HomeMy WebLinkAboutMP19-209 DR �zY YS y . 19 CCCY iC 4 Ji4G'Vy W V 'C � O VILLAGE OF RYE BROOK MAYOR 938 King Street,Rye Brook,N.Y. 10573 ADMINISTRATOR Jason A. Klein (914)939-0668 Christopher J. Bradbury www.ryebrookny.gov TRUSTEES BUILDING & FIRE INSPECTOR Susan R.Epstein Steven E. Fews Stephanie J. Fischer David M. Heiser Salvatore W.Morlino CERTIFICATE OF COMPLIANCE July 31,2024 Min Sik Pang&Gui Suk Pang Yeon 7 Maple Court Rye Brook,New York 10573 Re: 7 Maple Court, Rye Brook,New York 10573 Parcel ID#: 135.66-1-79 This document certifies that the work done under Mechanical Permit#19-209 issued on 11/25/2019 for the installation of a new gas fired boiler has been satisfactorily completed. Sincerely, Steven E. Fews Building&Fire Inspector /to QyE BRcbl cu � 1982 BUILDING DEPARTMENT ❑BUILDING INSPECTOR ❑ASSISTANT BUILDING INSPECTOR VILLAGE OF RYE BROOK ❑CODE ENFORCEMENT OFFICER 938 KING STREET • RYE BROOK,NY 10573 (914) 939-0668 FAx (914) 939-5801 www.ryebrook.org - - - - - - - - - - - - --- - - - - - INSPECTION REPORT - - - - - - - - - - - - - - - - - - - - ADDRESS : / 4/- 6P t:1 .i/L 7 DATE: PERMIT# MP ` '7 1 ISSUED: SECT: BLOCK: LOT: % LOCATION: �� _ 1 OCCUPANCY: ❑ VIOLATION NOTED THE WORK IS... El' ACCEPTED ❑ REJECTED/ REINSPECTION ❑ SITE INSPECTION REQUIRED ❑ FOOTING ❑ FOOTING DRAINAGE ❑ FOUNDATION ❑ UNDERGROUND PLUMBING NOTES ON INSPECTION: ❑ ROUGH PLUMBING ❑ ROUGH FRAMING ❑ INSULATION ❑ NATURAL GAS ❑ L.P. GAS ❑ FUEL TANK ❑ FIRE SPRINKLER ❑ FINAL PLUMBING ❑ CROSS CONNECTION ❑ FINAL ❑ OTHER WATER HEATERS / BOILERS ---- GW B8-E I ENN[IX Gas-Fired Hot Water Boiler 0651 PRODUCT SPECIFICATIONS Bulletin Maarchrch 201018 Supersedes July 2016 4 wi�a f Yts�4Tm�Fn«�<,� 1 a AFUE up to 83.9% Heating Input - 50,000 to 299,000 Btuh MODEL NUMBER IDENTIFICATION _ 6WB8 - 075E - 3 W Series T Revision Number GB=Gas-Fired Hot Water Boiler 3=3rd Generation AFUE Ignition Mininum Efficiency-8=82% E=Electronic Ignition Capacity(Input) 050=50,000 Btuh 075=75,000 Btuh 100=100,000 Btuh 125=125,000 Btuh ` 150=150,000 Btuh 170=170,000 Btuh 200=200,000 Btuh 262=262,000 Btuh 299=299,000 Btuh FEATURES CONTENTS WARRANTY Circulating Pump Flow Rate........................................8 Cast iron boiler assembly -Limited twenty-year Dimensions..................................................................7 warranty in residential applications only. Features....................................................................... 1 High Altitude Derate.....................................................6 All other covered components -Limited five-year warranty in residential applications. Installation Clearances................................................6 Model Number Identification........................................ 1 Refer to Lennox Equipment Limited Warranty certificate Specifications...............................................................5 included with equipment for details. FEATURES APPROVALS Automatic Gas Control Low pressure, sectional cast iron boilers are design Silent operating gas controls provide 100% safety shut certified by CSA for use with natural gas or LPG/ off. Propane. 24 volt redundant combination gas control valve Annual Fuel Utilization Efficiencies are based on US combines automatic safety pilot, manual shut off option DOE test procedures and FTC labeling regulations. (On-Off), pilot filtration, automatic electric valve (dual) Units are certified by AHRI. and gas pressure regulation into a compact combination Boiler heat exchanger assemblies are constructed and control. hydrostatically tested in accordance with American Dual valve design provides double assurance of 100% Society of Mechanical Engineers (ASME) Boiler and close off of gas to the pilot and main burners on each off Pressure Vessel Code Section IV Standards for cast cycle. iron heating boilers.. Stainless Steel Burners (050 to 200 Models) APPLICATIONS Each burner has rows of continuous ports which result Heating inputs of 50,000 to 299,000 Btuh. in quiet and clean combustion. AFUE's of up to 83.9%. Titanium Burners(262 and 299 Models) Natural gas or LPG/Propane (LPG with optional Titanium composite burners resist corrosion and conversion kit). oxidation. Boiler applications include radiant floor heating, Slotted port design results in quiet, clean combustion. baseboard heating and zoned heating systems. Superior strength and longevity. Compact size allows easy installation in a basement or Circulating Pump utility room. Heavy duty pump is constructed of cast iron. All units are completely factory assembled with all Pump motor is impedance protected. controls installed and wired. Each unit is factory test operated to ensure dependable Motor and impeller is removeable as a single unit for performance. servicing. Pump is shipped separately for field installation. HEATING SYSTEM Cast Iron Boiler Assembly Relief Valve Boiler sections and push nipples are constructed of long Furnished as standard and factory installed on 50 to life cast iron. 200 models. Field installed on top of cabinet on 260 and 299 models. Boiler sections and push nipples expand and contract Valve provides for pressure relief of heating system in together, providing positive watertight seal. case of abnormal operating conditions. Boiler components are easily accessible for cleaning Valve opens at 30 psig and is approved by ASME. and servicing. Electronic Ignition Combination Temperature/Pressure Gauge Electronic spark igniter provides positive ignition of pilot Gauge monitors system for safe and reliable operation. burner on each operating cycle. Brass Drain Valve Pilot gas is ignited and burns during each running cycle 3/4 in. brass drain valve is furnished as standard and of the boiler. factory installed in drain outlet on side of cabinet on 50 Main burners and pilot gas are extinguished during the to 200 models. Filed installed on 260 and 300 models. off cycle. See dimension drawing for location. Ignition system permits main gas valve to open only Optional Accessories when the pilot burner is proven to be lit. Should flame fail to ignite, control will continue to re- LPG/Propane Conversion Kit attempt ignition. Conversion kit required for field changeover from natural gas. Pilot operation is fully automatic on demand for heat. Kits available for standard and high altitude operation. Should a loss of flame occur, the main valve closes, See Specifications shutting down the unit. tables. GWB8-E/Page 2 FEATURES IGNITION CONTROL MODULE LED Status Lights Control module provides ignition sequence, flame Status lights on top monitoring and safety shutoff for intermittent pilot spark of control continually ignition heating system. indicates which functions are active and if the BOILER CONTROL MODULE control is holding the On-board microprocessor burner off for any reason. m saves fuel by adjusting boiler TEMP temperature based on heating ! ACTIVE—Indicates the control is powered and the demand. temperature function is active. Easy dial-in settings for low/high HI TEMP—Illuminates any time the burner is off as temperature limits and economy settings. a result of the boiler reaching the high limit setting. Installed external to the boiler LWCO cabinet in durable protective ACTIVE— Illuminates when the control is providing housing with display window. low water cut-off protection. • LOW WATER—Indicates a low water condition in Thermal Targeting the boiler. Microprocessor-based algorithm monitors thermostat activity and continually evaluates how much heat the ECONOMY house requires. When it is very cold outside, heat • ACTIVE—Indicates that the Economy dial is turned demand is high and the control raises the boiler Target on and that Thermal Targeting function is active. Temperature to provide needed heat to the house. • TARGET—Illuminates any time the burner is When the outside temperature is milder, heat demand is off as a result of the boiler reaching the Target lower. During these periods, the control lowers the boiler temperature determined by Thermal Targeting. Target Temperature-saving fuel-while continuing to • TEST SETTINGS BUTTON—Automatic or Manual provide comfort to the house. reset mode. and test settings for initial control setup. Thermal Pre-Purge ADDITIONAL CONTROLS Enhances boiler efficiency by supplying latent heat that may remain in the boiler from a previous run cycle to the Flame Rollout Switch heating zone requiring heat. The control activates the Temperature sensitive fusible-link device is furnished burner only when it determines that the latent heat will and factory installed on the boiler base just outside of not be adequate to satisfy the heating demand. the burner box. Enhanced Condensing Protection (Optional Setting) Prevents unit operation in the event combustion Allows the boiler to heat to 125°F before energizing the products passageway through the flueway is reduced or circulating pump, reducing the potential for condensing. blocked. Once activated, the control continues to monitor boiler Junction Box temperature and interrupts the pump if it drops below Furnished in Control Module housing for easy field 115°F. wiring. Display LEDs Limit Sensor Three, seven segment LEDs continually displays Factory installed immersion type limit sensor provides boiler temperature. Instantly changes to display control protection against abnormal operating conditions. settings when any dial is adjusted. Indicator light for heating call. Transformer Fahrenheit or Celsius display. 40VA transformer furnished for control module operation. Optional Accessories Thermostat See Thermostat bulletins in Controls section and Lennox Price Book for a complete list of thermostats. GWB8-E/Page 3 FEATURES VENTING CABINET Blocked Vent Shutoff Sensor Constructed of heavy gauge steel with a baked-on Temperature Switch prevents unit operation in case of enamel paint finish. flue blockage. Cabinet is fully insulated with fiberglass insulation, Sensor is furnished as standard and factory installed at keeping cabinet surface temperatures low. the relief opening of the draft diverter. Hole for drain valve (furnished) is furnished on left side Integral Draft Hood of cabinet for 262 and 299 models only. Reduces the overall height and footprint of the Controls are shipped factory installed on right side of boiler making it ideal for low clearance/space limited cabinet. installations. Burner access panel is easily removed for servicing. Vent Damper Integral draft diverter is part of unit cabinet. Motorized vent damper electrically interlocks with the gas ignition system to increase efficiency of heating system by reducing loss of heated air up the chimney after burner shut off. Also reduces chimney infiltration during boiler off cycle. Furnished as standard for field installation. GWB8-E/Page 4 SPECIFICATIONS Model No. GWB8-050E-3GWB8-075E-3GWB8-100E-3GWB8-125E-3GWB8-150E-3 Gas Heating capacity input-Btuh 50,000 75,000 100,000 125,000 150,000 Heating Heating capacity output-Btuh 42,000 63,000 83,000 104,000 124,000 Performance ' Net AHRI I=B=R rating-Btuh 37,000 55,000 72,000 90,000 108,000 z AFUE 83.5% 83.1% 83.0% 82.0% 83.0% Boiler Data Number of boiler sections 2 3 3 4 4 Boiler capacity-U.S.gallons 2.4 4.0 4.0 5.6 5.6 Connections Flue Size diameter(round) 4 5 6 6 7 in. Gas piping Natural gas 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT size I.P.S. LPG/Propane 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT Water supply and return size 1-1/4 NPT 1-1/4 NPT 1-1/4 NPT 1-1/4 NPT 1-114 NPT Drain connection size 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT Electrical characteristics 120 volts-60 hertz-1 phase(less than 12 amps) Shipping Data lbs.-1 package 205 253 253 315 315 OPTIONAL ACCESSORIES See Lennox Price Book For Complete Listing of Optional Accessories LPG/Propane Conversion Kit 68E01 I 76E01 68E01 71E01 68E01 Net AHRI water ratings indicate the amount of equivalent direct radiation each boiler will produce under normal conditions and thermostatic control.Ratings based on an allowance of 1.15 in accordance with the factors shown on the I=B=R Standard as published by The Hydronics Institute.Selection of boiler size should be based on'Net I=B=R Rating"being equal to or greater than the calculated heat loss of the building. Annual Fuel Utilization Efficiency based on US DOE test procedures and FTC labeling regulations. SPECIFICATIONS Model No. GWB8-170E-3 GWB8-200E-3 GWB8-262E-3 GWB8-299E-3 Gas Heating capacity input-Btuh 170,000 200,000 262,000 299,000 Heating Heating capacity output-Btuh 139,000 165,000 220,000 251,000 Performance Net I=B=R rating-Btuh 121,000 143,000 191,000 218,000 2AFUE 82.0% 82.0% 83.9% 83.7% Boiler Data Number of boiler sections 5 5 8 9 Boiler capacity-U.S.gallons 7.2 7.2 12.7 14.4 Connections Flue Size diameter(round) 7 8 7 7 in. Gas piping Natural gas 1/2 NPT 1/2 NPT 3/4 NPT 3/4 NPT size I.P.S. LPG/Propane 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT Water supply and return size 1-1/4 NPT 1-1/4 NPT 1-1/4 NPT 1-1/4 NPT Drain connection size 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT Electrical characteristics 120 volts-60 hertz-1 phase(less than 12 amps) Shipping Data lbs.- 1 package 377 377 552 616 OPTIONAL ACCESSORIES See Lennox Price Book For Complete Listing of Optional Accessories LPG/Propane Conversion Kit 1 71E01 68E01 72E01 74E01 Net AHRI water ratings indicate the amount of equivalent direct radiation each boiler will produce under normal conditions and thermostatic control.Ratings based on an allowance of 1.15 in accordance with the factors shown on the I=B=R Standard as published by The Hydronics Institute.Selection of boiler size should be based on"Net I=B=R Rating"being equal to or greater than the calculated heat loss of the building. Annual Fuel Utilization Efficiency based on US DOE test procedures and FTC labeling regulations. GWB8-E/Page 5 HIGH ALTITUDE DEBATE CSA certified units for the U.S. must be derated when installed at an elevation of more than 2000 feet above sea level. If unit is installed at an altitude higher than 2000 feet, the unit must be derated 4%for every 1000 feet above sea level. Thus, at an altitude of 4000 feet, the unit would require a derate of 16%. CSA certified units for Canada must be derated when installed at an elevation of more than 2000 feet above sea level. If unit is installed at an altitude higher than 2000 feet, the unit must be derated 10%for elevations between 2000 feet and 4500 feet above sea level. NOTE—This is the only permissible derate for these units. INSTALLATION CLEARANCES - INCHES (MM) Size 050 to 200 262 to 299 Models Models Left Side 3(76) 6(152) Right Side Gas Supply/Control Side 9(229) 7(178) Top 18(457) 6(152) Front 'Alcove 'Alcove Rear 4(102 6(152) Service Clearance(Front and Right Side) 24(610) 24(610) 2 Floor Non-Combustible Non-Combustible Flue Pipe Vertical 6(152) 6(152) Horizontal 6(152) 6(152) Type"B"vent pipe(vertical venting only) 1 (25) 1 (25) Hot Water Piping 2(51) 2(51) NOTE-Air for combustion must conform to the methods outlined in the National Fuel Gas Code(NFPA 541 ANSI-Z223.1)or the National Standard of Canada CAN/CSA-B149.1"Natural Gas and Propane Installation Code'. NOTE-In the U.S.flue sizing must conform to the methods outlined in the current National Fuel Gas Code(NFPA 54/ANSI-Z223.1)or applicable provisions of local building codes.In Canada flue sizing must conform to the methods outlined in National Standard of Canada CAN/CSA-B149.1. Definition of Alcove is a three-sided space with no wall in front of boiler.ANSI standard for alcove is 18 inches(457 mm)from front of appliance to leading edge of side walls. 2 Clearance for installation on combustible floor if combustible flooring base(field supplied)is installed between the boiler and the combustible floor. GWB8-E I Page 6 DIMENSIONS - INCHES (MM) - 050 TO 200 MODELS VENT DAMPER 44 A 27(686) 10 (Furnished) C 3-112 5-1/2 3 (89) (140) BOILER (76) SUPPLY CONTROL D WATER MODULE\ n9 RELI�F�; IGNITION VALVE BLOCKED J RETURN CONTROL TEMPERATURE/ VENT /WATER MODULE\ v SENSOR DRAIN (78 1) PRESSURE GAUGE rl B ( VALVE 781 l (Furnished) RETURN 14 ROLLOUT WATER (356) SWITCH A 4-1/4 \GAS VALVE (108) LEFT SIDE VIEW FRONT VIEW RIGHT SIDE VIEW NOTE-Pump is shipped separately with unit for field installation. Model No. A B C D in. mm in. mm in. mm in. mm GWB8-050E-3 11-1/8 283 36-1/4 921 5-1/2 140 5-3/4 146 GWB8-075E-3 15 381 37-3/4 959 7-1/2 191 5-3/4 146 GW138-100E-3 15 381 37-1/4 946 7-1/2 191 6 152 GW138-125E-3 18-7/8 479 37-1/4 946 9-1/2 241 6 152 GWB8-150E-3 18-7/8 479 37-3/4 959 9-1/2 241 6-3/4 171 GWB8-170E-3 22-3/4 578 38-3/4 984 11-1/2 292 6-3/4 171 GWB8-200E-3 22-3/4 578 1 38-3/4 1 984 1 11-1/2 292 7-3/4 197 NOTE-Add 6(152 mm)to height for Vent Damper. DIMENSIONS - INCHES (MM) - 262 TO 299 MODELS I I VENT DAMPER SUPPLY RELIEF 04 />, WATER 26-1/2(673) I � (Furnished) VALVE IWATER TEMPERATURE/ 4-3/4 C� PRESSURE GAUGE (121) (Furnished, Field Installed) � BOILER CONTROL_ u IGNITION MODULE r CONTROL DRAIN BLOCKED MODULE VALVE VENT / SENSOR 1 36-3/8 (Furnished) RETURN 29 RETURN (924) �/WATER + �(737) ROLLOUT WATER SWITCH,,,,,,, GAS VALVE (311) 0 11 (13/837) LEFT SIDE VIEW FRONT VIEW f RIGHT SIDE VIEW NOTE-Pump is shipped separately with unit for field installation. 1 Minimum acceptable height for low water cutoff probe. A Model No. in. mm GW68-262E-3 27-1/2 699 GWB8-299E-3 30-3/4 781 NOTE-Add 7(178 mm)to height for Vent Damper. GWB8-E/Page 7 CIRCULATING PUMP FLOW RATE AWc?C17 00 CIRCULATORS FLOW-M3/H 0.0 0.3 0.6 0.9 1.2 1.5 1.8 2.1 2.4 2.7 3.0 3.3 3.6 3.9 4.2 4.5 4.8 5.1 5.4 16 4.8 — 003B 14 Q_. 005 4.2 —Q-- 006 — 006B 12 '—Qs — 007 3.6 6 —�— 008 cr w 10 3.0 w w *5 F LL LU 0 z8 �� � 2.4 w J ; _ Q O 6 1.8 4 1.2 t 2 0.6 0 0.0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 FLOW-GPM *007 Pump furnished with all boilers REVISIONS Section Description New Added circulator pump flow rate chart. pE51G V AA SE sa As RJE211111 woad CERTIFIEDIr., to sP o a CFATIFA H Visit us at www,lennox.com LENVNDX For the latest technical information,www.LennoxPros.com Contact us at 1-800-4-LENNOX NOTE-Due to Lennox'ongoing commitment to quality,specifications,Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation,adjustment,alteration,service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. 02018 Lennox Industries,Inc. 4f ' II 5 4� � ' .II M1�h• II '� gg rn'• t �1 a�.L �1r yg -oil W k £4 "ant Ck tlt�li� "� �sLs! p-r! ,gyps 11 rv`. r)� N ji ry h. 'r �"g$,s 'Y �A. � �x ��i1f#ij4r s.. r .,irifl+iiirr. .. L .•�eiii�ii4� i14 r�iy#i 1 jty. fiCe5.3 spD _-,. -s•_::...aaa......�..�ta....�.� _.i....f••�!:+.!; .t;, iS.�a�4!£^F,...S-.. " l!!r adE I K• ,`i'i j I.f;. $� ��"s' L Y. s v N A pm LIJ . c � � � it •«�f:~:. ,i I `~ .� cr- M wh J rc7as K� r a O w r., 0' w p cry Z ,•r ��.. Z Z �yryuj _ v LIJ z � its•'}}� �..r aim '� i- r x g tj A E a v _ •^ r .j CD tr ,:r, �as` `�� ...^�*a�_ "A;�^�--•. '-�--gs'.^-:s��-+-r s'""-�.,.>,.F _ ...._.�. "�S' :��—r e -r•.,s:r ! _"�.:"�'2.�:.:°"'s ii .�"�hC�r)kj ;:: , '+.rrr��yygt+ih• :Ea:_:. nri�}+��rr4a �;y� -kilt+}r ilw. ; �, r��+¢++hr�' �* ,.- � �ii��+rr��_, : ..,i�i!+ =ttiti+lti n�•.� A. {yt�+ iii(! �g 7,g( t�t !i gf� 1k:1+1iJ� ��& 4}*' if ca s_�zgSgiq :!}l4t f F'sa �f!!� - n. i!° ,. PA3"7?' �,40� IC1RiSD + AT'�. f♦ ��. ",P: 4! A9Y �'e �7'j i FF��;,� �. r hr, h� u'•'w. tl °}yi y�'.r � .�.� ^' a*.. � �i �Y 'Y7��� a'i/�il'�� y ..�� 'wv,(l.�• �j�• �/d;L�A'�y�}���in �l.. ��� 4 ��,,�4x bh h M •r.r.~Y.,, .r 3 'a-, _i W �tF. "•,y 9,y� .i 3 Jy ,t4' A OC RO® CERTIFICATE OF LIABILITY INSURANCE DATE 2/1012 18 VI 12/10/2018 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsements. PRODUCER CONTACT NAME: CLIENT CONTACT CENTER FEDERATED MUTUAL INSURANCE COMPANY PHONE FAX HOME OFFICE: P.O.BOX 328 CA.. .. Ext:888-333-4949 a/c No):507-446-4664 OWATONNA, MN 55060 E-MAIL ADDRESS:CLIENTCONTACTCENTER FEDINS.COM INSURERS)AFFORDING COVERAGE NAIC# INSURER A:FEDERATED MUTUAL INSURANCE COMPANY 13935 INSURED 286-468-4 INSURER B: ARCTIC MECHANICAL INCORPORATED INSURER C: 460 N MAIN ST PORT CHESTER, NY 10573-3310 INSURER D: INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER:90 REVISION NUMBER:0 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN. THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE DL SUBR POLICY NUMBER POLICY EFF POLICY EXP LIMITS LTR INSR NIVD MMIDDIYYYY MMIDDIYYYY X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $1,000,000 CLAIMS-MADE ❑X OCCUR DAMAGE TO RENTED $100 000 PREMISES Ea occurrence MED EXP(Any one person) EXCLUDED A N N 9907993 01/18/2019 01/18/2020 PERSONAL a ADV INJURY $1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $2 000 000 X POLICY ❑SECT I LOC PRODUCTS-COMPIOP AGG $2,000,000 OTHER: AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ Ea acciden 1,000,000 X ANY AUTO BODILY INJURY(Per person) OWNED AUTOS ONLY SCHEDULED A AUTOS N N 9907993 01/18/2019 01/18/2020 BODILY INJURY(Per accident) HIRED AUTOS ONLY NON-OWNED PROPERTY DAMAGE AUTOS ONLY Per. X UMBRELLA LIAR X OCCUR EACH OCCURRENCE $9,000,000 A EXCESS LIAB CLAIMS-MADE N N 9907994 01/18/2019 01/18/2020 AGGREGATE $9,000,000 DED I X I RETENTION$10,000 WORKERS COMPENSATION Y/N ER TH- AND EMPLOYERS'LIABILITY X PER STATUTE DER ANY PROPRIETORIPARTNERIEXECUTIVE E.L.EACH ACCIDENT $1,000,000 A OFFICER/MEMBER EXCLUDED? NIA N 9298530 01/18/2019 01/18/2020 (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $1,000,000 If yes,describe under DESCRIPTION OF OPERATIONS below E.L DISEASE-POLICY LIMIT $1,000,000 DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached if more space is required) CERTIFICATE HOLDER CANCELLATION 286-468-4 90 0 VILLAGE OF RYE BROOK SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 938 KING ST THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN RYE BROOK, NY 10573-1226 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE O 1988-2015 ACORD CORPORATION.All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD Workers CERTIFICATE OF ' s-f-ArE'Compensation NYS WORKERS' COMPENSATION INSURANCE COVERAGE Board '•a.Legal Narne A Address rf Insured(use street rddi-PS8 o:liy; lb Surress Teiepti,iu Niirntiyr rf Ir u:,ter! ARCTIC MECHAMC•AL INCORPORATED #286-468.4 r914'934-8301 460 N MAIN BTREET N PORT CHESTER.,NY 1 0595-1 31 9 le.NYS'lnamployrnent;nsurarce Emplc✓er kag:stalion tiumoerof insured :Mork Location of insured(Only required it cova2i<Ja is SpBCi`C3!I%hrryted to 1 d. sdarai Ernployer idea lifination Number of:n,urer or Social Sa_urity caRain lccatior.•s rn tiler,•York State...e-a Wrap-Up Pc!icy) +urn ber W-159344c3 2.Name and Address of Entity Requesting Proof of Coverage 3a.-Name of insurance Carrier (Entity Being Listed as the::ettifr:ate Ho:rerj e'.ierated Mutual insurance Corrrpanv Village Of Rva Brook 90 938 King St 3b.Policy Number•Y Entity Listed in Box"1 a" Rve Brcok.NY+,0573-„2E a21 985,1r 3c Policy effective period 011i19Q019 to 01!1°'2020 ..........---...... .-...................._......_._._. i 3d.The Proprietor,Partners or Executive Officers are iXl inciuded.;Orly ctlw*brz i;al;�adrars'ofS�,ys.::rluArvl ail 2rduded of detain p2ttnarsloff•Cers exouder. This certifies that the insurance carrier'ridicated above in box"3''insures^le business referenced above ii,box"a'for woricers compensation Under the New York State Workers'Compensation Law.(To use this form.New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy). 'f he Insum,nee Carrier or its licensed agent wi::send this Certificate of Insurance to the sn'-t' •1'•sted above as the certificate holder in box The insurance carrier must notify the above rwtificats holder and the Workers Compensation Boar;within 10 days:F a policy is ranceied due to nonpaymer:t of premiums or within 30 days iF there are reasr>ns other thar.nonpavment of rnremiurns that;ancsl the nolicy of eliminate the insured from the coverage irioic i-ed on this(;erificate.;Thal.^;nr ;C:'"5 may he sent by regular:rail)Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent,or until the policy expiration abate listed in box"3c",whichever is earlier. This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or alter tie coverage afforded by the Policy listed,nor does it confer any rights or responsibilities beyond those contained:n the referenced Policy. This certificate may be used as evidence of a'workers'Compensation contract of insurance only vinde the urderiyina policy is in effect. Please Note: Upon cancellation of the workers'compensation policy indicated on this form,if the business continues to be named on a permit,license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury.I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted an this form. Approved by: Carlie Pal.Berg (R fit mace u'e:atanzw rep—n;enwl,L o;:icu,rs—J overt w i;isu:arl (kx;;L App-oved by: S�rrature i (Oatei Title:Authorized Representative Telephone Number of authorized representative or licenser:agent of insurance carrier: (386.1333-4949 Please"Dote:Only insurance carriers and their licensed agents are authorized to issue Form C-105.2.Insurance brokers are NOT authorized to issue it. C-105-2(9-1'} wwww-wcb.nv.9ov