Loading...
HomeMy WebLinkAboutBP21-031PERMIT # ��/ � O31 DATE: � `�� � EXP: � �`� �`�' SECTION % ��T� � la BLOCK LOT �„r.�._ p c TYPE OF WORK../.:�7�a%1 �U SO�t?® r,�� -� .�Sio°7 b� �XiS�:�� iC.00��� �J`ZfS�C'it�f JOB LOCATION OWN �e,�ofi� r, CONTRACTOR �r.I�'�'�1.5� �'k7I�A`' �'��'��S L_�C �'•.�Gi�� EST. COST a y �� FEE � � - '- �CO # �e FEES" �2�5� �A DA TCO # FEE _ DATE FOOTING FOUNDATION FRAMING RGH FRAMING INSULATION PLUMBING RGH PLUMBING GAS SPRINKLER _,/ ELECTRIC ��j LOW -VOLT O ALARM AS QUILT FINAL . 1;.13�i��:+� " Z 2 INSP � � L�-c� IL "' 1� - �i� ►�1�--�'19q f� �j'.00 PD ���, U.y�lSe�c,la �'�e��"�G��J�l�1-��� ��lec�i�- OTHER APPROVALS ARB �6�-uQ,u � � ae�� BOT Ps zBA ,OTHER D [EC [E WE n I LU LlFEB 3 2021 ARRAY 2 ----I F, I VILLAGE OF RYE BROOK (Existing) BUILDING DEPARTMENT - Z N �a 0 W E � r •� r S ARRAY 1 (Existing) Property Location fi N.T.S. ; •ice r General Notes i 1. Modules to be SunPower 360 Watt BoW Residential AC Module, to installed per SunPower ARRAY 3 Corporation Installation Manual. 2. Racking to be Invisimount to be installed as per Invisimount Manufacturer's Specifications. 3. Battery backup System to be Sunpower 13kWh battery to be installed per Sunpower Corportaion Installation Manual. 4. Existing Photovoltaic system consists of: 27 SP X22-360-C-AC Residential Modules, with Invisimount Racking, as shown on Array 1 and Array 2. r 5. Expansion system consists of : 8 SP X22-360-C-AC Residential Modules. 6. Total System consists of: 35 SP X22-360-C-AC Residential Modules . Village of Rye Book Wind and Snow Load: A..� +nataar2! Revie ,Roa�� 4 Wind Speed: 120 m.p.h. Approval Date, 1 7 Snow Load: 30 p.s.f. �� 1 Chairman:, UTILITY _METE R Design Notes. This design complies with NYS-Building Code, IRC 2020, NFPA-70-14, and NEC 2017. MAIN DISTRIBUTION _- PANEL&SOLAR AC DISCONNECT LOCATED IN GARAGE Unauthorized alteration or addition to a document prepared by a licensed Professional ----� Engineer is a violation of Section 7209,Sub-Division 2 of the New York State Education Law. 510 N.State Rd. Site Plan DATE VER. DRAWN BY CHECKED BY TOTAL SYSTEM DESCRIPTION: F N Briarcliff Manor, NY 1/11/2021 V1 CCW Existing System Size 9.72 KW DC SYSTEM 0 ��/ 914.762.7622 6.48 KW AC Q� JOSFp O Cohen Residence Expansion Expansion system size 2.88 KW DC SYSTEM CO sunrisesolarllc.com 2.56 KW AC 40 Windingwood Road North Total 12.60 KW DC STC SYSTEM Rye Brook, NY 10573 11.20 AC n Battery Backup:Sunpower Sunvault 13 kWh Q' unrise � w Array 1 Array 2 Array 3 N .� UTIONS Existing ° Existing ° Expansion ° O� ♦ SITE PLAN 1 -Azimuth:114 -Azimuth:294 -Azimuth:114 ,p '0208 Sect 35.26, Block 1, Lot 38 JOB#18-0214 _ ° _ ° �P Tilt:27 Tilt:27 -Tilt:27° 0 �, NORTH 44 SIDE OF N 2 ARRAY 2 o HOUSE w E (Existing) 9) s ARRAY 1 (Existing) 74'-114" E FRONT OF HOUSE ARRAY 3 31'-02" 10'-SZ" 17'-6" 43'-0" o EAST SIDE 0'-1" REAR OF HOUSE 1'-611 \' Ridge _ 1' 6" I i a u n u n n __a 9-8IV I I I I 4 't1111'I1rt- I 1 1 1 t1 i 1 1 1tM rimT TV! 1 1 U T ttft ! ? T 1- SOUTH Vent --"` -- a -- -- "- SIDE OF 10' 44" HOUSE a nt n�t n� 1 n 07 1 t rn-i fi t- 15-42 17'_6" i-S�T-t t-rlTl-r �r1T1'1"-t-i-l-t�r1-7T-t"�1�1-1-fi-i-' --rr�-nn-r-rt-rr-nrT- rrrrtr-rt-r-r-r�s- KEY MAP 21'-4" Vent __ N.T.S. n of i In n n nrt n nt ............... t 1 n���rb� n�t rn��r Vent +1`f`T`t`T t`i-T�f I I I Ti r`f ry i 1-1 1 Vent rt-t�l-r1 -T-T-r-t-1 hrt rt-ti't-1-Tirf � orCCt� =t]t7� ��Z-Ct]C7ZT_=CC L01-7111 ._ Setback: 27 4' 53'-63" 3' Wide Roof 4 Access Pathway ARRAY 1 (Existi ClARRAY 3g) 8-Panels 15-Panels Tilt 270 Tilt 270 Azimuth 1140 Azimuth 1140 510 N. State Rd. Panel Layout Construction DATE VER. DRAWN BY CHECKED BY TOTAL SYSTEM DESCRIPTION: OF NBriarcliff Manor, NY1/11/2021 V1 CCW Existing System Size 9.72 KW DC SYSTEM . t 914.762.7622 6.48 KW AC J4S�p _ ' Cohen Residence Expansion Ex ansion s stem size 2.88 KW DC SYSTEMr�s s p y sun e olarllc.com2.56 KW AC 40 Wlndingwood Road North Total 12.60 KW DC STC SYSTEM �r .0 r— s rn Rye Brook, NY 10573 11.20 AC n = L� Battery Backup:Sunpower Sunvault 13 kWh Array 1 Array 2 Array 3 Existing Existing Expansion � ?�: PANEL LAYOUT � ��� (yam SOLUTIONS zoa.� CONSTRUCTION Sect. 135.26 Block -Azimuth:114o -Azimuth:294o -Azimuth:114 o 1, Lot 38 JOB#18-0214 -Tilt:270 -Tilt:270 -Tilt:270 /Kt, - PLAN FS NORTH • SIDE OF N ARRAY 2 (Existing) ARRAY 2 o HOUSE W E 2 (Existing) 12-Panels S Tilt 270 Azimuth 2940 ARRAY I (Existing) WEST SIDE FRONT OF HOUSE ARRAY 3 291_9111 20_2111 2 . o EAST SIDE REAR OF HOUSE 472'11 Q -- ---r nn -- --- A 1-1 D tl1 a i Ve t 18-9- 18-6- rlrt�t nr -t-f `�rt1-1-�tfi1 4 4 1 1 ry 1 t to Hh- - - tlI i0l I I tl u�t ru i 1�� 15�-4- SOUTH 17'-6" �=7i0t�t`t-1-tl rtUp�1-t-'t-t-r 12 17-6 SIDE OF rT�`r-t�M1`1I t-t I tirl t`fi 1 T- HOUSE n JU D D DIf LLLi KEY MAP Vtmrtt-tit-tu� rl-t-l-t u� ttt-rti N.T.S. r-r-rrrT-TT-r-nrT-r-r-r-rn 1T-1-r-rrr t-fit-r-rUrt-t-r-i 1 tv 1-r-1-1 ti 1'-6" Ridge 13-113 11 4 17'-114" 74'-114" Setback: 3' Wide Roof Access Pathway • DATE VER. DRAWN BY CHECKED BY TOTAL SYSTEM DESCRIPTION: OF NE 510 N.State Rd. Panel Layout Construction Briarcliff Manor, NY 1/11/2021 V1 CCW Existing System Size 9.72 KW DC SYSTEM ,<�` ��JOs��p Q ;P C 914.762.7622 6.48 KW AC •� � r ; Cohen Residence Expansion Ex ansions stemsize 2.88KWDCSYSTEM �� C� 202 sunrisesolarllc.com p y *' -� 40 Windin wood Road North 2.56KWAC ,� �; 0 , .; g Total 12.60 KW DC STC SYSTEM m ye R Brook NY 10573 11.20 AC , Of ' Battery Backup:Sunpower Sunvault 13 kWh a . Array 1 Array 2 Array 3 � �� ,� �� PANEL LAYOUT Existing Existing Expansion A20a COL UTI17NS o o � E� CONSTRUCTION Sect. 135.26, Block 1, Lot 38 -Azimuth.114 -Azimuth.294 -Azimuth.1140 U S JOB#18-0214 -Tilt:270 -Tilt:270 -Tilt:270 PLAN 2„ 2„ (E) RAFTER OR TRUSS 41.2" 14" 14" �v 3M FA ! 1 „I GAP (TYPE INVISIMOUNT RAILS Cables N (2) PER MODULE 0 Module 61.3" Label SUNPOWER MODULE I I I I (TYP.) w w w N �. N ROOF ATTACHMENTS (TYP.) Depth= 1.2" 2" 14" 14„ " 2 Solar Panel Sun Power 360W 96 CELL SUNPOWER MODULE I X22-360-C-AC •INVISIMOUNT RAILS SHALL BE POSITIONED IN THE NON-CROSS HATCHED REGIONS o N.T.S. SUNPOWER INVISIMOUNT MOUNTING CLAMP o POSITIONING DETAILS N.T.S. I END CLAMP y ""- Notes: • Rafter attachments NOT to exceed - " 48" o.c. horizontally • Rafter attachments NOT to exceed SUNPOWER INVISIMOUNT 36" o.c. vertically • Stagger rail every other rafter PLAN VIEW, • 16" o.c. rafters TYPICAL ARRAY LAYOUT N.T.S. MID CLAMP 510 N.State Rd. RackingLa out Plan DATE VER. DRAWN BY CHECKED BY TOTAL SYSTEM DESCRIPTION: l QF NEBriarcliff Manor NY 1 11 2021 V1 CCW Existing System Size 9.72 KW DC SYSTEM �v / / 9 y A, JosEjo p 914.762.7622 6.48 KW AC �, y �40' Cohen Residence Expansion Ex ansions stem iz COsunnsesolarllc.comp y size 2.88 KW DC SYSTEM ,` KW AC n 56 �t' -L 40 Wlndingwood Road North KW DC ST SYSTEM Total 12.56 7� c s s x•�: rn Rye Brook, NY 10573 11.20 AC Battery Backup:Sunpower Sunvault 13 kWh unrlAge r Array 1 Array 2 Array 3 � �°'�' ' RACKING . y y y. �4 �9 .'� � SOLUTIONS Existing Existing Expansion ,p �$ LAYOUT -------- -Azimuth:1140 -Azimuth:294° -Azimuth:114° Sect. 135.26, Block 1, Lot 38 JOB#18-0214 -Tilt:270 -Tilt:270 -Tilt:270 S PLAN S L-BRACKET t MID CLAMP— 1» 5/16"X 4"STAINLESS --�► I NVI S I M O U NT STEEL LAG SCREW RAIL 00 L FOOT HEX CAP SHINGLE ON TOP OF FLASHING -T FLASHING FLAS H I N G COMPOSITION SHINGLES SHOE ASSEMBLY GASKET 5/16 X 4" S.S. LAG BOLT WITH 5/16 WASHER @ CENTER TYP. 2-1/2$1 MIN. EMBEDMENT INTO RAFTER OR TRUSS. PRE—DRILL REQUIRED. SUNM4DO FLASHING DISC (E) RAFTER OR TRUSS 0.5 MIN SUNPOWER INVISIMOUNT ROOF ATTACHMENT DETAIL TYPICAL FLASHING DETAIL r INSTALL WITH GEOCELL N.T.S. NOT TO SCALE From: SunPower Corporation 510 N. State Rd. DATE VER. DRAWN BY CHECKED BY TOTAL SYSTEM DESCRIPTION: O etv RackingDetail Plan Briarcliff Manor, NY 1 11 2021 v1 CCw Existing System Size 9.72 KW DC SYSTEM Jos 914.762.7622 6.48 KW AC C� �� sunrisesolarlic.com Cohen Residence Expansion Expansion system size 2.88 KW DC SYSTEM * O 40 Windin wood Road North 2.56 KW AC Winding wood 12.60 KW DC STC SYSTEM 0 - rn f 11.20 AC fof Rye Brook, NY 10573 BatteryBackup:Sunpower Sunvault 13 kWh ,�` Array 1 Array 2 Array 3 '�Q ,�� ,1 RACKING Existing Existing Expansion � �7Q$ � 917L UTI17N� g . o g . o p. o � DETAIL Sect. 135.26 Block 1 Lot 38 -Azimuth.114 -Azimuth: -Azimuth.114 PLAN - ' JOB#18-0214 -Tilt:270 -Tilt:270 -Tilt:27° —�S1 .. t ilk Ground Access front corner '' roof height 10ft f NORTH ,- SIDE OF N HOUSE W E S FRRAY 2 Ground Access r a. rear corner roof height 10ft q= O ARRAY 1 a* WEST SIDE • FRONT OF HOUSE .� ARRAY 3 Ground Access rear side roof height 10ft f Q o EAST SIDE REAR OF HOUSE Ground Access rear corner roof height 10ft f Y LEGEND O`.• 3 Wide RoofR�m yIa Access Pathway .Y • h Ground Access Qi - Location Roof Access to Ridge Vent / Ridge Vent UTILITY METER --, MAIN DISTRIBUTION SOUTH Solar Panel PANEL&SOLAR AC SIDE OF Ground Access �. Area DISCONNECT LOCATED HOUSE rear corner IN GARAGE roof height 10ft f 510 N. State Rd. Roof Access Plan DATE VER. DRAWN BY CHECKED BY TOTAL SYSTEM DESCRIPTION: OF NSW t Briarcliff Manor, NY 1/11/2021 V1 CCW Existing System Size 9.72 KW DC SYSTEM y JaSFp O 914.762.7622 6.48 KW AC sunr� y •sesolarl/c.com Cohen Residence Expansion Expansion system size 2.88 KW DC SYSTEM CO � '� �-� 40 Wlndingwood Road North 2.56 KW AC Total 12.60 KW DC STC SYSTEM ��?�. ' � 11.20 AC � ��m • Rye Brook, NY 10573 BatteryBackup:ac up.Sunpower Sunvault 13 kWh -- Array 1 Array 2 Array 3 �� ` �' "='�� ROOF ACCESS slaz UTIONS Existing Existing Expansion '0#�2oQS- Azimuth:114° -Azimuth:294° -Azimuth:1140 PLAN Sect. 135.26, Block 1, Lot 38 Mpg#18-0214 � � 0 �� --Tilt:27 -Tilt:27 -Tilt:27 s liitllw Iw iiltw iiiilw lirw iit;iw iiw w w rw w iiw Iw Iw Iw Itw liiw w iw w Iw Iw w w Iw Iw w 1 ROOF TOP 1 w .wwwwww. .wwwwww .wwww. wwwwwwwww .. w. 1 1 P36OW 1 SP360 SP360W S__ 1 1 EXTERIOR 1 3 1 All exposed 1 1 1 - around tobe#6 0,ri;:I e I 1 1 Meter#7424653 1 1 Account#54-4837-1250-0001-6 1 ! EXISTING solCt'ION ! DEVICE 89L =.pox(T yf).; Soso 1 1 UTILITY METER MAIN AC DISCONNECT 120V/240V 1(� TERMINATOR ' Utility Service (RAPID SHUTDOWN SWITCH) ' 1 CAP(TYP. 1 1 0© ® 1 . on 1 Circuit 1-12 Existing SP X22-360-C-AC Modules Array 1 1 12 Total Modules Iw .w iw Iw .w Iw iilw .w .w i� 04 w NJ 1 1 w �wwwwwwwwwt�liwiwwww �lw wwwiwwwt• 1 © 1 r 1 BASEMENT 11 1 1 1 ' Circuit 2-12 Existing SP X22-360-C-AC Modules Array 1&2 1 SUNPOWER 1 , 12 Total Modules 1 EQUINOX 1 STORAGE SYSTEM 1 1 1 Note:Relocate all HUB+ ' 1 1 existing high load 1 _ _ Sensor Wires circuits from ' 1 1 GNP— (TYP•) ' existing main 20o A 1 panel to non-backup pan Non-backup pan EXISTING 1 Circuit 3-3 Existing SP X22-360-C-AC Modules Array 2&3 1 1 1 P�S6 zoo AMP AC 1 1 8 New SP X22-360-C-AC Modules Notes: Solar MAIN 11 Total Modules 1. Labels to complywith PSC and NEC 1 DISTRIBUTION 1 1 !�_'gya� 1 C3 PANEL 1 1 requirements. m BEST 2. All wiring to comply with NEC. 1 MID 120v/240v 1, 1 3. Ground to be continuous BATTERY 1 1 4. Ground wire connections to be Y 1 STORAGE 13 Backup pan "irreversible". 1 6.8 Kw/13.0 kWh 1 5. Meter pan to be grounded only. 1 27 Existing SP X22-360-C-AC Modules 1 6. Neutral to pass through Meter Pan. Inverter m CM 1 1 8 New SP X22-360-C-AC Modules 1 7. No line side tap connection in utility 1 ao m Im meter pan. irn Total 35 Modules 1 8. All equipment to be bonded with 1 m CM �: 1 ground lug per NEC Code. 1 Solar Generation pan m CM 1 9. No additional breakers to be added •-- C11 to spare spaces. 1 C2 20 ® ® CM Note: Existing Strings shall be redistributed to 1 Solar v 20 m CM 1 1 maximize battery input. 1 C 1 0® IID CM Photovoltaic Labeling Legend: 1 1 1 �y m CM DISCONNECT89L SOLAR AC 013 W CM 1 m m t 1 1Ac #10 THHN/THWN-2 1 © m e with#6 Gnd.in Conduit 1 Warning-Inverter Output Connection 1CM1 .. • • 1 m 1 1 For wirig runs inlength over © 1 Im 1 Q please use#8/2 RomexWARNING-DUAL POWER SOURCES: 1 E and#8 Ground Nominal AV Voltage Volts 1 u 1 1 F NE COMBINER PANEL © SOLAR ' '1 1 w Itw w Iw Itw w Iw Iw llllw iw w Iw w w Illtlw Iw iw iw Ms Y CO SOLAR PV CIRCUITS ONLY Do Not Use For Non-Pv Circuits 1 ©© 1 t V. i. rn SOLAR PRODUCTION METE Uj BESS Specifications: WARNING- DUAL POWER SOURCE1 N 1 ---,.. 6.8 KW AC/13 kWh � �(3Z()S SECOND0 6800 Watts_240 Volts=28.3 Amps 'A iiw w w w w w w w w w w w w w w w w w w w w w w w w w NJ 28.3x1.25=35.4Amps,Use 40AmpOCPD 0PHOTOVOLTAIC1 SYSTEM �S1 EQUIPPED SHUTDOWNRAPID 510 N.State Rd. 1 Wire Electrical Diagram DATE VER. DRAWN BY CHECKED BY REMARKS Circuit Calculations: System P stem Specifications: {j Briarcliff Manor,NY g 12/29/2020 v1 ccw Legend: Neutral-White Wire 11 f�� 914.762.7622 - Max.12 Inverters per circuit,20 Amps OCPD PV-35 modules x 360 Watt=12.60 KW DC STC sunrisesolarllccom Cohen Residence Expansion Circuit 12 x 320 Watt Inverters Max.Output=3,840 PV-35 inverters x 320 W AC=11.20 KW AC Exisitng service Ground-Green Wire i Emi 40 Windingwood Road North Watts-240V=16 Amps x 1.25=20 Amps L3 Blue Wire Data Communication Wire Use 20 Amp OCPD J. S1MRSe7 SJ71COW Rye Brook,NY 10573 BESS System 6.8 KW/13 kWh L2 Red Wire --------------- Sensor or Switch Wire ELECTRICAL Total 35 Inverters x 320 Watt Max.Output=11,200 Watts SOLUTIONS 11,200 W_240V=46.7 Amps Nominal AC Voltage=240 V L1 Black Wire 13 Photovoltaic Label WIRING Sect.135.26,Block 1,Lot 38 JOB#18-0214 Max AC Current=46.7A+28.3A=75Amps DIAGRAM