene 2 in or 3 in Special Gas Vent Type BH(Class II,A/B/C) Venting Intake 2 in or 3 in PVC,CPVC,Approved Polypropylene 2 in or 3 in Special Gas Vent Type BH(Class II,A/B/C) Vent Clearances 0 in to combustibles Safety Flame Rod,APS,Ignition Operation Detector,Water Temperature High Limit Switch,Exhaust Temperature High Limit Sensor, Devices Power Surge Fuse *Available for"A"models configured in an optional ComfortFlow recirculation mode.Energy consumption will increase when the system is configured for recirculation. About the Water Heater 7