HomeMy WebLinkAboutMP18-060 DR. 19 t� GG VILLAGE OF RYE BROOK MAYOR 938 King Street, Rye Brook,N.Y. 10573 ADMINISTRATOR Jason A. Klein (914) 939-0668 Christopher J.Bradbury www.ryebrook.orQ TRUSTEES BUILDING & FIRE INSPECTOR Susan R. Epstein Steven E. Fews Stephanie J. Fischer David M. Heiser Salvatore W. Morlino CERTIFICATE OF COMPLIANCE February 21,2024 Richard Larsen&Karine Larsen 20 Tamarack Road Rye Brook,New York 10573 Re: 20 Tamarack Road, Rye Brook,New York 10573 Parcel ID#: 135.67-2-47 This document certifies that the work done under Mechanical Permit #18-060 issued on 5/29/2018 for the installation of a new condenser and coil has been satisfactorily completed. Sincerely, Steven E. Fews Building&Fire Inspector /to QyE BRC�k. • �9°2 BUILDING DEPARTMENT ❑�_,/BUILDING INSPECTOR 9ASSISTANT BUILDING INSPECTOR VILLAGE OF RYE BROOK ❑CODE ENFORCEMENT OFFICER 938 King Street• Rye Brook,NY 10573 (914) 939-0668 FAx (914) 939-5801 www ryebrook.org - - - - - - - -- - - - - - - - - - - - INSPECTION REPORT - - - - - - - - - - - - - - - - - - - - ADDRESS : 2 LJ I A vq I A DATE: Z PERMIT# z //P Zh—O6 (-Q ISSUED:S--?9-/cam SECT: BLOCK: Z LOT:'0 /� �LOCATION: I �� S , �� G-. OCCUPANCY: 210 ❑ Violation Noted THE WORK IS... 0-'PASSED ❑ FAILED REINSPECTION ❑ SITE INSPECTION REQUIRED ❑ FOOTING ❑ FOOTING DRAINAGE ❑ FOUNDATION ❑ UNDERGROUND PLUMBING NOTES ON INSPECTION: ❑ ROUGH PLUMBING ❑ ROUGH FRAMING ❑ INSULATION J , ❑ Natural Gas ❑ L.P. Gas C ❑ FUEL TANK ❑ FIRE SPRINKLER l ❑ FINAL PLUMBING _ ❑ CROSS CONNECTION --' [FINAL ❑ OTHER 1 rAWE■ Submittal Split System Cooling 3.0 Ton 4TTR3036H1000N 1 TAG: 1 SAFETY . ■ Only qualified personnel should install and service the equipment.The installation,starting up,and servicing of heating,ventilating,and air-conditioning equipment can be hazardous and requires specific knowledge and training.Improperly installed,adjusted or altered equipment by an unqualified person could result in death or serious injury.When working on the equipment,observe all precautions in the literature and on the tags,stickers,and labels that are attached to the equipment. August 2016 4TTR3036H-SUB-1 B-EN ®R Ingersoll Rand. TRWE' B SERVICE PANEL C ELECTRICAL AND REFRIGERANT COMPONENT CLEARANCES PER PREVAILING CODES TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR AT LEAST 1524(5 FEET) ABOVE UNIT.UNIT SHOULD BE PLACED SO ROOF RUN-OFF WATER DOES NOT POUR DIRECTLY ON UNIT AND SHOULD BE AT LEAST 305(12")FROM WALL AND ALL SURROUNDING SHRUBBERY ONTWO SIDES. OTHERTWO SIDES UNRESTRICTED ELECTRICAL SERVICE K PANEL .r 2511) 22.2(7/8)DIA.HOLE A LOW VOLTAGE 28.6(1-1/8)DIA.K.O.WITH 22.2(7/8)DIA.HOLE IN CONTROL BOX BOTTOM FOR ELECTRICAL POWER SUPLY LIQUID LINE SERVICE VALVE, E" I.D.FEMALE BRAZE CONNECTION WITH 1/4"SAE FLARE PRESSURE TAP FITTINGS G 9 FIG.1 K.O.FOR ALTERNATE ELECTRICAL ROUTING From Dwg.D152898 GAS LINE 1ATURN BALL SERVICE VALVE, "D" I.D.FEMALE BRAZED CONNECTION WITH 1/4"SAE FLARE PRESSURE TAP FITTING.A Model Base A B C D E F G H I K 4TTR3036H 3 730 829 756 3/4 3/8 137 79 197 60 508 (28-3/4) (32-5/8) (29-3/4) (5-3/8) (3-1/8) (7-3/4) (2-3/8) (20) SOUND POWER LEVEL Model A-Weighted Sound Full Octave Sound Power[dB] Power Level[dB(A)] 63 Hz* 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 4TTR3036G 68 74.7 65.0 65.2 66.4 63.6 58.7 56.3 52.8 Note:Rated in accordance with AHRI Standard 270-2008*For reference only66 2 4TTR3036H-SUB-1 B-E N TRAAFF Product Specifications OUTDOOR UNIT(a)W 4TTR3036H 1000N (a) Certified in accordance with the Air-Source Unitary Air-conditioner POWER CONNS.—V/PH/HZ(c) 208/230/1/60 Equipment certification program,which is based on AHRI standard 210/240. MIN.BRCH.CIR.AMPACITY 18 (b) Rated in accordance with AHRI standard 270. BR.CIR.PROT.RTG.—MAX.(AMPS) 30 (�> Calculated in accordance with Natl.Elec.Codes.Use only HACR circuit breakers or fuses. COMPRESSOR CLIMATAUFFp-SCROLL (d) This value shown for compressor RLA on the unit nameplate and on NO.USED—NO.STAGES 1—1 this specification sheet is used to compute minimum branch circuit ampacity and max.fuse size.The value shown is the branch circuit VOLTS/PH/HZ 208/230/1/60 selection current. R.L.AMPS(a)—L.R.AMPS 14.1—75 W No means no start components.Yes means quick start kit components.PTC means positive temperature coefficient starter. FACTORY INSTALLED M Standard Air—Dry Coil—Outdoor (g) This value approximate.For more precise value see unit nameplate. START COMPONENTS W NO (h) Max.linear length 60 ft.;Max.lift—Suction 60 ft.;Max.lift—Liquid INSULATION/SOUND BLANKET NO 60 R.For greater length consult refrigerant piping software Pub.No. COMPRESSOR HEAT NO 32-3312-0*(*denotes latest revision). OUTDOOR FAN PROPELLER DIA.(IN.)—NO.USED 23—1 TYPE DRIVE—NO.SPEEDS DIRECT—1 CFM @ 0.0 IN.W.G.M 2900 NO.MOTORS—HP 1-1/8 MOTOR SPEED R.P.M. 825 VOLTS/PH/HZ 200/230/1/60 F.L.AMPS 0.7 OUTDOOR COIL—TYPE SPINE FIN'" ROWS—F.P.I. 1-24 FACE AREA(SQ.FT.) 12.89 TUBE SIZE(IN.) 3/8 REFRIGERANT LBS.—R-410A(O.D.UNIT)(9) 4 LBS.,13 OZ FACTORY SUPPLIED YES LINE SIZE—IN.O.D.GAS(h) 3/4 LINE SIZE—IN.O.D.LIQ. 3/8 CHARGING SPECIFICATIONS SUBCOOLING 10*F DIMENSIONS H X W X D CRATED(IN.) 34 x 30.1 x 33 WEIGHT SHIPPING(LBS.) 175 NET(LBS.) 147 4TTR3036H-SUB-1 B-EN 3 0 TRANE' Mechanical Specification Options General Compressor The Outdoor Units are fully charged from the factory The compressor features internal over temperature, for up to 15 feet of piping.This unit is designed to pressure protection and total dipped hermetic motor. operate at outdoor ambient temperatures as high as Other features include:Centrifugal oil pump and low 115°F. Cooling capacities are matched with a wide vibration and noise. selection of air handlers and furnace coils that are AHRI Condenser Coil certified.The unit is certified to UL 1995. Exterior is designed for outdoor application. The outdoor coil provides low airflow resistance and efficient heat transfer.The coil is protected on all four Casing sides by louvered panels. Unit casing is constructed of heavy gauge,galvanized Low Ambient Cooling steel and painted with a weather-resistant powder paint finish on all louvered panels and the fan top panel.The As manufactured,this system has a cooling capacity to corner panels are prepainted.All panels are subjected 55°F.The addition of an evaporator defrost control to our 1,000 hour salt spray test.The base is made of a permits operation to 40°F.The addition of an CMBP-G30 weatherproof material to resist corrosion. evaporator defrost control with TXV permits low Refrigerant Controls ambient cooling to 30°F. Thermostats—Cooling only and heat/cooling (manual Refrigeration system controls include condenser fan, and automatic change over).Sub-base to match compressor contactor and high pressure switch. High thermostat and locking thermostat cover. and low pressure controls are inherent to the compressor.A factory supplied liquid line drier is Evaporator Defrost Control — See Low Ambient standard.Some models may require field installation. Cooling. ETA us Intertek TRANE Ingersoll Rand (NYSE:IR) advances the quality of life by creating comfortable, sustainable and efficient environments. Our people and our family of brands—including Club Car(`), Ingersoll Rand@,Thermo Kings and TraneF—work together to enhance the quality and comfort of air in homes and buildings; transport and protect food and perishables; and increase industrial productivity and efficiency. We are a global business committed to a world of sustainable progress and enduring results. For more information,visit www.ingersollrand.com. Ingersoll Rand has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. ©2012Ingersoll Rand All rights reserved N 29 Aug 2016 Supersedes4T_M3036G-SUB-IA-EN (December2014) ,--./Ingersoll Rand Bulletin 20-20.2/July 2012 The UNICO System® ENS/NEERINS SPECIFICATIONS M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A Model Number Key M 2430 C L 1 - A - 0 0 0 ® 0 © o 0 Unit Type ® Configuration M=Modular L=Left-hand connection J Nominal Capacity 05 Revision 2430=24000 to 30000 Btu/hr 1,2, 3,etc. (7.0 to 8.8 kW) ' 3036=30000 to 36000 Btu/hr © Coif Style,TXV� without T - A style cal without TXV (8.8 to 10.5 kW) B=C style coil with R410ATXV 3642=36000 to 42000 Btu/hr D=H style coil without TXV (10.5 to 12.3 kW) E=H style coil with R410ATXV 4860=48000 to 60000 Btu/hr (14.0 to 17.5 kW) 00 Paint Color Module Type (blank)=None Figure 1.Refrigerant Coil Module with cut-away(H-style shown). C=Coil 1=White Matching Blower/Heating Modules * A cross-reference chart listing current and past model numbers is Et Coil Matching Blower Matching Hot Evaporator O 0 available at the end of this bulletin. g Water Coil Prefix Module Prefix Module Prefix Packing List M2430CL 1 M2430BL 1 M2430CL 1 Package includes:(1)—Coil Module M3036CLI M3036BLI M3036CLI (1)—Defrost relay M3642CLI M3642BLI M3642CLI (1)—Thermostatic expansion valve(—B and—E models only) M4860CL 1 M4860BL I M4860CL 1 (1)—Liquid Line,3/8-inch (9.5mm)OD (1)—Spacer Module(M4860CLI only) Features General Information • Slant coil for M2430, M3036, M3642 for vertical Unico System designed and built evaporator coil modules or horizontal airflow applications. A-coil for can be easily installed with the matching Unico System M4860. blower modules. See coil/blower match-up table below. . Internally mounted TXV easily accessible The evaporator can be matched to most types of remote condensing units and heat pumps. All coils are designed c Compatible with R-22/407C/410A refrigerants for both heat pump and cooling-only applications. Check the AHRI directory for compatibility, capacity, and o Standard Unico System `latch'system efficiency ratings(www.ahrinet.orf;)• i High efficiency heat transfer surface Temperature limit switch to prevent freezing Certified to UL Standard 1995NUS Conforms to CAN/CSA Standard C22.2 NO.236 A Unico products comply with the European C E regulations that guarantee product safety. 0 Copyright 2012 Unico,Inc. Bulletin 20-20.2—Page 2 Typical Application Some models are supplied with an expansion valve (See Model Number Key on page 1).The expansion valves are suitable for both air-conditioning and heat pump applications. They feature an internal check valve for proper operation in the heating mode. In addition, the valves employ mechanical threaded connections(Chatleff style) for easy installation. All cooling-only valves include an inlet strainer. i i Figure 2. Horizontal installation with Unico System Heating Module and Blower Module Cabinet Construction The cabinet is constructed of 22 gauge (0.030 in, 0.76 mm) galvanized steel with removable access panels on both sides for ease of service. All access panels are secured with slotted hex head washer screws and hardened steel U-clip nuts to prevent stripping. The cabinet is fully lined with closed cell insulation and does not contain fiberglass insulation. Easy snap latches are included for quick field assembly with the matching modules. See dimensional drawing below for additional information Coil Construction Unico-designed coils are constructed of evenly spaced aluminum fins mechanically bonded to copper tubes. The tubes are 3/8" (9 mm) diameter. Full fin collars provide the greatest tube-fin contact for excellent heat transfer. All coils are slanted, except the M4860 models, which feature an `A' shaped coil to provide the maximum amount of heat transfer surface. The coil is pressurized and then factory leak tested. The drain pan is constructed of stainless steel for maximum corrosion protection with a 3/4" (19 mm) FPT drain connection. All refrigerant lines are sweat connections that extend outside of the cabinet. Controls Each coil is supplied with an anti-frost switch mounted directly on the return bends to prevent the formation of ice during cooling operation. For heat pump applications, a 24-volt relay switch is included that bypasses the anti- frost switch during the heating mode. This switch is packed loose inside the module for field installation in the space provided in the control box. 0 Copyright 2012 Unico,Inc. oul'oolun ZIOZ 146uAdo0 (mod s3ON W sH m3e0 rnr li �uenao�sar+aao�aas��v 3sn uoea�ve>a�r vobav nn�nla ao�NMOIS lwll y sccl (*saowalow 'o � a. f- --i wTa ° 0 (eat) acl SC« (sdao l (snl n SMN3do (red ZZ 131tl10 0e•Sl (eaU scu AAMA MIS NOON HOLY1 I letl lwl (a (lH Ill" O -l—"I awl - ------------- I I 1 9fZ + 1 I I 1 NNtl 3WRmw� 3lYNlHLII) 1 1 cffw M31n d01 HUHN ONldld 30 TVAO HOLYI 's[Om Q- V-io3,(laleiedas ploS•osool paddM AX.L• W ) 0"SZ (805) 0'OZ (8f8) 0-ff (S£9) 0"S7 (0-1 O-OZ 0'8Z (b8S) 0"EZ (SI6) 0'9£ R[L) 0"8Z (b8S) 0'£Z El suolsuawiQlamgej ) 0"Of (S£9) 0'SZ (S96) 0'8£ (Z9L) 0"0£ (S£9) 0'SZ V anleA47 f=Im qlw AX L ,aauoU uotsaedxg (9£) 6L (Ef) IL (8Z) 19 (90 8L (Z£) OL (8Z) 09 [(8�.s911 10pta 8mddtgs Poo VOI I- `OLOt-ld`ZZ--d oddy juwSrgaX (61) WE (6I) WE (61) WE (61) 6/£ (61) WE (61) WE I(�)'�J •Ldd`aogaawo3 alasaapaoo 10"ZOIOV lwtzoI0V 10o-6Z0I0V IOo-£ZO10V IWEZOIOV IOo-£ZOIOV -gwnH mM aumq pm611 (9'6) 8/f (S'6) 8/£ (S'6) WE (S'6) 8/f (S'6) 8/£ (S"6) 8/E ((mm)�J Q0 aml pm6lZ (Z'ZZ) 8/L (ZZZ) 8/L (ZZZ) 8/L (Z'ZZ) 8/L (Z-ZZ) 8/L (Z,ZZ) 8/L ((una)`•mJ •Q•0 aml uoganS sa!vouojd 6Io-80800V mo-80800V f10-80800V mo-80800V 610-80800V £Io-80800V VOItrN O 11O� 40o-80 0v0V ""os00V ZOo-80800V b0o-80800V t�0o-80800V Z00-80800V OLOtr�I/ZZ-w OA19AXy iole-dug (LW) OOS (Lt+6£) OOS (Lti6£) OOS (Lb4£) OOS (L6 a 005 (L66f) OOS ((ed�`8lsd] amssaM oBrsaQ 9 9 9 4 b q smol;o mgwnH (0I9) S'SI (019) S'SI (OI9) S"SI (155) bI (ISS) hI ([SS) hl ((w/sug)`'m/sugJ ,S!=G m3 (S'6) 8/f (S'6) 8/E WE (S"6) 8/£ (9.6) 8/f (S'"6) 8/£ ((—)`u!J jalameip agn.L (Z£"0) 84'E (SZ'0) S9"Z (Oro) fl'Z (ZE'0) 86'£ (ZZ-0) trf'Z (OZ-O) EI'Z ((tw)tgJ NOW aae3laH (E"ZI-S-00 (5'01-8'8) (8'8-0'L) (f"Z[�'OI) (S'0I-8.8) (8"S-O'L) RM30`aOli 0"f-S'Z S'Z-0'Z S'f-0'£ 0"E-.97 9'Z-0"7 MS --puoa alquedmoo g I L7Zb9£YV 9-1 L79£OEIN g-I f00£OZN[ H 1'IaZH9£W 6-I L09£0£IN 13-I I�OEYZ[N Q-170Z09£N1 Q-I L79£O£NI Q-I I00£bZW V-1-Dz"£NI V-1 L79£OEW v 1,13O£bZb1t ON lapoy� HOJ 21AIS H IPoJ 01AIS 0 XUI MISSS Men pus 9WM`OsE W:jo;suopeuLqoodg einpow 1loo;ueg6ppa - '-},s^�-�aT:--�-•-:s.-ate: g OBBd—Z-OZ-OZ U11911ne Bulletin 20-20.2—Page 4 - :..`L 3-.:::,�ar�:.�"f+.z,Y7:T;;�'l.'...:�,Y.�4.v"'_•9�s�.s+--5..�'•�+n�'� -r�'f�.c�... Refrigerant Coil Module Specifications for: W860 System Type C Style Coil H Style Coil Model No. M4860CLI-A M4860CLI-D M4860CLI-B M4860CLI-E Compatible Condenser Size 4.0-5.0 4.0-5.0 [Ton,(kW)] (14.0-17.6) (14.0-17.6) Net Face Area [ft(m')] 7.44 (0.69) 7.44 (0.69) Tube diameter [in.,(mm)] 3/8 (9.5) 3/8 (9.5) Fin Density [fins/in.,(fins/m)] 14 (551) 14 (551) Number of rows 3 4 Design Pressure [psig,(kPa)] 500 (3447) 500 (3447) TX Valve R-22/R407C A00808-005 A00808-0OS Evaporator Part No. R410A A00808-015 A00808-0IS Coil Suction line O.D. [in.,(mm)] Properties Liquid line OD [in.(mm)] 3/8 (9.5) 3/8 (9.5) Liquid Line Part Number A01044-001 A01045-001 Condensate Connection,FPT [in.,(mm)] 3/4 (19) 3/4 (19) Refrigerant Type R-22,R407C, R-22,R407C, R4 10A R4 10A Coil Shipping Weight [lbs.,(kg)] 88 (40) 89 (41) Expansion Device' TXV with internal TXV with internal Check Valve Check Valve •TXV shipped loose. TOP VIEW DETAIL OF PIPING F F' CONDENSATE ' UNEDRAIN 3.46 :SLjCTt L (88) �-- --- - UNF r,.73 1 1.41 (44) LATCH 5.88 1.63 ; HOOK (149) y�(41) FRONT VIEW SIDE VIEW L, -t 5 (127) 17.50 Z W AIR FLOW (445) 61eo>a emsISP— + Modido 9.50(241) V 5 32.23(819) (127) 0 ( �— C3 8,00 (965) 3.00 .�6.00 -18.00--- 1965) (/6) (152) (457) -- UNIT SHOWN FOR HORIZONTALAIRFLOW ARRANGEMEN7. ALL DIMENSIlN3S IN INCHES(mm) 'Spacer Module is shipped wth MC486OC/H Coding Module only ©Copyright 2012 Unico,Inc. - -- � 1 Bulletin 20-20. /_October 2012 I-r7_1%M11URNMICN018yalow ENSINEERINS SPECIFICATIONS ..LJ M SERIES BLOWER MODULE Model Number M 2430 B L 1 - ST2 1 5 2(2 ( ® D © O O BMn�T e ® nfi coguration t L=Left-band connection 2 Nominal 0 Capacity 2430=24000 tt0 o 3000 Btulhr ©1,2,3l etc, (7.0 8.8 3036=30000 to 600 ©pVW9r SUP ft Motor Type Btu/hr ST2=1/ M8_240,single-speed (8.8 to 10.5 k kW) EC1=1J60✓120,variable-speed 3642=36000 to 42000 Btuthr EC2=1/50-80/240,variable-speed (10.5 to 12.3 kW) 4860=48000 to 60000 Bh t1r (2)Paint Option (14.0 to 17.5 kW) (��=N� O Module Type 1=White B=Blower Module * A cross-reference chart listing current and past model numbers is Figure 1.Typical Blower Module with cutaway revealing available at the end of this bulletin. motor(-ST2 Model) General Information Typical Application The Unico System patentedl modular blowers are designed for use with the Unico System small-duct high- velocity (SDHV) system. The blowers exceed the U.S. Department of Energy requirements for SDHV systems requiring a minimum external static pressure of 1.2 inches of water(0.3 kPa)at the rated airflow when installed with the compatible Unico cooling module. All cooling modules are available in Heat Pump, Chilled Water and refrigerant configurations. Matching Heating/Cooling Coil Blower Module t Module M2430BL 1 M2430CL 1-* M3036BL1 M3036CL1-* h M3642BL1 M3642CL1-* M4860BL 1 M4860CL 1-* Standard Modules Note:Model numbers listed above may not include the latest revision code. Figure 2.Attic Installation with Unico System Cooling Module,Heating Applications For air-conditioning, the rated airflow is 250 CFM per nominal* ton (34 L/kW-s) and for heat pumps it is 275 ,.•=o CFM per nominal ton(37 L/kW-s). For proper operation, CERTIFIED TO UL STD 1995 we do not recommend flow rates less than 200 CFM per c CONFORMS TO CAN/CSA STD C22.2 nominal ton (27 LAW-s). Refer to the Blower Capacity NO.236 Data tables and 81037 graphs later in this bulletin for blower performance data showing static pressure and amperage versus air flow. U.S.Patent No.5,277,036 "Nominal'refers to the nameplate size of the condensing unit or heat pump. Note—Dimensions and specifications are subject to change without notice. 0 Copyright 2012 Unico,Inc. Bulletin 20-20.1 —Page 2 Motor and Control Box Options Balanced wheels (ST and EC) - All blower wheels are The blower module comes with several different motor individually balanced. and control options as follows. Direct drive motor (ST and EC) — The blower wheel is OLS (Old-Style)—Most economical, single-speed motor, mounted directly to the motor shaft to improve drive simple sequencer fan relay, transformer, and efficiency and lower costs. terminal block. No frills. Shaft key (ST and EC)—The blower wheel is attached to ST (Standard Model)— Very economical. Same as the the motor shaft using a square keyway which is more OLS, but additionally includes a variable speed secure than a simple set screw. controller for ventilation. Quick motor replacement (QMR) (ST and EC) — The EC (Electronically Commutated) — Part of the Unico QMR feature is a quick twist-and-lock motor mount for Green Series. This control box includes a super- easy maintenance. The motor is mounted to the inlet ring efficient variable speed EC motor with the Unico which is attached to the blower housing with six screws SCB (S.M.A.R.T. Control Board). Features user- through twist-lock keyholes. When service is required by programmable speeds. the motor or the wheel, the entire assembly may be removed as a whole. See Figure 3 for details. Control Board Features and Settings Control Box Configuration ST EC Balanced wheels ✓ ✓ _ Direct drive motor ✓ ✓ Shaft key connection ✓ ✓ Quick motor replacement(QMR) ✓ ✓ Separate control box ✓ ,� Control voltage transformer ✓ ✓ • Screw terminal connections ✓ ✓ ° Heat pump AFS bypass ✓ ✓ 110° "a` Boiler relay ss ✓ Figure 3. Quick motor replacement(QMR)feature. Number of modes of operation 2 6 Separate control box (ST and EC) — The control box is Adjustable low airflow mode ✓ ✓ separate from the cabinet (ships loose) so that is may be Adjustable restrictor plate ✓ mounted to the top or front of the cabinet, depending on Efficient ventilation mode ✓ which is more convenient. Knockout and starter holes for Point-to-point wiring ✓ the screws are provided to assist in mounting. Control Electric heater fan interlock ✓ boards include the following features: Electric heater stage 3 lockout protection ✓ Control voltage transformer (ST and EC)—A 50VA 24- Chilled water relay ✓ volt transformer which provides control voltage power to Fan cycling ✓ the thermostat, electric heaters, and other optional EAC,ERV,or HRV relay ✓ equipment. Potable water circulation ✓ Screw terminal connections (ST and EC) — Terminal Humidifier compatibility ✓ blocks with large screws and wire washers to securely UniChiller Leader/Follower control ✓ connect the control wires. Soft-start and soft-stop ✓ Constant airflow ✓ Heat pump AFS bypass (ST and EC)—Removes the anti- Low airflow indicator ✓ frost switch (AFS) from the circuit during heat pump Preset airflow rate ✓ heating mode which eliminates nuisance shutdowns Laptop configurable during defrost mode. ✓ Laptop troubleshooting ✓ Boiler relay (EC) — The SCB includes a separate dry- Optimized for zone damper systems ✓ contact relay that can be used to turn on the boiler, boiler Optimized for efficiency and sound ✓ pump, or hot water coil valve. The ST control box '•The ST control box includes room for a relay to be added. includes room for a relay to be added. 0 Copyright 2012 Unico,Inc Bulletin 20-20.1 —Page 3 Modes of operation(ST and EC)—The ST control board when needed. The user may choose whether the fan with allows for high and low airflow modes. The EC control humidifier operates at the high or low-heat airflow board has 6 modes (Fan-Only, Low-Cool, High-Cool, setting. Low-Heat,High-Heat,and Emergency-Heat). Adjustable low airflow mode (ST and EC) — The ST allows ows lone air handler(Leader) to control the �niChifeature r control board allows the user to adjust the low airflow, mode of operation and force all other air handlers to be but it is not very efficient. The EC board allows the user dependent(Follower(s)). to program the airflow for each mode, maintaining high efficiency. Soft-start and soft-stop .� ft p (EC) — For quieter operation, the nit Adjustable restrictor plate (ST) —Our patented restrictor v ice ersay cps the motor from stop to full speed, and plate provides a low-cost solution to finely tune the airflow when using a single speed motor. The adjustable Constant airflow 'rf1 (EC) — The EC control board will restrictor plate is accessible from the outside front of the deliver the airflow requested without requiring the user to unit even with the duct installed. measure the amperage, or make any other adjustments to Point-to-point wiring (EC) — The control boards have the duct system. separate terminals for the thermostat, electric heater, Low airflow indicator (EC) — The S.M.A.R.T. control outdoor condenser, and other options for easy wiring and board (SCB) includes an indicator light that signals the troubleshooting. user if the desired airflow is not being met.This is usually caused by a restrictive duct system or too few outlets.Electric heater fan interlock (EC) — This is a safety feature that prevents the heater from energizing when Pre-set airflow rate (EC) — The SCB is pre-programmed there is low or no airflow. This prevents the heating with two different air flow rates for High-Cool. These elements from overheating, which can severely reduce rates are based on the nominal tonnage of the unit(See the their useful life. Applications section) and can be selected with a board mounted switch. Each of the six different airflow control Electric heater stage 3 lockout protection (EC) — The modes are a fixed percentage of this selected airflow. control board includes a lockout feature to prevent the third stage of the electric heater from turning on if the Laptop configurable(EC)—The airflow for each mode of heat pump is also on. This prevents nuisance shutdowns operation is adjustable to any value between the blower from overheating the electric heater. This feature can be minimum and maximum using the ECMconfig software added to the ST control box by using an outside (available for download at www.unicosystem.com)and an thermostat. ordinary USB cable. Chiller water relay (EC- The control box includes a Laptop troubleshooting (EC)— The ECMconfig software separate dry-contact relay(ColdW)to turn on a chiller or will also provide the user with feedback reporting the zone pump. actual airflow, motor speed, communications status etween the control board Fan cycling(EC)—The control board includes a separate various puts and outputs and the motor, and the state of switch to provide periodic cycling of the fan to reduce the chance for water to collect in the ducts if located in a cold Optimized for zoning with hydronic systems (EC) — The space and not used, or to provide periodic fresh air if ECMconfig software provides an additional feature that connected to a fresh air source. allows the user to limit the maximum motor speed. This prevents excessive motor ramping and eliminates the need EAC, ERV, or HRV relay (EC) — For the optimum in for bypass loops and pressure switch controls when zone indoor air quality,the control board includes a dry-contact dampers are closed. It reduces noise at the outlets caused relay to turn on an electronic air cleaner, energy recovery by the blower ramping to maintain a constant airflow with ventilator, or heat recovery ventilator any time the fan is fewer outlets. Do not set the maximum airflow to on. approximate constant static pressure with a single speed condensing unit. Refer to Unico Technical Bulletin 110 Potable water circulation (EC) — For improved health on zoning for more information. safety, the control board provides a switch-selectable feature to turn on the boiler pump periodically(if installed Optimized for efficiency and sound(EC)—The EC control as part of a domestic water system) to prevent the uses the lowest motor speed that can achieve the required formation of stagnant water. airflow, which minimizes noise and maximizes electrical Humidifier compatibility (EC) — The control board efficiency. includes the ability to connect a humidistat and a humidifier so that the humidistat turns on the humidifier 0 copyright 2012 unico.Inc. Bulletin 20-20.1 —Page 4 Cabinet Construction All blower modules feature electrical connections and The cabinet is constructed of 22 gauge (0.7mm) service access panels on the left-hand side of the unit galvanized steel with removable access panels installed when viewing the return with the airflow at your back. on both sides for ease of service. All access panels are Right hand blowers are available upon request. In this secured with slotted hex head washer screws and case, the blower discharge opening is near the top of the hardened steel U-clip nuts to prevent stripping. The cabinet. cabinet is fully insulated with closed cell insulation.There is no exposed fiberglass inside the cabinet. See dimension drawing. Dimensional Data TOP VIEW f" A o0 LATCH CATCH rRI V 1 VIE V SI�MEW 9.55 ALTERNATE —(243)—� CONTROL BOX 7.55 CONTROL BOX LOCATION �—(192)---� KNOCKOUTS 4.29 RESTRICTOR lJ � � PLATE (Notused with EC motor) inj,...;, AIR FLOW UJ 175OUTLET 15.5OPENING(FULL) (162) C I ( XX ID'Width 1.0(25) B ---13.75 PLENUM ADAPTER ALL DIMENSIONS IN inches(mm) (SOLD SEPARATELY) Model No. W(5RAI M3036BLI M3642BLI M4860BL1 A 30.00 (762) 38.00 (965) 38.00 (965) Dimensions B 7.24 (184) 7.16 (182) 9.92 (252) [in•(mmA C 11.38 (289) 15.40 (392) 14.00 (356) D 28.00 (711) 36.00 (915) 36.00 (915) 0 Copyright 2012 Unco,Inc --- _ CITY OF RYE BUILDING DEPARTMENT APPLICATION FOR MECHANICAL PERMIT Date: Location of work: Tax ID# Owner: Owner's Address: Application is hereby made to the Building Department for the issuance of a Mechanical Installation Permit to install equipment, wiring or plumbing as described herein. The applicant agrees to comply with all applicable laws, ordinances, codes, rules, regulations and directives of the Building Inspector. Contractor: Contractor's Address: Telephone: Westchester County License# PLUMBING New Structure: Addition: Alteration: Number of Traps: Is Sewer connection to Main Line Required: Description of Work: • $200.00 Minimum fee for New Work: • $ 5.00 Additional for each fixture above (5)five • $100.00 Additional for Sewer connection or Storm Water Drain connection All Waste Pipe must be tested and approved by the Building Inspector GAS or HEATING EQUIPMENT New Equipment: Replacement: Location: Hot Water: Steam: Forced Air: Oil Tank: Location of Oil Tank: • $200.00 New Equipment installation or replacement All work must be inspected and approved by the Building Inspector 7RWE' Submittal f Split System Cooling 3.0 Ton 4TTR3036H1000N -= 1 1 TAG: I SAFETY WARNING Only qualified personnel should install and service the equipment.The installation,starting up,and servicing of heating,ventilating,and air-conditioning equipment can be hazardous and requires specific knowledge and training.Improperly installed,adjusted or altered equipment by an unqualified person could result in death or serious injury.When working on the equipment,observe all precautions in the literature and on the tags,stickers,and labels that are attached to the equipment. August 2016 4TTR3036H-SUB-1 B-EN AR)Ingersoll Rand. UNNE' B III SERVICE PANEL C ELECTRICAL AND REFRIGERANT COMPONENT CLEARANCES PER PREVAILING CODES TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR AT LEAST 1524(5 FEET) ABOVE UNIT.UNIT SHOULD BE PLACED SO ROOF RUN-OFF WATER DOES NOT POUR DIRECTLY ON UNIT AND SHOULD BE AT LEAST 305(12")FROM WALL AND ALL SURROUNDING SHRUBBERY ONTWO SIDES. OTHERTWO SIDES UNRESTRICTED T i ELECTRICAL SERVICE— K PANEL 25 111 22.2(7/8)DIA.HOLE LOW VOLTAGE 28.6(1-1/8)DIA.K.O.WITH 22.2(7/8)DIA.HOLE IN CONTROL BOX BOTTOM FOR ELECTRICAL POWER SUPLY LIQUID LINE SERVICE VALVE, E" I.D.FEMALE BRAZE CONNECTION WITH 1/4"SAE � FLARE PRESSURETAP FITTINGS G FIG.1 K0.FOR ALTERNATE ELECTRICAL ROUTING From Dwg.D152898 GAS LINE 1ATURN BALL SERVICE VALVE, "D" I.D.FEMALE BRAZED CONNECTION WITH 1/4"SAE FLARE PRESSURE TAP FITTING.A Model Base A B C D E F G H J K 4TTR3036H 3 730 829 756 3/4 3/8 137 79 197 60 508 (28-3/4) (32-5/8) (29-3/4) (5-3/8) (3-1/8) (7-3/4) (2-3/8) (20) SOUND POWER LEVEL Model A-Weighted Sound Full Octave Sound Power[dB] Power Level[dB(A)] 63 Hz* 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 HITT 8000 Hz 4TTR3036G 68 74.7 65.0 65.2 66.4 63.6 58.7 56.3 52.8 Note: Rated in accordance with AHRI Standard 270-2008*For reference only66 2 4TTR3036H-SUB-1 B-EN 0 MANE* Product Specifications OUTDOOR UNIT(a)(b) 4TTR3036H1000N W Certified in accordance with the Air-Source Unitary Air-conditioner POWER CONNS.—V/PH/HZ(c) 208/230/1/60 Equipment certification program,which is based on AHRI standard 210/240. MIN.BRCH.CIR.AMPACITY 18 (b) Rated in accordance with AHRI standard 270. BR.CIR.PROT.RTG.—MAX.(AMPS) 30 (0 Calculated in accordance with Natl.Elec.Codes.Use only HACR circuit breakers or fuses. COMPRESSOR CLIMATAUFF@-SCROLL (a) This value shown for compressor RLA on the unit nameplate and on NO.USED—NO.STAGES 1—1 this specification sheet is used to compute minimum branch circuit ampacity and max.fuse size.The value shown is the branch circuit VOLTS/PH/HZ 208/230/1/60 selection current. R.L.AMPS(a)—L.R.AMPS 14.1—75 W No means no start components.Yes means quick start kit components.PTC means positive temperature coefficient starter. FACTORY INSTALLED M Standard Air—Dry Coil—Outdoor START COMPONENTS(e) (9) This value approximate.For more precise value see unit nameplate. NO (h) Max.linear length 60 ft.;Max.lift—Suction 60 ft.;Max.lift—Liquid INSULATION/SOUND BLANKET NO 60 ft.For greater length consult refrigerant piping software Pub.No. COMPRESSOR HEAT NO 32-3312-0*(*denotes latest revision). OUTDOOR FAN PROPELLER DIA.(IN.)—NO.USED 23—1 TYPE DRIVE—NO.SPEEDS DIRECT—1 CFM @ 0.0 IN.W.G.(f) 2900 NO.MOTORS—HP 1-1/8 MOTOR SPEED R.P.M. 825 VOLTS/PH/HZ 200/230/1/60 F.L.AMPS 0.7 OUTDOOR COIL—TYPE SPINE FINTM ROWS—F.P.I. 1-24 FACE AREA(SQ.FT.) 12.89 TUBE SIZE(IN.) 3/8 REFRIGERANT LBS.—R-410A(O.D.UNIT)(9) 4 LBS.,13 OZ FACTORY SUPPLIED YES LINE SIZE—IN.O.D.GAS(h) 3/4 LINE SIZE—IN.O.D.LIQ. 3/8 CHARGING SPECIFICATIONS SUBCOOLING 10*F DIMENSIONS H X W X D CRATED(IN.) 34 x 30.1 x 33 WEIGHT SHIPPING(LBS.) 175 NET(LBS.) 147 4TTR3036H-SUB-1 B-EN 3 0 MWE' Mechanical Specification Options General Compressor The Outdoor Units are fully charged from the factory The compressor features internal over temperature, for up to 15 feet of piping.This unit is designed to pressure protection and total dipped hermetic motor. operate at outdoor ambient temperatures as high as Other features include:Centrifugal oil pump and low 115°F.Cooling capacities are matched with a wide vibration and noise. selection of air handlers and furnace coils that are AHRI Condenser Coil certified.The unit is certified to UL 1995.Exterior is designed for outdoor application. The outdoor coil provides low airflow resistance and efficient heat transfer.The coil is protected on all four Casing sides by louvered panels. Unit casing is constructed of heavy gauge,galvanized Low Ambient Cooling steel and painted with a weather-resistant powder paint finish on all louvered panels and the fan top panel.The As manufactured,this system has a cooling capacity to corner panels are prepainted.All panels are subjected 55°F.The addition of an evaporator defrost control to our 1,000 hour salt spray test.The base is made of a permits operation to 40°F.The addition of an CMBP-G30 weatherproof material to resist corrosion. evaporator defrost control with TXV permits low Refrigerant Controls ambient cooling to 30°F. Refrigeration system controls include condenser fan, Thermostats—Cooling only and heat/cooling (manual and automatic change over). Sub-base to match compressor contactor and high pressure switch. High thermostat and locking thermostat cover. and low pressure controls are inherent to the compressor.A factory supplied liquid line drier is Evaporator Defrost Control — See Low Ambient standard.Some models may require field installation. Cooling. C us Intertek TRINE* Ingersoll Rand (NYSE:IR) advances the quality of life by creating comfortable, sustainable and efficient environments. Our people and our family of brands—including Club Car®, Ingersoll Rand@,Thermo King@ and Trane@—work together to enhance the quality and comfort of air in homes and buildings; transport and protect food and perishables; and increase industrial productivity and efficiency. We are a global business committed to a world of sustainable progress and enduring results. For more information,visit www.ingersollrand.com. Ingersoll Rand has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. ©2012 Ingersoll Rand All rights reserved SUB 29 Aug 2016 Supersedes 4TTR3036G-SUB-IA-EN (December 2014) "Hingersoll Rand Bulletin 20-20.2/July 2012 Syg im® fN61NEfR►N6 SPECIFICATIONS M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A Model Number Key M2430C L 1 - A - 0 © 0 ® O © 0 T Unit Type ® Configuration M=Modular L=Left-hand connection 0 Nominal Capacity 0 Revision 2430=24000 to 30000 Btu/hr 1,2,3,etc. (7.0 to 8.8 kW) © Coil Style,TXV Option 3036=30000 b 36000 Btu/hr A=C style coil without TXV (8.8 to 10.5 kW) B=C style coil with R410ATXV 3642=36000 to 42000 Btu/hr D=H style coil without TXV (10.5 to 12.3 kW) E=H style coil with R410ATXV 4860=48000 to 60000 Btu/hr (14.0 to 17.5 kW) OO Paint Color (blank)--None Figure 1.Refrigerant Coil Module with cut-away(H-style shown). J Module Type 1=White C=Coil Matching Blower/Heating Modules A cross-reference chart listing current and past model numbers is Evaporator Coil Matching Blower Matching Hot available at the end of this bulletin. g Water Coil Prefix Module Prefix Module Prefix Packing List N42430CL1 M2430BLI M2430CLI Package includes:(1)—Coil Module M3036CLI M3036BLI M3036CLI (1)—Defrost relay M3642CL 1 M3642BL 1 M3642CL 1 (1)—Thermostatic expansion valve(—B and—E models only) M4860CL I M4860BL 1 M4860CL 1 (1)—Liquid Line,3/8-inch(9.5mm)OD (1)—Spacer Module(M4860CL I only) Features General Information Slant coil for M2430, M3036, M3642 for vertical Unico System designed and built evaporator coil modules or horizontal airflow applications.A-coil for can be easily installed with the matching Unico System M4860. blower modules. See coil blower match-up table below. • Internally mounted TXV easily accessible The evaporator can be matched to most types of remote condensing units and heat pumps. All coils are designed a Compatible with R-22/407C/4I OA refrigerants for both heat pump and cooling-only applications. Check the AHRI directory for compatibility, capacity, and Standard Unico System `latch'system efficiency ratings(www.ahrinet.org). f High efficiency heat transfer surface • Temperature limit switch to prevent freezing Affous Certified to UL Standard 1995 Conforms to CAN/CSA Standard C22.2 NO.236 Unico products comply with the European C E� regulations that guarantee product safety. — 0 Copyright 2012 Unico,Inc. Bulletin 20-20.2—Page 2 Typical Application Some models are supplied with an expansion valve (See Model Number Key on page 1). The expansion valves are suitable for both air-conditioning and heat pump applications. They feature an internal check valve for proper operation in the heating mode. In addition, the valves employ mechanical threaded connections(Chatleff style) for easy installation. All cooling-only valves include an inlet strainer. i Figure 2. Horizontal installation with Unico System Heating Module and Blower Module Cabinet Construction The cabinet is constructed of 22 gauge (0.030 in, 0.76 mm) galvanized steel with removable access panels on both sides for ease of service. All access panels are secured with slotted hex head washer screws and hardened steel U-clip nuts to prevent stripping. The cabinet is fully lined with closed cell insulation and does not contain fiberglass insulation. Easy snap latches are included for quick field assembly with the matching modules. See dimensional drawing below for additional information Coil Construction Unico-designed coils are constructed of evenly spaced aluminum fins mechanically bonded to copper tubes. The tubes are 3/8" (9 mm) diameter. Full fin collars provide the greatest tube-fin contact for excellent heat transfer. All coils are slanted, except the M4860 models, which feature an `A' shaped coil to provide the maximum amount of heat transfer surface. The coil is pressurized and then factory leak tested. The drain pan is constructed of stainless steel for maximum corrosion protection with a 3/4" (19 mm) FPT drain connection. All refrigerant lines are sweat connections that extend outside of the cabinet. Controls Each coil is supplied with an anti-frost switch mounted directly on the return bends to prevent the formation of ice during cooling operation. For heat pump applications, a 24-volt relay switch is included that bypasses the anti- frost switch during the heating mode. This switch is packed loose inside the module for field installation in the space provided in the control box. 0 Copyright 2012 Unico,Inc. m Bulletin 20-20.2- Page 3 Refrigerant Coll Module Specifications for: M2430, M3036 and M3642 System Type C Style Coil H Style Coil Model No. M2430CLI-A M3036CLl A M3642CLI-A M2430CL1-D M3036CL1-D M3642CLI-D M2430CL1-B M3036CL1-B M3642CL1-B M2430CL1-E M3036CLI E M3642CL1-E Compatible Condenser Size 2.0-2.5 2.5-3.0 3.0-3.5 2.0-2.5 2.5-3.0 3.0-3.5 ITO4(kW)] (7.0 8.8) (8.8-10.5) (]0.5-12.3) (7. _8.8) (8.8-10.5) (10.5-12.3) Net Face Area (ft(m')] 2.13 (0.20) 2.34 (0.22) 3.48 (0.32) 2.13 (0.20) 2.65 (0.25) 3.48 (0.32) Tube diameter tin.,(mm)) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) 3/8 Fin Density [fins/in.,(fins/m)] 14 (551) 14 (551) 14 (551) 15.5 (610) 15.5 (610) I5.5 (610) Number of rows 4 4 4 6 6 6 Design Pressure [psig,(kPa)] 500 (3447) 500 (3447) 500 (3447) 500 (3447) 500 (3447) 500 (3447) Evaporator TX Valve R-22/R407C A00808-002 A00808-004 A00808-004 A00808-002 A00808-004 A00808-004 Coil Part No. R410A A00808-013 A00808-014 A00808-014 A00808-013 A00808-014 A00808-014 Properties Suction line(J.D. [in.,(mm)] Liquid line OD [in. Liquid Line Part Number A01023-001 A01023-001 A01023-001 A01024-001 A01024 001 A01024 001 Condensate Connection,FPT 3/4 (19) 3/4 (19) 3/4 119) VA[in (-A Refrigerant Type R-22,R407C,R410A Coil Shipping Weight 60 (28) 70 (32) 78 (36) 61 (28) 71 33 Ilbs.,(kg)) ( ) 79 (36 ) Expansion Device* TXV with internal Check Valve A 25.0 (635) 30.0 (762) 38.0 (965) 25.0 (635) 30.0 (762) 38.0 (965) Cabinet Dimensions B 23.0 (584) 28.0 (711' 36.0 (915) 23.0 (584) 28.0 (711) 36.0 (915) C 20.0 (508) 25.0 (635) 33.0 (838) 20.0 (508) 25.0 (635) 33.0 (838) •TXV shipped loose.Sold separately for-A,-D models. LATCH DETAIL OF PIPING KEEPER TOP VIEW s � UQ= - ----------- -12 1 TOP OPENING LIE LINE I (ALTERNATE WTLET) CONDENSATE E TtAN I I I + -� I I + Z35 I ( p0) - -- --_ -_--- -- -I 192- 3B2 250 1,1- I M) Psl LATCH HOOK SIDE VIEW FRONT VIEW 1175 ate) (TOPONENINQ u AIR FLOW j�OsFbwooIItLET /L 1445) 1.0095) 11.15 Typ (�) O c c,ran r AI- V WiSh� (BOTTOM OPENING - -13.75(3l9)- -- 4 R R ALL RU FOR INDIDMAI A6,RON ARRATIGEIuEM USE ALTERNATE OPENINGS FOR yERO(/PL p/jPPN(PpfNl ALL GO.ENLSION75IN aX7E5(mm) ©Copyright 2012 Unico, Inc. - Bulletin 20-20.2—Page 4 - Thta*++�p+s+c.-.y>F-"` •R+� brave n'a�a,.-ce>�.*- - arsa�-u.nv�.`�4.i,-":��:'114..�'1: -. . Refrigerant Coil Module Specifications for: 11114W System Type C Style Coil H Style Coil Model No. M4860CLI-A M4860CLI-D M4860CLI-B M4860CLI-E Compatible Condenser Size 4.0-5.0 4.0-5.0 [Ton,(kW)] (14.0-17.6) (14.0-17.6) Net Face Area [fl(m1)] 7.44 (0.69) 7.44 (0.69) Tube diameter [in-,(mm)] 3/8 (9-5) 3/8 (9.5) Fin Density [fins/in.,(fins/m)] 14 (551) 14 (551) Number of rows 3 4 Design Pressure [prig,(kPa)] 500 (3447) 500 (3447) TX Valve R-22/R-407C A00808-005 A00808-005 Evaporator Part No. R 110A A00808-015 A00808-015 Coil Suction line O.D. [in.,(mm)] 7/8 (22.2) 7/8 (22.2) Properties Liquid line OD [in.(mm)] 3/8 (9.5) 3/8 (9.5) Liquid Line Part Number A01044-001 A01045-001 Condensate Connection,F I- [m.,(mm)l 3/4 (19) 3/4 (19) Refrigerant Type R-22,R407C, R-22,R407C, R4 10A R-410A Coil Shipping Weight [lbs.,(kg)] 88 (40) 89 (41) Expansion Devices TXV with internal TXV with internal TXV shipped loose. Check Valve Check Valve • TOP VIEW DETAIL OF PIPING 7.51 :. CONDENSATE Ulic /DRAIN ` 3.4 121C T)ON � 173 � laa) (�) I LATCH 5." 163 HOOK - ---_.(149)-- -~-(41 FRONT VIEW SIDE VIEW 5 (127) — � O z U 0 air W AIR FLOW z 11 S 0 3223(819) (tom) . t 38.00 _ 3.00 ' III (965) -----_--•'•- —(76) &OD -- 18.00 --_ --- Il (457) LUT SHOWN FOR HORIZONTAL AIRFLOW ARRANGEMENT ALL DwEt151071S IN INCHES(mm) 'Spacer Module is snipped mph W4860GH Coohng MDdide mty 0CcpyrigM 2012 UNco,Inc. Bulletin 20-20.1/October 2012 NLIkLcojoyalar ENGINEERING SPECIFICATIONS M SERIES BLOWER MODULE Model Number M 2430 B L 1 - ST2 1 O OO 03 45 © O �1 unit Type ®Configuration M=Modular L=Left-hand connection �2 Nominal Capacity ©Revision 2430=24000 to 30000 BtuRv 1,2,3,etc. (7.0 to 8.8 kW) ©power Supply,Motor Type 3036=30000 to 36000 Btu/hr (8.8 to 10.5 kWj ST2=1/60/208-240,single-speed EC1=1 3642=36000 to 42000 Btu/hr t60/120,variable-speed (10.5 to 12.3 kW) EC2=1/50�0/240,variable speed 4860=48000 to 60000 Btu/hr (2)Paint Option (14.0 to 17.5 kW) (Blank)=None 0 Module Type 1=White B=Blower Module ' A cross-reference chart listing current and past model numbers is Figure 1.Typical Blower Module with cutaway revealing available at the end of this bulletin. motor(-ST2 Model) General Information _Typical Application The Unico System patented& modular blowers are _ designed for use with the Unico System small-duct high- velocity (SDHV) system. The blowers exceed the U.S. Department of Energy requirements for SDHV systems requiring a minimum external static pressure of 1.2 inches of water(0.3 kPa)at the rated airflow when installed with the compatible Unico cooling module. All cooling modules are available in Heat Pump, Chilled Water and refrigerant configurations. Blower Module Matching Heating/Cooling Coil Module f M2430BL 1 M2430CL 1-* M3036BL 1 M3036CL 1-* M3642BL 1 M3642CL 1-* M4860BL 1 M4860CL 1-* Standard Modules Note:Model numbers listed above may not include the latest revision code. Figure 2.Attic Installation with Unico System Cooling Module,Heating Applications For air-conditioning, the rated airflow is 250 CFM per nominal' ton (34 L/kW-s) and for heat pumps it is 275 CFM per nominal ton (37 LAW-s). For proper operation, CERTIFIED TO UL STD 1995 we do not recommend flow rates less than 200 CFM per cSus CONFORMS TO CAN/CSA STD C22.2 nominal ton (27 L/kW-s . Refer to the NO. 236 ) Blower Capacity 8 Data tables and graphs later in this bulletin for blower performance data showing static pressure and amperage 1 U.S.Patent No 5,277,036 ---- --.-.._---- -. - __ versus air flow. "Nominal"refers to the nameplate size of the condensing unit or heat pump. Note—Dimensions and specifications are subject to change without notice. 8 Copyright 2012 Unico,Inc Bulletin 20-20.1 —Page 2 • u,�.ar..�-� .,-;..-ter _ �.�-��-� .:r.o r.+�mac.zs_s-s:..:y.-•-...... Motor and Control Box Options Balanced wheels (ST and EC) - All blower wheels are The blower module comes with several different motor individually balanced. and control options as follows. Direct drive motor (ST and EC) - The blower wheel is OLS (Old-Style)-Most economical, single-speed motor, mounted directly to the motor shaft to improve drive simple sequencer fan relay, transformer, and efficiency and lower costs. terminal block. No frills. Shaft key (ST and EC)- The blower wheel is attached to ST (Standard Model)- Very economical. Same as the the motor shaft using a square keyway which is more OLS, but additionally includes a variable speed secure than a simple set screw, controller for ventilation. Quick motor replacement (QMR) (ST and EC) - The EC (Electronically Commutated) - Part of the Unico QMR feature is a quick twist-and-lock motor mount for Green Series. This control box includes a super- easy maintenance. The motor is mounted to the inlet ring efficient variable speed EC motor with the Unico which is attached to the blower housing with six screws SCB (S.M.A.R.T. Control Board). Features user- through twist-lock keyholes. When service is required by programmable speeds. the motor or the wheel, the entire assembly may be removed as a whole. See Figure 3 for details. Control Board Features and Settings Pkey Configuration ST EC ' ls ✓ ✓ tor ✓ ✓ --� v ection ✓ ✓ Quick motor replacement(QMR) ✓ ✓ Separate control box ✓ Control voltage transformer ✓ ✓ Screw terminal connections ✓ ✓ \� Heat pump AFS bypass ✓ ✓ ILM282a Boiler relay ** Figure 3. Quick motor replacement(QMR)feature. Number of modes of operation 2 6 Separate control box (ST and EC) - The control box is Adjustable low airflow mode ✓ ✓ separate from the cabinet (ships loose) so that is may be Adjustable restrictor plate ✓ mounted to the top or front of the cabinet, depending on Efficient ventilation mode ✓ which is more convenient. Knockout and starter holes for Point-to-point wiring ✓ the screws are provided to assist in mounting. Control Electric heater fan interlock ✓ boards include the following features: Electric heater stage 3 lockout protection ✓ Control voltage transformer (ST and EC)- A 50VA 24- Chilled water relay ✓ volt transformer which provides control voltage power to Fan cycling ✓ the thermostat, electric heaters, and other optional EAC,ERV,or HRV relay ✓ equipment. Potable water circulation ✓ Screw terminal connections (ST and EC) - Terminal Humidifier compatibility ✓ blocks with large screws and wire washers to securely UniChiller Leader/Follower control ✓ connect the control wires. Soft-start and soft-stop ✓ Constant airflow ✓ Heat pump AFS bypass (ST and EC)- Removes the anti- Low airflow indicator ✓ frost switch (AFS) from the circuit during heat pump Preset airflow rate heating mode which eliminates nuisance shutdowns ✓ during defrost mode. Laptop configurable ✓ Laptop troubleshooting ✓ Boiler relay (EC) - The SCB includes a separate dry- Optimized for zone damper systems ✓ contact relay that can be used to turn on the boiler, boiler Optimized for efficiency and sound ✓ pump, or hot water coil valve. The ST control box •'The ST control box includes room for a relay to be added. includes room for a relay to be added. ®Copydgh12012 Unico.Inc -----"----- -- - Bulletin 20-20.1 —Page 3 Modes of operation (ST and EC)—The ST control board when needed. The user may choose whether the fan with allows for high and low airflow modes. The EC control humidifier operates at the high or low-heat airflow board has 6 modes (Fan-Only, Low-Cool, High-Cool, setting. Low-Heat,High-Heat,and Emergency-Heat). s feae Adjustable low airflow mode (ST and EC) — The ST allows gone air handler(Leader) to control the UUniChilturler control board allows the user to adjust the low airflow, mode of operation and force all other air handlers to be but it is not very efficient. The EC board allows the user dependent(Follower(s)). to program the airflow for each mode, maintaining high efficiency. Soft-start and soft-stop (EC) — For quieter operation, the Adjustable restrictor plate (ST) —Our patented restrictor vie ve say ramps the motor from stop to full speed, and plate provides a low-cost solution to finely tune the airflow when using a single speed motor. The adjustable Constant airflow'rj1 (EC) — The EC control board will restrictor plate is accessible from the outside front of the deliver the airflow requested without requiring the user to unit even with the duct installed. measure the amperage, or make any other adjustments to Point-to-point wiring (EC) — The control boards have the duct system. separate terminals for the thermostat, electric heater, Low airflow indicator (EC) — The S.M.A.R.T. control outdoor condenser, and other options for easy wiring and board (SCB) includes an indicator light that signals the troubleshooting. user if the desired airflow is not being met.This is usually caused by a restrictive duct system or too few outlets.Electric heater fan interlock (EC) — This is a safety feature that prevents the heater from energizing when Pre-set airflow rate (EC)—The SCB is pre-programmed there is low or no airflow. This prevents the heating with two different air flow rates for High-Cool. These elements from overheating, which can severely reduce rates are based on the nominal tonnage of the unit(See the their useful life. Applications section) and can be selected with a board mounted switch. Each of the six different airflow control Electric heater stage 3 lockout protection (EC) — The modes are a fixed percentage of this selected airflow. control board includes a lockout feature to prevent the third stage of the electric heater from turning on if the Laptop configurable(EC)—The airflow for each mode of heat pump is also on. This prevents nuisance shutdowns operation is adjustable to any value between the blower from overheating the electric heater. This feature can be minimum and maximum using the ECMconfig software added to the ST control box by using an outside (available for download at www.unicosystem.com)and an thermostat. ordinary USB cable. Chiller water relay (EC- The control box includes a Laptop troubleshooting (EC)—The ECMconfig software separate dry-contact relay(ColdW)to turn on a chiller or will also provide the user with feedback reporting the zone pump. actual airflow, motor sp eed, communications status between the control board and the motor, and the state of Fan cycling(EC)—The control board includes a separate various inputs and outputs. switch to provide periodic cycling of the fan to reduce the chance for water to collect in the ducts if located in a cold Optimized for zoning with hydronic systems (EC) — The space and not used, or to provide periodic fresh air if ECMconfig software provides an additional feature that connected to a fresh air source. allows the user to limit the maximum motor speed. This prevents excessive motor ramping and eliminates the need EAC, ERV, or HRV relay (EC) — For the optimum in for bypass loops and pressure switch controls when zone indoor air quality,the control board includes a dry-contact dampers are closed. It reduces noise at the outlets caused relay to turn on an electronic air cleaner, energy recovery by the blower ramping to maintain a constant airflow with ventilator, or heat recovery ventilator any time the fan is fewer outlets. Do not set the maximum airflow to on. approximate constant static pressure with a single speed condensing unit. Refer to Unico Technical Bulletin 110 Potable water circulation (EC) — For improved health on zoning for more information. safety, the control board provides a switch-selectable feature to turn on the boiler pump periodically(if installed Optimized for efficiency and sound(EC)—The EC control as part of a domestic water system) to prevent the uses the lowest motor speed that can achieve the required formation of stagnant water. airflow, which minimizes noise and maximizes electrical Humidifier compatibility (EC) — The control board efficiency. includes the ability to connect a humidistat and a humidifier so that the humidistat turns on the humidifier ®Copyright 2012 Woo,Inc. Bulletin 20-20.1 —Page 4 Cabinet Construction All blower modules feature electrical connections and The cabinet is constructed of 22 gauge (0.7mm) service access panels on the left-hand side of the unit galvanized steel with removable access panels installed when viewing the return with the airflow at your back, on both sides for ease of service. All access panels are Right hand blowers are available upon request. In this secured with slotted hex head washer screws and case, the blower discharge opening is near the top of the hardened steel U-clip nuts to prevent stripping. The cabinet. cabinet is fully insulated with closed cell insulation. There is no exposed fiberglass inside the cabinet. See dimension drawing. Dimensional Data TOP VIEW �- A ELI LATCH CATCH F ftt.JlVl AEVV DE�L1A� 9.55 ALTERNATE S' �V 1/ CONTROL BOX 7.55 CONTROL BOX (243) LOCATION (192) KNOCKOUTS 4.29 (109) RESTRICTOR I ' PLATE (Not used with EC motor) i i I , Z AIR FLOW I I w -. OUTLET I — (445) 15.5 OPENING 6.38 (39) (FULL) (162) _ I x I �' 'D'Width / - .O(25)--- —B — 13.75(349) f PLENUM ADAPTER ALL DIMENSIONS IN inches(mm) (SOLD SEPARATELY) x Model No. M2430BLI M3036BLI M3642BLI M4860BLI A 25.00 (635) 30.00 (762) 38.00 (965) 38.00 (965) Dimensions B 6.00 (152) 7.24 (184) 7.16 (182) 9.92 (252) fin.(mm)] C 9.50 (242) 11.38 (289) 15.40 (392) 14.00 (356) D 23.00 (584) 28.00 (71 1) 36.00 (915) 36.00 (915) ®Copyright 2012 un,- Inc ----- —_-- 5/22/2018 Photo-Google Photos r • ... .. , MM. ia.M'• --Wmwr GeAV ! G7 y GD •��,.:"' ./J �Qt � I ��,14 ,,ar• fin • s � � N � aO i a Q � / 'vim:••.-., y a.. ' A ro of ' D we ' O y S i,y, • t C � � a � ,1 i I ,0 i �V� I I All ` � x r #SURVEY OF /nos .:?��.n-�l.. a �• 1�` ��.-� -t,�err.�►co�.s��c3t� �� Tc3Cric1/ct{- 7- https://photos.google.com/share/AF1 QipPk4alHmp7ZgrXH2w8QIM8HY32Bpg4BCITmDDlvklVNuVRdr2KgrnREhvdGN6LbMQ/photo/AF1 QipPeAIHPhdl Uuurwf58 l: T�^'^_"ky �A�,lpf,i 'y �S�A it \`�A�' �` �• i,� ' +fie _k.A�, v^ {tfi, ,meµ `�� " ti�j1�/�!� a •III�Ir i •N• v, ♦N ' v! d W•♦.{ v `r + �t�,, tllllllt � lllllll _ III/II 1/11 11/1{ . }� •11111r v ♦�• � 1�(s)$ � ==N111�,,.-P -�1111111 .,.:� � ,-r'_11l►/lllllll �11//1/11 1111t: 1 1 1111 r_.:..1/ 11 .�: �• lllllll/_- •: /1111 t � 1111/{�i c.• � 2 O � Ag A, F. c o C u t /XLIH CD +, Ln W c 0 0 ;-.. E �Z' ••1 W Z vOi `otectlohell �N ♦ �; 104 F Q m W W o r •-- ^�"+ > y O mac, Y c W a 4j wl C1, V L() t y cOi U 3 y z It{/lif/llt •� ., tli'/ . 11 I .1 1/11111 t z .�ail 1►i =.. ;��'lllilh t il!1►11 f'. '•S�" i /111.�''9 -' t 1 4�'-3_ � �(0)' la r //1• � : : 11111 '� '►1 1►I � I � -')� �►►I► �~ t Ill 11j. �• w@ ♦♦ I�w\C ♦��• 4`I)w �Ir /// `. i�i► t 1�/�!f ;f e,11111! O N � l ACOR" CERTIFICATE OF LIABILITY INSURANCE DATE(MM/DD/YYYY) 04/13/2018 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Anthony .Pepe NAME: y p AC Pepe Insurance P,eHCO No Ext: (845)724-3031 FAX,No): (845)724-3099 2568 Route 55 ADDRESS: apepe@pepeinsurance.com PO BOX 480 INSURER(S)AFFORDING COVERAGE NAIC N Poughquag NY 12570 INSURER A: Erie Insurance Company 26263 INSURED INSURER B: Erie Insurance P 8;C Co. 26830 INNOVATIVE AIR SOLUTIONS INC INSURER C: ShelterPoint Life Insurance Company INSURER D 11 KIMBALL PL INSURER E MOUNT VERNON NY 10550-4720 INSURER F: COVERAGES CERTIFICATE NUMBER: 04/12/2018-2019 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADDL SUBRI POLICY EFF POLICY EXP LTR TYPE OF INSURANCE INSD WVD POLICY NUMBER MM/DDfYYYY MM/DD/YYYV LIMITS X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 CLAIMS-MADE �OCCUR PREMISES Ea occurrence $ 1,000,000 MED EXP(Any one person) $ 5,000 A Y Q28-6220103 04/12/2018 04/12/2019 PERSONAL aADVINJURY $ 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER GENERAL AGGREGATE $ 2,000,000 X POLICY JEC PRODUCTS-COMP/OP AGG $ JECT LOC 2,000,000 OTHER $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ 1,000,000 Ea accident ANY AUTO BODILY INJURY(Per person) $ A OWNED IX SCHEDULED Q04-6240012 04/12/2018 04/12/2019 BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS X HIRED NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY Per.accident Uninsured motorist BI- $ 1,000,000 X UMBRELLA LIAB X OCCUR EACH OCCURRENCE $ 1,000,000 A EXCESS LLAB CLAIMS-MADE Q28-6270017 04/12/2018 04/12/2019 AGGREGATE $ 1,000,000 DED I X RETENTION$ 10,000 $ WORKERS COMPENSATION PER OTH- AND EMPLOYERS'LIABILITY Y/N X STATUTE ER ANY PROPRIETOR/PARTNER/EXECUTIVE 100,000 B OFFICERIMEMBER EXCLUDED? NIA Q88-6200166 04/12/2018 04/12/2019 E.L.EACH ACCIDENT $ (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE $ 100,000 if yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ 500,000 Disability Benefits C D 190877 10/28/2017 10/28/2018 DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space Is required) Village of Rye Brook are named as Additional Insured CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN Village of Rye Brook Building Department ACCORDANCE WITH THE POLICY PROVISIONS. 938 King St AUTHORIZED REPRESENTATIVE Rye Brook NY 10573 @ 1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD YORK Workers' CERTIFICATE OF STATE Compensation Board NYS WORKERS' COMPENSATION INSURANCE COVERAGE 1a.Legal Name 8 Address of Insured(use street address only) 1b.Business Telephone Number of Insured Innovative Air Solutions Inc 914-793-7700 11 Kimball Place Mount Vernon,NY 10550 1c.NYS Unemployment Insurance Employer Registration Number of Insured Work Location of Insured(Only required if coverage is specifically limited to 1d. Federal Employer Identification Number of Insured or Social Security certain locations in New York State,i.e.,a Wrap-Up Policy) Number 13-4141104 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) Erie Insurance Group Village of Rye Brook Building Department 938 King St Rye Brook,NY 10573 31b.Policy Number of Entity Listed in Box"1 a" 088-6200166 3c.Policy effective period 04/12/2018 to 04/12/2019 3d.The Proprietor,Partners or Executive Officers are Included.(Only check box if all partners/officers Included) �x all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box"T'insures the business referenced above in box"I a"for workers' compensation under the New York State Workers'Compensation Law. (To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". Will the carrier notify the certificate holder within 10 days of a policy being cancelled for non-payment of premium or within 30 days if cancelled for any other reason or if the insured is otherwise eliminated from the coverage indicated on this certificate prior to the end of the policy effective period? YES E]NO This certificate is issued as a matter of information only and confers no rights upon the certificate holder. This certificate does not amend, extend or alter the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note:Upon cancellation of the workers'compensation policy Indicated on this form,If the business continues to be named on a permit,license or contract Issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Anthony J Pepe (Print n of A ed rep Wave or licensed agent of insure ce carrier) Approved by: (Signatur (D e) Title: Agent Telephone Number of authorized representative or licensed agent of insurance carrier. 845-724-3031 Please Note: Only insurance carriers and their licensed agents are authorized to issue Form C-105.2.Insurance brokers are NOT authorized to Issue it. C-105.2(9-16) www.wcb.ny.gov